Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
2.
Bone Joint J ; 101-B(1_Supple_A): 59-65, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30648493

RESUMO

AIMS: Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. PATIENTS AND METHODS: A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry. RESULTS: A total of 100 TKAs in 92 patients were included. Three patients died (three TKAs) and a further two TKAs were revised. Of the remaining 95 TKAs, five-year follow-up data were available for 81 TKAs (85%) in 87 patients. There were significant improvements in all PROMs and high satisfaction. The mean ROM at final follow-up was from 0° (full extension) to 124° flexion. There were seven major complications (7%): one infection, two deep vein thromboses, one cerebrovascular event, and two patients with stiffness requiring a manipulation under anaesthesia. Two patients required a lateral retinacular release to optimize patellar tracking in valgus knees; no additional ligament releases were performed in any patient. Radiological analysis demonstrated no evidence of implant-related complications. CONCLUSION: These results demonstrate satisfactory clinical and radiological outcomes at five years following a medial ball and socket TKA. The complication and revision rates are consistent with those previously reported for patients undergoing TKA. These results demonstrate the safety and efficacy of the SAIPH Knee TKA system and support its wider use.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Complicações Pós-Operatórias , Desenho de Prótese , Falha de Prótese/etiologia , Radiografia , Amplitude de Movimento Articular , Reoperação/estatística & dados numéricos , Estudos Retrospectivos
3.
Acta Orthop Belg ; 83(1): 81-86, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29322899

RESUMO

Intra- operative changes in pelvic position during total hip arthroplasty (THA) can affect acetabular orientation. We evaluated these changes during supine THA using a proprietary mobile application called PelvicTracker. Twenty- two patients undergoing THA using direct anterior approach were included in the study. In the sagittal plane, the pelvis was extended (anterior tilt) as compared to the start of surgery in 19/ 22 hips at the time of cup implantation (mean extension: 3.1°; range: 1°-6°). In the transverse plane, the pelvis was rolled to the opposite side of surgery in 12 hips (mean roll: 2.8°; range: 1°-5°), to the same side in 8 hips (mean roll: 3.9°, range: 1°-9°) and unchanged in 2 hips at the time of cup implantation. Predicted change in cup version of ≥5° due to changes in pelvic position was seen in 7/22 (32%) patients. Although minor, changes in pelvic position do occur during supine THA which may affect acetabular orientation.


Assuntos
Acetábulo , Artroplastia de Quadril , Movimento , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Posicionamento do Paciente , Decúbito Dorsal
4.
Bone Joint Res ; 5(9): 370-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27608650

RESUMO

OBJECTIVES: This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS: The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS: The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION: This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage.Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370-378. DOI: 10.1302/2046-3758.59.2000507.

5.
Bone Joint J ; 96-B(11): 1449-54, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25371455

RESUMO

We describe the clinical and radiological results of cementless primary total hip replacement (THR) in 25 patients (18 women and seven men; 30 THRs) with severe developmental dysplasia of the hip (DDH). Their mean age at surgery was 47 years (23 to 89). In all, 21 hips had Crowe type III dysplasia and nine had Crowe type IV. Cementless acetabular components with standard polyethylene liners were introduced as close to the level of the true acetabulum as possible. The modular cementless S-ROM femoral component was used with a low resection of the femoral neck. A total of 21 patients (25 THRs) were available for review at a mean follow-up of 18.7 years (15.8 to 21.8). The mean modified Harris hip score improved from 46 points pre-operatively to 90 at final follow up (p < 0.001). A total of 15 patients (17 THRs; 57%) underwent revision of the acetabular component at a mean of 14.6 years (7 to 20.8), all for osteolysis. Two patients (two THRs) had symptomatic loosening. No patient underwent femoral revision. Survival with revision of either component for any indication was 81% at 15 years (95% CI 60.1 to 92.3), with 21 patients at risk. This technique may reduce the need for femoral osteotomy in severe DDH, while providing a good long-term functional result.


Assuntos
Artroplastia de Quadril/métodos , Previsões , Luxação do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia , Radiografia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
6.
Bone Joint J ; 96-B(6): 730-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24891571

RESUMO

We report on 397 consecutive revision total hip replacements in 371 patients with a mean clinical and radiological follow-up of 12.9 years (10 to 17.7). The mean age at surgery was 69 years (37 to 93). A total of 28 patients (8%) underwent further revision, including 16 (4%) femoral components. In all 223 patients (56%, 233 hips) died without further revision and 20 patients (5%, 20 hips) were lost to follow-up. Of the remaining patients, 209 (221 hips) were available for clinical assessment and 194 (205 hips) for radiological review at mean follow-up of 12.9 years (10 to 17.7). The mean Harris Hip Score improved from 58.7 (11 to 92) points to 80.7 (21 to 100) (p < 0.001) and the mean Merle d'Aubigné and Postel hip scores at final follow-up were 4.9 (2 to 6), 4.5 (2 to 6) and 4.3 (2 to 6), respectively for pain, mobility and function. Radiographs showed no lucencies around 186 (90.7%) femoral stems with stable bony ingrowth seen in 199 stems (97%). The survival of the S-ROM femoral stem at 15 years with revision for any reason as the endpoint was 90.5% (95% confidence interval (CI) 85.7 to 93.8) and with revision for aseptic loosening as the endpoint 99.3% (95% CI 97.2 to 99.8). We have shown excellent long-term survivorship and good clinical outcome of a cementless hydroxyapatite proximally-coated modular femoral stem in revision hip surgery.


Assuntos
Artroplastia de Quadril/efeitos adversos , Materiais Revestidos Biocompatíveis , Durapatita/farmacologia , Prótese de Quadril , Desenho de Prótese/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Estudos de Coortes , Intervalos de Confiança , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Bone Joint J ; 96-B(2): 181-7, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24493182

RESUMO

Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16,828 CoC THR that reported squeaking, or revision for squeaking, were entered into the analysis. The incidence of squeaking was 4.2% and the incidence of revision for squeaking was 0.2%. The incidence of squeaking in patients receiving the Accolade femoral stem was 8.3%, and the incidence of revision for squeaking in these patients was 1.3%.


Assuntos
Artroplastia de Quadril , Cerâmica , Prótese de Quadril , Ortopedia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Sociedades Médicas , Austrália/epidemiologia , Prótese de Quadril/efeitos adversos , Humanos , Incidência , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Reoperação , Propriedades de Superfície , Fatores de Tempo
8.
Bone Joint J ; 95-B(12): 1603-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24293588

RESUMO

We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Prótese de Quadril , Adulto , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Criança , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação/estatística & dados numéricos , Índice de Gravidade de Doença , Resultado do Tratamento
9.
Bone Joint J ; 95-B(3): 333-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23450016

RESUMO

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted. The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip. There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component. The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Hemiartroplastia/instrumentação , Prótese de Quadril , Falha de Prótese , Acetábulo , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite/cirurgia , Feminino , Seguimentos , Luxação do Quadril/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Reoperação/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
10.
J Bone Joint Surg Br ; 94(7): 901-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733943

RESUMO

We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm(3)/year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Óxido de Alumínio , Artroplastia de Quadril/métodos , Cerâmica , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Suporte de Carga
11.
J Bone Joint Surg Br ; 94(6): 735-45, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22628586

RESUMO

This systematic review of the literature summarises the clinical experience with ceramic-on-ceramic hip bearings over the past 40 years and discusses the concerns that exist in relation to the bearing combination. Loosening, fracture, liner chipping on insertion, liner canting and dissociation, edge-loading and squeaking have all been reported, and the relationship between these issues and implant design and surgical technique is investigated. New design concepts are introduced and analysed with respect to previous clinical experience.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Prótese de Quadril , Artroplastia de Quadril/métodos , Artroplastia de Quadril/tendências , Prótese de Quadril/tendências , Humanos , Desenho de Prótese , Falha de Prótese
12.
J Bone Joint Surg Br ; 94(2): 281-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22323701

RESUMO

We report a case of a male patient presenting with bilateral painful but apparently well-positioned and -fixed large-diameter metal-on-metal hip replacements four years post-operatively. Multiple imaging modes revealed a thick-walled, cystic expansile mass in communication with the hip joint (a pseudotumour). Implant retrieval analysis and tissue culture eliminated high bearing wear or infection as causes for the soft-tissue reaction, but noted marked corrosion of the modular neck taper adaptor and corrosion products in the tissues. Therefore, we believe corrosion products from the taper caused by mismatch of the implant components led to pseudotumour formation requiring revision.


Assuntos
Granuloma de Células Plasmáticas/etiologia , Articulação do Quadril/patologia , Prótese de Quadril/efeitos adversos , Idoso , Artroplastia de Quadril/efeitos adversos , Corrosão , Granuloma de Células Plasmáticas/diagnóstico , Granuloma de Células Plasmáticas/patologia , Articulação do Quadril/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Falha de Prótese , Tomografia Computadorizada por Raios X
13.
J Bone Joint Surg Br ; 93(12): 1597-601, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22161920

RESUMO

This multicentre study analysed 12 alumina ceramic-on-ceramic components retrieved from squeaking total hip replacements after a mean of 23 months in situ (11 to 61). The rates and patterns of wear seen in these squeaking hips were compared with those seen in matched controls using retrieval data from 33 'silent' hip replacements with similar ceramic bearings. All 12 bearings showed evidence characteristic of edge-loading wear. The median rate of volumetric wear was 3.4 mm(3)/year for the acetabular component, 2.9 mm(3)/year on the femoral heads and 6.3 mm(3)/year for head and insert combined. This was up to 45 times greater than that of previously reported silent ceramic-on-ceramic retrievals. The rate of wear seen in ceramic components revised for squeaking hips appears to be much greater than in that seen in retrievals from 'silent' hips.


Assuntos
Artroplastia de Quadril/instrumentação , Análise de Falha de Equipamento/estatística & dados numéricos , Prótese de Quadril/efeitos adversos , Ruído , Complicações Pós-Operatórias/etiologia , Falha de Prótese/efeitos adversos , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Estudos de Casos e Controles , Cerâmica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/efeitos adversos , Falha de Tratamento
14.
J Bone Joint Surg Br ; 93(4): 439-42, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21464479

RESUMO

We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no patient had undergone previous surgery to the hip. We identified 74 squeaking hips (73 patients) giving an incidence of 3.1% at a mean follow-up of 9.5 years (4.1 to 13.3). Taller, heavier and younger patients were significantly more likely to have hips that squeaked. Squeaking hips had a significantly higher range of post-operative internal (p = 0.001) and external rotation (p = 0.003) compared with silent hips. Patients with squeaking hips had significantly higher activity levels (p = 0.009). A squeaking hip was not associated with a significant difference in patient satisfaction (p = 0.24) or Harris hip score (p = 0.34). Four implant position factors enabled good prediction of squeaking. These were high acetabular component inclination, high femoral offset, lateralisation of the hip centre and either high or low acetabular component anteversion. This is the largest study to date to examine patient factors and implant position factors that predispose to squeaking of a ceramic-on-ceramic hip. The results suggest that factors which increase the mechanical forces across the hip joint and factors which increase the risk of neck-to-rim impingement, and therefore edge-loading, are those that predispose to squeaking.


Assuntos
Artroplastia de Quadril/métodos , Cerâmica , Prótese de Quadril , Ruído , Osteoartrite do Quadril/cirurgia , Acetábulo/cirurgia , Atividades Cotidianas , Fatores Etários , Idoso , Área Sob a Curva , Índice de Massa Corporal , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Amplitude de Movimento Articular
15.
J Bone Joint Surg Br ; 92(4): 469-76, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20357319

RESUMO

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Australian National Joint Registry reported an inverse relationship between the size of the head component and the risk of revision in resurfacing hip arthroplasty. Hips with a femoral component size of /= 55 mm irrespective of gender. We have reviewed the literature to explore this observation and to identify possible reasons including the design of the implant, loading of the femoral neck, the orientation of the component, the production of wear debris and the effects of metal ions, penetration of cement and vascularity of the femoral head. Our conclusion is that although multifactorial, the most important contributors to failure in resurfacing arthroplasty of the hip are likely to be the design and geometry of the component and the orientation of the acetabular component.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Artroplastia de Quadril/métodos , Cabeça do Fêmur/irrigação sanguínea , Colo do Fêmur/fisiopatologia , Humanos , Desenho de Prótese , Falha de Prótese , Fluxo Sanguíneo Regional , Estresse Mecânico
16.
J Bone Joint Surg Br ; 91(11): 1448-53, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19880888

RESUMO

Dislocation is a common reason for revision following total hip replacement. This study investigated the relationship between the bearing surface and the risk of revision due to dislocation. It was based on 110 239 primary total hip replacements with a diagnosis of osteoarthritis collected by the Australian Orthopaedic Association National Joint Replacement Registry between September 1999 and December 2007. A total of 862 (0.78%) were revised because of dislocation. Ceramic-on-ceramic bearing surfaces had a lower risk of requiring revision due to dislocation than did metal-on-polyethylene and ceramic-on-polyethylene surfaces, with a follow-up of up to seven years. However, ceramic-on-ceramic implants were more likely to have larger prosthetic heads and to have been implanted in younger patients. The size of the head of the femoral component and age are known to be independent predictors of dislocation. Therefore, the outcomes were stratified by the size of the head and age. There is a significantly higher rate of revision for dislocation in ceramic-on-ceramic bearing surfaces than in metal-on-polyethylene implants when smaller sizes (< or = 28 mm) of the head were used in younger patients (< 65 years) (hazard ratio = 1.53, p = 0.041) and also with larger (> 28 mm) and in older patients (> or = 65 years) (hazard ratio = 1.73, p = 0.016).


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/etiologia , Prótese de Quadril , Fatores Etários , Idoso , Cerâmica , Feminino , Cabeça do Fêmur/patologia , Seguimentos , Luxação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Propriedades de Superfície
17.
J Bone Joint Surg Br ; 91(10): 1296-300, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19794162

RESUMO

The outcome of total hip replacement (THR) is potentially affected by the body mass index (BMI) of the patient. We studied the outcome of 2026 consecutive primary cementless THRs performed for osteoarthritis. The mean follow-up was 6.3 years (0 to 11.71) and no patient was lost to follow-up for survival analysis. The patients were divided into two groups according to their BMI as follows: non-obese (BMI < 30 kg/m(2)) and obese (BMI > or = 30 kg/m(2)). The obese patient undergoing surgery was found to be significantly younger (p < 0.001). The log-rank test for equality of survival showed no difference in the mid-term survival (p = 0.552) with an estimated survival at 11 years of 95.2% (95% CI 92.5 to 98.0) in the non-obese and 96.7% (95% CI 94.9 to 98.5) in the obese groups. The clinical and radiological outcome was determined in a case-matched study performed on 134 obese individuals closely matched with 134 non-obese controls. The non-obese group was found to have a significantly higher post-operative Harris hip score (p < 0.001) and an increased range of movement, but overall satisfaction with surgery was comparable with that of the obese patients. Radiological analysis of the acetabular and femoral components showed no significant differences with regard to radiolucent lines, osteolysis, ingrowth of the femoral component, the acetabular inclination angle or alignment of the femoral component. Our results suggest that the survival of cementless THR is not adversely affected by obesity. Obese patients can therefore be counselled that despite a lower clinical score, they should expect to be satisfied with the result of their THR with a mid-term survival rate equivalent to that of non-obese patients.


