Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 23(12)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35742849

RESUMO

In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers using the electropolymerization technique in the development of a cadmium(II)-selective electrochemical sensor based on screen-printed gold electrode along with cyclic voltammetric measurement. At this point, we first screen for the primary plasticizer yielding the highest signal using cyclic voltammetry followed by pairing it with the secondary plasticizers giving rise to the most sensitive current response. The results show that the hybridization of DOS and TOTM with 3:1 weight ratio (~137.7-µm-thick membrane) renders a signal that is >26% higher than that from the sensor plasticized by DOS per se in water. The solution of 0.1 mM hydrochloric acid (pH 4) is the optimal supporting electrolyte. In addition, hybrid plasticizers have adequate redox capacity to induce cadmium(II) transfer from bulk solution to the membrane/water interfaces. Conversion of voltammetric signals to semi-integral currents results in linearity with cadmium(II) concentration, indicating the irreversible cadmium(II) transfer to the membrane. The DOS:TOTM hybrid sensor also exhibits high sensitivity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 95 ppb and 288 ppb, respectively, as well as greater specificity towards cadmium(II) than that obtained from the single plasticizer sensor. Furthermore, recovery rates of spiked cadmium(II) in water samples were higher than 97% using the hybrid plasticizer sensor. Unprecedentedly, our work reports that the hybridization of plasticizers serves as ion-to-electron transducer that can improve the sensor performance in cadmium(II) detection.


Assuntos
Cádmio , Plastificantes , Cádmio/química , Eletrodos , Ouro , Água
2.
Microbiol Resour Announc ; 8(46)2019 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-31727700

RESUMO

Haloferax volcanii SS0101 is a halophilic archaeon isolated from salt farms in Thailand. The genome sequence of H. volcanii SS0101 contains a gene encoding capreomycidine synthase, a key enzyme for capreomycidine biosynthesis. This 3.8-Mb draft genome sequence of H. volcanii SS0101 will provide the tools for investigating genes involved in capeomycidine production in haloarchaea.

3.
Artigo em Inglês | MEDLINE | ID: mdl-30714043

RESUMO

Bacillus salarius IM0101 is a halophilic bacterium that was isolated from soil in Inner Mongolia, China. The genome sequence of B. salarius IM0101 contains a biomarker gene for polyhydroxyalkanoate (PHA) synthesis. This 6.9-Mb draft genome sequence of B. salarius IM0101 will provide new insights into the organism's PHA production machinery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA