1.
Anal Sci ; 24(6): 739-44, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18544862

RESUMO

A robotized sample-preparation method for the determination of Pu, which is recovered by extraction reprocessing of spent nuclear fuel, by isotope dilution mass spectrometry (IDMS) is described. The automated system uses a six-axis industrial robot, whose motility is very fast, accurate, and flexible, installed in a glove box. The automation of the weighing and dilution steps enables operator-unattended sample pretreatment for the high-precision analysis of Pu in aqueous solutions. Using the developed system, the Pu concentration in a HNO(3) medium was successfully determined using a set of subsequent mass spectrometric measurements. The relative uncertainty in determining the Pu concentration by IDMS using this system was estimated to be less than 0.1% (k = 2), which is equal to that expected of a talented analyst. The operation time required was the same as that for a skilled operator.

2.
Anal Sci ; 24(4): 527-30, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18403847

RESUMO

Laser-induced photoacoustic spectroscopy was used in a quantitative analysis of Pu in HNO3 medium. Plutonium was quantitatively oxidized to Pu(VI) using Ce(IV). The photoacoustic measurement of Pu(VI) with maximum absorption at 830.5 nm was subsequently performed to determine the concentration. The photoacoustic signal was linearly proportional to the Pu(VI) ion concentration. The detection limit of Pu(VI) was estimated to be 0.5 microg mL(-1) (3sigma) in 3 M HNO3. By the proposed method, Pu concentration was successfully determined in a nuclear waste solution for use in nuclear materials management.

3.
Anal Sci ; 24(3): 377-80, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18332546

RESUMO

A simple and rapid spectrophotometric method has been developed for the determination of Pu in highly radioactive liquid waste. This method uses Nd(III) as an internal standard, which enables us to determine the concentration of Pu and to authenticate the whole analytical scheme as well. A Nd(III) standard mixed with a sample solution and Pu was quantitatively oxidized to Pu(VI) with Ce(IV) in a nitric acid medium, having the maximum absorbance at 830 nm. A spectrophotometric measurement of Pu(VI) was subsequently performed to determine the concentration compared with the maximum absorbance of Nd(III) at 795 nm. It was estimated that the relative expanded uncertainty for a real sample is less than 10%. The limit of detection was calculated to be 1.8 mg/L (3 sigma). The proposed method was also validated through comparison experiments with isotope dilution mass spectrometry, and was successfully applied to analysis for nuclear waste management at spent nuclear fuel reprocessing plants.


Assuntos
Neodímio/química , Plutônio/análise , Resíduos Radioativos/análise , Espectrofotometria/métodos , Espectrofotometria/normas , Poluentes Radioativos da Água/análise , Calibragem , Cério/química , Neodímio/normas , Oxirredução , Plutônio/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria/instrumentação , Poluentes Radioativos da Água/normas