Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale ; 10(36): 17053-17059, 2018 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-29869667

RESUMO

The transformation optics (TO) technique, which establishes an equivalence between a curved space and a spatial distribution of inhomogeneous constitutive parameters, has enabled an extraordinary paradigm for manipulating wave propagation. However, extreme constitutive parameters, as well as a static nature, inherently limit the simultaneous achievement of broadband performance, ultrafast reconfigurability and versatile reprogrammable functions. Here, we integrate the TO technique with an active phase-change chalcogenide to achieve a reconfigurable multi-mode guided-wave lens. The lens is made of a Rinehart-shaped curved waveguide with an effective refractive index gradient profile through partially crystallizing Ge2Sb2Te5. Upon changing the bias time of the external voltage imparted to the Ge2Sb2Te5 segments, the refractive index gradient profile can be tuned with a transformative platform for various functions for visible light. The electrically reprogrammable multi-mode guided-wave lens is capable of dynamically acquiring various functionalities with an ultrafast response time. Our findings may offer a significant step forward by providing a universal method to obtain ultrafast and highly versatile guided-wave manipulation, such as in Einstein rings, cloaking, Maxwell fish-eye lenses and Luneburg lenses.

2.
Opt Express ; 25(9): 9911-9925, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28468371

RESUMO

We numerically demonstrate a multiband circular dichroism (CD) by tilting achiral metamaterials (MMs) composed of an elliptical nanoholes array (ENA) penetrating through metal/ phase-change material (PCM) /metal multilayer stack, with respect to the incident light. The CD spectrum can be actively tuned across a wide range from the near-infrared (NIR) to mid-infrared (MIR) regime by transiting the state of the PCM (Ge2Sb2Te5) from amorphous to crystalline. Thus, it can switch on/off a multiband chiroptical response in the infrared region. Our simulation also elucidates that the achiral multilayer stack MMs, which have strong magnetic resonances, can enhance the optical chirality inside the elliptical apertures for both amorphous and crystalline states. The switching of the enhanced chirality may pave the way to manipulate electromagnetic waves, such as tunable circular polarizers, chiroptical spectroscopy, and chiral biosensors.

3.
Artigo em Inglês | MEDLINE | ID: mdl-26415130

RESUMO

We recently built a fiber-optic laser-ultrasound (LU) scanner for nondestructive evaluation (NDE) of aircraft composites and demonstrated its greatly improved sensitivity and stability compared with current noncontact systems. It is also very attractive in terms of cost, stability to environmental noise and surface roughness, simplicity in adjustment, footprint, and flexibility. A new type of a balanced fiber-optic Sagnac interferometer is a key component of this all-optical LU pump-probe system. Very high A-scan rates can be achieved because no reference arm or stabilization feedback are needed. Here, we demonstrate LU system performance at 1000 A-scans/s combined with a fast 2-D translator operating at a scanning speed of 100 mm/s with a peak acceleration of 10 m/s(2) in both lateral directions to produce parallel B-scans at high rates. The fast scanning strategy is described in detail. The sensitivity of this system, in terms of noise equivalent pressure, was further improved to be only 8.3 dB above the Nyquist thermal noise limit. To our knowledge, this is the best reported sensitivity for a noncontact ultrasonic detector of this dimension used to inspect aircraft composites.


Assuntos
Ultrassom/instrumentação , Aeronaves , Materiais de Construção , Desenho de Equipamento , Tecnologia de Fibra Óptica , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Opt Express ; 23(14): 18620-9, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26191920

RESUMO

Tuning the chiroptical response of a molecule is crucial for detecting the material's chirality. Here, we demonstrate a pronounced circular conversion dichroism (CCD) by using an achiral metasurface (AMS) which is composed of a rectangular reflectarray of Au squares separated from a continuous Au film by a dielectric interlayer. This extrinsically 2D chirality originates from the mutual orientation between the AMS and oblique incident wave. The AMS is further incorporated with graphene to tune the CCD spectra in the mid-infrared (MIR) region by electrically modulating the graphene's Fermi level. This approach offers a high fabrication tolerance and will be a promising candidate for controlling electromagnetic (EM) waves in the MIR region from 1500 to 3000 nm.

