Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Opt Lett ; 49(11): 3234-3237, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824371

RESUMO

We demonstrate a milli-Newton mechanical force sensor based on a whispering gallery mode microbottle resonator (MBR). A lever model is established by coupling the MBR with a tapered fiber, whose ratio of load arm to effort arm (RLE) is flexibly adjusted to enlarge the detection range. The mechanical force is induced by attaching a capillary on the MBR stem and applying the downward displacement, which deforms the MBR's radius and thus shifts the resonance wavelength. The dependence of the capillary displacement on the mechanical force is theoretically deduced and verified. Experimentally, the sensors with different RLEs are built, and the maximum sensitivity of -10.48 pm/mN with a resolution of 40 µN is obtained. The achieved detection range is 0-4 mN, which depends on the capillary displacement and RLE of the lever. With the merits of easy fabrication and flexible structure, the proposed sensor shows great potential in biomedical and structural health monitoring.

2.
Opt Express ; 32(11): 18639-18649, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38859015

RESUMO

In this paper, we propose and demonstrate an all-optical control of RSB transition in a multi-wavelength Brillouin random fiber laser (MWBRFL). Multi-order Stokes light components can be subsequently generated by increasing the power of the Erbium-doped fiber amplifier (EDFA) inside the MWBRFL, providing additional disorder as well as multiple Stokes-involved interplay. It essentially allows diversified laser mode landscapes with adjustable average mode lifetime and random mode density of the 1st order Stokes, which benefits the switching between replica symmetry breaking (RSB) and replica symmetry (RS) states in an optically controlled manner. Results show that the average mode lifetime of the 1st order Stokes component gradually decreases from 250.0 ms to 1.2 ms as high orders from the 2nd to the 5th of Stokes components are activated. Meanwhile, the order parameter q of the 1st order Stokes random lasing emission presents distinct statistical distributions within the selective sub-window under various EDFA optical powers. Consequently, all-optical dynamical control of the 1st Stokes random laser mode landscapes with adjustable average mode lifetime turns out to be attainable, facilitating the RSB transition under an appropriate observation time window. These findings open a new avenue for exploring the underlying physical mechanisms behind the occurrence of the RSB phenomenon in photonic complex systems.

3.
Opt Lett ; 49(9): 2369-2372, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691721

RESUMO

Perfluorinated acrylate polymer materials exhibit low absorption loss at 1310 and 1550 nm, but molecular oxygen inhibits their photocuring. We propose a novel, to our knowledge, UV photolithography method incorporating a pre-exposure process for fabricating low-loss perfluorinated acrylate polymer waveguides. During the pre-exposure process, a partially cured thin layer forms on the core layer, effectively overcoming oxygen inhibition in subsequent lithography. Furthermore, the functional group contents of the polymerized materials were characterized by a Raman spectrometer to analyze the development reaction under the pre-exposure layer. Utilizing this improved method, we fabricated a straight waveguide with a length of 21 cm. The experiments showed that the propagation losses are 0.14 dB/cm at 1310 nm and 0.51 dB/cm at 1550 nm. The inter-channel cross talk for a core pitch of 250 µm was measured as low as -49 dB at 1310 nm. Error-free NRZ data transmission over this waveguide at 25 Gb/s was achieved, showcasing the potential in optical interconnect and communication applications.

4.
Opt Lett ; 49(7): 1753-1756, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560854

RESUMO

Current or magnetic field sensing is usually achieved by exploiting the Faraday effect of an optical material combined with an interferometric probe that provides the sensitivity. Being interferometric in nature, such sensors are typically sensitive to several other environmental parameters such as vibrations and mechanical disturbances, which, however, inevitably impose the inaccuracy and instability of the detection. Here we demonstrate a polarimetric fiber optic current sensor based on orbital angular momentum modes of an air-core optical fiber. In the fiber, spin-orbit interactions imply that the circular birefringence, which is sensitive to applied currents or resultant magnetic fields, is naturally resilient to mechanical vibrations. The sensor, which effectively measures polarization rotation at the output of a fiber in a magnetic field, exhibits high linearity in the measured signal versus the applied current that induces the magnetic field, with a sensitivity of 0.00128 rad/A and a noise limit of 1×10-5/H z. The measured polarization varies within only ±0.1% under mechanical vibrations with the frequency of up to 800 Hz, validating the robust environmental performance of the sensor.

