Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Langmuir ; 39(40): 14223-14230, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37753720

RESUMO

To quantify colloidal filtration, a quartz crystal microbalance (QCM) with a silicon dioxide surface is embedded on the inner surface of a microfluidic channel to monitor the real-time particle deposition. Potassium chloride solution with micrometer-size polystyrene particles simulating bacterial strains flows down the channel. In the presence of intrinsic Derjaguin-Landau-Verwey-Overbeek (DLVO) intersurface forces, particles are trapped by the quartz surfaces, and the increased mass shifts the QCM resonance frequency. The method provides an alternative way to measure filtration efficiency in an optically opaque channel and its dependence on the ionic concentration.

2.
Langmuir ; 39(18): 6487-6494, 2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37098136

RESUMO

Micron-size spherical polystyrene colloidal particles are mechanically stretched to a prolate geometry with desirable aspect ratios. The particles in an aqueous medium with specific ionic concentration are then introduced into a microchannel and allowed to settle on a glass substrate. In the presence of unidirectional flow, the loosely adhered particles in the secondary minimum of surface interaction potential are easily washed off, but the remnant in the strong primary minimum preferentially aligns with the flow direction and exercises in-plane rotation. A rigorous theoretical model is constructed to account for filtration efficiency in terms of hydrodynamic drag, intersurface forces, reorientation of prolate particles, and their dependence on flowrate and ionic concentration.

3.
Langmuir ; 38(50): 15534-15539, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36493398

RESUMO

An acoustically levitated air-in-liquid compound drop is set into an out-of-phase azimuthal sloshing resonance by a modulated frequency with modes n = 4-9. Waveforms of the inner and outer liquid-air interfaces conform to the classical Saffren model. Resonance peaks and their harmonics in the frequency spectrum are found to be a function of drop dimension and resonance modes. Drops with multiple small air bubbles do not resonate in sync because of asymmetry. This work has significant implications in the dynamics of core-shell compound drops.

4.
ACS Omega ; 6(49): 33511-33522, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34926900

RESUMO

Biodegradable cellular and acellular scaffolds have great potential to regenerate damaged tissues or organs by creating a proper extracellular matrix (ECM) capable of recruiting endogenous cells to support cellular ingrowth. However, since hydrogel-based scaffolds normally degrade through surface erosion, cell migration and ingrowth into scaffolds might be inhibited early in the implantation. This could result in insufficient de novo tissue formation in the injured area. To address these challenges, continuous and microsized strand-like networks could be incorporated into scaffolds to guide and recruit endogenous cells in rapid manner. Fabrication of such microarchitectures in scaffolds is often a laborious and time-consuming process and could compromise the structural integrity of the scaffold or impact cell viability. Here, we have developed a fast single-step approach to fabricate colloidal hydrogels, which are made up of randomly packed human serum albumin-based photo-cross-linkable microparticles with continuous internal networks of microscale voids. The human serum albumin conjugated with methacrylic groups were assembled to microsized aggregates for achieving unique porous structures inside the colloidal gels. The albumin hydrogels showed tunable mechanical properties such as elastic modulus, porosity, and biodegradability, providing a suitable ECM for various cells such as cardiomyoblasts and endothelial cells. In addition, the encapsulated cells within the hydrogel showed improved cell retention and increased survivability in vitro. Microporous structures of the colloidal gels can serve as a guide for the infiltration of host cells upon implantation, achieving rapid recruitment of hematopoietic cells and, ultimately, enhancing the tissue regeneration capacity of implanted scaffolds.

5.
Langmuir ; 37(43): 12714-12722, 2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34664966

RESUMO

A homemade instrument is designed to directly characterize the adhesion between two rigid polymeric microspheres in the presence of moist air. The tensile load is measured as a function of approach distance at designated relative humidity (RH). The measurement is consistent with our model from the first approximation. The model is further extended to include a rough surface. Capillary adhesion force is shown to be monotonically increasing with RH for smooth surfaces but becomes more pronounced at low RH for rough surfaces. Moisture has a profound influence on interparticle adhesion, which has significant impacts on a wide range of industrial applications.

6.
Nanoscale ; 13(3): 1485-1506, 2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33439199

RESUMO

Encapsulation of metal nanoparticles just below the surface of a prototypical layered material, graphite, is a recently discovered phenomenon. These encapsulation architectures have potential for tuning the properties of two-dimensional or layered materials, and additional applications might exploit the properties of the encapsulated metal nanoclusters themselves. The encapsulation process produces novel surface nanostructures and can be achieved for a variety of metals. Given that these studies of near-surface intercalation are in their infancy, these systems provide a rich area for future studies. This Review presents the current progress on the encapsulation, including experimental strategies and characterization, as well as theoretical understanding which leads to the development of predictive capability. The Review closes with future opportunities where further understanding of the encapsulation is desired to exploit its applications.

7.
ACS Nano ; 13(11): 12525-12539, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31621284

RESUMO

Myocardial microenvironment plays a decisive role in guiding the function and fate of cardiomyocytes, and engineering this extracellular niche holds great promise for cardiac tissue regeneration. Platforms utilizing hybrid hydrogels containing various types of conductive nanoparticles have been a critical tool for constructing engineered cardiac tissues with outstanding mechanical integrity and improved electrophysiological properties. However, there has been no attempt to directly compare the efficacy of these hybrid hydrogels and decipher the mechanisms behind how these platforms differentially regulate cardiomyocyte behavior. Here, we employed gelatin methacryloyl (GelMA) hydrogels containing three different types of carbon-based nanoparticles: carbon nanotubes (CNTs), graphene oxide (GO), and reduced GO (rGO), to investigate the influence of these hybrid scaffolds on the structural organization and functionality of cardiomyocytes. Using immunofluorescent staining for assessing cellular organization and proliferation, we showed that electrically conductive scaffolds (CNT- and rGO-GelMA compared to relatively nonconductive GO-GelMA) played a significant role in promoting desirable morphology of cardiomyocytes and elevated the expression of functional cardiac markers, while maintaining their viability. Electrophysiological analysis revealed that these engineered cardiac tissues showed distinct cardiomyocyte phenotypes and different levels of maturity based on the substrate (CNT-GelMA: ventricular-like, GO-GelMA: atrial-like, and rGO-GelMA: ventricular/atrial mixed phenotypes). Through analysis of gene-expression patterns, we uncovered that the engineered cardiac tissues matured on CNT-GelMA and native cardiac tissues showed comparable expression levels of maturation markers. Furthermore, we demonstrated that engineered cardiac tissues matured on CNT-GelMA have increased functionality through integrin-mediated mechanotransduction (via YAP/TAZ) in contrast to cardiomyocytes cultured on rGO-GelMA.


Assuntos
Miocárdio , Nanotubos de Carbono/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Células Cultivadas , Grafite/química , Hidrogéis/química , Mecanotransdução Celular/fisiologia , Miocárdio/citologia , Miocárdio/metabolismo , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/fisiologia , Ratos , Ratos Sprague-Dawley
8.
Nanoscale ; 11(13): 6445-6452, 2019 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-30888382

RESUMO

Shapes of functional metallic nanocrystals, typically synthesized either free in solution or supported on surfaces, are key for controlling properties. Here, we consider a novel new class of metallic nanocrystals, copper clusters embedded near the surface of graphite, which can be considered a model system for metals embedded beneath surfaces of layered materials, or beneath supported membranes. We develop a continuum elasticity (CE) model for the equilibrium shape of these islands, and compare its predictions with experimental data. The CE model incorporates appropriate surface energy, adhesion energies, and strain energy. The agreement between the CE model and the data is-with one exception-excellent, both qualitatively and quantitatively, and is achieved with a single adjustable parameter. The model predicts that the embedded island shape is invariant with size, manifest both by constant side slope and by constant aspect ratio. This prediction is rationalized by dimensional analysis of the relevant energetic contributions. The aspect ratio (width : height) of an embedded Cu cluster is much larger than that of a supported but non-embedded Cu cluster, due to resistance of the graphene membrane to deformation. Experimental data diverge from the model predictions only in the case of the aspect ratio of small islands, below a critical height of ∼10 nm. The divergence may be due to bending strain, which is treated only approximately in the model. Strong support for the CE model and its interpretation is provided by additional data for embedded Fe clusters. Most of these observations and insights should be generally applicable to systems where a metal cluster is embedded beneath a layered material or supported membrane, provided that shape equilibration is possible.