Assuntos
Artroplastia de Quadril/métodos , Obesidade/complicações , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Suporte de Carga/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/fisiopatologia , Prognóstico , Resultado do Tratamento , Adulto Jovem
18.
J Bone Joint Surg Br ; 91(8): 1044-8, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19651831

RESUMO

We evaluated 535 consecutive primary cementless total knee replacements (TKR). The mean follow-up was 9.2 years (0.3 to 12.9) and information on implant survival was available for all patients. Patients were divided into two groups: 153 obese patients (BMI > or = 30) and 382 non-obese (BMI < 30). A case-matched study was performed on the clinical and radiological outcome, comparing 50 knees in each group. We found significantly lower mean improvements in the clinical score (p = 0.044) and lower post-operative total clinical scores in the obese group (p = 0.041). There was no difference in the rate of radiological osteolysis or lucent lines, and no difference in alignment. Log rank test for survival showed no significant differences between the groups (p = 0.167), with a ten-year survival rate of 96.4% (95% confidence interval (CI) 92 to 99) in the obese and 98% (95% CI 96 to 99) in the non-obese. The mid-term survival of TKR in the obese and the non-obese are comparable, but obesity appears to have a negative effect on the clinical outcome. However, good results and high patient satisfaction are still to be expected, and it would seem unreasonable to deny patients a TKR simply on the basis of a BMI indicating obesity.


Assuntos
Artroplastia do Joelho/métodos , Obesidade/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Métodos Epidemiológicos , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Amplitude de Movimento Articular/fisiologia , Suporte de Carga
19.
J Bone Joint Surg Am ; 89(12): 2676-83, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18056500

RESUMO

BACKGROUND: Wear debris has been implicated in the pathogenesis of osteolysis. Alumina-on-alumina ceramic bearings have a low wear rate, which may reduce the prevalence of osteolysis. The purpose of this study was to determine the rates of wear and osteolysis associated with modern cementless hip arthroplasty with alumina-on-alumina bearings at five years. METHODS: We analyzed a series of 301 third-generation alumina-on-alumina cementless primary total hip replacements in 283 patients. The average age of the patients at the time of the arthroplasty was fifty-eight years. All procedures were performed with use of the same surgical technique and the same implant at a single center. At a minimum of five years postoperatively, ten patients had died and twenty-two patients were lost to follow-up. We assessed patients clinically and radiographically, and all retrieved bearings were analyzed for wear. RESULTS: At the time of the latest follow-up, the mean Harris hip score was 95 points. All surviving implants had radiographic evidence of stable bone ingrowth. There were nine revisions of one or both components. Four stems were revised following periprosthetic fracture, one stem was revised because of aseptic loosening at two months, and one stem was revised to facilitate a femoral shortening osteotomy. Two cups were revised because of psoas tendinitis, and both components of one arthroplasty were revised because of impingement and osteolysis. The rate of survival of both components, with revision because of aseptic loosening or osteolysis as the end point, was 99% at seven years. The retrieved femoral heads showed an early median wear rate of 0.2 mm(3) per year. CONCLUSIONS: Cementless primary total hip prostheses with a third-generation alumina-on-alumina bearing showed very low wear and were associated with minimal osteolysis at the time of follow-up, at a minimum of five years.


Assuntos
Artroplastia de Quadril/instrumentação , Osteólise/prevenção & controle , Desenho de Prótese , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/efeitos adversos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Radiografia , Reoperação
20.
J Bone Joint Surg Br ; 89(9): 1158-64, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17905951

RESUMO

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm(3)/yr for the femoral heads, and 0.04 mm(3)/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15 degrees (seven femoral heads) had a median femoral head wear rate of 1.2 mm(3)/yr, compared with 0 mm(3)/yr for those with an anteversion of > or =15 degrees (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.


Assuntos
Óxido de Alumínio , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Acetábulo/cirurgia , Cerâmica , Análise de Falha de Equipamento/métodos , Humanos , Orientação , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...