Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37820687

RESUMO

Objective. The goal of the study was to test the hypothesis that shoot-through FLASH proton beams would lead to lower dose-averaged LET (LETD) values in critical organs, while providing at least equal normal tissue sparing as clinical proton therapy plans.Approach. For five neurological tumor patients, pencil beam scanning (PBS) shoot-through plans were made, using the maximum energy of 227 MeV and assuming a hypothetical FLASH protective factor (FPF) of 1.5. The effect of different FPF ranging from 1.2 to 1.8 on the clinical goals were also considered. LETDwas calculated for the clinical plan and the shoot-through plan, applying a 2 Gy total dose threshold (RayStation 8 A/9B and 9A-IonRPG). Robust evaluation was performed considering density uncertainty (±3% throughout entire volume).Main results.Clinical plans showed large LETDvariations compared to shoot-through plans and the maximum LETDin OAR is 1.2-8 times lower for the latter. Although less conformal, shoot-through plans met the same clinical goals as the clinical plans, for FLASH protection factors above 1.4. The FLASH shoot-through plans were more robust to density uncertainties with a maximum OAR D2%increase of 0.6 Gy versus 5.7 Gy in the clinical plans.Significance.Shoot-through proton FLASH beams avoid uncertainties in LETDdistributions and proton range, provide adequate target coverage, meet planning constraints and are robust to density variations.


Assuntos
Neoplasias , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Transferência Linear de Energia , Prótons , Órgãos em Risco , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
2.
Phys Med Biol ; 66(6): 06NT01, 2021 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-33571981

RESUMO

PURPOSE: To discuss several pertinent issues related to shoot-through FLASH proton therapy based on an illustrative case. METHODS: We argue that with the advent of FLASH proton radiotherapy and due to the issues associated with conventional proton radiotherapy regarding the uncertainties of positioning of the Bragg peaks, the difficulties of in vivo verification of the dose distribution, the use of treatment margins and the uncertainties surrounding linear energy transfer (LET) and relative biological effectiveness (RBE), a special mode of shoot-through FLASH proton radiotherapy should be investigated. In shoot-through FLASH, the proton beams have sufficient energy to reach the distal exit side of the patient. Due to the FLASH sparing effect of normal tissues at both the proximal and distal side of tumors, radiotherapy plans can be developed that meet current planning constraints and issues regarding RBE can be avoided. RESULTS: A preliminary proton plan for a neurological tumor in close proximity to various organs at risk (OAR) with strict dose constraints was studied. A plan with four beams mostly met the constraints for the OAR, using a treatment planning system that was not optimized for this novel treatment modality. When new treatment planning algorithms would be developed for shoot-through FLASH, constraints would be easier to meet. The shoot-through FLASH plan led to a significant effective dose reduction in large parts of the healthy tissue. The plan had no uncertainties associated to Bragg peak positioning, needed in principle no large proximal or distal margins and LET increases near the Bragg peak became irrelevant. CONCLUSION: Shoot-through FLASH proton radiotherapy may be an interesting treatment modality to explore further. It would remove some of the current sources of uncertainty in proton radiotherapy. An additional advantage could be that portal dosimetry may be possible with beams penetrating the patient and impinging on a distally placed imaging detector, potentially leading to a practical treatment verification method. With current proton accelerator technology, trials could be conducted for neurological, head&neck and thoracic cancers. For abdominal and pelvic cancer a higher proton energy would be required.


Assuntos
Transferência Linear de Energia , Neoplasias/radioterapia , Órgãos em Risco , Terapia com Prótons/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Neoplasias/diagnóstico por imagem , Radioterapia (Especialidade) , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA