Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
Circ Arrhythm Electrophysiol ; : e012723, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690671

RESUMO

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.

3.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38523591

RESUMO

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Assuntos
Fibrilação Atrial , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Masculino , Feminino , Criocirurgia/métodos , Fibrilação Atrial/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Sistema de Registros , Qualidade de Vida , Idoso , Ablação por Radiofrequência/métodos
5.
J Interv Card Electrophysiol ; 67(3): 513-521, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37530968

RESUMO

BACKGROUND: Patients with ventricular tachycardia (VT) who require VT ablation are at high risk for readmission. This study aimed to identify the causes and outcomes of 30-day readmission after VT ablation and to analyze the predictors of recurrent VT that required rehospitalization. METHODS: Using the Nationwide Readmission Database, our study included patients aged ≥ 18 years who underwent VT catheter ablation between 2017 and 2020. Based on the International Classification of Diseases, Tenth Revision, Clinical Modification (ICD-10-CM), we identified the causes of 30-day readmission by organ systems and analyzed their outcomes. Additional analysis was performed to determine the independent predictors of 30-day readmission for recurrent VT. RESULTS: Of the 4228 patients who underwent VT ablation, 14.2% were readmitted within 30 days of the procedure. The most common cause of readmission was cardiac events (73.6%). Among the cardiac-related readmissions, recurrent VT (47.7%) and congestive heart failure (CHF) (12.9%) were the most common etiologies. Among the readmissions, patients readmitted for CHF had the highest rate of readmission mortality (9.2%). Of the patients readmitted within 30 days of the procedure, 278 patients (6.8%) were readmitted for recurrent VT. Via multivariable analysis, CHF (OR: 1.97; 95% CI: 1.12-3.47; P = 0.02) and non-elective index admissions (OR: 1.63; 95% CI: 1.04-2.55; P = 0.03) were identified as the independent predictors predictive of 30-day readmissions for recurrent VT. CONCLUSIONS: Recurrent VT was the most common cause of readmission after the VT ablation procedure, and CHF and non-elective index admissions were the significant predictors of these early readmissions. Readmission due to CHF had the highest mortality rate during readmission.


Assuntos
Ablação por Cateter , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Readmissão do Paciente , Resultado do Tratamento , Hospitalização , Insuficiência Cardíaca/complicações , Ablação por Cateter/métodos
6.
JACC Clin Electrophysiol ; 10(2): 222-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37978965

RESUMO

BACKGROUND: The efficacy of pulsed field ablation (PFA) for redo procedures is unknown. OBJECTIVES: In this study, the authors aimed to evaluate the effectiveness of PFA when performing PFA over chronic RFA (redo environment). METHODS: This was a 3-step in vivo study. In step 1 (creation of redo environment), 6 swine underwent radiofrequency ablation (RFA) with a local impedance measuring catheter and a contact force-enabled catheter in 3 different sites: the right atrium (RA) (intercaval line with intentional gaps), the left atrium (LA) (pulmonary vein isolation [PVI] with intentional gaps and superficial posterior wall ablations), and the left ventricle (LV) (short RFA applications [chronic RFA]). In step 2 (re-ablation), following a survival period of ≈5 weeks, animals were retreated as follows: in the RA, a focal PFA catheter over the prior intercaval line; in the LA, PVI using a pentaspline PFA catheter; and in the LV, animals were randomized to focal PFA or RFA. In each arm, 2 types of lesions were performed: acute or acute over chronic. In step 3 (remapping and euthanization), following an additional 3 to 5 days, all animals were remapped and sacrificed. RESULTS: In the RA, re-ablation with PFA resulted in a complete intercaval block in all animals, expanding and homogenizing the disparate chronic RFA lesions from a width of 4 to 7 mm (chronic RFA) to a width of 16 to 28 mm (PFA over chronic RFA). In the LA, re-ablation with PFA resulted in complete PVI and transmural ablation of the PW. In the LV, the mean depth for acute RFA (post 2-5 days survival) was 7.6 ± 1.3 mm vs 3.9 ± 1.6 mm in the acute over chronic RFA lesions (P < 0.01). In contrast, the mean depth for acute PFA was 7.0 ± 1.6 mm, similar to when ablating with PFA over RFA (7.1 ± 1.3 mm; P = 0.94). CONCLUSIONS: PFA is highly efficient for ablation following prior RFA, which may be beneficial in patients presenting for redo procedures. In the ventricle, PFA resulted in lesions that are deeper than RFA when ablating over chronic superficial RFA lesions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Humanos , Animais , Suínos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Catéteres , Impedância Elétrica
7.
Circ Arrhythm Electrophysiol ; 17(1): e012026, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152949

RESUMO

BACKGROUND: Effects of contact force (CF) on lesion formation during pulsed field ablation (PFA) have not been well validated. The purpose of this study was to determine the relationship between average CF and lesion size during PFA using a swine-beating heart model. METHODS: A 7F catheter with a 3.5-mm ablation electrode and CF sensor (TactiCath SE, Abbott) was connected to a PFA system (CENTAURI, Galvanize Therapeutics). In 5 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and a skin patch at 40 separate sites in right ventricle (28 Amp) and 55 separate sites in left ventricle (35 Amp) with 4 different levels of CF: (1) low (CF range of 4-13 g; median, 9.5 g); (2) moderate (15-30 g; median, 21.5 g); (3) high (34-55 g; median, 40 g); and (4) no electrode contact, 2 mm away from the endocardium. Swine were sacrificed at 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. In 1 additional swine, COX (cytochrome c oxidase) staining was performed to examine mitochondrial activity to delineate reversible and irreversible lesion boundaries. Histological examination was performed with hematoxylin and eosin and Masson trichrome staining. RESULTS: Ablation lesions were well demarcated with triphenyl tetrazolium chloride staining, showing (1) a dark central zone (contraction band necrosis and hemorrhage); (2) a pale zone (no mitochondrial activity and nuclear pyknosis, indicating apoptosis zone); and a hyperstained zone by triphenyl tetrazolium chloride and COX staining (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). At constant PFA current intensity, lesion depth increased significantly with increasing CF. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions show irreversible and reversible lesion boundaries by triphenyl tetrazolium chloride staining. Electrode-tissue contact is required for effective lesion formation during PFA. At the same PFA dose, lesion depth increases significantly with increasing CF.


Assuntos
Ablação por Cateter , Ventrículos do Coração , Suínos , Animais , Ventrículos do Coração/cirurgia , Ventrículos do Coração/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cloretos , Coração , Catéteres
8.
Heliyon ; 9(11): e22178, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38045193

RESUMO

Background: Atrial fibrillation (AF) catheter ablation has become an increasingly effective and safe strategy for the management of AF. With increased safety of catheter ablation, same-day discharge (SDD) is a potential way to minimize health care resource utilization and improve patient experience. Objective: To evaluate the safety and patient satisfaction of SDD after contemporary AF ablation. Methods: Consecutive patient undergoing AF ablation at our institution between 1/2020 and 10/2021 were enrolled in registry for clinical, quality, procedural and outcomes data. Patients were considered for SDD per physician discretion and patients' preference based upon clinical evaluation. Adjudicated ninety-day major complications, thirty-day adverse events, and thirty-day re-admissions were collected in a prospective registry for all patients. Results: A total of 2142 consecutive patients underwent elective AF ablation during the study period. After excluding cases with missing data, 1830 patients were included in the analysis. Of those, 350 (19 %) patients were discharged the same day (SDD group) and 1480 (81 %) stayed overnight. Patients in the SDD group compared to overnight stay group were younger, more likely to be male, White patients, lower CHA2DS2-VASc score and to be on lower rates of warfarin as an anticoagulation strategy. After propensity score matching, SDD was associated with lower rate of major complications and higher patient satisfaction. The majority of life-treating complications occurred interprocedurally or within 6 h of procedure termination. Conclusion: The present study demonstrated that SDD after contemporary AF ablation is feasible, safe and associated with higher patient satisfaction using a proposed SDD pathway and criteria.

9.
Eur Heart J Open ; 3(6): oead127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38105920

RESUMO

Aims: Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and results: This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI): 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047]. Conclusion: Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.

11.
Artigo em Inglês | MEDLINE | ID: mdl-37848806

RESUMO

BACKGROUND: Atrial fibrillation (AF) risk increases with age. We aim to assess the efficacy and safety of catheter ablation in the older population. METHODS: All patients undergoing AF ablation (2013-2021) at our institution were enrolled in a prospectively maintained registry. The primary endpoint was AF recurrence. Patients were divided into 3 groups: non-elderly (< 65 years), elderly (65-75 years), and very elderly (> 75 years). Patient surveys at baseline and during follow-up were used to calculate quality of life (QoL) metrics: the AF severity score as well as the AF burden. RESULTS: A total of 7020 patients were included (42% non-elderly, 42% elderly, and 16% very elderly). Periprocedural major complications were low (< 1.5%) and similar in all groups besides pericardial effusion which was more frequent with older age and similar between the elderly and very elderly. At 3 years, AF recurrence for persistent AF (PersAF) was highest in the very elderly group (48%), followed by the elderly group (42%), and was the lowest in the non-elderly group (36%). In paroxysmal AF (PAF), there was no difference in AF recurrence between the elderly and non-elderly, while the very elderly remained associated with a significantly increased risk. Multivariable Cox analysis confirmed these findings (PersAF; elderly: HR = 1.23, P = 0.003; very elderly: HR = 1.44, P < 0.001) (PAF; elderly: HR = 1.04, P = 0.62; very elderly: HR = 1.30, P = 0.01). Catheter ablation resulted in a significant improvement in quality of life, irrespective of age group. CONCLUSION: Catheter ablation in elderly and very elderly patients is safe, efficacious, and associated with QoL benefits. Overall, major complications were minimal and did not differ significantly between age groups, with the exception of pericardial effusions which were higher in the elderly and very elderly compared to non-elderly adults. Very elderly patients had a higher rate of AF recurrence when compared with elderly or non-elderly patients. Nevertheless, ablation resulted in a remarkable improvement in QoL and a reduction of AF burden and AF symptoms with a similar magnitude, irrespective of age.

12.
JACC Clin Electrophysiol ; 9(9): 1890-1899, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37542488

RESUMO

BACKGROUND: Monomorphic ventricular tachycardia (VT) electrical storm (ES) in patients with coronary artery disease is dependent on scarred myocardium. The role of routine ischemic or coronary evaluations before ablation in patients presenting with monomorphic VT storm, without acute coronary syndrome (ACS), remains unknown. OBJECTIVES: This study sought to assess the impact of ischemic or coronary evaluations on procedural outcomes and post-ablation mortality in monomorphic VT storm patients. METHODS: All patients undergoing VT ablation at the Cleveland Clinic from 2014 to 2020 after presenting with monomorphic VT storm were enrolled in a prospectively maintained registry. The associations among ischemic or coronary evaluations and short-term procedural efficacy, acute outcomes, and mortality during follow-up were assessed. RESULTS: A total of 97 consecutive patients with monomorphic VT storm in the absence of ACS underwent VT ablations. This cohort was characterized by severe LV systolic dysfunction (mean left ventricular ejection fraction 30.3%, 67% with known ischemic cardiomyopathy) with moderately severe heart failure (median NYHA functional class II); 45% of patients underwent ischemic or coronary evaluations via coronary angiography (10%), noninvasive myocardial perfusion (26%), or both (9%). The yield of these evaluations was low: No acute coronary occlusions were identified. There was no association between ischemic evaluation and acute ablation outcomes or mortality during follow-up. Similarly, in a secondary analysis, the yield of ischemic or coronary evaluations in patients with monomorphic VT storm and known coronary disease (regardless of ablation status) was found to be low. CONCLUSIONS: Ischemic evaluations in patients with monomorphic VT storm without ACS may not improve procedural outcomes or mortality after ablation.


