Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 16976, 2019 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-31740683

RESUMO

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from the qubit is amplified before noise sources are introduced and room-temperature amplifiers can operate at lower gain and higher BW. We compare the performance of two cryogenic amplification circuits: a current-biased heterojunction bipolar transistor circuit (CB-HBT), and an AC-coupled HBT circuit (AC-HBT). Both circuits are mounted on the mixing-chamber stage of a dilution refrigerator and are connected to silicon metal oxide semiconductor (Si-MOS) quantum dot devices on a printed circuit board (PCB). The power dissipated by the CB-HBT ranges from 0.1 to 1 µW whereas the power of the AC-HBT ranges from 1 to 20 µW. Referred to the input, the noise spectral density is low for both circuits, in the 15 to 30 fA/[Formula: see text] range. The charge sensitivity for the CB-HBT and AC-HBT is 330 µe/[Formula: see text] and 400 µe/[Formula: see text], respectively. For the single-shot readout performed, less than 10 µs is required for both circuits to achieve bit error rates below 10-3, which is a putative threshold for quantum error correction.

2.
Nature ; 555(7698): 633-637, 2018 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-29443962

RESUMO

Now that it is possible to achieve measurement and control fidelities for individual quantum bits (qubits) above the threshold for fault tolerance, attention is moving towards the difficult task of scaling up the number of physical qubits to the large numbers that are needed for fault-tolerant quantum computing. In this context, quantum-dot-based spin qubits could have substantial advantages over other types of qubit owing to their potential for all-electrical operation and ability to be integrated at high density onto an industrial platform. Initialization, readout and single- and two-qubit gates have been demonstrated in various quantum-dot-based qubit representations. However, as seen with small-scale demonstrations of quantum computers using other types of qubit, combining these elements leads to challenges related to qubit crosstalk, state leakage, calibration and control hardware. Here we overcome these challenges by using carefully designed control techniques to demonstrate a programmable two-qubit quantum processor in a silicon device that can perform the Deutsch-Josza algorithm and the Grover search algorithm-canonical examples of quantum algorithms that outperform their classical analogues. We characterize the entanglement in our processor by using quantum-state tomography of Bell states, measuring state fidelities of 85-89 per cent and concurrences of 73-82 per cent. These results pave the way for larger-scale quantum computers that use spins confined to quantum dots.

3.
Phys Rev Lett ; 115(10): 106802, 2015 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-26382693

RESUMO

We demonstrate coherent driving of a single electron spin using second-harmonic excitation in a Si/SiGe quantum dot. Our estimates suggest that the anharmonic dot confining potential combined with a gradient in the transverse magnetic field dominates the second-harmonic response. As expected, the Rabi frequency depends quadratically on the driving amplitude, and the periodicity with respect to the phase of the drive is twice that of the fundamental harmonic. The maximum Rabi frequency observed for the second harmonic is just a factor of 2 lower than that achieved for the first harmonic when driving at the same power. Combined with the lower demands on microwave circuitry when operating at half the qubit frequency, these observations indicate that second-harmonic driving can be a useful technique for future quantum computation architectures.

4.
Nat Nanotechnol ; 10(3): 243-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25686478

RESUMO

An intuitive realization of a qubit is an electron charge at two well-defined positions of a double quantum dot. This qubit is simple and has the potential for high-speed operation because of its strong coupling to electric fields. However, charge noise also couples strongly to this qubit, resulting in rapid dephasing at all but one special operating point called the 'sweet spot'. In previous studies d.c. voltage pulses have been used to manipulate semiconductor charge qubits but did not achieve high-fidelity control, because d.c. gating requires excursions away from the sweet spot. Here, by using resonant a.c. microwave driving we achieve fast (greater than gigahertz) and universal single qubit rotations of a semiconductor charge qubit. The Z-axis rotations of the qubit are well protected at the sweet spot, and we demonstrate the same protection for rotations about arbitrary axes in the X-Y plane of the qubit Bloch sphere. We characterize the qubit operation using two tomographic approaches: standard process tomography and gate set tomography. Both methods consistently yield process fidelities greater than 86% with respect to a universal set of unitary single-qubit operations.

5.
Proc Natl Acad Sci U S A ; 111(33): 11938-42, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25092298

RESUMO

The qubit is the fundamental building block of a quantum computer. We fabricate a qubit in a silicon double-quantum dot with an integrated micromagnet in which the qubit basis states are the singlet state and the spin-zero triplet state of two electrons. Because of the micromagnet, the magnetic field difference ΔB between the two sides of the double dot is large enough to enable the achievement of coherent rotation of the qubit's Bloch vector around two different axes of the Bloch sphere. By measuring the decay of the quantum oscillations, the inhomogeneous spin coherence time T2* is determined. By measuring T2* at many different values of the exchange coupling J and at two different values of ΔB, we provide evidence that the micromagnet does not limit decoherence, with the dominant limits on T2* arising from charge noise and from coupling to nuclear spins.

6.
Nat Nanotechnol ; 9(9): 666-70, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25108810

RESUMO

Nanofabricated quantum bits permit large-scale integration but usually suffer from short coherence times due to interactions with their solid-state environment. The outstanding challenge is to engineer the environment so that it minimally affects the qubit, but still allows qubit control and scalability. Here, we demonstrate a long-lived single-electron spin qubit in a Si/SiGe quantum dot with all-electrical two-axis control. The spin is driven by resonant microwave electric fields in a transverse magnetic field gradient from a local micromagnet, and the spin state is read out in the single-shot mode. Electron spin resonance occurs at two closely spaced frequencies, which we attribute to two valley states. Thanks to the weak hyperfine coupling in silicon, a Ramsey decay timescale of 1 µs is observed, almost two orders of magnitude longer than the intrinsic timescales in GaAs quantum dots, whereas gate operation times are comparable to those reported in GaAs. The spin echo decay time is ~40 µs, both with one and four echo pulses, possibly limited by intervalley scattering. These advances strongly improve the prospects for quantum information processing based on quantum dots.

7.
Nature ; 511(7507): 70-4, 2014 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-24990747

RESUMO

The similarities between gated quantum dots and the transistors in modern microelectronics--in fabrication methods, physical structure and voltage scales for manipulation--have led to great interest in the development of quantum bits (qubits) in semiconductor quantum dots. Although quantum dot spin qubits have demonstrated long coherence times, their manipulation is often slower than desired for important future applications, such as factoring. Furthermore, scalability and manufacturability are enhanced when qubits are as simple as possible. Previous work has increased the speed of spin qubit rotations by making use of integrated micromagnets, dynamic pumping of nuclear spins or the addition of a third quantum dot. Here we demonstrate a qubit that is a hybrid of spin and charge. It is simple, requiring neither nuclear-state preparation nor micromagnets. Unlike previous double-dot qubits, the hybrid qubit enables fast rotations about two axes of the Bloch sphere. We demonstrate full control on the Bloch sphere with π-rotation times of less than 100 picoseconds in two orthogonal directions, which is more than an order of magnitude faster than any other double-dot qubit. The speed arises from the qubit's charge-like characteristics, and its spin-like features result in resistance to decoherence over a wide range of gate voltages. We achieve full process tomography in our electrically controlled semiconductor quantum dot qubit, extracting high fidelities of 85 per cent for X rotations (transitions between qubit states) and 94 per cent for Z rotations (phase accumulation between qubit states).

8.
J Phys Condens Matter ; 20(37): 374118, 2008 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-21694425

RESUMO

Electromigrated nanoscale junctions have proven very useful for studying electronic transport at the single-molecule scale. However, confirming that conduction is through precisely the molecule of interest and not some contaminant or metal nanoparticle has remained a persistent challenge, typically requiring a statistical analysis of many devices. We review how transport mechanisms in both electronic and optical measurements can be used to infer information about the nanoscale junction configuration. The electronic response to optical excitation is particularly revealing. We briefly discuss surface-enhanced Raman spectroscopy on such junctions, and present new results showing that currents due to optical rectification can provide a means of estimating the local electric field at the junction due to illumination.

9.
Theriogenology ; 63(5): 1454-68, 2005 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15725451

RESUMO

Three experiments evaluated the effects of estradiol valerate (EV) on ovarian follicular and CL dynamics, intervals to estrus and ovulation, and superovulatory response in cattle. Experiment 1 compared the efficacy of two norgestomet ear implants (Crestar and Syncro-Mate B; SMB) for 9 d (with PGF at implant removal), combined with either 5 mg estradiol-17beta and 100 mg progesterone (EP) or 5 mg EV and 3mg norgestomet (EN) im at the time of implant insertion on CL diameter and follicular wave dynamics. Ovaries were monitored by ultrasonography. There was no effect of norgestomet implant. Diameter of the CL decreased following EN treatment (P < 0.01). Mean (+/- S.D.) day of follicular wave emergence (FWE) was earlier (P < 0.0001) and less variable (P < 0.0001) in EP- (3.6 +/- 0.5 d) than in EN- (5.7 +/- 1.5 d) treated heifers. Intervals from implant removal to estrus (P < 0.001) and ovulation (P < 0.01) were shorter in EN- (45.7 +/- 11.7 and 74.3 +/- 12.6 h, respectively) than in EP- (56.4 +/- 14.1 and 83.3 +/- 17.0 h, respectively) treated heifers. Experiment 2 compared the efficacy of EP versus EN in synchronizing FWE for superovulation in SMB-implanted cows. At random stages of the estrous cycle, Holstein cows (n = 78) received two SMB implants (Day 0) and were randomly assigned to receive EN on Day 0 or EP on Day 1. Folltropin-V treatments were initiated on the evening of Day 5, with PGF in the morning and evening of Day 8, when SMB were removed. Cows were inseminated after the onset of estrus and embryos were recovered 7 d later. Non-lactating cows had more CL (16.7 +/- 11.3 versus 8.3 +/- 4.9) and total ova/embryos (14.7 +/- 9.5 versus 7.9 +/- 4.6) than lactating cows (P < 0.05). EP-treated cows tended (P = 0.09) to yield more transferable embryos (5.6 +/- 5.2) than EN-treated cows (4.0 +/- 3.7). Experiment 3 compared the effect of dose of EV on ovarian follicle and CL growth profiles and synchrony of estrus and ovulation in CIDR-treated beef cows (n = 43). At random stages of the estrous cycle (Day 0), cows received a CIDR and no further treatment (Control), or an injection of 1, 2, or 5 mg im of EV. On Day 7, CIDR were removed and cows received PGF. Follicular wave emergence occurred within 7 d in 7/10 Control cows and 31/32 EV-treated cows (P < 0.05). In responding cows, interval from treatment to FWE was longer (P < 0.05) in those treated with 5 mg EV (4.8 +/- 1.2 d) than in those treated with 1 mg (3.2 +/- 0.9 d) or 2 mg (3.4 +/- 0.8 d) EV, while Control cows were intermediate (3.8 +/- 2.0 d). Diameter of the dominant follicle was smaller (P < 0.05) at CIDR removal and tended (P = 0.08) to be smaller just prior to ovulation in the 5 mg EV group (8.5 +/- 2.2 and 13.2 +/- 0.6 mm, respectively) than in the Control (11.8 +/- 4.6 and 15.5 +/- 2.9 mm, respectively) or 1mg EV (11.7 +/- 2.5 and 15.1 +/- 2.2 mm, respectively) groups, with the 2mg EV group (10.7 +/- 1.5 and 14.3 +/- 1.7 mm, respectively) intermediate. Diameter of the dominant follicle at CIDR removal was less variable (P < 0.01) in the 2 and 5mg EV groups than in the Control group, and intermediate in the 1mg EV group. In summary, treatment with 5mg EV resulted in a longer and more variable interval to follicular wave emergence than treatment with 5mg estradiol-17beta, which affected preovulatory dominant follicle size following progestin removal, and may have also affected superstimulatory response in Holstein cows. Additionally, 5 mg EV appeared to induce luteolysis in heifers, reducing the interval to ovulation following norgestomet removal. Conversely, intervals to, and synchrony of, follicular wave emergence, estrus and ovulation following treatment with 1 or 2 mg EV suggested that reduced doses of EV may be more useful for the synchronization of follicular wave emergence in progestogen-treated cattle.


Assuntos
Bovinos/fisiologia , Estradiol/análogos & derivados , Estradiol/farmacologia , Folículo Ovariano/efeitos dos fármacos , Folículo Ovariano/fisiologia , Progestinas/administração & dosagem , Superovulação/efeitos dos fármacos , Animais , Corpo Lúteo/anatomia & histologia , Corpo Lúteo/fisiologia , Implantes de Medicamento , Estradiol/administração & dosagem , Ciclo Estral , Sincronização do Estro , Feminino , Lactação , Pregnenodionas/administração & dosagem , Progesterona/administração & dosagem , Fatores de Tempo
10.
Biomed Sci Instrum ; 32: 293-8, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8672682

RESUMO

BreathSim is a new computer simulation of the anesthesia breathing circuit, ventilator, and respiratory system. The system permits user-control over various respiratory parameters, ventilator functions, and the integrity and performance of the anesthesia machine and breathing circuit. Respiratory gas pressure, flow, and carbon dioxide (CO2) concentration data may be simultaneously displayed from several locations in the system. Pressure-volume and flow-volume tracings (spirometry) are displayed as well. In addition, an animation which is synchronized to the simulation displays the movement of oxygen and CO2 in the system. We propose the use of the simulator to test and evaluate the software algorithms utilized in respiratory gas monitoring equipment and anesthesia workstations. The output of the simulator can provide a "patient signal" input to the monitor and specific algorithms (e.g. breath detection, waveform recognition) could be evaluated. Rare but significant clinical states may be easily simulated, and the simulator may be driven by "scripts" to permit reproducibility.


Assuntos
Anestesia Geral , Simulação por Computador , Respiração , Dióxido de Carbono/análise , Humanos , Modelos Biológicos , Modelos Teóricos , Monitorização Fisiológica
11.
Surgery ; 91(1): 24-7, 1982 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7054902

RESUMO

A case of fatal pulmonary hemorrhage secondary to catheterization with a balloon-tipped catheter is described, and the literature describing possible mechanisms for this complication is reviewed. A common denominator in patients suffering pulmonary hemorrhage is pulmonary hypertension. Recommendations for management of this complication are discussed.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Hemotórax/etiologia , Feminino , Hemotórax/mortalidade , Humanos , Pessoa de Meia-Idade , Artéria Pulmonar/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...