5.
Photoacoustics ; 3(1): 3-10, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25893169

RESUMO

Integrating high contrast bubbles from ultrasound imaging with plasmonic absorbers from photoacoustic imaging is investigated. Nanoemulsion beads coated with gold nanopsheres (NEB-GNS) are excited with simultaneous light (transient heat at the GNS's) and ultrasound (rarefactional pressure) resulting in a phase transition achievable under different scenarios, enhancing laser-induced acoustic signals and enabling specific detection of nanoprobes at lower concentration. An automated platform allowed dual parameter scans of both pressure and laser fluence while recording broadband acoustic signals. Two types of NEB-GNS and individual GNS were investigated and showed the great potential of this technique to enhance photoacoustic/acoustic signals. The NEB-GNS size distribution influences vaporization thresholds which can be reached at both permissible ultrasound and light exposures at deep penetration and at low concentrations of targets. This technique, called sono-photoacoustics, has great potential for targeted molecular imaging and therapy using compact nanoprobes with potentially high-penetrability into tissue.

6.
Photoacoustics ; 3(1): 11-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25893170

RESUMO

Photoacoustic (PA) imaging using exogenous agents can be limited by degraded specificity due to strong background signals. This paper introduces a technique called sono-photoacoustics (SPA) applied to perfluorohexane nanodroplets coated with gold nanospheres. Pulsed laser and ultrasound (US) excitations are applied simultaneously to the contrast agent to induce a phase-transition ultimately creating a transient microbubble. The US field present during the phase transition combined with the large thermal expansion of the bubble leads to 20-30 dB signal enhancement. Aqueous solutions and phantoms with very low concentrations of this agent were probed using pulsed laser radiation at diagnostic exposures and a conventional US array used both for excitation and imaging. Contrast specificity of the agent was demonstrated with a coherent differential scheme to suppress US and linear PA background signals. SPA shows great potential for molecular imaging with ultrasensitive detection of targeted gold coated nanoemulsions and cavitation-assisted theranostic approaches.

7.
ACS Nano ; 9(2): 1964-76, 2015 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-25658655

RESUMO

Photoacoustic imaging has emerged as a highly promising tool to visualize molecular events with deep tissue penetration. Like most other modalities, however, image contrast under in vivo conditions is far from optimal due to background signals from tissue. Using iron oxide-gold core-shell nanoparticles, we have previously demonstrated the concept of magnetomotive photoacoustic (mmPA) imaging, which is capable of dramatically reducing the influence of background signals and producing high-contrast molecular images. Here, we report two significant advances toward clinical translation of this technology. First, we introduce a new class of compact, uniform, magneto-optically coupled core-shell nanoparticles, prepared through localized copolymerization of polypyrrole (PPy) on an iron oxide nanoparticle surface. The resulting iron oxide-PPy nanoparticles feature high colloidal stability and solve the photoinstability and small-scale synthesis problems previously encountered by the gold coating approach. In parallel, we have developed a new generation of mmPA featuring cyclic magnetic motion and ultrasound speckle tracking (USST), whose imaging capture frame rate is several hundred times faster than the photoacoustic speckle tracking (PAST) method we demonstrated previously. These advances enable robust artifact elimination caused by physiologic motions and demonstrate the application of the mmPA technology for in vivo sensitive tumor imaging.


Assuntos
Meios de Contraste/química , Compostos Férricos/química , Fenômenos Magnéticos , Fenômenos Ópticos , Técnicas Fotoacústicas/métodos , Animais , Meios de Contraste/toxicidade , Feminino , Compostos Férricos/toxicidade , Ouro/química , Células HeLa , Humanos , Camundongos , Polimerização , Polímeros/química , Pirróis/química
8.
Artigo em Inglês | MEDLINE | ID: mdl-25643081

RESUMO

Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme.


