Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev E ; 103(3): L031201, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33862680

RESUMO

Achieving a high conversion efficiency into relativistic electrons is central to short-pulse laser application and fundamentally relies on creating interaction regions with intensities ≫10^{18}W/cm^{2}. Small focal length optics are typically employed to achieve this goal; however, this solution is impractical for large kJ-class systems that are constrained by facility geometry, debris concerns, and component costs. We fielded target-mounted compound parabolic concentrators to overcome these limitations and achieved nearly an order-of-magnitude increase to the conversion efficiency and more than tripled electron temperature compared to flat targets. Particle-in-cell simulations demonstrate that plasma confinement within the cone and formation of turbulent laser fields that develop from cone wall reflections are responsible for the improved laser-to-target coupling. These passive target components can be used to improve the coupling efficiency for all high-intensity short-pulse laser applications, particularly at large facilities with long focal length optics.

2.
Opt Express ; 22(23): 28845-56, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402124

RESUMO

Modeling the lifetime of a fused silica optic is described for a multiple beam, MJ-class laser system. This entails combining optic processing data along with laser shot data to account for complete history of optic processing and shot exposure. Integrating with online inspection data allows for the construction of a performance metric to describe how an optic performs with respect to the model. This methodology helps to validate the damage model as well as allows strategic planning and identifying potential hidden parameters that are affecting the optic's performance.


Assuntos
Lasers , Modelos Teóricos , Óptica e Fotônica , Estatística como Assunto , Estresse Mecânico , Cor , Lentes
3.
Magn Reson Med ; 70(6): 1718-27, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23382056

RESUMO

PURPOSE: The determination of right ventricular volumes and function is of increasing interest for the postoperative care of patients with congenital heart defects. The presentation of volumetry data in terms of volume-time curves allows a comprehensive functional assessment. By using manual contour tracing, the generation of volume-time curves is exceedingly time-consuming. METHODS: This study describes a fast and precise method for determining volume-time curves for the right ventricle and for the right ventricular outflow tract. The method applies contour detection and includes a feature for identifying the right ventricular outflow tract volume. The segregation of the outflow tract is performed by four-dimensional curved smooth boundary surfaces defined by prespecified anatomical landmarks. RESULTS: The comparison with manual contour tracing demonstrates that the method is accurate and improves the precision of the measurement. Compared to manual contour tracing the bias is <0.1% ± 4.1% (right ventricle) and -2.6% ± 20.0% (right ventricular outflow tract). The standard deviations of inter- and intraobserver variabilities for determining the volume of the right ventricular outflow tract are reduced to less than half the values of manual contour tracing. The time consumption per patient is reduced from 341 ± 80 min (right ventricle) and 56 ± 11 min (right ventricular outflow tract) using manual contour tracing to 46 ± 9 min for a combined analysis of right ventricle and right ventricular outflow tract. CONCLUSION: The analysis of volume-time curves for the right ventricle and its outflow tract discloses new evaluation methods in clinical routine and science.


Assuntos
Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/fisiopatologia , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Algoritmos , Volume Cardíaco , Cardiopatias Congênitas/complicações , Ventrículos do Coração/patologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Obstrução do Fluxo Ventricular Externo/etiologia
4.
Science ; 327(5970): 1228-31, 2010 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-20110465

RESUMO

Indirect-drive hohlraum experiments at the National Ignition Facility have demonstrated symmetric capsule implosions at unprecedented laser drive energies of 0.7 megajoule. One hundred and ninety-two simultaneously fired laser beams heat ignition-emulate hohlraums to radiation temperatures of 3.3 million kelvin, compressing 1.8-millimeter-diameter capsules by the soft x-rays produced by the hohlraum. Self-generated plasma optics gratings on either end of the hohlraum tune the laser power distribution in the hohlraum, which produces a symmetric x-ray drive as inferred from the shape of the capsule self-emission. These experiments indicate that the conditions are suitable for compressing deuterium-tritium-filled capsules, with the goal of achieving burning fusion plasmas and energy gain in the laboratory.

