Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 274: 114168, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38944190

RESUMO

To evaluate the utilization of the American Academy of Pediatrics' (AAP) cardiovascular screening questions within preparticipation physical evaluation forms from the 50 state high school athletic associations. We found that fewer than one-half of state forms incorporated all 10 AAP questions; moreover, a subset failed to adhere to criteria recommended by either the AAP or American Heart Association.

2.
J Interv Card Electrophysiol ; 66(3): 611-619, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36104612

RESUMO

BACKGROUND: The Advisor™ HD Grid mapping catheter (Abbott Laboratories; Chicago, IL) allows for bipolar electrogram collection in both orthogonal and perpendicular planes, unique when compared to traditional and branch catheters. Experience in pediatric patients and congenital heart disease (CHD) is limited. The purpose of this work was to evaluate the utility and safety of the Advisor™ HD Grid mapping catheter in pediatric and CHD populations. METHODS: Retrospective review of all pediatric patients and those with CHD (regardless of age) at Children's Hospital Colorado and University of Colorado undergoing electrophysiologic study in which the Advisor™ HD Grid mapping catheter was utilized. RESULTS: Sixty-five procedures in 60 patients (N = 31 female (47.6%), median age 17 years (15-24.1)) were included. Patients had CHD in 30 procedures (46.1%). Eight-eight arrhythmia substrates were mapped including atrial flutter/intra-atrial reentrant tachycardia (N = 33), focal atrial tachycardia (N = 20), isolated PVCs (N = 10), accessory pathways (N = 9), atrioventricular nodal reentrant tachycardia (N = 7), right ventricular substrate mapping (N = 7), and ventricular tachycardia (N = 2). Median time per map was 11.8 (7.5-20.1) min with 3.2 (± 1.7) maps per procedure and a median of 2634 (1767-7654) points used per map. Patients with CHD required more maps (p < 0.001) and points per map (p < 0.001). Ablation was successful in 92.4% of procedures. CONCLUSIONS: The Advisor™ HD Grid mapping catheter is safe and effective in the pediatric and congenital heart disease population. A wide variety of arrhythmia substrates can be mapped with high point density and low mapping time.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Taquicardia Supraventricular , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Criança , Feminino , Adolescente , Resultado do Tratamento , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Taquicardia Supraventricular/cirurgia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Catéteres , Ablação por Cateter/métodos
3.
J Pediatr ; 219: 43-47, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32014282

RESUMO

OBJECTIVE: To determine whether postnatal echocardiographic indices of left ventricular (LV) size and function are associated with atrial-level shunt direction and investigate whether a relationship exists between LV function and LV size in patients with congenital diaphragmatic hernia (CDH). STUDY DESIGN: This was a single-center retrospective study of 51 neonates with CDH evaluated at Children's Hospital Colorado. Initial postnatal echocardiograms were analyzed for cardiac dimensions, valvar integrity, cardiac time intervals, and biventricular function. Comparisons were made between neonates with left-to-right vs right-to-left atrial-level shunting, as well as between those with decreased (ejection fraction <55%) vs normal (ejection fraction ≥55%) LV function. RESULTS: The majority (82.4%) of infants with CDH had a left-to-right atrial-level shunt, and 84.3% had systemic or suprasystemic pulmonary artery pressure. Decreased LV function was demonstrated in 37.2% and was associated with smaller LV volumes and worse outcomes, including the need for extracorporeal membrane oxygenation (ECMO) and survival. CONCLUSIONS: Left-to-right atrial-level shunting is common in neonates with severe CDH, even in the presence of suprasystemic pulmonary artery pressure. LV dysfunction correlates with decreased LV volumes and is associated with adverse neonatal outcomes, including increased need for ECMO and decreased survival.


Assuntos
Átrios do Coração/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/complicações , Hipertensão Pulmonar/fisiopatologia , Ecocardiografia , Feminino , Átrios do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/etiologia , Recém-Nascido , Masculino , Estudos Retrospectivos , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA