1.
Europace ; 24(10): 1627-1635, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35718878

RESUMO

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência Renal Crônica , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Lasers de Excimer , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
2.
Artif Organs ; 45(3): 244-253, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32857884

RESUMO

Postinfarction ventricular septal defect (pVSD) due to acute myocardial infarction complicated by cardiogenic shock (CS) is associated with high mortality. The aim of this study was to determine the outcome of primary surgical repair of pVSD in patients with CS and examine whether it is influenced by the use of mechanical circulatory support (MCS) devices. Between October 1994 and April 2016, primary surgical repair of pVSD complicated by CS was performed in 53 patients. Thirty-six (68%) were implanted pre-operatively with an intra-aortic balloon pump (IABP), 4 (8%) with extracorporeal life support (ECLS), and 13 (24%) received no MCS device. Prospectively collected demographic and perioperative data were analyzed retrospectively. All-cause, 30-day mortality rates were analyzed and multivariate analysis was performed to differentiate independent risk factors. No pre-operatively implanted MCS device was able to improve 30-day survival, whereas pre-operatively implanted ECLS tended to have a positive effect (P = .106). The post-operative need for a MCS device or escalation of MCS invasiveness (IABP upgrade to ECLS) was associated with a higher 30-day mortality (P = .001) compared with patients without any MCS device or those with pre-operatively implanted MCS devices. An independent risk factor for 30-day mortality was the interval between acute myocardial infarction and surgery <7 days (OR 5.895, CI 1.615-21.515; P = .007). Pre-operative implantation of ECLS for CS tends to improve the outcome of early primary surgical pVSD repair. The need for a post-operative MCS device is associated with a worse 30-day survival after early primary surgical pVSD repair.


Assuntos
Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Comunicação Interventricular/cirurgia , Balão Intra-Aórtico/estatística & dados numéricos , Infarto do Miocárdio/terapia , Choque Cardiogênico/terapia , Idoso , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Comunicação Interventricular/etiologia , Comunicação Interventricular/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento
3.
Eur J Cardiothorac Surg ; 55(6): 1234-1235, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30351411

RESUMO

The spectrum of cardiac injury due to blunt chest trauma may range from cardiac contusions with a clinically silent course to fatal cardiac wall rupture. Pulmonary valve insufficiency due to non-penetrating chest trauma is a rare entity. In this case, pulmonary valve insufficiency as a result of valve tear due to high-velocity blunt chest trauma required surgical replacement.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/etiologia , Traumatismos Torácicos/complicações , Ferimentos não Penetrantes/complicações , Adulto , Ecocardiografia , Humanos , Masculino , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/cirurgia , Traumatismos Torácicos/diagnóstico , Ferimentos não Penetrantes/diagnóstico
5.
J Magn Reson Imaging ; 45(2): 535-541, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27459111

RESUMO

PURPOSE: To determine the impact of myocardial iron overload on left atrial (LA) volume and function using MR in patients with systemic iron overload. MATERIALS AND METHODS: Thirty-eight patients with systemic iron overload disease and 10 controls underwent 1.5 Tesla MR performing steady state free precession short-axis cine-series of the LA. Three-dimensional-volumetry was assessed to calculate LA volumes and function. Parameters were indexed (i) to body surface area. The myocardial transverse relaxation rate R2* was determined in the ventricular septum using a multi-echo GRE sequence (breathhold; electrocardiography triggered; 12 echoes; echo time = 1.3-25.7 ms). RESULTS: Significantly decreased active atrial emptying fraction (AAEF) (23% [95%-range, 7-34] versus 36% [95%-range, 14-49], P = 0.009), active atrial emptying volume (AAEVi) (5.5 mL/m2 [95%-range, 2-11] versus 11.9 mL/m2 [95%-range, 3-23], P = 0.008), and active peak emptying rate (APERi) (46 mL/s/m2 [95%-range, 29-69] versus 75 mL/s/m2 [95%-range, 45-178], P < 0.001) were found for patients with myocardial iron overload (R2* > 40 s-1 ) compared with patients with normal myocardial iron levels (R2* < 40 s-1 ). Receiver operating characteristics (ROC) analysis revealed higher potential to indicate myocardial iron overload for the AAEF (area under the ROC curve [AUC] = 0.84; P < 0.0001), APERi (AUC = 0.87; P < 0.0001), and AAEVi (AUC = 0.80; P < 0.0001) compared with LA ejection fraction (LAEF) (AUC = 0.68; P = 0.02) with equal sensitivities and specificities of 82% (AAEF), 79% (APERi), 73% (AAEVi), and 57% (LAEF). CONCLUSION: MR parameters of active LA contractile function were associated with myocardial iron overload. This cross-sectional study suggests impaired active LA contractile function to be sensitive to myocardial iron toxicity. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:535-541.


Assuntos
Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Sobrecarga de Ferro/diagnóstico por imagem , Sobrecarga de Ferro/fisiopatologia , Ferro/metabolismo , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Adolescente , Adulto , Idoso , Técnicas de Imagem Cardíaca/métodos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS