Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 47(1): 114-124, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33239154

RESUMO

The aim of the work described here was to evaluate the diagnostic performance of ultrasound thyroid computer-aided diagnosis (CAD) software. This multicenter prospective study included 494 patients (565 thyroid nodules) who underwent surgery or biopsy after ultrasonography at four hospitals from January 2019 to September 2019. The diagnostic performance metrics of different readers were calculated and compared with the pathologic results. The sensitivity of CAD was outstanding and was equivalent to that of a senior radiologist (90.51% vs. 88.47%, p > 0.05). The area under the curve of CAD was equivalent to that of a junior radiologist (0.748 vs. 0.739, p > 0.05). However, the specificity was only 49.63%, which was lower than those of the three radiologists (75.56%, 85.93% and 90.37% for the junior, intermediate and senior radiologists, respectively). The diagnostic performance of the junior radiologist was significantly improved with the aid of CAD (junior + CAD). The sensitivity and area under the curve of junior + CAD were improved from 72.20% to 89.93% and from 0.739 to 0.816, respectively (both p values <0.05), and the positive predictive value, negative predictive value and κ coefficient improved from 76.3% to 78.6%, 82.0% to 86.8% and 0.394 to 0.511, respectively. Though specificity slightly decreased from 75.56% to 73.33%, the difference was not statistically significant (p > 0.05). In general, the clinical application value of CAD is promising, and its instrumental value for junior radiologists is significant.


Assuntos
Competência Clínica , Diagnóstico por Computador , Radiologia , Software , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia
2.
Scand J Gastroenterol ; 52(4): 403-408, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28079407

RESUMO

OBJECTIVE: The objective of this study is to evaluate the gastric emptying in patients with systemic lupus erythematosus (SLE) with gastrointestinal involvement using three-dimensional (3D) ultrasonography. METHODS: The gastric emptying times at 25% (T1), 50% (T2), and 75% (T3) of SLE patients with gastrointestinal involvement (n = 40) and healthy controls (n = 80) were evaluated and compared. In addition, the correlations among the gastric wall thickness, SLE disease activity index (SLEDAI), and upper gastrointestinal symptoms were calculated. RESULTS: The gastric wall thickness was correlated with the SLEDAI (r = 0.928, p < 0.001) and the upper gastrointestinal symptom index (r = 0.848, p < 0.001). The emptying times T1, T2, and T3 of the SLE patients were 17.08 ± 2.65 min (mean ± standard deviation), 39.85 ± 6.54 min, and 83.58 ± 7.12 min, respectively. For healthy controls, they were 19.65 ± 5.39 min, 41.08 ± 7.51 min, and 70.34 ± 8.03 min. The T1 of the SLE patients was shorter (p < 0.01), while the T3 was longer (p < 0.001). Moreover, T3 in the SLE group had the best correlation with the upper gastrointestinal symptom index (r = 0.553, p < 0.001). T1 in the SLE group was anti-correlated with early satiety (r = -0.366, p < 0.05). CONCLUSIONS: Combining the emptying times T1 and T3, as well as the gastric wall thickness, the SLEDAI and the upper gastrointestinal symptoms index can provide accurate clinical diagnosis of SLE with gastric involvement.


Assuntos
Esvaziamento Gástrico , Lúpus Eritematoso Sistêmico/fisiopatologia , Estômago/diagnóstico por imagem , Estômago/patologia , Ultrassonografia , Adulto , Estudos de Casos e Controles , China , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
3.
Br J Radiol ; 89(1068): 20160366, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27759430

RESUMO

OBJECTIVE: Improvement in regional blood flow has been shown to ameliorate diabetic gastroparesis. We compared the gastric blood supply in patients with diabetes with gastroparesis with that in healthy subjects, by using contrast-enhanced ultrasound (CEUS). METHODS: 30 healthy subjects and 40 patients with diabetic gastroparesis were enrolled. The CEUS parameters of greater curvatures of the antrum (GCOA) and lesser curvatures of the antrum (LCOA), including peak intensity (PI) and the area under the curve (AUC), were compared between the two groups. RESULTS: Intraclass correlation coefficient (ICC) for PI in healthy subjects measured on CEUS were 0.831-0.857 and 0.803-0.823, respectively. Intra-ICC and inter-ICC values for AUC were 0.805-0.823 and 0.813-0.815, respectively. In both groups, no significant difference was observed in PI and AUC values of GCOA and LCOA (p > 0.05). The PI and AUC of GCOA and LCOA in the diabetes group were less than those in the normal group (p < 0.05). CONCLUSION: CEUS can assess stomach wall vascularity with a high reproducibility. Microcirculation in the antrum of patients with diabetic gastroparesis is poorer than that of normal group, which is consistent with the mechanisms of diabetic neuropathy. CEUS can be used for evaluation of microvascular perfusion in patients with stomach wall disease. Advances in knowledge: This was the first study to use CEUS for assessment of blood supply of the gastric wall and to compare microvascular perfusion between healthy individuals and patients with diabetes with gastroparesis.


Assuntos
Meios de Contraste , Complicações do Diabetes/diagnóstico por imagem , Gastroparesia/diagnóstico por imagem , Estômago/irrigação sanguínea , Estômago/diagnóstico por imagem , Ultrassonografia , Adulto , Área Sob a Curva , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
4.
Ultrasound Med Biol ; 40(9): 1998-2003, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25023116

RESUMO

In order to explore the accuracy of ultrasonic whole stomach cylinder measurement (UWSCM) in the evaluation of gastric emptying, we measured the gastric emptying times (ET) at 25% (T1), 50% (T2) and 75% (T3) of healthy subjects and patients with diabetic gastropathy by UWSCM and scintigraphy. The ET of patients were compared with their clinical symptom scores. We found that the ET measured by UWSCM showed no significant difference with scintigraphy (p > 0.05). The correlation between them was good, and the correlation coefficient of T3 reached 0.744 (p < 0.05). All emptying times in the diabetic patients were longer than those in the healthy subjects (p < 0.05). The T3 in the diabetic group measured by UWSCM had the best correlation with the symptom index (r = 0.469, p < 0.05). We conclude that ET measured by UWSCM is accurate and T3 combining the symptoms index provides an accurate clinical basis for gastropathy.


Assuntos
Diabetes Mellitus/fisiopatologia , Esvaziamento Gástrico/fisiologia , Estômago/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Reprodutibilidade dos Testes , Fatores de Tempo , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...