9.
Colloids Surf B Biointerfaces ; 165: 381-387, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29529580

RESUMO

A microfluidic device was designed to investigate filtration of particles in an electrolyte in the presence of liquid flow. Polystyrene spheres in potassium chloride solution at concentrations of 3-100 mM were allowed to settle and adhere to a glass substrate. A particle free solution at the same concentration was then flushed through the microfluidic channel at 0.03-4.0 mL/h. As the hydrodynamic drag on the adhered particles exceeded the intersurface interaction with the substrate, "pull-off" occurred and the particles detached. Filtration efficiency, α, was shown to a function of both ionic concentration of the liquid medium and flow speed, consistent with a phenomenological model based on the classical DLVO theory. The results elucidates the underlying physics of filtration.


Assuntos
Filtração/métodos , Vidro/química , Microfluídica/métodos , Poliestirenos/química , Cloreto de Potássio/química , Coloides , Dimetilpolisiloxanos/química , Eletrólitos/química , Filtração/instrumentação , Hidrodinâmica , Cinética , Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação , Microesferas , Termodinâmica
10.
Adv Mater ; 30(10)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29323433

RESUMO

To create life-like movements, living muscle actuator technologies have borrowed inspiration from biomimetic concepts in developing bioinspired robots. Here, the development of a bioinspired soft robotics system, with integrated self-actuating cardiac muscles on a hierarchically structured scaffold with flexible gold microelectrodes is reported. Inspired by the movement of living organisms, a batoid-fish-shaped substrate is designed and reported, which is composed of two micropatterned hydrogel layers. The first layer is a poly(ethylene glycol) hydrogel substrate, which provides a mechanically stable structure for the robot, followed by a layer of gelatin methacryloyl embedded with carbon nanotubes, which serves as a cell culture substrate, to create the actuation component for the soft body robot. In addition, flexible Au microelectrodes are embedded into the biomimetic scaffold, which not only enhance the mechanical integrity of the device, but also increase its electrical conductivity. After culturing and maturation of cardiomyocytes on the biomimetic scaffold, they show excellent myofiber organization and provide self-actuating motions aligned with the direction of the contractile force of the cells. The Au microelectrodes placed below the cell layer further provide localized electrical stimulation and control of the beating behavior of the bioinspired soft robot.


Assuntos
Eletricidade , Materiais Biocompatíveis , Gelatina , Hidrogéis , Miócitos Cardíacos , Nanotubos de Carbono
11.
Langmuir ; 33(44): 12592-12595, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-28972770

RESUMO

Adhesion at the dissimilar interface of single wall carbon nanotube (SWCNT) bundles and electrospun polymer nanofibers (Espun) was directly measured using a nano cheese cutter. A sample fiber suspended at the tip of an atomic force microscope cantilever and another freestanding fiber on a mica substrate were arranged in a cross-cylinder configuration and allowed to adhere. External tensile load led to spontaneous detachment or "pull-off". Adhesion was shown to be dominated by van der Waals attraction, and the detachment process conforms to the classical Maugis parameter in the JKR-DMT transition.

12.
Small ; 12(27): 3677-89, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27254107

RESUMO

Biomaterials currently used in cardiac tissue engineering have certain limitations, such as lack of electrical conductivity and appropriate mechanical properties, which are two parameters playing a key role in regulating cardiac cell behavior. Here, the myocardial tissue constructs are engineered based on reduced graphene oxide (rGO)-incorporated gelatin methacryloyl (GelMA) hybrid hydrogels. The incorporation of rGO into the GelMA matrix significantly enhances the electrical conductivity and mechanical properties of the material. Moreover, cells cultured on composite rGO-GelMA scaffolds exhibit better biological activities such as cell viability, proliferation, and maturation compared to ones cultured on GelMA hydrogels. Cardiomyocytes show stronger contractility and faster spontaneous beating rate on rGO-GelMA hydrogel sheets compared to those on pristine GelMA hydrogels, as well as GO-GelMA hydrogel sheets with similar mechanical property and particle concentration. Our strategy of integrating rGO within a biocompatible hydrogel is expected to be broadly applicable for future biomaterial designs to improve tissue engineering outcomes. The engineered cardiac tissue constructs using rGO incorporated hybrid hydrogels can potentially provide high-fidelity tissue models for drug studies and the investigations of cardiac tissue development and/or disease processes in vitro.


Assuntos
Grafite/química , Hidrogéis/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Materiais Biocompatíveis/química , Gelatina/química , Microscopia Eletrônica de Transmissão
13.
Sci Rep ; 5: 15908, 2015 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-26511284

RESUMO

Suspended single-walled carbon nanotubes (SWCNTs) offer unique functionalities for electronic and electromechanical systems. Due to their outstanding flexible nature, suspended SWCNT architectures have great potential for integration into flexible electronic systems. However, current techniques for integrating SWCNT architectures with flexible substrates are largely absent, especially in a manner that is both scalable and well controlled. Here, we present a new nanostructured transfer paradigm to print scalable and well-defined suspended nano/microscale SWCNT networks on 3D patterned flexible substrates with micro- to nanoscale precision. The underlying printing/transfer mechanism, as well as the mechanical, electromechanical, and mechanical resonance properties of the suspended SWCNTs are characterized, including identifying metrics relevant for reliable and sensitive device structures. Our approach represents a fast, scalable and general method for building suspended nano/micro SWCNT architectures suitable for flexible sensing and actuation systems.

14.
Environ Sci Technol ; 48(3): 1769-78, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24450282

RESUMO

In this study, we employed AFM analysis combined with mathematical modeling for quantifying cell-surface contact mechanics and magnitude and range of cell-surface interaction forces for seven bacterial strains with a wide range of cell morphology, dimension, and surface characteristics. Comprehensive cell-surface characterization including surface charge, extracellular polymeric substance content, hydrophobicity, and cell-cell aggregation analyses were performed. Flow-through column tests were employed to determine the attachment efficiency and deposition-transport behavior of these bacterial strains. No statistically significant correlation between attachment efficiency and any single-cell surface property was identified. Single-cell characterization by atomic force microscopy (AFM) yielded the mechanical deformation and elastic modulus, penetration resistance to AFM probe penetration by cellular surface substances (CSS), range and magnitude of the repulsive-attractive intersurface forces, and geometry of each strain. We proposed and derived a universal dimensionless modified Tabor's parameter to integrate all these properties that account for their collective behavior. Results showed that the Tabor parameter derived from AFM analysis correlated well with experimentally determined attachment efficiency (α), which therefore is able to link microscale cell-surface properties with macroscale bacterial transport behavior. Results suggested that the AFM tests performed between a single cell and a surface captured the key quantities of the interactions between the cell and the surface that dictate overall cell attachment behavior. Tabor's parameter therefore can be potentially incorporated into the microbial transport model.


Assuntos
Aderência Bacteriana , Deltaproteobacteria/fisiologia , Gammaproteobacteria/fisiologia , Microscopia de Força Atômica/métodos , Modelos Biológicos , Bacillus cereus/fisiologia , Membrana Celular , Interações Hidrofóbicas e Hidrofílicas , Propriedades de Superfície
15.
Biomacromolecules ; 15(1): 283-90, 2014 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-24344625

RESUMO

Microfabrication technology provides a highly versatile platform for engineering hydrogels used in biomedical applications with high-resolution control and injectability. Herein, we present a strategy of microfluidics-assisted fabrication photo-cross-linkable gelatin microgels, coupled with providing protective silica hydrogel layer on the microgel surface to ultimately generate gelatin-silica core-shell microgels for applications as in vitro cell culture platform and injectable tissue constructs. A microfluidic device having flow-focusing channel geometry was utilized to generate droplets containing methacrylated gelatin (GelMA), followed by a photo-cross-linking step to synthesize GelMA microgels. The size of the microgels could easily be controlled by varying the ratio of flow rates of aqueous and oil phases. Then, the GelMA microgels were used as in vitro cell culture platform to grow cardiac side population cells on the microgel surface. The cells readily adhered on the microgel surface and proliferated over time while maintaining high viability (∼90%). The cells on the microgels were also able to migrate to their surrounding area. In addition, the microgels eventually degraded over time. These results demonstrate that cell-seeded GelMA microgels have a great potential as injectable tissue constructs. Furthermore, we demonstrated that coating the cells on GelMA microgels with biocompatible and biodegradable silica hydrogels via sol-gel method provided significant protection against oxidative stress which is often encountered during and after injection into host tissues, and detrimental to the cells. Overall, the microfluidic approach to generate cell-adhesive microgel core, coupled with silica hydrogels as a protective shell, will be highly useful as a cell culture platform to generate a wide range of injectable tissue constructs.


Assuntos
Gelatina/química , Técnicas Analíticas Microfluídicas/métodos , Dióxido de Silício/química , Engenharia Tecidual/métodos , Animais , Gelatina/administração & dosagem , Géis , Injeções , Camundongos , Camundongos Endogâmicos C57BL , Dióxido de Silício/administração & dosagem
16.
J Mech Behav Biomed Mater ; 22: 59-64, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23583634

RESUMO

When a contact lens is compressed between two parallel plates (PPC) or under a central load (CLC), the constitutive relation depends not only on the mechanical properties such as elastic modulus, E, of the hydrogel materials, but also the lens power, d, or thickness variation, h(ϕ0), along the meridional direction ϕ0. Hyperopic lenses (d>0) are thicker at the apex along the optical axis and thin out gradually along the meridian, while myopic lenses (d<0) are thinnest at the apex. Mechanical deformation is quantified by the inter-relationship between applied force, F, vertical displacement of the external load, w0, contact or dimple radius, a, and the deformed profile, w(r). Force responses show that lenses with positive d are apparently stiffer in the initial loading but become more compliant as load increases. Conversely, lenses with negative d are more deformable initially and becomes gradually more resistant to loading. This is consistent with the theoretical shell model using the same E. The mechanical behavior has significant impacts in defining the degree of comfort of contact lenses as well as the lens adhesion to the corneal epithelium.


Assuntos
Força Compressiva , Lentes de Contato , Hidrogéis , Teste de Materiais
17.
ACS Nano ; 7(3): 2369-80, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23363247

RESUMO

We engineered functional cardiac patches by seeding neonatal rat cardiomyocytes onto carbon nanotube (CNT)-incorporated photo-cross-linkable gelatin methacrylate (GelMA) hydrogels. The resulting cardiac constructs showed excellent mechanical integrity and advanced electrophysiological functions. Specifically, myocardial tissues cultured on 50 µm thick CNT-GelMA showed 3 times higher spontaneous synchronous beating rates and 85% lower excitation threshold, compared to those cultured on pristine GelMA hydrogels. Our results indicate that the electrically conductive and nanofibrous networks formed by CNTs within a porous gelatin framework are the key characteristics of CNT-GelMA leading to improved cardiac cell adhesion, organization, and cell-cell coupling. Centimeter-scale patches were released from glass substrates to form 3D biohybrid actuators, which showed controllable linear cyclic contraction/extension, pumping, and swimming actuations. In addition, we demonstrate for the first time that cardiac tissues cultured on CNT-GelMA resist damage by a model cardiac inhibitor as well as a cytotoxic compound. Therefore, incorporation of CNTs into gelatin, and potentially other biomaterials, could be useful in creating multifunctional cardiac scaffolds for both therapeutic purposes and in vitro studies. These hybrid materials could also be used for neuron and other muscle cells to create tissue constructs with improved organization, electroactivity, and mechanical integrity.


Assuntos
Miocárdio/citologia , Nanotubos de Carbono , Engenharia Tecidual , Alicerces Teciduais , Animais , Materiais Biomiméticos , Matriz Extracelular/metabolismo , Gelatina/química , Hidrogéis , Miocárdio/metabolismo , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Nanotecnologia , Ratos , Alicerces Teciduais/química
18.
Ann Biomed Eng ; 40(10): 2122-30, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22644532

RESUMO

This paper reports the first quantitative comparison study of elastic and viscoelastic properties of oocytes from young and aged mice. A force measurement technique, including a poly(dimethylsiloxane) (PDMS) cell holding device and a sub-pixel computer vision tracking algorithm, is utilized for measuring forces applied to an oocyte and resultant cell deformations in real time during oocyte manipulation. To characterize elastic and viscoelastic properties of the oocytes, a stress-relaxation indentation test is performed. A two-step, large-deformation mechanical model is developed to extract the mechanical properties of the oocytes from the measured force-deformation data. The experimental results demonstrate that the aged oocytes are significantly softer (instantaneous modulus: 2.2 vs. 5.2 kPa in young oocytes) but more viscous (relaxation time: 4.1 vs. 2.3 s in young oocytes) than the young oocytes.


Assuntos
Algoritmos , Elasticidade , Oócitos/química , Envelhecimento , Animais , Dimetilpolisiloxanos/química , Módulo de Elasticidade , Masculino , Camundongos , Camundongos Endogâmicos ICR , Oócitos/citologia
19.
Langmuir ; 28(16): 6677-83, 2012 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-22468932

RESUMO

The work of adhesion at the interface of electrospun membrane and rigid substrate is measured by a shaft-loaded blister test (SLBT). Poly(vinylidene fluoride) (PVDF) were electrospun with an average fiber diameter of 333 ± 59 nm. Commercial cardboard with inorganic coating was used to provide a model substrate for adhesion tests. In SLBT, the elastic response PVDF was analyzed and its adhesion energy measured. The average value of the adhesion work is 206 ± 26 mJ/m(2). Elastic modulus of electrospun membrane obtained by SLBT is found to be 23.42 ± 2.69 MPa, which is consistent with the value obtained from standard tensile tests. The results show SLBT presented a viable methodology for evaluating the adhesion energy of electrospun polymer fabrics.

20.
J Colloid Interface Sci ; 374(1): 70-6, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22360985

RESUMO

Macroscopic adhesion-aggregation, floc formation, and subsequent transportation of microorganisms in porous media are closely related to the microscopic behavior and properties of individual cells. The classical Tabor's parameter in colloidal science is modified to correlate the macroscopic aggregation and microscopic adhesion properties of microorganisms. Seven bacterial strains relevant to wastewater treatment and bioremediation were characterized in terms of their macroscopic aggregation index (AI) using an optical method, and their microscopic coupled adhesion and deformation properties using atomic force microscopy (AFM). Single cells were indented to measure the range and magnitude of the repulsive-attractive intersurface forces, elastic modulus, thickness and density of the cellular surface substances (CSS). The strong correlation suggests that cost and time effective microscopic AFM characterization is capable of making reliable prediction of macroscopic behavior.


Assuntos
Bactérias Aeróbias/química , Bactérias Anaeróbias/química , Membrana Celular/química , Bactérias Aeróbias/ultraestrutura , Bactérias Anaeróbias/ultraestrutura , Aderência Bacteriana , Biodegradação Ambiental , Fenômenos Biomecânicos , Módulo de Elasticidade , Microscopia de Força Atômica , Propriedades de Superfície , Eliminação de Resíduos Líquidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...