5.
Appl Opt ; 47(19): 3494-9, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18594596

RESUMO

A single beamline of the National Ignition Facility (NIF) has been operated at a wavelength of 526.5 nm (2 omega) by frequency converting the fundamental 1053 nm (1 omega) wavelength with an 18.2 mm thick type-I potassium dihydrogen phosphate (KDP) second-harmonic generator (SHG) crystal. Second-harmonic energies of up to 17.9 kJ were measured at the final optics focal plane with a conversion efficiency of 82%. For a similarly configured 192-beam NIF, this scales to a total 2 omega energy of 3.4 MJ full NIF equivalent (FNE).

6.
Appl Opt ; 46(16): 3276-303, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17514286

RESUMO

The National Ignition Facility (NIF) is the world's largest laser system. It contains a 192 beam neodymium glass laser that is designed to deliver 1.8 MJ at 500 TW at 351 nm in order to achieve energy gain (ignition) in a deuterium-tritium nuclear fusion target. To meet this goal, laser design criteria include the ability to generate pulses of up to 1.8 MJ total energy, with peak power of 500 TW and temporal pulse shapes spanning 2 orders of magnitude at the third harmonic (351 nm or 3omega) of the laser wavelength. The focal-spot fluence distribution of these pulses is carefully controlled, through a combination of special optics in the 1omega (1053 nm) portion of the laser (continuous phase plates), smoothing by spectral dispersion, and the overlapping of multiple beams with orthogonal polarization (polarization smoothing). We report performance qualification tests of the first eight beams of the NIF laser. Measurements are reported at both 1omega and 3omega, both with and without focal-spot conditioning. When scaled to full 192 beam operation, these results demonstrate, to the best of our knowledge for the first time, that the NIF will meet its laser performance design criteria, and that the NIF can simultaneously meet the temporal pulse shaping, focal-spot conditioning, and peak power requirements for two candidate indirect drive ignition designs.

7.
Phys Rev Lett ; 95(21): 215004, 2005 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-16384150

RESUMO

The first hohlraum experiments on the National Ignition Facility (NIF) using the initial four laser beams tested radiation temperature limits imposed by plasma filling. For a variety of hohlraum sizes and pulse lengths, the measured x-ray flux shows signatures of filling that coincide with hard x-ray emission from plasma streaming out of the hohlraum. These observations agree with hydrodynamic simulations and with an analytical model that includes hydrodynamic and coronal radiative losses. The modeling predicts radiation temperature limits with full NIF (1.8 MJ), greater, and of longer duration than required for ignition hohlraums.

8.
Appl Opt ; 40(9): 1404-11, 2001 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-18357129

RESUMO

Efficient frequency doubling and tripling are critical to the successful operation of inertial confinement fusion laser systems such as the National Ignition Facility currently being constructed at the Lawrence Livermore National Laboratory and the Omega laser at the Laboratory for Laser Energetics. High-frequency conversion efficiency is strongly dependent on attainment of the phase-matching condition. In an ideal converter crystal, one can obtain the phase-matching condition throughout by angle tuning or temperature tuning of the crystal as a whole. In real crystals, imperfections in the crystal structure prohibit the attainment of phase matching at all locations in the crystal. We have modeled frequency doubling and tripling with a quantitative measure of this departure from phase matching in real crystals. This measure is obtained from interferometry of KDP and KD*P crystals at two orthogonal light polarizations.

9.
J Am Psychoanal Assoc ; 48(3): 811-38, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11059398

RESUMO

Transference-countertransference involvement with patients the analyst finds "pleasurable" is examined. Analysis of such patients courts the danger that pathological identifications will go unrecognized and the analysis end at a point where the opportunity for decisive change, which to the patient appears physically and psychically catastrophic, is forgone. A presentation of one aspect of the analysis of a young woman reveals the psychic pain experienced by analysand and analyst when the feared breakdown places a pathological identification in doubt, and the difficulties that can ensue in treatment. Other psychodynamic lines of interpretation and differential diagnostic considerations are put aside in favor of an examination of the special role of enactment and countertransference enactment and their impact in promoting development or strengthening defense.