Assuntos
Técnicas Fotoacústicas/métodos , Ultrassonografia de Intervenção/métodos , Animais , Galinhas , Humanos , Músculo Esquelético/diagnóstico por imagem , Imagens de Fantasmas , Técnicas Fotoacústicas/instrumentação , Ultrassonografia de Intervenção/instrumentação
9.
IEEE Int Ultrason Symp ; 20152015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35432748

RESUMO

To integrate real-time photoacoustics (PA) into ultrasound (US) scanners and accelerate clinical translation of combined PAUS imaging, we previously developed a system using a portable, low-cost, low pulse energy, high-repetition rate laser (~1kHz) with a 1D galvo-mirror for rapid laser beam scanning over the imaging area. However, the frame rate and pulse energy are limited because of regulations on the radiance (1 W/cm2). Therefore, a laser scan scheme needs to be optimized to provide high frame rate within this safety limit. In addition, the laser light should be evenly distributed to minimize any artifacts caused by the scanning approach. In this paper, we calculated the laser light distribution using 3D Monte Carlo simulation and further developed the system to scan the laser beam in elevation as well as laterally using a 2-dimensional galvo-mirror scanner to achieve higher frame rates within the radiance safety limit. Insertion of a needle into chicken breast tissue was used to demonstrate our optimized scan scheme.

10.
Artigo em Inglês | MEDLINE | ID: mdl-36247362

RESUMO

Ultrasound-guided photoacoustic imaging has shown great potential for many clinical applications including vascular visualization, detection of nanoprobes sensing molecular profiles, and guidance of interventional procedures. However, bulky and costly lasers are usually required to provide sufficient pulse energies for deep imaging. The low pulse repetition rate also limits potential real-time applications of integrated photoacoustic/ultrasound (PAUS) imaging. With a compact and low-cost laser operating at a kHz repetition rate, we aim to integrate photoacoustics (PA) into a commercial ultrasound (US) machine utilizing an interleaved scanning approach for clinical translation, with imaging depth up to a few centimeters and frame rates > 30 Hz. Multiple PA sub-frames are formed by scanning laser firings covering a large scan region with a rotating galvo mirror, and then combined into a final frame. Ultrasound pulse-echo beams are interleaved between laser firings/PA receives. The approach was implemented with a diode-pumped laser, a commercial US scanner, and a linear array transducer. Insertion of an 18-gauge needle into a piece of chicken tissue, with subsequent injection of an absorptive agent into the tissue, was imaged with an integrated PAUS frame rate of 30 Hz, covering a 2.8 cm × 2.8 cm imaging plane. Given this real-time image rate and high contrast (> 40 dB at more than 1-cm depth in the PA image), we have demonstrated that this approach is potentially attractive for clinical procedure guidance.

11.
Artigo em Inglês | MEDLINE | ID: mdl-36275045

RESUMO

Magnetomotive photoacoustic/ultrasound imaging has shown superior specificity in visualizing targeted objects at cellular and molecular levels. By detecting magnet-induced displacements, magnetic-particle-targeted objects can be differentiated from background signals insensitive to the magnetic field. Unfortunately, background physiologic motion interferes during measurement, such as cardiac-induced motion and respiration, greatly reducing the robustness of the technique. In this paper, we propose cyclic magnetomotive imaging with narrowband magnetic excitation. By synchronizing magnetic motion with the excitations, targeted objects moving coherently can be distinguished from background static signals and signals moving incoherently. HeLa cells targeted with magnetic nanoparticle-polymer core-shell particles were used as the targets for an initial test. A linear ultrasound array was interfaced with a commercial scanner to acquire a photoacoustic/ultrasound image sequence (maximum 1000 frames per second) during multi-cycle magnetic excitation (0.5 - 40 Hz frequency range) with an electromagnet. An image mask defined by a threshold on the displacement-coherence map was applied to the original images for background suppression. The results show that contrast was increased by more than 60 dB in an in-vitro experiment with the tagged cells fixed in a polyvinyl-alcohol gel and sandwiched between porcine liver tissues. Using a single sided system, cells injected subcutaneously on the back of a mouse were successfully differentiated from the background, with less than 20 µm coherent magnetic induced displacements isolated from millimetric background breathing motion. These results demonstrate the technique's motion robustness for highly sensitive and specific diagnosis.