5.
Opt Express ; 32(7): 11726-11736, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38571013

RESUMO

A distributed optical fiber magnetic field sensor based on a polarization-sensitive optical frequency domain reflectometer (POFDR) is proposed. It extracts the accumulated Faraday rotation by combining the Stokes vectors and the backward Mueller matrices from the measured states of polarization (SOPs) and obtains the magnetic field component. This method avoids adjusting the input polarization during the magnetic field sensing process. It overcomes the drawback of the conventional POFDR scheme, which requires at least two sets of different input SOPs for each sensing. Finally, the aforementioned effectiveness has been experimentally verified by using a single-mode sensing fiber. The results show that the sensor has good repeatability and linearity. The measurement error of the magnetic field sensor is 19.4 mT. The measured magnetic field variations agree with the applied ones with similarities higher than 0.98.

6.
Opt Express ; 32(6): 8723-8735, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571123

RESUMO

In this study, a Si defect structure was added into the silica network in order to activate the bismuth and silica structure active center. TD-DFT theoretical simulations show that the Bi and Si ODC(I) models can excite the active center of the E-band at 1408 nm. Additionally, the Bi-doped silica fiber (BDSF) with improved fluorescence was fabricated using atomic layer deposition (ALD) combined with the modified chemical vapor deposition (MCVD) technique. Some tests were used to investigate the structural and optical properties of BDSF. The UV-VIS spectral peak of the BDSF preform is 424 cm-1, and the binding energy of XPS is 439.3 eV, indicating the presence of Bi° atom in BDSF. The Raman peak near 811 cm-1 corresponds to the Bi-O bond. The Si POL defect lacks a Bi-O structure, and the reason for the absence of simulated active center from the E-band is explained. A fluorescence spectrometer was used to analyze the emission peak of a BDSF at 1420 nm. The gain of the BDSF based optical amplifier was measured 28.8 dB at 1420 nm and confirmed the effective stimulation of the bismuth active center in the E-band.

7.
Opt Express ; 32(6): 8937-8949, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571139

RESUMO

In this study, PbS/Er co-doped fibers (PEDFs) were fabricated by atomic layer deposition (ALD) combined with modified chemical vapor deposition (MCVD). A pumping scheme based on two-photon absorption at 1310 nm of PEDF is proposed for L + band amplification. Through the theoretical analysis, the local environment of Er3+ is changed due to the co-doping of PbS, which improves the two-photon absorption efficiency near 1300 nm. Compared with the 980 nm pump, the PEDFs excited by the 1310 nm pump show better amplification performance in the L + band. And in a bi-directional pumping system, PEDF achieves over 22 dB of gain in the whole L band. In particular, the bandwidth of over 20 dB gain was extended to 1627 nm with a noise figure as low as 4.9 dB. To the best of our knowledge, this is the first time that a high-gain bandwidth of L band amplification has been extended to 1627 nm. The results of unsaturated loss also show that PbS co-doping improves the two-photon absorption efficiency of PEDF to broaden the amplification bandwidth of L + band. These results demonstrate that an effective L + band amplification method is practically provided for future ultra-wideband optical communications.