Assuntos
Contratransferência , Amor , Terapia Psicanalítica , Adulto , Feminino , Humanos , Relações Profissional-Paciente , Transtornos Psicofisiológicos/terapia , Resultado do Tratamento
10.
Appl Opt ; 35(6): 890-902, 1996 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-21069085

RESUMO

We have constructed an optical parametric oscillator to generate 75-ps near-transform-limited pulses with wavelengths tunable about 1.053 µm for use in pump-probe studies of self-focusing. The singly resonant oscillator uses a Brewster-cut LiB(3)O(5) crystal that is oriented for type-II phase matching and synchronously pumped by the amplified and frequency-tripled pulse trains from a mode-locked and Q-switched Nd:YLP laser. An intracavity Pockels cell is used to switch out single 0.5-MW pulses at rates of 1 to 10 Hz. The design, construction, and performance of the oscillator are discussed. Measured performance is compared with design predictions and with detailed numerical simulations.

11.
Appl Opt ; 32(14): 2543-54, 1993 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-20820416

RESUMO

We discuss the design and fabrication of 80-cm-diameter random phase plates for target-plane beam smoothing on the Nova laser. Random phase plates have been used in a variety of inertial confinement fusion target experiments, such as studying direct-drive hydrodynamic stability and producing spatially smooth x-ray backlighting sources. These phase plates were produced by using a novel sol-gel dip-coating technique developed by us. The sol-gel phase plates have a high optical damage threshold at the second- and third-harmonic wavelengths of the Nd:glass laser and have excellent optical performance.

12.
Psyche (Stuttg) ; 46(3): 286-307, 1992 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-1581702

RESUMO

The author points out the responsibilities and difficulties an interviewer faces in the initial psychoanalytic interview and discusses different theoretical positions in dealing with countertransference. Apart from "free floating attention" and "free floating responsiveness" he emphasizes the important diagnostic and therapeutic factor of "free floating introspectiveness". Finally, with a clinical example, he demonstrates that countertransference should already be taking place at the beginning stage of an interview.


Assuntos
Contratransferência , Entrevista Psicológica , Interpretação Psicanalítica , Terapia Psicanalítica , Humanos
13.
Appl Opt ; 31(27): 5799-809, 1992 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-20733769

RESUMO

High-powered glass-laser systems with multiple beams, frequency-conversion capabilities, and pulseshaping flexibility have made numerous contributions to the understanding of inertial confinement fusion and related laser-plasma interactions. The Nova laser at Lawrence Livermore National Laboratory is the largest such laser facility. We have made improvements to the Nova amplifier system that permit increased power and energy output. We summarize the nonlinear effects that now limit Nova's performance and discuss power and energy produced at 1.05-, 0.53-, and 0.35-microm wavelengths, including the results with pulses temporally shaped to improve inertial confinement fusion target performance.

14.
Appl Opt ; 31(30): 6414-26, 1992 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-20733856

RESUMO

To provide high-energy, high-power beams at short wavelengths for inertial-confinement fusion experiments, we routinely convert the 1.05-microm output of the Nova, Nd:phosphate-glass, laser system to its second- or third-harmonic wavelength. We describe the design and performance of the 3 x 3 arrays of potassium dihydrogen phosphate crystal plates used for type-II-type-II phase-matched harmonic conversion of the Nova 0.74-m diameter beams. We also describe an alternate type-I-type-II phasematching configuration that improves third-harmonic conversion efficiency. These arrays provide conversion of a Nova beam of up to 75% to the second harmonic and of up to 70% to the third harmonic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...