Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
MAGMA ; 26(2): 215-28, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23014944

RESUMO

OBJECT: To construct an optimised, high-density receive array and a movement device to achieve dynamic imaging of the knee in orthopedic large animal models (e.g., minipigs) at 1.5 T. MATERIALS AND METHODS: A 13-channel RF receive array was constructed, and the crucial choice of the array element size (based on considerations like region of interest, geometry of the minipig's knee, achievable signal-to-noise ratio, applicability of parallel imaging, etc.) was determined using the Q factors of loops with different sizes. A special movement device was constructed to guide and produce a reproducible motion of the minipig's knee during acquisition. RESULTS: The constructed array was electrically characterised and the reproducibility of the cyclic motion was validated. Snapshots of dynamic in vivo images taken at a temporal resolution (308 ms) are presented. Some of the fine internal structures within the minipig's knee, like cruciate ligaments, are traced in the snapshots. CONCLUSION: This study is a step towards making dynamic imaging which can give additional information about joint injuries when static MRI is not able to give sufficient information, a routine clinical application. There, the combination of a high-density receive array and a movement device will be highly helpful in the diagnosis and therapy monitoring of knee injuries in the future.


Assuntos
Articulações/anatomia & histologia , Articulações/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Animais , Fenômenos Biomecânicos , Desenho de Equipamento , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos Animais , Imagens de Fantasmas , Suínos , Porco Miniatura/anatomia & histologia , Porco Miniatura/fisiologia , Gravação em Vídeo
2.
MAGMA ; 24(4): 247-58, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21630094

RESUMO

OBJECT: To investigate the relationship of the different diffusion tensor imaging (DTI) parameters (ADC, FA, and first eigenvector (EV)) to the constituents (proteoglycans and collagen), the zonal arrangement of the collagen network, and mechanical loading of articular cartilage. MATERIAL AND METHODS: DTI of eight cartilage-on-bone samples of healthy human patellar cartilage was performed at 17.6 T. Three samples were additionally imaged under indentation loading. After DTI, samples underwent biomechanical testing, safranin-O staining for semiquantitative proteoglycan estimation, and scanning electron microscopy (SEM) for depicting collagen architecture. RESULTS: From the articular surface to the bone-cartilage interface, ADC continuously decreased and FA increased. Cartilage zonal heights calculated from EVs strongly correlated with SEM-derived zonal heights (P < 0.01, r (2)=0.87). Compression reduced ADC in the superficial 30% of cartilage and increased FA in the superficial 5% of cartilage. Reorientation of the EVs indicative of collagen fiber reorientation under the indenter was observed. No significant correlation was found between ADC, FA, and compressive stiffness. CONCLUSIONS: Correlating ADC and FA with proteoglycan and collagen content suggests that diffusion is dominated by different depth-dependent mechanisms within cartilage. Knowledge of the spatial distribution of the DTI parameters and their variation contributes to form a database for future analysis of defective cartilage.


Assuntos
Fenômenos Biomecânicos/fisiologia , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/citologia , Imagem de Tensor de Difusão/métodos , Microscopia Eletrônica de Varredura/métodos , Adulto , Anisotropia , Cartilagem Articular/ultraestrutura , Colágeno/análise , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Patela/anatomia & histologia , Patela/citologia , Proteoglicanas/análise , Proteoglicanas/ultraestrutura
3.
J Magn Reson ; 182(1): 152-9, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16837222

RESUMO

Diffusion-weighted imaging in the presence of extremely short T2-relaxation time is generally not feasible with a standard PGSE experiment due to the superposed signal decays caused primarily by T2-relaxation and secondarily by diffusion. Here, we present a new method for diffusion-weighted imaging achieved by a nearly T2-independent pre-experiment where a DANTE-pulse train is repeated rapidly.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...