8.
Opt Express ; 32(5): 7540-7552, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38439432

RESUMO

A design of a heterogeneous integrated optical fiber with side nickel core (SNCF) has been proposed and demonstrated for distributed fiber-optic magnetic field sensing. Experimental results show that magnetic properties of nickel can be preserved well after the high temperature drawing process. The functionality of the SNCF has been well verified, with the sensitivity for DC magnetic field being up to -2.42 µÎµ/mT (below 8 mT). Besides, the SNCF finally presents magnetostriction saturation under a certain magnetic field, which agrees with the simulation. The proposed direct thermal drawing method to produce metal-heterogeneous integrated optical fiber paves the way for a simple and scalable means of incorporating metallic materials into fibers, as well as providing a promising candidate for long-distance distributed magnetic field sensing.

9.
Biomaterials ; 306: 122505, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38359507

RESUMO

Atherosclerosis, a chronic inflammatory disease, is the primary cause of myocardial infarction and ischemic stroke. Recent studies have demonstrated that dysregulation of yes-associated protein (YAP) and transcriptional coactivator with PDZ-binding domain (TAZ) contributes to plaque development, making YAP/TAZ potential therapeutic targets. However, systemic modulation of YAP/TAZ expression or activities risks serious off-target effects, limiting clinical applicability. To address the challenge, this study develops monocyte membrane-coated nanoparticles (MoNP) as a targeted delivery system for activated and inflamed endothelium lining the plaque surface. The MoNP system is used to deliver verteporfin (VP), aimed at inhibiting YAP/TAZ specifically within arterial regions prone to atherosclerosis. The results reveal that MoNP significantly enhance payload delivery to inflamed endothelial cells (EC) while avoiding phagocytic cells. When administered in mice, MoNP predominantly accumulate in intima of the atheroprone artery. MoNP-mediated delivery of VP substantially reduces YAP/TAZ expression, thereby suppressing inflammatory gene expression and macrophage infiltration in cultured EC and mouse arteries exposed to atherogenic stimuli. Importantly, this targeted VP nanodrug effectively decreases plaque development in mice without causing noticeable histopathological changes in major organs. Collectively, these findings demonstrate a lesion-targeted and pathway-specific biomimetic nanodrug, potentially leading to safer and more effective treatments for atherosclerosis.


Assuntos
Aterosclerose , Placa Aterosclerótica , Animais , Camundongos , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Transativadores/metabolismo , Proteínas de Sinalização YAP , Células Endoteliais/metabolismo , Biomimética , Aterosclerose/tratamento farmacológico , Aterosclerose/patologia , Inflamação/tratamento farmacológico
10.
Opt Express ; 32(1): 586-598, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38175084

RESUMO

We numerically and experimentally demonstrated a high-sensitivity and high-accuracy temperature sensor based on guided acoustic radial modes of forward stimulated Brillouin scattering (FSBS)-based optomechanics in thin-diameter fibers (TDF). The dependence of the FSBS-involved electrostrictive force on the fiber diameter is systematically investigated. As the diameters of the fiber core and cladding decrease, the intrinsic frequency of each activated acoustic mode and corresponding FSBS gain are expected to be accordingly increased, which benefits the significant enhancement of its temperature sensitivity as well as the optimization of the measurement accuracy. In validations, by utilizing TDFs with fiber diameters of 80 µm and 60 µm, the proof-of-concept experiments proved that sensitivities of the TDF-based FSBS temperature sensor with radial modes from R0,4 to R0,15 increased from 35.23 kHz/°C to 130.38 kHz/°C with an interval of 8.74 kHz/°C. The minimum measurement error (i.e., 0.15 °C) of the temperature sensor with the 60 µm-TDF is 2.5 times lower than that of the 125 µm-SSMF (i.e., 0.39 °C). The experimental and simulated results are consistent with theoretical predictions. It is believed that the proposed approach with high sensitivity and accuracy could find potential in a wide range of applications such as environmental monitoring, chemical engineering, and cancer detection in human beings.

11.
Appl Opt ; 62(35): 9326-9333, 2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38108704

RESUMO

To enhance the capability of phase-sensitive optical time domain reflectometers (Φ-OTDR) to recognize disturbance events, an improved adaptive feature extraction method based on NMF-MFCC is proposed, which replaces the fixed filter bank used in the traditional method to extract the mel-frequency cepstral coefficient (MFCC) features by a spectral structure obtained from the Φ-OTDR signal spectrum using nonnegative matrix factorization (NMF). Three typical events on fences are set as recognition targets in our experiments, and the results show that the NMF-MFCC features have higher distinguishability, with the corresponding recognition accuracy reaching 98.47%, which is 7% higher than that using the traditional MFCC features.

12.
Nanotechnology ; 35(10)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37995361

RESUMO

In this study, platinum (Pt) and tungsten (W), two materials with dissimilar coefficients of thermal expansion (CTE) and work functions (WF), are used as the top electrode (TE) and the bottom electrode (BE) in metal/ferroelectric/metal (MFM) structures to explore the ferroelectricity of hafnium zirconium oxide (HZO) with a thickness less than 10 nm. The electrical measurements indicate that a higher CTE mismatch between HZO and TE/BE is beneficial for enhancing the ferroelectric properties of nanoscale HZO thin films. The different WFs of TE and BE generate a built-in electric field in the HZO layer, leading to shifts in the hysteresis loops and the capacitance-voltage characteristics. The structural characterizations reveal that the preferred formation of the orthorhombic phase in HZO is dominated by the W BE. The device in which W is used as the TE and BE (the W/HZO/W MFM structure) presents the optimal ferroelectric performance of a high remanent polarization (2Pr= 55.2µC cm-2). The presence of tungsten oxide (WOx) at the W/HZO interfaces, as revealed by high-resolution transmission microscopy, is also responsible for the enhancement of ferroelectric properties. This study demonstrates the significant effects of different CTEs and WFs of TE and BE on the properties of ferroelectric HZO thin films.

13.
Appl Opt ; 62(25): 6809-6815, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37706815

RESUMO

An extrinsic fiber optic Fabry-Perot interferometric (EFPI) ultrasonic sensor based on a grooved silicon diaphragm for partial discharge (PD) detection has been proposed. The size of the groove is determined by finite element simulation, which allows the resonant frequency of the sensor to meet the requirements of PD ultrasonic detection and improves the sensitivity of the sensor by 5.07 times compared with that based on a traditional circular diaphragm. The microelectro-mechanical system process is used to fabricate the diaphragm on a silicon-on-insulator wafer, and the prepared diaphragm has a grooved section with a diameter of 829.34 µm and a thickness of only 2.09 µm. At its resonant frequency of 61.5 kHz, the acoustic pressure sensitivity of the sensor is 172.42 mV/Pa. The ultrasonic signal detection capability of the sensor is verified in the PD experiment. Furthermore, the characteristics of the corona discharge are successfully manifested based on the ultrasonic waves detected by the EFPI sensor. It is demonstrated that the proposed sensor is suitable for PD detection due to its high sensitivity, simple production process, and good resistance to environmental interference.

14.
Adv Sci (Weinh) ; 10(32): e2302770, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37759405

RESUMO

Atomic layer engineering is investigated to tailor the morphotropic phase boundary (MPB) between antiferroelectric, ferroelectric, and paraelectric phases. By increasing the HfO2 seeding layer with only 2 monolayers, the overlying ZrO2 layer experiences the dramatic phase transition across the MPB. Conspicuous ferroelectric properties including record-high remanent polarization (2Pr ≈ 60 µC cm-2 ), wake-up-free operation, and high compatibility with advanced semiconductor technology nodes, are achieved in the sub-6 nm thin film. The prominent antiferroelectric to ferroelectric phase transformation is ascribed to the in-plane tensile stress introduced into ZrO2 by the HfO2 seeding layer. Based on the high-resolution and high-contrast images of surface grains extracted precisely by helium ion microscopy, the evolution of the MPB between tetragonal, orthorhombic, and monoclinic phases with grain size is demonstrated for the first time. The result indicates that a decrease in the average grain size drives the crystallization from the tetragonal to polar orthorhombic phases.

15.
Opt Lett ; 48(16): 4412-4415, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37582045

RESUMO

We demonstrate a diaphragm-integrated ring waveguide coupler fabricated by the two-photon direct laser wring technique as an ultrasonic sensor, which is integrated on an optical fiber tip. The device consists of a micro-ring waveguide with a diameter of 5 µm functionalized as an optical fiber tip light reflection mirror and a straight waveguide connecting a diaphragm. The evanescent field coupling can be realized between the two waveguides, and the coupling efficiency can be changed due to the variation of the coupling gap induced by ultrasound. Accordingly, the light reflection can be changed. Based on the plate vibration theory, the vibration frequency can be changed through optimizing the diaphragm size. The experiments show that the device exhibits a high sensitivity and low noise equivalent acoustic signal level of 1.07 mPa/Hz1/2 at 100 kHz, which has great potential in various acoustic wave sensing applications.

16.
Opt Express ; 31(15): 23754-23767, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37475219

RESUMO

The interlayer distance optimized for low-loss and low-crosstalk double-layer polymer optical waveguides was investigated to enhance their transmission performance. Simulations were conducted to determine the minimal interlayer distances for double-layer optical waveguides with different core sizes. An optimal interlayer distance of 24 µm was identified for a 20 µm × 20 µm double-layer waveguide, which ensured interlayer crosstalk below -30 dB when roughness remained under 80 nm. The double-layer waveguides were fabricated employing ultraviolet lithography combined with the overlay alignment method. Based on experimental optimization, the important fabrication parameters were optimized, such as a plasma treatment time of 10 s, a core exposure dose of 500 mJ/cm2, and a cladding exposure dose of 240 mJ/cm2. Additionally, the fabricated double-layer waveguides, with an interlayer distance of 24.5 µm, exhibited low transmission losses of less than 0.25 dB/cm at 850 nm and 0.40 dB/cm at 1310 nm, respectively. The low interlayer crosstalk values were less than -52 dB at 850 nm and -60 dB at 1310 nm, respectively. The agreement between the experimental results and the simulation findings indicates that this method offers a promising approach for fabricating double-layer waveguides with good performances.

17.
Opt Express ; 31(15): 24623-24632, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37475284

RESUMO

An all-fiber fiber coupler was demonstrated for pumping orbital angular momentum (OAM) modes amplification, which was fabricated by side-polishing and bonding a ring-core erbium-doped fiber (RC-EDF) and a pre-tapered side-polished single-mode fiber (SMF). With the selected phase-matching condition at 976 nm, the pumping laser was coupled into the RC-EDF from the SMF with optimized high efficiency, whereas the 1st to 3rd-order OAM mode signals were transmitted with the low insertion loss in the RC-EDF over a broadband wavelength range from 1530 to 1565 nm. This all-fiber wavelength division multiplexing coupler was optimized by the polished length and depth of the two coupled fibers. The insertion loss for the OAM signal modes was obtained lower than 0.58 dB with the pump power coupling ratio of above 90%. The proposed side-polished pumping coupler technique can ensure high-order OAM modes amplification, paving the way for the all-fiber optical amplifier in high-capacity modal-division multiplexing fiber communication systems.

18.
J Neural Transm (Vienna) ; 130(10): 1291-1302, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37418038

RESUMO

Although depressive symptoms are common in PD, few studies investigated sex and age differences in depressive symptoms. Our study aimed to explore the sex and age differences in the clinical correlates of depressive symptoms in patients with PD. 210 PD patients aged 50-80 were recruited. Levels of glucose and lipid profiles were measured. The Hamilton Depression Rating Scale-17 (HAMD-17), the Montreal Cognitive Assessment (MoCA) and the Movement Disorder Society Unified Parkinson's Disease Rating Scale Part III (MDS-UPDRS-III) assessed depressive symptom, cognition and motor function, respectively. Male depressive PD participants had higher fasting plasma glucose (FPG) levels. Regarding the 50-59 years group, depressive patients had higher TG levels. Moreover, there were sex and age differences in the factors associated with severity of depressive symptoms. In male PD patients, FPG was an independent contributor to HAMD-17 (Beta = 0.412, t = 4.118, p < 0.001), and UPDRS-III score was still associated with HAMD-17 in female patients after controlling for confounding factors (Beta = 0.304, t = 2.961, p = 0.004). Regarding the different age groups, UPDRS-III (Beta = 0.426, t = 2.986, p = 0.005) and TG (Beta = 0.366, t = 2.561, p = 0.015) were independent contributors to HAMD-17 in PD patients aged 50-59. Furthermore, non-depressive PD patients demonstrated better performance with respect to visuospatial/executive function among the 70-80 years group. These findings suggest that sex and age are crucial non-specific factors to consider when assessing the relationship between glycolipid metabolism, PD-specific factors and depression.


Assuntos
Envelhecimento , Glicemia , Depressão , Metabolismo dos Lipídeos , Doença de Parkinson , Caracteres Sexuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Envelhecimento/sangue , Envelhecimento/metabolismo , Glicemia/metabolismo , Depressão/sangue , Depressão/diagnóstico , Depressão/epidemiologia , Depressão/psicologia , Glicolipídeos/sangue , Glicolipídeos/metabolismo , Doença de Parkinson/sangue , Doença de Parkinson/epidemiologia , Doença de Parkinson/metabolismo , Doença de Parkinson/psicologia , Prevalência , Fatores de Risco , Disfunção Cognitiva/sangue , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/metabolismo , Estudos Transversais , Idoso , Idoso de 80 Anos ou mais , Distribuição por Idade , Cognição , Triglicerídeos/sangue , LDL-Colesterol/sangue
19.
Opt Express ; 31(12): 19453-19462, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37381360

RESUMO

To accurately measure the local temperatures of the micro-nano area, we propose an optical method using a tapered fiber Bragg grating (FBG) probe with a nano tip for scanning probe microscopy (SPM). When the tapered FBG probe senses local temperature through near-field heat transfer, the intensity of the reflected spectrum decreases, along with a broadening bandwidth and a shift in the central peak position. Modeling the heat transfer between the probe and the sample shows that the tapered FBG probe is in a non-uniform temperature field when approaching the sample surface. Simulation of the probe's reflection spectrum reveals that the central peak position shifts nonlinearly with increasing local temperature. In addition, the near-field temperature calibration experiments show that the temperature sensitivity of the FBG probe increases nonlinearly from 6.2 pm/°C to 9.4 pm/°C as the sample surface temperature increases from 25.3°C to 160.4°C. The agreement of the experimental results with the theory and the reproducibility demonstrate that this method offers a promising approach for exploring micro-nano temperature.

20.
Appl Opt ; 62(13): 3275-3283, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37132827

RESUMO

In order to efficiently select the optimal cutting position of x-ray mono-capillary lenses, an improved sine cosine algorithm-crow search algorithm (SCA-CSA) algorithm is proposed, which combines the sine cosine algorithm with the crow search algorithm, with further enhancements. The fabricated capillary profile is measured using an optical profiler; then the surface figure error for interest regions of the mono-capillary can be evaluated using the improved SCA-CSA algorithm. The experimental results indicate that the surface figure error in the final capillary cut region is about 0.138 µm, and the runtime is 2.284 s. When compared with the traditional metaheuristic algorithm, the particle swarm optimization algorithm, the improved SCA-CSA algorithm, enhances the surface figure error metric by two orders of magnitude. Furthermore, the standard deviation index of the surface figure error metric for 30 runs also improves by more than 10 orders of magnitude, demonstrating the superior performance and robustness of the algorithm. The proposed method provides significant support for the development of precise cuttings of mono-capillaries.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...