Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Chimia (Aarau) ; 73(1): 59, 2019 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-30814000

RESUMO

Pore-forming peptides are of interest due to their antimicrobial activity and ability to form gateways through lipid membranes. Chemical modification of these peptides makes it possible to arrange several peptide monomers into well-defined pore-forming structures using various templating strategies. These templated super-structures can exert antimicrobial activity at significantly lower total peptide concentration than their untemplated equivalents. In addition, the chemical moieties used for templating may be functionalized to interact specifically with targeted membranes such as those of pathogens or cancer cells. A range of molecular templates has been explored, including dimerization of pore-forming monomers, their covalent attachment to cyclodextrin, porphyrin or fullerene scaffolds as well as attachment of amino acid linkers or nucleic acid constructs to generate assemblies of 4 to 26 peptides or proteins. Compared to free peptide monomers, templated pore assemblies showed increased membrane affinity, prolonged open-state lifetimes of the pores and more frequent pore formation due to higher local concentration. These constructs are useful model systems for biophysical studies to understand porin and ion channel proteins and their mechanisms of insertion into lipid membranes. Recently designed DNA-templates are expanding the usefulness of templated pore assemblies beyond applications of cell killing and may include targeted drug delivery and accelerate the emerging field of single-molecule detection and characterization of biomolecules by nanopore-based resistive pulse sensing.


Assuntos
Lipídeos , Peptídeos , Biofísica , Membrana Celular , Bicamadas Lipídicas , Nanotecnologia
3.
Sci Rep ; 8(1): 2454, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29410460

RESUMO

The development of new materials with reduced noise and vibration levels is an active area of research due to concerns in various aspects of environmental noise pollution and its effects on health. Excessive vibrations also reduce the service live of the structures and limit the fields of their utilization. In oscillations, the viscoelastic moduli of a material are complex and it is their loss part - the product of the stiffness part and loss tangent - that is commonly viewed as a figure of merit in noise and vibration damping applications. The stiffness modulus and loss tangent are usually mutually exclusive properties so it is a technological challenge to develop materials that simultaneously combine high stiffness and high loss. Here we achieve this rare balance of properties by filling a solid polymer matrix with rigid inorganic spheres coated by a sub-micron layer of a viscoelastic material with a high level of internal friction. We demonstrate that this combination can be experimentally realised and that the analytically predicted behaviour is closely reproduced, thereby escaping the often termed 'Ashby' limit for mechanical stiffness/damping trade-off and offering a new route for manufacturing advanced composite structures with markedly reduced noise and vibration levels.

4.
J Mech Behav Biomed Mater ; 37: 12-23, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24878964

RESUMO

A multi-element constitutive model for a lactide-based shape memory polymer has been developed that represents loading to large tensile deformations, stress relaxation and stress recovery at 60, 65 and 70°C. The model consists of parallel Maxwell arms each comprising neo-Hookean and Eyring elements. Guiu-Pratt analysis of the stress relaxation curves yields Eyring parameters. When these parameters are used to define the Eyring process in a single Maxwell arm, the resulting model yields at too low a stress, but gives good predictions for longer times. Stress dip tests show a very stiff response on unloading by a small strain decrement. This would create an unrealistically high stress on loading to large strain if it were modelled by an elastic element. Instead it is modelled by an Eyring process operating via a flow rule that introduces strain hardening after yield. When this process is incorporated into a second parallel Maxwell arm, there results a model that fully represents both stress relaxation and stress dip tests at 60°C. At higher temperatures a third arm is required for valid predictions.


Assuntos
Elasticidade , Teste de Materiais , Modelos Teóricos , Poliglactina 910 , Estresse Mecânico , Suporte de Carga , Temperatura , Resistência à Tração
5.
J Chem Phys ; 139(21): 214501, 2013 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-24320385

RESUMO

Longitudinal relaxation (T1) measurements of (19)F, (7)Li, and (1)H in propylene carbonate/LiBF4 liquid electrolytes are reported. Comparison of T1 values with those for the transverse relaxation time (T2) confirm that the measurements are in the high temperature (low correlation time) limit of the T1 minimum. Using data from pulsed field gradient measurements of self-diffusion coefficients and measurements of solution viscosity measured elsewhere, it is concluded that although in general there are contributions to T1 from both translational and rotational motions. For the lithium ions, this is mainly translational, and for the fluorine ions mainly rotational.

6.
J Mater Sci Mater Med ; 15(12): 1339-47, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15747187

RESUMO

The wear and mechanical properties of GUR 1020 (Perplas IMP 2000-2) Ultra High Molecular Weight Polyethylene (UHMWPE) subjected to gamma-irradiation in an atmosphere of acetylene, were evaluated for a range of processing conditions of irradiation, annealing and ageing. The results were compared with those obtained for the virgin UHMWPE material and material processed using conventional gamma-irradiation in nitrogen. Cross-linking produced by irradiation in acetylene, followed by subsequent annealing was found to be significantly more effective in improving the mechanical and wear properties of UHMWPE compared to when the material was irradiated in nitrogen. Gel fraction analysis on its own, while being able to detect the degree of cross-linking, was found to be insufficient in determining the effectiveness of the cross-links and the resulting mechanical properties of the UHMWPE material. The results suggest that gamma-irradiation in an atmosphere of acetylene may provide significant advantages over conventional UHMWPE processing and irradiation cross-linking techniques.


Assuntos
Acetileno/química , Raios gama , Polietilenos/química , Teste de Materiais , Polietilenos/efeitos da radiação
7.
J Biol Chem ; 276(51): 47759-62, 2001 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-11673449

RESUMO

H2AX, a member of the histone H2A family, is rapidly phosphorylated in response to ionizing radiation. This phosphorylation, at an evolutionary conserved C-terminal phosphatidylinositol 3-OH-kinase-related kinase (PI3KK) motif, is thought to be critical for recognition and repair of DNA double strand breaks. Here we report that inhibition of DNA replication by hydroxyurea or ultraviolet irradiation also induces phosphorylation and foci formation of H2AX. These phospho-H2AX foci colocalize with proliferating cell nuclear antigen (PCNA), BRCA1, and 53BP1 at the arrested replication fork in S phase cells. This response is ATR-dependent but does not require ATM or Hus1. Our findings suggest that, in addition to its role in the recognition and repair of double strand breaks, H2AX also participates in the surveillance of DNA replication.


Assuntos
Proteínas de Ciclo Celular/metabolismo , Replicação do DNA , Histonas/metabolismo , Proteínas Serina-Treonina Quinases , Proteínas Mutadas de Ataxia Telangiectasia , Linhagem Celular , Replicação do DNA/efeitos dos fármacos , Replicação do DNA/efeitos da radiação , Humanos , Hidroxiureia/farmacologia , Fosforilação , Raios Ultravioleta
8.
J Biol Chem ; 276(51): 47755-8, 2001 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-11668173

RESUMO

The protein kinase Chk2 has been implicated in signaling DNA damage to cell cycle checkpoints. In response to ionizing radiation, Chk2 becomes rapidly phosphorylated at threonine 68 by ataxia-telangiectasia mutated (ATM). Here we show that the Thr(68)-phosphorylated form of Chk2 forms distinct nuclear foci in response to ionizing radiation. Only this activated form of Chk2 localizes at sites of DNA strand breaks. The kinase activity of Chk2 and the number of Chk2 foci formed depend on the severity of DNA damage and gradually decline correlating with the predicted value of slowly re-joining double strand breaks. These results suggest that Chk2 is regulated at the sites of DNA strand breaks in response to ionizing radiation.


Assuntos
Dano ao DNA , DNA/efeitos da radiação , Proteínas Quinases/metabolismo , Proteínas Serina-Treonina Quinases , Treonina/metabolismo , Sequência de Aminoácidos , Núcleo Celular/enzimologia , Núcleo Celular/efeitos da radiação , Quinase do Ponto de Checagem 2 , DNA/química , Ativação Enzimática , Raios gama , Cinética , Fosforilação , Proteínas Quinases/química
9.
J Mater Sci Mater Med ; 12(7): 621-8, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15348255

RESUMO

This paper investigates the benefits of combining roll-drawing and acetylene-enhanced crosslinking to alter the mechanical properties of the ultra high molecular weight polyethylene (UHMWPE) used in total hip and knee replacements, with the aim of improving its resistance to wear. UHMWPE was processed via crosslinking, roll-drawing and a combination of crosslinking and roll-drawing and subjected to gel content analysis, tensile tests, X-ray diffraction and wear tests using different types of motion and smooth and rough counterfaces. Purely roll-drawn materials with length and width draw ratios of lambda l x lambda w = 1.3 x 1.0 and lambda1 x lambdaw = 1.6 x 0.9 respectively, were found to have lower wear factors in a unidirectional motion test with a rough counterface when compared to the virgin material. The crosslinked roll-drawn material, with length and width draw ratios of lambda1 x lambdaw = 1.6 x 0.9, was seen to possess five crosslinks per initial number average molecule. This crosslinked and roll-drawn material showed 5.5 times less wear than the virgin material in a multidirectional motion test with a smooth counterface and 1.4 times more wear than the virgin material in a unidirectional motion test with a rough counterface. Hence this study supports previous work by the authors that acetylene-enhanced crosslinked materials may show benefits for a total hip replacement, but only where the femoral head remains smooth. The improvements in wear with the roll-drawn material in unidirectional tests were smaller, but may prove to have some benefits in the knee.

10.
J Mater Sci Mater Med ; 10(6): 333-42, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15348134

RESUMO

In this study, the wear of ultra high molecular weight polyethylene (UHMWPE) (Grade RCH 1000) crosslinked by gamma irradiation in acetylene was compared to virgin (non-irradiated) UHMWPE using four different wear configurations: (i) unidirectional motion with a smooth counterface, (ii) multidirectional motion with a smooth counterface, (iii) unidirectional motion with a rough counterface and (iv) multidirectional motion with a rough counterface.

11.
Dent Mater ; 9(2): 128-35, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8595842

RESUMO

A newly developed incremental mixing technique has been used to incorporate over 30 vol % chopped high performance polyethylene fiber into acrylic denture base resin. The reinforcement produced a substantial improvement in several clinically important properties, namely: 1) stiffness and impact strength were higher; 2) the mechanical properties were insensitive to notches that mimic anatomical features; and 3) samples damaged during bending and impact did not break up into separate fragments. Reinforced complete maxillary and mandibular dentures of good esthetic appearance were successfully manufactured and polished with conventional laboratory techniques.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Planejamento de Dentadura/métodos , Polietilenos/química , Prótese Total , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Tecnologia Odontológica/métodos , Água
12.
Aust Dent J ; 38(1): 28-38, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8447769

RESUMO

Previous work has established the feasibility of producing acrylic denture bases reinforced with layers of highly drawn linear polyethylene fibres in a woven form. This paper reports on the mechanical properties of the system, including the effect of water conditioning. It is confirmed that substantial improvements in impact strength can be obtained by the incorporation of the polyethylene fibres in woven form. The fibre/resin integration within the dentures has also been studied by optical microscopy. It was found that delamination may occur during some processing stages and steps are suggested to avoid this problem.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Planejamento de Dentadura , Polietilenos/química , Fenômenos Químicos , Físico-Química , Elasticidade , Teste de Materiais , Metilmetacrilatos/química , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Água
13.
Biomaterials ; 13(1): 17-9, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1531935

RESUMO

A study has been made of the reinforcement of 2,2 bis-4(2 hydroxy-3-methacryloyloxy propoxy) phenyl propane/tetra-hydrofurfuryl methacrylate copolymers with ultra-high modulus polyethylene fibres. The fibres were orientated longitudinally, in loadings up to 50% w/w, and both untreated and surface treated fibres were studied. Modulii up to approximately 35 GPa were achieved in the axial direction, and the specimens could not be broken in the simple flexure test employed. Electron microscopy of fractured specimens showed extremely good contact between resin and fibre. No deterioration in properties was observed over 6 months in water.


Assuntos
Materiais Biocompatíveis , Polímeros , Bis-Fenol A-Glicidil Metacrilato , Teste de Materiais , Metacrilatos , Microscopia Eletrônica , Polietilenos
14.
Biomaterials ; 12(1): 13-6, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2009338

RESUMO

The shear modulus and elastic limit in shear were determined for a number of polymers of clinical interest, using a static torsion method. In particular, ultra-high modulus polyethylene was studied as a function of draw ratio, and compared with corresponding Young's modulus data. Materials of high shear moduli of potential clinical value are described.


Assuntos
Materiais Biocompatíveis , Materiais Dentários , Teste de Materiais , Polietilenos , Elasticidade
15.
Clin Mater ; 6(3): 209-25, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-10147520

RESUMO

This paper reports on the effect of reinforcing dental resins with continuous, longitudinally oriented highly drawn linear polyethylene fibres. The mechanical properties were measured in 3-point bending, and the composites showed a very substantial improvement when compared with the properties of an unreinforced resin. The performance improves as the fibre content increases, and the type of resin does not appear to be a significant factor. It is shown that the inclusion of the reinforcement changes the mode of failure of the resin from brittle to ductile; that is, the system may be damaged but it does not disintegrate.


Assuntos
Resinas Compostas/química , Bases de Dentadura , Prótese Adesiva , Metilmetacrilatos/química , Polietilenos/química , Planejamento de Dentadura , Humanos , Teste de Materiais , Estresse Mecânico , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA