Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Hyg Environ Health ; 234: 113713, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33621861

RESUMO

We developed an inductively coupled plasma mass spectrometry (ICP-MS) method using Universal Cell Technology (UCT) with a PerkinElmer NexION ICP-MS, to measure arsenic (As), chromium (Cr), and nickel (Ni) in human urine samples. The advancements of the UCT allowed us to expand the calibration range to make the method applicable for both low concentrations of biomonitoring applications and high concentrations that may be observed from acute exposures and emergency response. Our method analyzes As and Ni in kinetic energy discrimination (KED) mode with helium (He) gas, and Cr in dynamic reaction cell (DRC) mode with ammonia (NH3) gas. The combination of these elements is challenging because a carbon source, ethanol (EtOH), is required for normalization of As ionization in urine samples, which creates a spectral overlap (40Ar12C+) on 52Cr. This method additionally improved lab efficiency by combining elements from two of our previously published methods(Jarrett et al., 2007; Quarles et al., 2014) allowing us to measure Cr and Ni concentrations in urine samples collected as part of the National Health and Nutrition Examination Survey (NHANES) beginning with the 2017-2018 survey cycle. We present our rigorous validation of the method selectivity and accuracy using National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM), precision using in-house prepared quality control materials, and a discussion of the use of a modified UCT, a BioUCell, to address an ion transmission phenomenon we observed on the NexION 300 platform when using higher elemental concentrations and high cell gas pressures. The rugged method detection limits, calculated from measurements in more than 60 runs, for As, Cr, and Ni are 0.23 µg L-1, 0.19 µg L-1, and 0.31 µg L-1, respectively.


Assuntos
Arsênio , Monitoramento Biológico , Cromo , Humanos , Níquel , Inquéritos Nutricionais , Tecnologia
2.
Environ Res ; 183: 109208, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32058143

RESUMO

OBJECTIVE: The objective of the current study is to report on urine, blood and serum metal concentrations to characterize exposures to trace elements and micronutrient levels in both pregnant women and women of child-bearing age in the U.S. National Health and Nutrition Examination Survey (NHANES) years 1999-2016. METHODS: Urine and blood samples taken from NHANES participants were analyzed for thirteen urine metals, three blood metals, three serum metals, speciated mercury in blood and speciated arsenic in urine. Adjusted and unadjusted least squares geometric means and 95% confidence intervals were calculated for all participants among women aged 15-44 years. Changes in exposure levels over time were also examined. Serum cotinine levels were used to adjust for smoke exposure, as smoking is a source of metal exposure. RESULTS: Detection rates for four urine metals from the ATSDR Substance Priority List: arsenic, lead, mercury and cadmium were ~83-99% for both pregnant and non-pregnant women of child bearing age. A majority of metal concentrations were higher in pregnant women compared to non-pregnant women. Pregnant women had higher mean urine total arsenic, urine mercury, and urine lead; however, blood lead and mercury were higher in non-pregnant women. Blood lead, cadmium, mercury, as well as urine antimony, cadmium and lead in women of childbearing age decreased over time, while urine cobalt increased over time. CONCLUSIONS: Pregnant women in the US have been exposed to several trace metals, with observed concentrations for some trace elements decreasing since 1999.


Assuntos
Arsênio , Exposição Materna , Mercúrio , Oligoelementos , Adolescente , Adulto , Cádmio , Criança , Feminino , Humanos , Exposição Materna/estatística & dados numéricos , Inquéritos Nutricionais , Gravidez , Estados Unidos , Adulto Jovem
3.
Talanta ; 162: 114-122, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27837806

RESUMO

We improved our inductively coupled plasma mass spectrometry (ICP-MS) whole blood method [1] for determination of lead (Pb), cadmium (Cd), and mercury (Hg) by including manganese (Mn) and selenium (Se), and expanding the calibration range of all analytes. The method is validated on a PerkinElmer (PE) ELAN® DRC II ICP-MS (ICP-DRC-MS) and uses the Dynamic Reaction Cell (DRC) technology to attenuate interfering background ion signals via ion-molecule reactions. Methane gas (CH4) eliminates background signal from 40Ar2+ to permit determination of 80Se+, and oxygen gas (O2) eliminates several polyatomic interferences (e.g. 40Ar15N+, 54Fe1H+) on 55Mn+. Hg sensitivity in DRC mode is a factor of two higher than vented mode when measured under the same DRC conditions as Mn due to collisional focusing of the ion beam. To compensate for the expanded method's longer analysis time (due to DRC mode pause delays), we implemented an SC4-FAST autosampler (ESI Scientific, Omaha, NE), which vacuum loads the sample onto a loop, to keep the sample-to-sample measurement time to less than 5min, allowing for preparation and analysis of 60 samples in an 8-h work shift. The longer analysis time also resulted in faster breakdown of the hydrocarbon oil in the interface roughing pump. The replacement of the standard roughing pump with a pump using a fluorinated lubricant, Fomblin®, extended the time between pump maintenance. We optimized the diluent and rinse solution components to reduce carryover from high concentration samples and prevent the formation of precipitates. We performed a robust calculation to determine the following limits of detection (LOD) in whole blood: 0.07µgdL-1 for Pb, 0.10µgL-1 for Cd, 0.28µgL-1 for Hg, 0.99µgL-1 for Mn, and 24.5µgL-1 for Se.


Assuntos
Exposição Dietética/análise , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Espectrometria de Massas/métodos , Oligoelementos/sangue , Cádmio/sangue , Calibragem , Monitoramento Ambiental/instrumentação , Humanos , Chumbo/sangue , Manganês/sangue , Mercúrio/sangue , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Selênio/sangue , Oligoelementos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...