Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39263747

RESUMO

Neuron-specific enolase (NSE), a tumor marker of small cell lung cancer (SCLC), has high application value in the early diagnosis of SCLC. In this study, a dual signal electrochemical aptasensor for NSE was constructed based on hemin/reduced graphene oxide/multi-walled carbon nanotube (H-rGO-MWCNT) nanocomposites. Hemin played a dual role, functioning not only as an in situ electrochemical probe but also exhibiting excellent peroxidase-like properties, effectively catalyzing the electroreduction of H2O2. Reduced graphene oxide and multi-walled carbon nanotubes exhibited excellent conductivity. Through their binding with hemin, the nanocomposites achieved a larger specific surface area, providing numerous active sites for capturing the NSE aptamer. In the presence of NSE, the specific adsorption between the antigen and the aptamer formed a stable antigen-aptamer structure, which inhibited the performance of hemin, resulting in the weakening of the electrochemical signals of hemin and H2O2. Leveraging these characteristics, the sensitive and cost-effective dual-signal electrochemical aptasensor has been fabricated for the detection of NSE. One signal corresponded to differential pulse voltammetry (DPV) of hemin, while the other signal was derived from chronoamperometry, capturing the catalytic reduction of H2O2. The linear ranges for NSE were 1 pg mL-1 to 1 µg mL-1 and 100 pg mL-1 to 100 ng mL-1 with the limit of detection (LOD) of 0.21 pg mL-1 and 11.22 pg mL-1 by DPV and chronoamperometry, respectively. In addition, this aptasensor exhibited good reproducibility, stability and specificity. The recovery of NSE in human blood serum samples was from 89% to 131%. It provided a promising strategy for the detection of NSE in clinical diagnostics.

2.
Talanta ; 274: 125965, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38552480

RESUMO

In this paper, a few-layer WS2 nanosheets-based electrochemical biosensor was fabricated for the highly sensitive detection of breast cancer tumor marker miRNA-4484. Firstly, few-layer WS2 nanosheets were prepared by shear stripping and characterized by SEM, TEM, AFM and UV spectrophotometer. After modification of few-layer WS2 nanosheets on the electrode surface, the miRNA probe was fixed on the few-layer WS2 nanosheets by polycytosine (PolyC). Then short-chain miRNA containing PolyC was used as the blocking agent to close the excess active sites on the surface of WS2 nanosheets to complete the fabrication of the sensor biosensing interface. Finally, the current changes caused by the specific binding of miRNA-4484 to the probe were analyzed by differential pulse voltammetry (DPV). The results showed that the sensor had a good linear relationship for the detection of miRNA-4484 in the concentration range of 1 aM-100 fM, and the detection limit was as low as 1.61 aM. In addition, the electrochemical sensor had excellent selectivity, stability and reproducibility. The artificial sample tests indicated that the developed biosensors have the potential for clinical application in the future.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Técnicas Eletroquímicas , MicroRNAs , Nanoestruturas , Sulfetos , Compostos de Tungstênio , Técnicas Biossensoriais/métodos , MicroRNAs/análise , Biomarcadores Tumorais/análise , Técnicas Eletroquímicas/métodos , Humanos , Sulfetos/química , Nanoestruturas/química , Compostos de Tungstênio/química , Limite de Detecção , Eletrodos , Neoplasias da Mama/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA