Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EJNMMI Phys ; 7(1): 68, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33226495

RESUMO

BACKGROUND: Attenuation correction of PET/MRI is a remaining problem for whole-body PET/MRI. The statistical decomposition algorithm (SDA) is a probabilistic atlas-based method that calculates synthetic CTs from T2-weighted MRI scans. In this study, we evaluated the application of SDA for attenuation correction of PET images in the pelvic region. MATERIALS AND METHOD: Twelve patients were retrospectively selected from an ongoing prostate cancer research study. The patients had same-day scans of [11C]acetate PET/MRI and CT. The CT images were non-rigidly registered to the PET/MRI geometry, and PET images were reconstructed with attenuation correction employing CT, SDA-generated CT, and the built-in Dixon sequence-based method of the scanner. The PET images reconstructed using CT-based attenuation correction were used as ground truth. RESULTS: The mean whole-image PET uptake error was reduced from - 5.4% for Dixon-PET to - 0.9% for SDA-PET. The prostate standardized uptake value (SUV) quantification error was significantly reduced from - 5.6% for Dixon-PET to - 2.3% for SDA-PET. CONCLUSION: Attenuation correction with SDA improves quantification of PET/MR images in the pelvic region compared to the Dixon-based method.

2.
J Nucl Med Technol ; 41(2): 85-91, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23658206

RESUMO

UNLABELLED: In PET, partial-volume effects cause errors in estimation of size and activity for small objects with radiopharmaceutical uptake. Recent methods for image reconstruction, compared with traditional reconstruction techniques, include algorithms for resolution recovery that result in images with higher resolution and enable quantification of size and activity of smaller objects. The purpose of this study was to evaluate a combination of 2 algorithms for volume delineation and partial-volume correction on uptake volumes smaller than 0.7 mL using image reconstruction algorithms with and without resolution recovery. METHODS: Volumes of interests (VOIs) were delineated using a threshold intensity calculated as a weighted sum of tumor and background intensities. These VOIs were used for calculating correction factors by convolving a tumor mask with the system point-spread function. The methods algorithms were evaluated using a phantom constructed from 5 small different-sized balloons filled with (18)F-FDG in background activity. Six different backgrounds were used. Data were acquired using a PET/CT scanner, and the images were reconstructed using 2 iterative algorithms, one of which used a resolution recovery algorithm. RESULTS: For the images reconstructed using the resolution recovery algorithm, the method for volume delineation resulted in VOI sizes that were correct within 1 SD for all balloons of a volume of 0.35 mL (equivalent diameter, 8.8 mm) and larger, in all backgrounds. For the images reconstructed without resolution recovery, the VOI sizes were background-dependent and generally less accurate. Correct volume delineations generally led to accurate activity estimates. CONCLUSION: The algorithms tested on the phantom developed for this study could, for this PET camera and these reconstruction algorithms, be used for accurate volume delineation and activity quantification of lesions 0.35 mL and larger.


Assuntos
Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Carga Tumoral , Humanos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...