Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Chem ; 67(2): 922-951, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-38214982

RESUMO

Lysine specific demethylase 1 (LSD1), a transcriptional modulator that represses or activates target gene expression, is overexpressed in many cancer and causes imbalance in the expression of normal gene networks. Over two decades, numerous LSD1 inhibitors have been reported, especially some of which have entered clinical trials, including eight irreversible inhibitors (TCP, ORY-1001, GSK-2879552, INCB059872, IMG-7289, ORY-2001, TAK-418, and LH-1802) and two reversible inhibitors (CC-90011 and SP-2577). Most clinical LSD1 inhibitors demonstrated enhanced efficacy in combination with other agents. LSD1 multitarget inhibitors have also been reported, exampled by clinical dual LSD1/histone deacetylases (HDACs) inhibitors 4SC-202 and JBI-802. Herein, we present a comprehensive overview of the combination of LSD1 inhibitors with various antitumor agents, as well as LSD1 multitarget inhibitors. Additionally, the challenges and future research directionsare also discussed, and we hope this review will provide new insight into the development of LSD1-targeted anticancer agents.


Assuntos
Antineoplásicos , Neoplasias , Humanos , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Inibidores Enzimáticos/farmacologia , Inibidores Enzimáticos/uso terapêutico , Inibidores de Histona Desacetilases/farmacologia , Inibidores de Histona Desacetilases/uso terapêutico , Histona Desmetilases/metabolismo
2.
Pharmacol Ther ; 245: 108417, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37075933

RESUMO

With the booming development of precision medicine, molecular targeted therapy has been widely used in clinical oncology treatment due to a smaller number of side effects and its superior accuracy compared to that of traditional strategies. Among them, human epidermal growth factor receptor 2 (HER2)-targeted therapy has attracted considerable attention and has been used in the clinical treatment of breast and gastric cancer. Despite excellent clinical effects, HER2-targeted therapy remains in its infancy due to its resulting inherent and acquired resistance. Here, a comprehensive overview of HER2 in numerous cancers is presented, including its biological role, involved signaling pathways, and the status of HER2-targeted therapy.


Assuntos
Neoplasias da Mama , Resistencia a Medicamentos Antineoplásicos , Feminino , Humanos , Neoplasias da Mama/tratamento farmacológico , Terapia de Alvo Molecular/métodos , Transdução de Sinais
3.
J Neural Eng ; 15(3): 036002, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29485103

RESUMO

OBJECTIVE: Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device-tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. APPROACH: This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. MAIN RESULTS: Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm × 100 µm) and small probe (30 µm × 5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm × 200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm × 5 µm) to a smaller probe (30 µm × 5 µm) using the same polymer coating size (100 µm × 100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. SIGNIFICANCE: These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.


Assuntos
Implantes Absorvíveis/tendências , Córtex Cerebral/metabolismo , Eletrodos Implantados/tendências , Neuroglia/metabolismo , Polímeros/metabolismo , Xilenos/metabolismo , Implantes Absorvíveis/efeitos adversos , Animais , Córtex Cerebral/cirurgia , Eletrodos Implantados/efeitos adversos , Eletrodos Implantados/normas , Masculino , Microeletrodos/efeitos adversos , Microeletrodos/normas , Microeletrodos/tendências , Polímeros/síntese química , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Xilenos/síntese química
4.
Biomed Microdevices ; 17(2): 34, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25681971

RESUMO

We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.


Assuntos
Materiais Biocompatíveis/química , Teste de Materiais/métodos , Polímeros/química , Próteses e Implantes , Animais , Materiais Biocompatíveis/metabolismo , Encéfalo/embriologia , Interfaces Cérebro-Computador , Embrião de Galinha , Compostos de Epóxi/química , Microtecnologia , Cimento de Policarboxilato/química , Polímeros/metabolismo , Ratos Sprague-Dawley , Sefarose/química , Temperatura , Tirosina/química
5.
J Biomater Sci Polym Ed ; 20(5-6): 619-35, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19323880

RESUMO

We describe a series of fluorocarbon surfactant polymers designed as surface-modifying agents for improving the thrombogenicity of ePTFE vascular graft materials by the reduction of platelet adhesion. The surfactant polymers consist of a poly(vinyl amine) backbone with pendent dextran and perfluoroundecanoyl branches. Surface modification is accomplished by a simple dip-coating process in which surfactant polymers undergo spontaneous surface-induced adsorption and assembly on PTFE/ePTFE surface. The adhesion stability of the surfactant polymer on PTFE was examined under dynamic shear conditions in PBS and human whole blood with a rotating disk system. Fluorocarbon surfactant polymer coatings with three different dextran to perfluorocarbon ratios (1:0.5, 1:1 and 1:2) were compared in the context of platelet adhesion on PTFE/ePTFE surface under dynamic flow conditions. Suppression of platelet adhesion was achieved for all three coated surfaces over the shear-stress range of 0-75 dyn/cm2 in platelet-rich plasma (PRP) or human whole blood. The effectiveness depended on the surfactant polymer composition such that platelet adhesion on coated surfaces decreased significantly with increasing fluorocarbon branch density at 0 dyn/cm2. Our results suggest that fluorocarbon surfactant polymers can effectively suppress platelet adhesion and demonstrate the potential application of the fluorocarbon surfactant polymers as non-thrombogenic coatings for ePTFE vascular grafts.


Assuntos
Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biomiméticos/química , Materiais Biomiméticos/farmacologia , Polímeros de Fluorcarboneto/química , Polímeros de Fluorcarboneto/farmacologia , Adesividade Plaquetária/efeitos dos fármacos , Politetrafluoretileno/química , Tensoativos/química , Tensoativos/farmacologia , Materiais Biocompatíveis/síntese química , Materiais Biomiméticos/síntese química , Estabilidade de Medicamentos , Polímeros de Fluorcarboneto/síntese química , Humanos , Técnicas In Vitro , Teste de Materiais , Microscopia de Fluorescência , Modelos Moleculares , Estrutura Molecular , Ativação Plaquetária/efeitos dos fármacos , Tensoativos/síntese química
6.
J Biomater Sci Polym Ed ; 15(1): 95-110, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15027845

RESUMO

We report on a series of structurally well-defined surfactant polymers that undergo surface-induced self-assembly on hydrophobic biomaterial surfaces. The surfactant polymers consist of a poly(vinyl amine) backbone with poly(ethylene oxide) and hexanal pendant groups. The poly(vinyl amine) (PVAm) was synthesized by hydrolysis of poly(N-vinyl formamide) following free radical polymerization of N-vinyl formamide. Hexanal and aldehyde-terminated poly(ethylene oxide) (PEO) were simultaneously attached to PVAm via reductive amination. Surfactant polymers with different PEO:hexanal ratios and hydrophilic/hydrophobic balances were prepared, and characterized by FT-IR, 1H-NMR and XPS spectroscopies. Surface active properties at the air/water interface were determined by surface tension measurements. Surface activity at a solid surface/water interface was demonstrated by atomic force microscopy, showing epitaxially molecular alignment for surfactant polymers adsorbed on highly oriented pyrolytic graphite. The surfactant polymers described in this report can be adapted for simple non-covalent surface modification of biomaterials and hydrophobic surfaces to provide highly hydrated interfaces.


Assuntos
Polietilenoglicóis/química , Polímeros/síntese química , Tensoativos/síntese química , Aldeídos/análise , Aldeídos/química , Materiais Revestidos Biocompatíveis/química , Microanálise por Sonda Eletrônica , Grafite/química , Interações Hidrofóbicas e Hidrofílicas , Espectroscopia de Ressonância Magnética , Microscopia de Força Atômica , Modelos Moleculares , Estrutura Molecular , Peso Molecular , Polietilenoglicóis/síntese química , Polímeros/química , Polivinil/síntese química , Polivinil/química , Espectroscopia de Infravermelho com Transformada de Fourier , Tensão Superficial , Tensoativos/química , Água/química
7.
Macromolecules ; 37(9): 3353-3359, 2004 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-16429594

RESUMO

We describe a series of fluorocarbon surfactant polymers designed for modifying fluorocarbon surfaces such as poly(tetrafluoroethylene). Novel fluorocarbon surfactant polymers poly(N-vinyldextranaldonamide-co-N-vinylperfluoroundecanamide), in which hydrophilic dextran oligosaccharides and hydrophobic perfluoroundecanoyl groups were incorporated sequentially onto a poly(vinylamine) backbone, were synthesized and characterized by FT-IR, NMR, and XPS spectroscopy. By adjusting the feed ratio of dextran to fluorocarbon branches, surfactant polymers with different hydrophilic/hydrophobic balances were prepared. The surface activity of the surfactants at the air/water interface was demonstrated by significant reductions in water surface tension. Surfactant adsorption and adhesion at the solid PTFE/aqueous interface were examined under well-defined dynamic flow conditions, using a rotating disk system. The surface activity at the air/water interface and adhesion stability on PTFE under an applied shear stress both increase with increasing density of fluorocarbon branches on the polymer backbone. The results show that stable surfactant adhesion on PTFE can be achieved by adjusting the hydrophilic dextran to hydrophobic fluorocarbon branch ratio.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA