Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 10(11)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38002442

RESUMO

Dental caries on the crown's surface is caused by the interaction of bacteria and carbohydrates, which then gradually alter the tooth's structure. In addition, calculus is the root of periodontal disease. Optical coherence tomography (OCT) has been considered to be a promising tool for identifying dental caries; however, diagnosing dental caries in the early stage still remains challenging. In this study, we proposed an ultrahigh-resolution OCT (UHR-OCT) system with axial and transverse resolutions of 2.6 and 1.8 µm for differentiating the early-stage dental caries and calculus. The same teeth were also scanned by a conventional spectral-domain OCT (SD-OCT) system with an axial resolution of 7 µm. The results indicated that early-stage carious structures such as small cavities can be observed using UHR-OCT; however, the SD-OCT system with a lower resolution had difficulty identifying it. Moreover, the estimated surface roughness and the scattering coefficient of enamel were proposed for quantitatively differentiating the different stages of caries. Furthermore, the thickness of the calculus can be estimated from the UHR-OCT results. The results have demonstrated that UHR-OCT can detect caries and calculus in their early stages, showing that the proposed method for the quantitative evaluation of caries and calculus is potentially promising.

2.
Diagnostics (Basel) ; 12(4)2022 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-35453872

RESUMO

Fractional laser treatment is commonly used for dermatological applications, enabling effective induction of collagen regeneration and significantly reducing recovery time. However, it is challenging to observe laser-induced photodamage beneath the tissue surface in vivo, making the non-invasive evaluation of treatment outcomes difficult. For in vivo real-time study of the photodamage induced by fractional pulsed CO2 and Nd:YAG lasers commonly utilized for clinical therapy, a portable spectral-domain optical coherence tomography (SD-OCT) system was implemented for clinical studies. The photodamage caused by two lasers, including photothermal and photoacoustic effects, was investigated using OCT, together with the correlation between photodamage and exposure energy. Additionally, to investigate the change in the optical properties of tissue due to photodamage, the attenuation coefficients and damaged areas of normal skin and laser-treated skin were estimated for comparison. Finally, the recovery of the exposed skin with both lasers was also compared using OCT. The results show that OCT can be a potential solution for in vivo investigation of laser-induced tissue damage and quantitative evaluation.

3.
Biomed Opt Express ; 12(7): 3851-3864, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34457384

RESUMO

We demonstrate computational multi-directional optical coherence tomography (OCT) to assess the directional property of tissue microstructure. This method is the combination of phase-sensitive volumetric OCT imaging and post-signal processing. The latter comprises of two steps. The first step is an intensity-directional analysis, which determines the dominant en face fiber orientations. The second step is the phase-directional imaging, which reveals the sub-resolution depth-orientation of the microstructure. The feasibility of the method was tested by assessing muscle and tendon samples. Stripe patterns with several sizes were visualized in the phase-directional images. In order to interpret these images, the muscle and tendon structures were numerically modeled, and the phase-directional images were generated from the numerical model. The similarity of the experimental and numerical results suggested that the stripe patterns correspond to the muscle fiber bundle and its crimping.

4.
Biomed Opt Express ; 10(11): 5687-5702, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31799040

RESUMO

In this study, a Q-switch pumped supercontinuum laser (QS-SCL) is used as a light source for in vivo imaging via ultrahigh-resolution optical coherence tomography and angiography (UHR-OCT/OCTA). For this purpose, an OCT system based on a spectral-domain detection scheme is constructed, and a spectrometer with a spectral range of 635 - 875 nm is designed. The effective full-width at half maximum of spectrum covers 150 nm, and the corresponding axial and transverse resolutions are 2 and 10 µm in air, respectively. The relative intensity noise of the QS-SCL and mode-locked SCL is quantitatively compared. Furthermore, a special processing algorithm is developed to eliminate the intrinsic noise of QS-SCL. This work demonstrates that QS-SCLs can effectively reduce the cost and size of UHR-OCT/OCTA instruments, making clinical applications feasible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...