Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Data ; 9(1): 73, 2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35277516

RESUMO

This data set is the first-of-its-kind spatial representation of multi-seasonal, global C-band Synthetic Aperture Radar (SAR) interferometric repeat-pass coherence and backscatter signatures. Coverage comprises land masses and ice sheets from 82° Northern to 79° Southern latitudes. The data set is derived from multi-temporal repeat-pass interferometric processing of about 205,000 Sentinel-1 C-band SAR images acquired in Interferometric Wide-Swath Mode from 1-Dec-2019 to 30-Nov-2020. The data set encompasses three sets of seasonal (December-February, March-May, June-August, September-November) metrics produced with a pixel spacing of three arcseconds: 1) Median 6-, 12-, 18-, 24-, 36-, and 48-days repeat-pass coherence at VV or HH polarizations, 2) Mean radiometrically terrain corrected backscatter (γ0) at VV and VH, or HH and HV polarizations, and 3) Estimated parameters of an exponential coherence decay model. The data set has been produced to obtain global, spatially detailed information on how decorrelation affects interferometric measurements of surface displacement and is rich in spatial and temporal information for a variety of mapping applications.

2.
Sci Rep ; 7(1): 12035, 2017 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-28931843

RESUMO

We measured ground displacements before and after the 2009 L'Aquila earthquake using multi-temporal InSAR techniques to identify seismic precursor signals. We estimated the ground deformation and its temporal evolution by exploiting a large dataset of SAR imagery that spans seventy-two months before and sixteen months after the mainshock. These satellite data show that up to 15 mm of subsidence occurred beginning three years before the mainshock. This deformation occurred within two Quaternary basins that are located close to the epicentral area and are filled with sediments hosting multi-layer aquifers. After the earthquake, the same basins experienced up to 12 mm of uplift over approximately nine months. Before the earthquake, the rocks at depth dilated, and fractures opened. Consequently, fluids migrated into the dilated volume, thereby lowering the groundwater table in the carbonate hydrostructures and in the hydrologically connected multi-layer aquifers within the basins. This process caused the elastic consolidation of the fine-grained sediments within the basins, resulting in the detected subsidence. After the earthquake, the fractures closed, and the deep fluids were squeezed out. The pre-seismic ground displacements were then recovered because the groundwater table rose and natural recharge of the shallow multi-layer aquifers occurred, which caused the observed uplift.

3.
Sensors (Basel) ; 10(1): 584-612, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22315556

RESUMO

L-band (1-2 GHz) microwave radiometry is a remote sensing technique that can be used to monitor soil moisture, and is deployed in the Soil Moisture and Ocean Salinity (SMOS) Mission of the European Space Agency (ESA). Performing ground-based radiometer campaigns before launch, during the commissioning phase and during the operative SMOS mission is important for validating the satellite data and for the further improvement of the radiative transfer models used in the soil-moisture retrieval algorithms. To address these needs, three identical L-band radiometer systems were ordered by ESA. They rely on the proven architecture of the ETH L-Band radiometer for soil moisture research (ELBARA) with major improvements in the microwave electronics, the internal calibration sources, the data acquisition, the user interface, and the mechanics. The purpose of this paper is to describe the design of the instruments and the main characteristics that are relevant for the user.


Assuntos
Monitoramento Ambiental/instrumentação , Radiometria/instrumentação , Tecnologia de Sensoriamento Remoto/instrumentação , Solo/análise , Solo/química , Transdutores , Água/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Micro-Ondas , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...