Assuntos
Síndrome Coronariana Aguda , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Volume Sistólico , Função Ventricular Esquerda , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Síndrome Coronariana Aguda/complicações , Ablação por Cateter/efeitos adversos
14.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493505

RESUMO

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Sobrepeso/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Obesidade/complicações , Obesidade/diagnóstico , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 34(8): 1595-1604, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37453072

RESUMO

INTRODUCTION: Use of sodium glucose cotransporter 2 inhibitors (SGLT2i) was associated with a reduction in atrial fibrillation hospitalizations. Therefore, we aim to evaluate the effects of SGLT2i on atrial tachy-arrhythmias (ATA) in patients with cardiac implantable electronic devices (CIEDs). METHODS: All 13 888 consecutive patients implanted with a CIED in two tertiary medical centers were enrolled. Treatment with SGLT2i was assessed as a time dependent variable. The primary endpoint was the total number of ATA. Secondary endpoints included total number of ventricular tachy-arrhythmias (VTA), ATA and VTA, and death. All events were independently adjudicated blinded to the treatment. Multivariable propensity score modeling was performed. RESULTS: During a total follow-up of 24 442 patient years there were 62 725 ATA and 10 324 VTA events. Use of SGLT2i (N = 696) was independently associated with a significant 22% reduction in the risk of ATA (hazard ratio [HR] = 0.78 [95% confidence interval {CI} = 0.70-0.87]; p < .001); 22% reduction in the risk of ATA/VTA (HR = 0.78 [95% CI = 0.71-0.85]; p < .001); and with a 35% reduction in the risk of all-cause mortality (HR = 0.65 [95% CI = 0.45-0.92]; p = .015), but was not significantly associated with VTA risk (HR = 0.92 [95% CI = 0.80-1.06]; p = .26). SGLT2i were associated with a lower ATA burden in heart failure (HF) patients but not among diabetes patients (HF: HR = 0.68, 95% CI = 0.58-0.80, p < .001 vs. Diabetes: HR = 0.95, 95% CI = 0.86-1.05, p = .29; p < .001 for interaction between SGLT2i indication and ATA burden). CONCLUSION: Our real world findings suggest that in CIED HF patients, those with SGLT2i had a pronounced reduction in ATA burden and all-cause mortality when compared with those not on SGLT2i.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Fibrilação Atrial/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Glucose
17.
Circulation ; 148(3): 241-252, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37459413

RESUMO

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Feminino , Estados Unidos/epidemiologia , Masculino , Brancos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiologia , Prevenção Primária
18.
JACC Clin Electrophysiol ; 9(9): 2008-2023, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37354168

RESUMO

Catheter ablation of arrhythmias is now standard of care in invasive electrophysiology. Current ablation strategies are based on the use of thermal energy. With continuous efforts to optimize thermal energy delivery, effectiveness has greatly improved; however, safety concerns persist. This review focuses on a novel ablation technology, irreversible electroporation (IRE), also known as pulsed-field ablation which may be a safer alternative for arrhythmia management. Pulsed-field ablation is thought to be a nonthermal ablation that applies short-duration high-voltage electrical fields to ablate myocardial tissue with high selectivity and durability while sparing important neighboring structures such as the esophagus and phrenic nerves. There are multiple ongoing studies investigating the potential superior outcomes of IRE compared to radiofrequency ablation in treating patients with atrial and ventricular arrhythmias. In this review, we describe the current evidence of preclinical and clinical trials that have shown promising results of catheter-based IRE.


Assuntos
Arritmias Cardíacas , Ablação por Cateter , Humanos , Arritmias Cardíacas/cirurgia , Eletroporação/métodos , Terapia com Eletroporação , Catéteres , Ablação por Cateter/métodos
19.
Circ Arrhythm Electrophysiol ; 16(6): e011565, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183675

RESUMO

BACKGROUND: Ablation is used for both rhythm control and improved quality of life (QoL) in atrial fibrillation (AF). It has been suggested that young adults may experience high recurrence rates after ablation and data remain lacking regarding QoL benefits. We aimed to investigate AF ablation outcomes and QoL benefits in young adults undergoing AF ablation using a large prospectively maintained registry and automated patient-reported outcomes (PRO). METHODS: All patients undergoing AF ablation (2013-2016) at our center were prospectively enrolled. Patients aged 50 years or younger were included. For PROs, QoL measures and symptoms were assessed at baseline, 3 months after ablation, and every 6 months thereafter. The AF severity score served as the main assessment of QoL. RESULTS: A total of 241 young adults (age, 16-50 years) were included (17% female, 40.3% persistent AF). In all, 77.2% of patients remained arrhythmia-free during the first year of follow-up (80% in nonstructural AF and 66% in structural AF). Using PROs, 90% of patients reported improvement in QoL throughout all survey time points up to 5 years postablation (P<0.0001). The baseline median AF severity score was 14 and improved to between 2 and 4 on all follow-up after ablation (P<0.0001). Patients also reported fewer and shorter AF episodes, fewer emergency room visits secondary to AF, and fewer hospitalizations (P<0.0001). CONCLUSIONS: Ablation remains an effective rhythm-control strategy in young adults with AF. Young adults also experience significant improvement in QoL with reduction of the frequency and duration of AF episodes and AF-related healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Feminino , Adulto Jovem , Adolescente , Adulto , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva
20.
medRxiv ; 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37205384

RESUMO

Background: Black Americans have a higher risk of non-ischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate racial disparities in the risk of tachyarrhythmias among patients with an implantable cardioverter defibrillator (ICD). Methods: The study population comprised 3,895 ICD recipients enrolled in the U.S. in primary prevention ICD trials. Outcome measures included first and recurrent ventricular tachy-arrhythmia (VTA) and atrial tachyarrhythmia (ATA), derived from adjudicated device data, and death. Outcomes were compared between self-reported Black vs. White patients with a cardiomyopathy (ischemic [ICM] and NICM). Results: Black patients were more likely to be female (35% vs 22%) and younger (57±12 vs 62±12) with a higher frequency of comorbidities. Blacks patients with NICM compared with Whites patients had a higher rate of first VTA, fast VTA, ATA, appropriate-, and inappropriate-ICD-therapy (VTA≥170bpm: 32% vs. 20%; VTA≥200bpm: 22% vs. 14%; ATA: 25% vs. 12%; appropriate 30% vs 20%; and inappropriate: 25% vs. 11%; p<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia/ICD-therapy (VTA≥170bpm: HR=1.69; VTA≥200bpm: HR=1.58; ATA: HR=1.87; appropriate: HR=1.62; and inappropriate: HR=1.86; p≤0.01 for all), higher burden of VTA, ATA, ICD therapies, and a higher risk of death (HR=1.86; p=0.014). In contrast, in ICM, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black and White patients. Conclusions: Among NICM patients with an ICD for primary prevention, Black compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies. Clinical Perspective: What Is New?: Black patients have a higher risk of developing non-ischemic cardiomyopathy (NICM) but are under-represented in clinical trials of implantable cardioverter defibrillators (ICD). Therefore, data on disparities in the presentation and outcomes in this population are limited.This analysis represents the largest group of self-identified Black patients implanted in the U.S. with an ICD for primary prevention with adjudication of all arrhythmic events.What Are the Clinical Implications?: In patients with a NICM, self-identified Black compared to White patients experienced an increased incidence and burden of ventricular tachyarrhythmia, atrial tachyarrhythmia, and ICD therapies. These differenced were not observed in Black vs White patients with ischemic cardiomyopathy (ICM).Although Black patients with NICM were implanted at a significantly younger age (57±12 vs 62±12 years), they experienced a 2-fold higher rate of all-cause mortality during a mean follow up of 3 years compared with White patients.These findings highlight the need for early intervention with an ICD, careful monitoring, and intensification of heart failure and antiarrhythmic therapies among Black patients with NICM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...