Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mult Scler Relat Disord ; 85: 105527, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38432014

RESUMO

OBJECTIVE: The differential diagnosis between autoimmune glial fibrillary acidic protein astrocytopathy (AGFAPA) mimicking tuberculous meningitis and tuberculous meningitis (TBM) remains challenging in clinical practice. This study aims to identify the clinical, laboratory parameters, and clinical score systems that may be helpful in differentiating AGFAPA from TBM. METHOD: Overall 22 AGFAPA patients who were initially misdiagnosed as TBM (AGFAPA-TBM) and 30 confirmed TBM patients were included. The clinical, laboratory, imaging parameters, Thwaites systems, and Lancet consensus scoring systems (LCSS) of all patients were reviewed. Logistic regression was employed to establish a diagnostic formula to differentiate AGFAPA-TBM from TBM. The receiver operating characteristic (ROC) curve was applied to determine the best diagnostic critical point of the formula. RESULTS: Urinary retention was more frequent in AGFAPA-TBM patients (72.7% vs 33.3%, p = 0.012). A significantly lower ratio of T-SPOT. TB was noted in AGFAPA-TBM patients (9.1% vs 82.1%, p < 0.001). We found the LCSS was able to differentiate AGFAPA-TBM from TBM (AUC value 0.918, 95% CI=0.897-0.924). Furthermore, we set up a new scoring system with three variables: urinary retention, T-SPOT. TB, and cerebral imaging criteria in LCSS. The proposed diagnostic score ranges from -8 to 2, and a score of ≥ 0 was suggestive of AGFAPA-TBM (AUC value 0.938, 95% CI=0.878-0.951). CONCLUSIONS: This study is the first to evaluate the Thwaites system and LCSS in AGFAPA-TBM and TBM. We provide an alternative diagnostic formula to differentiate AGFAPA-TBM from TBM and suggest testing for GFAP antibodies to avoid misdiagnosis when this scoring system meets AGFAPA-TBM.


Assuntos
Proteína Glial Fibrilar Ácida , Tuberculose Meníngea , Humanos , Tuberculose Meníngea/diagnóstico , Feminino , Masculino , Diagnóstico Diferencial , Proteína Glial Fibrilar Ácida/imunologia , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Estudos Retrospectivos , Doenças Autoimunes do Sistema Nervoso/diagnóstico , Doenças Autoimunes do Sistema Nervoso/imunologia , Astrócitos/imunologia , Autoanticorpos/sangue
2.
Phys Rev Lett ; 126(21): 211803, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34114849

RESUMO

We report constraints on light dark matter through its interactions with shell electrons in the PandaX-II liquid xenon detector with a total 46.9 tonnes/day exposure. To effectively search for these very low energy electron recoils, ionization-only signals are selected from the data. 1821 candidates are identified within an ionization signal range between 50 and 75 photoelectrons, corresponding to a mean electronic recoil energy from 0.08 to 0.15 keV. The 90% C.L. exclusion limit on the scattering cross section between the dark matter and electron is calculated with systematic uncertainties properly taken into account. Under the assumption of point interaction, we provide the world's most stringent limit within the dark matter mass range from 15 to 30 MeV/c^{2}, with the corresponding cross section from 2.5×10^{-37} to 3.1×10^{-38} cm^{2}.

3.
Phys Rev Lett ; 121(2): 021304, 2018 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-30085724

RESUMO

We search for nuclear recoil signals of dark matter models with a light mediator in PandaX-II, a direct detection experiment in the China Jinping underground laboratory. Using data collected in 2016 and 2017 runs, corresponding to a total exposure of 54 ton day, we set upper limits on the zero-momentum dark matter-nucleon cross section. These limits have a strong dependence on the mediator mass when it is comparable to or below the typical momentum transfer. We apply our results to constrain self-interacting dark matter models with a light mediator mixing with standard model particles, and set strong limits on the model parameter space for the dark matter mass ranging from 5 GeV to 10 TeV.

4.
Phys Rev Lett ; 119(18): 181806, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219572

RESUMO

We report new searches for solar axions and galactic axionlike dark matter particles, using the first low-background data from the PandaX-II experiment at China Jinping Underground Laboratory, corresponding to a total exposure of about 2.7×10^{4} kg day. No solar axion or galactic axionlike dark matter particle candidate has been identified. The upper limit on the axion-electron coupling (g_{Ae}) from the solar flux is found to be about 4.35×10^{-12} in the mass range from 10^{-5} to 1 keV/c^{2} with 90% confidence level, similar to the recent LUX result. We also report a new best limit from the ^{57}Fe deexcitation. On the other hand, the upper limit from the galactic axions is on the order of 10^{-13} in the mass range from 1 to 10 keV/c^{2} with 90% confidence level, slightly improved compared with the LUX.

5.
Phys Rev Lett ; 119(18): 181302, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219592

RESUMO

We report a new search for weakly interacting massive particles (WIMPs) using the combined low background data sets acquired in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live days, with the background reduced to a level of 0.8×10^{-3} evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events are found above the expected background. With a total exposure of 5.4×10^{4} kg day, the most stringent upper limit on the spin-independent WIMP-nucleon cross section is set for a WIMP with mass larger than 100 GeV/c^{2}, with the lowest 90% C.L. exclusion at 8.6×10^{-47} cm^{2} at 40 GeV/c^{2}.

6.
Phys Rev Lett ; 118(7): 071301, 2017 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-28256892

RESUMO

New constraints are presented on the spin-dependent weakly-interacting-massive-particle–- (WIMP-)nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3×10^{4} kg day. Assuming a standard axial-vector spin-dependent WIMP interaction with ^{129}Xe and ^{131}Xe nuclei, the most stringent upper limits on WIMP-neutron cross sections for WIMPs with masses above 10 GeV/c^{2} are set in all dark matter direct detection experiments. The minimum upper limit of 4.1×10^{-41} cm^{2} at 90% confidence level is obtained for a WIMP mass of 40 GeV/c^{2}. This represents more than a factor of 2 improvement on the best available limits at this and higher masses. These improved cross-section limits provide more stringent constraints on the effective WIMP-proton and WIMP-neutron couplings.

7.
Phys Rev Lett ; 117(12): 121303, 2016 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-27689262

RESUMO

We report the weakly interacting massive particle (WIMP) dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing underground laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3×10^{4} kg day, the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 5 and 1000 GeV/c^{2}. The best upper limit on the scattering cross section is found 2.5×10^{-46} cm^{2} for the WIMP mass 40 GeV/c^{2} at 90% confidence level.

8.
J Colloid Interface Sci ; 337(1): 278-84, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19540510

RESUMO

A series of palmitoyl chloride-grafted hyperbranched polyglycerols were synthesized through cationic ring-opening polymerization and end-group modification. The obtained grafted copolymer of HPG-C16 possesses a hydrophilic hyperbranched polyether core and many hydrophobic alkyl arms, which shows interesting self-assembly behavior in THF and water. The results indicate that the copolymers with a relatively high alkyl grafting ratio can form unimolecular micelles in THF and will further assemble into giant vesicles around 1-10 microm in THF/water mixed solvents. However, the HPG-C16 with a low alkyl grafting ratio of 15.6% can directly assemble into vesicles in THF and form micelles in water.


Assuntos
Glicerol/química , Palmitatos/química , Polímeros/química , Espectroscopia de Ressonância Magnética , Microscopia Eletrônica de Transmissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...