Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Neth Heart J ; 29(5): 288-294, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33201485

RESUMO

BACKGROUND: The relative new subspecialty 'cardio-oncology' was established to meet the growing demand for an interdisciplinary approach to the management of cancer therapy-related cardiovascular adverse events. In recent years, specialised cardio-oncology services have been implemented worldwide, which all strive to improve the cardiovascular health of cancer patients. However, limited data are currently available on the outcomes and experiences of these specialised services, and optimal strategies for cardio-oncological care have not been established. AIM: The ONCOR registry has been created for prospective data collection and evaluation of cardio-oncological care in daily practice. METHODS: Dutch hospitals using a standardised cardio-oncology care pathway are included in this national, multicentre, observational cohort study. All patients visiting these cardio-oncology services are eligible for study inclusion. Data collection at baseline consists of the (planned) cancer treatment and the cardiovascular risk profile, which are used to estimate the cardiotoxic risk. Information regarding invasive and noninvasive tests is collected during the time patients receive cardio-oncological care. Outcome data consist of the incidence of cardiovascular complications and major adverse cardiac events, and the impact of these events on the oncological treatment. DISCUSSION: Outcomes of the ONCOR registry may aid in gaining more insight into the incidence of cancer therapy-related cardiovascular complications. The registry facilitates research on mechanisms of cardiovascular complications and on diagnostic, prognostic and therapeutic strategies. In addition, it provides a platform for future (interventional) studies. Centres with cardio-oncology services that are interested in contributing to the ONCOR registry are hereby invited to participate.

2.
Neth J Med ; 74(1): 5-15, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26819356

RESUMO

BACKGROUND: Percutaneous renal denervation (RDN) has recently been introduced as a treatment for therapy-resistant hypertension. Also, it has been suggested that RDN may be beneficial for other conditions characterised by increased sympathetic nerve activity. There are still many uncertainties with regard to efficacy, safety, predictors for success and long-term effects. To answer these important questions, we initiated a Dutch RDN registry aiming to collect data from all RDN procedures performed in the Netherlands. METHODS: The Dutch RDN registry is an ongoing investigator-initiated, prospective, multicentre cohort study. Twenty-six Dutch hospitals agreed to participate in this registry. All patients who undergo RDN, regardless of the clinical indication or device that is used, will be included. Data are currently being collected on eligibility and screening, treatment and follow-up. RESULTS: Procedures have been performed since August 2010. At present, data from 306 patients have been entered into the database. The main indication for RDN was hypertension (n = 302, 99%). Patients had a mean office blood pressure of 177/100 (±29/16) mmHg with a median use of three (range 0-8) blood pressure lowering drugs. Mean 24-hour blood pressure before RDN was 157/93 (±18/13) mmHg. RDN was performed with different devices, with the Simplicity™ catheter currently used most frequently. CONCLUSION: Here we report on the rationale and design of the Dutch RDN registry. Enrolment in this investigator-initiated study is ongoing. We present baseline characteristics of the first 306 participants.


Assuntos
Hipertensão/cirurgia , Sistema de Registros , Artéria Renal/cirurgia , Simpatectomia/estatística & dados numéricos , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Feminino , Humanos , Hipertensão/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Período Pré-Operatório , Estudos Prospectivos , Artéria Renal/inervação , Simpatectomia/métodos , Tempo , Resultado do Tratamento
3.
Int J Cardiol ; 168(3): 2153-8, 2013 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-23465250

RESUMO

BACKGROUND: The focus of the diagnostic process in chest pain patients at the emergency department is to identify both low and high risk patients for an acute coronary syndrome (ACS). The HEART score was designed to facilitate this process. This study is a prospective validation of the HEART score. METHODS: A total of 2440 unselected patients presented with chest pain at the cardiac emergency department of ten participating hospitals in The Netherlands. The HEART score was assessed as soon as the first lab results and ECG were obtained. Primary endpoint was the occurrence of major adverse cardiac events (MACE) within 6 weeks. Secondary endpoints were (i) the occurrence of AMI and death, (ii) ACS and (iii) the performance of a coronary angiogram. The performance of the HEART score was compared with the TIMI and GRACE scores. RESULTS: Low HEART scores (values 0-3) were calculated in 36.4% of the patients. MACE occurred in 1.7%. In patients with HEART scores 4-6, MACE was diagnosed in 16.6%. In patients with high HEART scores (values 7-10), MACE occurred in 50.1%. The c-statistic of the HEART score (0.83) is significantly higher than the c-statistic of TIMI (0.75)and GRACE (0.70) respectively (p<0.0001). CONCLUSION: The HEART score provides the clinician with a quick and reliable predictor of outcome, without computer-required calculating. Low HEART scores (0-3), exclude short-term MACE with >98% certainty. In these patients one might consider reserved policies. In patients with high HEART scores (7-10) the high risk of MACE may indicate more aggressive policies.


Assuntos
Dor no Peito/diagnóstico , Angiografia Coronária/métodos , Eletrocardiografia , Serviço Hospitalar de Emergência , Infarto do Miocárdio/diagnóstico , Medição de Risco/métodos , Idoso , Dor no Peito/epidemiologia , Dor no Peito/etiologia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Países Baixos/epidemiologia , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências
4.
Neth Heart J ; 20(6): 254-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22328356

RESUMO

BACKGROUND: We studied the characteristics of ST-elevation myocardial infarction (STEMI) patients from a local acute coronary syndrome (ACS) registry in order to find and build an appropriate acute myocardial infarction (AMI) system of care in Jakarta, Indonesia. METHODS: Data were collected from the Jakarta Acute Coronary Syndrome (JAC) registry 2008-2009, which contained 2103 ACS patients, including 654 acute STEMI patients admitted to the National Cardiovascular Center Harapan Kita, Jakarta, Indonesia. RESULTS: The proportion of patients who did not receive reperfusion therapy was 59% in all STEMI patients and the majority of them (52%) came from inter-hospital referral. The time from onset of infarction to hospital admission was more than 12 h in almost 80% cases and 60% had an anterior wall MI. In-hospital mortality was significantly higher in patients who did not receive reperfusion therapy compared with patients receiving acute reperfusion therapy, either with primary percutaneous coronary intervention (PPCI) or fibrinolytic therapy (13.3% vs 5.3% vs 6.2%, p < 0.001). CONCLUSION: The Jakarta Cardiovascular Care Unit Network System was built to improve the care of AMI in Jakarta. This network will harmonise the activities of all hospitals in Jakarta and will provide the best cardiovascular services to the community by giving two reperfusion therapy options (PPCI or pharmaco-invasive strategy) depending on the time needed for the patient to reach the cath-lab.

5.
Case Rep Cardiol ; 2011: 186921, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-24804109

RESUMO

Congenital anomalies of the coronary arteries are relatively rare. Mostly asymptomatic, however, some can cause problems, as heart failure, myocardial ischemia, and ventricular arrhythmia, and are associated with risk of complications, such as endocarditis and coronary rupture or sudden death. A case of a 69-year-old man with complaints of tiredness, dyspnea, and palpitation due to coronary artery fistula is presented with a review of the literature.

7.
8.
Neth Heart J ; 14(7-8): 265-266, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25696652
9.
Eur Heart J ; 23(13): 1038-44, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12093056

RESUMO

AIMS: Intracoronary radiation is a promising therapy potentially reducing restenosis following catheter-based interventions. Currently, only limited data on this treatment are available. The feasibility and outcome in daily routine practice, however, is unknown. METHODS AND RESULTS: In 100 consecutive patients, intracoronary beta-radiation was performed with a (90)Strontium system (Novoste Beta-Cathtrade mark) following angioplasty. Predominantly complex (73% type B2 and C) and long lesions (length 24.3+/-15.3 mm) were included (37% de novo, 19% restenotic and 44% in-stent restenotic lesions). Radiation success was 100%. Mean prescribed dose was 19.8+/-2.5 Gy. A pullback procedure was performed in 19% lesions. Geographic miss occurred in 8% lesions. Periprocedural thrombus formation occurred in four lesions, dissection in nine lesions. During hospital stay, no death, acute myocardial infarction, or repeat revascularization was observed. Major adverse cardiac events occurred predominantly between 6 and 12 months after the index procedure with major adverse cardiac event-free survival of 66% at 12 months (one death, 10 Q-wave myocardial infarctions, 23 target vessel revascularizations; ranked for worst event). CONCLUSION: Routine catheter-based intracoronary beta-radiation therapy after angioplasty is safe and feasible with a high acute procedural success. The clinical 1-year follow-up showed delayed occurrence of major adverse cardiac events between 6 and 12 months after the index procedure.


Assuntos
Braquiterapia/métodos , Reestenose Coronária/radioterapia , Idoso , Angioplastia Coronária com Balão , Partículas beta/uso terapêutico , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radioisótopos de Estrôncio/uso terapêutico
10.
Eur Heart J ; 23(8): 641-9, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11969279

RESUMO

AIMS: We sought to compare the effect of intracoronary beta-radiation on the vessel dimensions in de novo lesions using three-dimensional intravascular ultrasound quantification after balloon angioplasty and stenting. METHODS AND RESULTS: Forty patients (44 vessels; 28 balloon angioplasty and 16 stenting) treated with catheter-based beta-radiation and 18 non-irradiated control patients (18 vessels; 10 balloon angioplasty and 8 stenting) were investigated by means of three-dimensional volumetric intravascular ultrasound analysis post-procedure and at 6-8 months follow-up. Total vessel (EEM) volume enlarged after both balloon angioplasty and stenting (+37 mm(3) vs +42 mm(3), P=ns), but vessel wall volume (plaque plus media) also increased similarly (+33 mm(3) vs +49 mm(3), P=ns) in the irradiated patients. Lumen volume remained unchanged in both groups (+3 mm(3) vs -7 mm(3), P=ns). In the stent-covered segments, neointima at follow-up was significantly smaller in the irradiated group than the control group (8 mm(3) vs 27 mm(3), P=0.001, respectively), but the total amount of tissue growth was similar in both groups (33 mm(3) vs 29 mm(3), P=ns). CONCLUSIONS: Intracoronary beta-radiation induces vessel enlargement after balloon angioplasty and/or stenting, accommodating tissue growth. Additional stenting may not play an important role in the prevention of constrictive remodelling in the setting of catheter-based intracoronary beta-radiotherapy.


Assuntos
Angioplastia Coronária com Balão , Cateterismo Cardíaco , Vasos Coronários/cirurgia , Observação , Stents , Idoso , Partículas beta , Implante de Prótese Vascular , Reestenose Coronária/etiologia , Estenose Coronária/complicações , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos da radiação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
Circulation ; 105(5): 550-3, 2002 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-11827917

RESUMO

BACKGROUND: Radioactive stents with an activity of 0.75 to 12 microCi have shown >40% edge restenosis due to neointimal hyperplasia and negative remodeling. This trial evaluated whether radioactive Cold Ends stents might resolve edge restenosis by preventing remodeling at the injured extremities. METHODS AND RESULTS: The 25-mm long (15-mm radioactive center and 5-mm nonradioactive ends) Cold Ends stents had an activity of 3 to 12 microCi at implantation. Forty-three stents were implanted in 43 patients with de novo native coronary artery disease. Two procedural, 1 subacute, and 1 late stent thrombosis occurred. A restenosis rate of 22% was observed with a shift of the restenosis, usually occurring at the stent edges of radioactive stents, into the Cold Ends stents. The most severe restenosis occurred at the transition zone from radioactive to nonradioactive segments, a region located in dose fall-off. CONCLUSION: Cold Ends stents did not resolve edge restenosis.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Braquiterapia/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Oclusão de Enxerto Vascular/etiologia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/etiologia , Braquiterapia/métodos , Doença da Artéria Coronariana/tratamento farmacológico , Trombose Coronária/etiologia , Relação Dose-Resposta à Radiação , Feminino , Fibrinolíticos/uso terapêutico , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Fósforo/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Resultado do Tratamento
12.
Eur Heart J ; 22(15): 1311-7, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11465963

RESUMO

BACKGROUND: Edge restenosis is a major problem after radioactive stenting. The cold-end stent has a radioactive mid-segment (15.9 mm) and non-radioactive proximal and distal 5.7 mm segments. Conceptually this may negate the impact of negative vascular remodelling at the edge of the radiation. METHOD AND RESULTS: ECG-gated intravascular ultrasound with three-dimensional reconstruction was performed post-stent implantation and at the 6-month follow-up to assess restenosis within the margins of the stent and at the stent edges in 16 patients. Angiographic restenosis was witnessed in four patients, all in the proximal in-stent position. By intravascular ultrasound in-stent neointimal hyperplasia, with a >50% stented cross-sectional area, was seen in eight patients. This was witnessed proximally (n=2), distally (n=2) and in both segments (n=4). Echolucent tissue, dubbed the 'black hole' was seen as a significant component of neointimal hyperplasia in six out of the eight cases of restenosis. Neointimal hyperplasia was inhibited in the area of radiation: Delta neointimal hyperplasia=3.72 mm3 (8.6%); in-stent at the edges of radiation proximally and distally Delta neointimal hyperplasia was 7.9 mm3 (19.0%) and 11.4 mm3 (25.6%), respectively (P=0.017). At the stent edges there was no significant change in lumen volume. CONCLUSIONS: Cold-end stenting results in increased neointimal hyperplasia in in-stent non-radioactive segments.


Assuntos
Braquiterapia , Doença das Coronárias/terapia , Vasos Coronários/patologia , Stents , Túnica Íntima/patologia , Divisão Celular/efeitos da radiação , Doença das Coronárias/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos da radiação , Humanos , Hiperplasia/diagnóstico por imagem , Hiperplasia/prevenção & controle , Radioisótopos de Fósforo/uso terapêutico , Prevenção Secundária , Stents/efeitos adversos , Ultrassonografia de Intervenção
13.
Eur Heart J ; 22(8): 669-75, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11286524

RESUMO

AIMS: This study is the contribution by the Thoraxcenter, Rotterdam, to the European(32)P Dose Response Trial, a non-randomized multicentre trial to evaluate the safety and efficacy of the radioactive Isostent in patients with single coronary artery disease. METHODS AND RESULTS: The radioactivity of the stent at implantation was 6--12 microCi. All patients received aspirin indefinitely and either ticlopidine or clopidogrel for 3 months. Quantitative coronary angiography measurements of both the stent area and the target lesion (stent area and up to 5 mm proximal and distal to the stent edges) were performed pre- and post-procedure and at the 5-month follow-up. Forty-two radioactive stents were implanted in 40 patients. Treated vessels were the left anterior descending coronary artery (n=20), right coronary artery (n=10) or left circumflex artery (n=10). Eight patients received additional non-radioactive stents. Lesion length measured 10+/-3 mm with a reference diameter of 3.07+/-0.69 mm. Minimal lumen diameter increased from 0.98+/-0.53 mm pre-procedure to 2.29+/-0.52 mm (target lesion) and 2.57+/-0.44 mm (stent area) post-procedure. There was one procedural non-Q wave myocardial infarction, due to transient thrombotic closure. Thirty-six patients returned for angiographical follow-up. Two patients had a total occlusion proximal to the radioactive stent. Of the patent vessels, none had in-stent restenosis. Edge restenosis was observed in 44%, occurring predominantly at the proximal edge. Target lesion revascularization was performed in 10 patients and target vessel revascularization in one patient. No additional clinical end-points occurred during follow-up. The minimal lumen diameter at follow-up averaged 1.66+/-0.71 mm (target lesion) and 2.12+/-0.72 (stent area); therefore late loss was 0.63+/-0.69 (target lesion) and 0.46+/-0.76 (stent area), resulting in a late loss index of 0.65+/-1.15 (target lesion) and 0.30+/-0.53 (stent area). CONCLUSION: These results indicate that the use of radioactive stents is safe and feasible, however, the high incidence of edge restenosis makes this technique currently clinically non-applicable.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Braquiterapia/instrumentação , Braquiterapia/métodos , Infarto do Miocárdio/radioterapia , Radioisótopos de Fósforo/uso terapêutico , Stents , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Braquiterapia/efeitos adversos , Angiografia Coronária , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Radioisótopos de Fósforo/efeitos adversos , Doses de Radiação , Recidiva , Fatores de Risco , Segurança , Índice de Gravidade de Doença , Stents/efeitos adversos , Resultado do Tratamento
14.
Eur Heart J ; 22(7): 580-6, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11259145

RESUMO

AIM: Leukocytes have been implicated in restenosis following percutaneous transluminal coronary angioplasty. We investigated the link between the activated status of circulating neutrophils and restenosis after angioplasty. METHODS AND RESULTS: The population of 108 patients with single, de novo lesions located in native coronary arteries were treated with elective balloon angioplasty (n=44) or stenting (n=64). Pre-, post-procedure and 6-month follow-up, angiograms were analysed by an independent core laboratory. Blood samples were collected immediately before treatment and the antigen CD66, which is specifically expressed by activated neutrophils, was measured. Overall, the average expression of CD66 was 6.4+/-3.6 of mean fluorescence intensity. In the stepwise linear regression model, which included biological, clinical and angiographic variables, absolute gain showed a direct association (P<0.001) with relative late loss (relative late loss=absolute late loss/pre-procedure reference diameter), whereas CD66 expression was inversely associated with relative late loss (P=0.004). CD66 expression also showed an inverse association with relative late loss in the balloon angioplasty treated patients (P=0.002, beta=-0.49). In the stent subgroup, only reference vessel diameter and acute gain were independent predictors of relative late loss. CONCLUSION: Our results confirm the beneficial role of activated neutrophils pre-procedure in the restenotic process after balloon angioplasty. The lack of a relationship between CD66 expression by neutrophils and relative late loss after stenting suggests that this leukocyte may be involved in the remodelling process.


Assuntos
Angioplastia Coronária com Balão , Oclusão de Enxerto Vascular/fisiopatologia , Ativação de Neutrófilo/fisiologia , Antígenos CD/fisiologia , Antígenos de Diferenciação/fisiologia , Moléculas de Adesão Celular , Angiografia Coronária , Feminino , Citometria de Fluxo , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monócitos/fisiologia , Valor Preditivo dos Testes
15.
Circulation ; 103(1): 14-7, 2001 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-11136678

RESUMO

BACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS: Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS: Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting.


Assuntos
Braquiterapia , Doença das Coronárias/radioterapia , Oclusão de Enxerto Vascular/prevenção & controle , Radioisótopos de Fósforo/uso terapêutico , Stents , Adulto , Idoso , Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Angiografia Coronária , Doença das Coronárias/patologia , Doença das Coronárias/cirurgia , Endossonografia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Fósforo/efeitos adversos , Doses de Radiação , Falha de Tratamento , Resultado do Tratamento
16.
Int J Cardiovasc Imaging ; 17(5): 405-10, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12025954

RESUMO

The aim of this study was to explore the clinical possibilities of a new strategy for magnetic resonance imaging of the coronary arteries. Thirteen patients were studied by volume coronary angiography using targeted scans (VCATS) to visualize the major coronary arteries in a series of breath-holds. The proximal coronary arteries were clearly seen in 92% and the mid segments in 50-70% of the patients. VCATS was able to visualize a total vessel length of the left main (LM) (mean: 9.4+/-3.4 mm), of the left anterior descending (LAD) 69+/-20 mm, of the right coronary artery (RCA) 90+/-33 mm and of the left circumflex (LCX) 41+/-18 mm. There was a reasonable correlation between the VCATS and conventional coronary angiography (CAG) for vessel diameter (r = 0.71), with a slight overestimation of 0.7 mm by VCATS. There were nine significant stenoses present of which six were correctly detected, three were missed and one false positive was present. VCATS is fast strategy for visualizing the major coronary artery branches and has the potential to detect significant stenoses in these branches.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estatística como Assunto
17.
Am J Cardiol ; 86(9): 1047-50, A11, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11053728

RESUMO

In 40 patients, we compared linear local shortening assessed with nonfluoroscopic electromechanical mapping as a function of regional wall motion with echocardiographic data in a subset of patients with severe coronary artery disease and subsequently decreased left ventricular function. Our study showed that nonfluoroscopic electromechanical mapping can accurately assess regional wall motion. In addition, this study showed a significant decrease in unipolar voltages among segments with declining regional function.


Assuntos
Mapeamento Potencial de Superfície Corporal , Doença das Coronárias/complicações , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico , Análise de Variância , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Doença das Coronárias/diagnóstico , Eletrodos , Feminino , Fluoroscopia , Humanos , Masculino , Probabilidade , Valores de Referência , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/etiologia
18.
Circulation ; 102(12): 1434-9, 2000 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-10993864

RESUMO

BACKGROUND: Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. METHODS AND RESULTS: We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm(3)) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm(3)) compared with low-activity radioactive stent implantation (NIH 21.2 mm(3)) and conventional stent implantation (NIH 20.8 mm(3)) (P:=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. CONCLUSIONS: Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.


Assuntos
Doença das Coronárias/terapia , Stents , Túnica Íntima/patologia , Adulto , Idoso , Doença das Coronárias/patologia , Doença das Coronárias/radioterapia , Feminino , Seguimentos , Humanos , Hiperplasia/prevenção & controle , Hiperplasia/radioterapia , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Recidiva , Estudos Retrospectivos , Túnica Íntima/efeitos da radiação
19.
Am J Cardiol ; 86(4): 390-4, 2000 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-10946030

RESUMO

This study evaluated the intermediate-term follow-up after excimer laser coronary angioplasty (ELCA) and adjunctive percutaneous transluminal coronary angioplasty (PTCA) in patients with diffuse in-stent restenosis (lesion length >10 mm). Clinical and angiographic follow-up were performed at 6 months. Quantitative coronary angiography performed at 3 stages-during stent implantation, before and after ELCA + PTCA, and at follow-up-included measurements of the minimum lumen diameter (MLD) and percent diameter stenosis (DS). Sixteen consecutive patients were included. The (median + range) stent length was 36 mm (range 15 to 105), with a restenotic lesion length of 32 mm (range 10 to 90). After ELCA + PTCA, the MLD increased from 0.60 +/- 0.41 to 2.28 +/- 0.50 mm, whereas the DS decreased from 76 +/- 16% to 22 +/- 8%. Despite adjunctive high-pressure PTCA, the MLD after ELCA + PTCA remained smaller than the MLD after initial stent implantation, (2.28 +/- 0. 50 mm vs 2.67 +/- 0.32 mm, p = 0.014). Adverse events included ELCA-related acute coronary occlusion in 4 patients and a per-procedural intracerebral hematoma in 1. At 6 months, there was recurrence of angina in all patients. Angiographic follow-up was completed in 13 patients (87%), showing a reocclusion in 6 (46%), a >50% DS in 6 (MLD 1.03 +/- 0.87 mm, DS 68 +/- 24%), and a distal de novo lesion in 1. Despite satisfactory acute angiographic results, the recurrence of significant restenosis in all patients suggests that ELCA + PTCA is not a suitable stand-alone therapy for diffuse in-stent restenosis of long stented segments.


Assuntos
Angioplastia Coronária com Balão , Angioplastia com Balão a Laser , Doença das Coronárias/terapia , Stents , Terapia Combinada , Angiografia Coronária , Doença das Coronárias/cirurgia , Creatinina/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Recidiva
20.
Heart ; 83(3): 332-7, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10677416

RESUMO

OBJECTIVE: To evaluate the healing of balloon induced coronary artery dissection in individuals who have received beta radiation treatment and to propose a new intravascular ultrasound (IVUS) dissection score to facilitate the comparison of dissection through time. DESIGN: Retrospective study. SETTING: Tertiary referral centre. PATIENTS: 31 patients with stable angina pectoris, enrolled in the beta energy restenosis trial (BERT-1.5), were included. After excluding those who underwent stent implantation, the evaluable population was 22 patients. INTERVENTIONS: Balloon angioplasty and intracoronary radiation followed by quantitative coronary angiography (QCA) and IVUS. Repeat QCA and IVUS were performed at six month follow up. MAIN OUTCOME MEASURES: QCA and IVUS evidence of healing of dissection. Dissection classification for angiography was by the National Heart Lung Blood Institute scale. IVUS proven dissection was defined as partial or complete. The following IVUS defined characteristics of dissection were described in the affected coronary segments: length, depth, arc circumference, presence of flap, and dissection score. Dissection was defined as healed when all features of dissection had resolved. The calculated dose of radiation received by the dissected area in those with healed versus non-healed dissection was also compared. RESULTS: Angiography (type A = 5, B = 7, C = 4) and IVUS proven (partial = 12, complete = 4) dissections were seen in 16 patients following intervention. At six month follow up, six and eight unhealed dissections were seen by angiography (A = 2, B = 4) and IVUS (partial = 7, complete = 1), respectively. The mean IVUS dissection score was 5.2 (range 3-8) following the procedure, and 4.6 (range 3-7) at follow up. No correlation was found between the dose prescribed in the treated area and the presence of unhealed dissection. No change in anginal status was seen despite the presence of unhealed dissection. CONCLUSION: beta radiation appears to alter the normal healing process, resulting in unhealed dissection in certain individuals. In view of the delayed and abnormal healing observed, long term follow up is indicated given the possible late adverse effects of radiation. Although in this cohort no increase in cardiac events following coronary dissections was seen, larger populations are needed to confirm this phenomenon. Stenting of all coronary dissections may be warranted in patients scheduled for brachytherapy after balloon angioplasty.


Assuntos
Angina Pectoris/radioterapia , Angioplastia Coronária com Balão/efeitos adversos , Aneurisma Coronário/fisiopatologia , Vasos Coronários/efeitos da radiação , Cicatrização/efeitos da radiação , Angina Pectoris/terapia , Partículas beta/efeitos adversos , Partículas beta/uso terapêutico , Estudos de Coortes , Aneurisma Coronário/etiologia , Angiografia Coronária , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...