12.
Photoacoustics ; 2(2): 63-74, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25302156

RESUMO

Laser-ultrasonics is an attractive and powerful tool for the non-destructive testing and evaluation (NDT&E) of composite materials. Current systems for non-contact detection of ultrasound have relatively low sensitivity compared to contact peizotransducers. They are also expensive, difficult to adjust, and strongly influenced by environmental noise. Moreover, laser-ultrasound (LU) systems typically launch only about 50 firings per second, much slower than the kHz level pulse repetition rate of conventional systems. As demonstrated here, most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive, high repetition rate nanosecond fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe beam detector. In particular, a modified fiber-optic balanced Sagnac interferometer is presented as part of a LU pump-probe system for NDT&E of aircraft composites. The performance of the all-optical system is demonstrated for a number of composite samples with different types and locations of inclusions.

13.
Opt Lett ; 39(9): 2599-602, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24784055

RESUMO

Optically activated cavitation in a nanoemulsion contrast agent is proposed for therapeutic applications. With a 56°C boiling point perfluorohexane core and highly absorptive gold nanospheres at the oil-water interface, cavitation nuclei in the core can be efficiently induced with a laser fluence below medical safety limits (70 mJ/cm2 at 1064 nm). This agent is also sensitive to ultrasound (US) exposure and can induce inertial cavitation at a pressure within the medical diagnostic range. Images from a high-speed camera demonstrate bubble formation in these nanoemulsions. The potential of using this contrast agent for blood clot disruption is demonstrated in an in vitro study. The possibility of simultaneous laser and US excitation to reduce the cavitation threshold for therapeutic applications is also discussed.


Assuntos
Coagulação Sanguínea/fisiologia , Coagulação Sanguínea/efeitos da radiação , Gases/efeitos da radiação , Ouro/efeitos da radiação , Terapia a Laser/métodos , Trombólise Mecânica/métodos , Nanosferas/efeitos da radiação , Relação Dose-Resposta à Radiação , Emulsões , Ouro/uso terapêutico , Humanos , Nanosferas/uso terapêutico , Doses de Radiação
14.
J Appl Phys ; 115(11): 113105, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24737921

RESUMO

Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer.

15.
Appl Phys Lett ; 104(3): 033701, 2014 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-24753620

RESUMO

A composite contrast agent, a nanoemulsion bead with assembled gold nanospheres at the interface, is proposed to improve the specific contrast of photoacoustic molecular imaging. A phase transition in the bead's core is induced by absorption of a nanosecond laser pulse with a fairly low laser fluence (∼3.5 mJ/cm2), creating a transient microbubble through dramatically enhanced thermal expansion. This generates nonlinear photoacoustic signals with more than 10 times larger amplitude compared to that of a linear agent with the same optical absorption. By applying a differential scheme similar to ultrasound pulse inversion, more than 40 dB contrast enhancement is demonstrated with suppression of background signals.

16.
Sci Rep ; 4: 3955, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24492415

RESUMO

We report a broadband polarization-independent perfect absorber with wide-angle near unity absorbance in the visible regime. Our structure is composed of an array of thin Au squares separated from a continuous Au film by a phase change material (Ge2Sb2Te5) layer. It shows that the near perfect absorbance is flat and broad over a wide-angle incidence up to 80° for either transverse electric or magnetic polarization due to a high imaginary part of the dielectric permittivity of Ge2Sb2Te5. The electric field, magnetic field and current distributions in the absorber are investigated to explain the physical origin of the absorbance. Moreover, we carried out numerical simulations to investigate the temporal variation of temperature in the Ge2Sb2Te5 layer and to show that the temperature of amorphous Ge2Sb2Te5 can be raised from room temperature to > 433 K (amorphous-to-crystalline phase transition temperature) in just 0.37 ns with a low light intensity of 95 nW/µm(2), owing to the enhanced broadband light absorbance through strong plasmonic resonances in the absorber. The proposed phase-change metamaterial provides a simple way to realize a broadband perfect absorber in the visible and near-infrared (NIR) regions and is important for a number of applications including thermally controlled photonic devices, solar energy conversion and optical data storage.

17.
Ann Biomed Eng ; 41(11): 2237-47, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23982280

RESUMO

The advantages of photoacoustic (PA) imaging, including low cost, non-ionizing operation, and sub-mm spatial resolution at centimeters depth, make it a promising modality to probe nanoparticle-targeted abnormalities in real time at cellular and molecular levels. However, detecting rare cell types in a heterogeneous background with strong optical scattering and absorption remains a big challenge. For example, differentiating circulating tumor cells in vivo (typically fewer than 10 cells/mL for an active tumor) among billions of erythrocytes in the blood is nearly impossible. In this paper, a newly developed technique, magnetomotive photoacoustic (mmPA) imaging, which can greatly increase the sensitivity and specificity of sensing targeted cells or molecular interactions, is reviewed. Its primary advantage is suppression of background signals through magnetic enrichment/manipulation with simultaneous PA detection of magnetic contrast agent targeted objects. Results from phantom and in vitro studies demonstrate the capability of mmPA imaging to differentiate regions targeted with magnetic nanoparticles from the background, and to trap and sensitively detect targeted cells at a concentration of a single cell per milliliter in a flow system mimicking a human peripheral artery. This technique provides an example of the ways in which molecular imaging can potentially enable robust molecular diagnosis and treatment, and accelerate the translation of molecular medicine into the clinic.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Neoplasias/patologia , Células Neoplásicas Circulantes/patologia , Técnicas Fotoacústicas/métodos , Humanos , Sensibilidade e Especificidade
18.
Phys Chem Chem Phys ; 15(40): 17006-15, 2013 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-23860904

RESUMO

In recent years, conjugated polymers have attracted considerable attention from the imaging community as a new class of contrast agent due to their intriguing structural, chemical, and optical properties. Their size and emission wavelength tunability, brightness, photostability, and low toxicity have been demonstrated in a wide range of in vitro sensing and cellular imaging applications, and have just begun to show impact in in vivo settings. In this Perspective, we summarize recent advances in engineering conjugated polymers as imaging contrast agents, their emerging applications in molecular imaging (referred to as in vivo uses in this paper), as well as our perspectives on future research.


Assuntos
Imagem Molecular , Polímeros/química , Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste/química , Humanos , Linfonodos/patologia , Imagem Molecular/tendências , Estrutura Molecular , Nanopartículas/química , Radiografia
19.
J Biophotonics ; 6(6-7): 513-22, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23420803

RESUMO

Photoacoustic (PA) imaging has been demonstrated to be a promising modality in molecular imaging for detection of nanoparticle-targeted diseased cells or tissues. However, intrinsic absorbers, such as blood, produce strong PA background signals that severely degrade the detection sensitivity and specificity of targeted objects. Magnetomotive photoacoustic (mmPA) imaging, a newly developed molecular imaging modality, introduced dynamic manipulation into traditional PA imaging. Unlike conventional PA imaging, magnetomotive manipulation with simultaneous ultrasound/PA imaging of agents incorporating magnetic nanoparticles enables direct visualization of the signal generating object and can dramatically reduce background signals from strong optical absorbers. This paper briefly reviews recent developments in mmPA imaging, including uses of composite contrast agent, design of magnet system, and data processing for motion filtering. The use of mmPA imaging in detecting rare circulating tumor cells in blood vessels, which remains a big challenge for real-time in vivo examination using current methodologies, was also addressed.


Assuntos
Separação Celular/métodos , Fenômenos Magnéticos , Imagem Molecular/métodos , Células Neoplásicas Circulantes/patologia , Técnicas Fotoacústicas/métodos , Meios de Contraste , Células HeLa , Humanos , Microesferas , Poliestirenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...