Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Acad Radiol ; 30(10): 2269-2279, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37210268

RESUMO

RATIONALE AND OBJECTIVES: Finding comparison to relevant prior studies is a requisite component of the radiology workflow. The purpose of this study was to evaluate the impact of a deep learning tool simplifying this time-consuming task by automatically identifying and displaying the finding in relevant prior studies. MATERIALS AND METHODS: The algorithm pipeline used in this retrospective study, TimeLens (TL), is based on natural language processing and descriptor-based image-matching algorithms. The dataset used for testing comprised 3872 series of 246 radiology examinations from 75 patients (189 CTs, 95 MRIs). To ensure a comprehensive testing, five finding types frequently encountered in radiology practice were included: aortic aneurysm, intracranial aneurysm, kidney lesion, meningioma, and pulmonary nodule. After a standardized training session, nine radiologists from three university hospitals performed two reading sessions on a cloud-based evaluation platform resembling a standard RIS/PACS. The task was to measure the diameter of the finding-of-interest on two or more exams (a most recent and at least one prior exam): first without use of TL, and a second session at an interval of at least 21 days with the use of TL. All user actions were logged for each round, including time needed to measure the finding at all timepoints, number of mouse clicks, and mouse distance traveled. The effect of TL was evaluated in total, per finding type, per reader, per experience (resident vs. board-certified radiologist), and per modality. Mouse movement patterns were analyzed with heatmaps. To assess the effect of habituation to the cases, a third round of readings was performed without TL. RESULTS: Across scenarios, TL reduced the average time needed to assess a finding at all timepoints by 40.1% (107 vs. 65 seconds; p < 0.001). Largest accelerations were demonstrated for assessment of pulmonary nodules (-47.0%; p < 0.001). Less mouse clicks (-17.2%) were needed for finding evaluation with TL, and mouse distance traveled was reduced by 38.0%. Time needed to assess the findings increased from round 2 to round 3 (+27.6%; p < 0.001). Readers were able to measure a given finding in 94.4% of cases on the series initially proposed by TL as most relevant series for comparison. The heatmaps showed consistently simplified mouse movement patterns with TL. CONCLUSION: A deep learning tool significantly reduced both the amount of user interactions with the radiology image viewer and the time needed to assess findings of interest on cross-sectional imaging with relevant prior exams.


Assuntos
Aprendizado Profundo , Humanos , Estudos Retrospectivos , Radiologistas , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
2.
Eur Radiol ; 33(7): 4589-4596, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36856841

RESUMO

OBJECTIVES: High breast density is a well-known risk factor for breast cancer. This study aimed to develop and adapt two (MLO, CC) deep convolutional neural networks (DCNN) for automatic breast density classification on synthetic 2D tomosynthesis reconstructions. METHODS: In total, 4605 synthetic 2D images (1665 patients, age: 57 ± 37 years) were labeled according to the ACR (American College of Radiology) density (A-D). Two DCNNs with 11 convolutional layers and 3 fully connected layers each, were trained with 70% of the data, whereas 20% was used for validation. The remaining 10% were used as a separate test dataset with 460 images (380 patients). All mammograms in the test dataset were read blinded by two radiologists (reader 1 with two and reader 2 with 11 years of dedicated mammographic experience in breast imaging), and the consensus was formed as the reference standard. The inter- and intra-reader reliabilities were assessed by calculating Cohen's kappa coefficients, and diagnostic accuracy measures of automated classification were evaluated. RESULTS: The two models for MLO and CC projections had a mean sensitivity of 80.4% (95%-CI 72.2-86.9), a specificity of 89.3% (95%-CI 85.4-92.3), and an accuracy of 89.6% (95%-CI 88.1-90.9) in the differentiation between ACR A/B and ACR C/D. DCNN versus human and inter-reader agreement were both "substantial" (Cohen's kappa: 0.61 versus 0.63). CONCLUSION: The DCNN allows accurate, standardized, and observer-independent classification of breast density based on the ACR BI-RADS system. KEY POINTS: • A DCNN performs on par with human experts in breast density assessment for synthetic 2D tomosynthesis reconstructions. • The proposed technique may be useful for accurate, standardized, and observer-independent breast density evaluation of tomosynthesis.


Assuntos
Densidade da Mama , Neoplasias da Mama , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Variações Dependentes do Observador , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Redes Neurais de Computação
3.
Eur Radiol Exp ; 7(1): 5, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36750494

RESUMO

BACKGROUND: To investigate hip implant-related metal artifacts on a 0.55-T system compared with 1.5-T and 3-T systems. METHODS: Total hip arthroplasty made of three different alloys were evaluated in a water phantom at 0.55, 1.5, and 3 T using routine protocols. Visually assessment (VA) was performed by three readers using a Likert scale from 0 (no artifacts) to 6 (extremely severe artifacts). Quantitative assessment (QA) was performed using the coefficient of variation (CoV) and the fraction of voxels within a threshold of the mean signal intensity compared to an automatically defined region of interest (FVwT). Agreement was evaluated using intra/inter-class correlation coefficient (ICC). RESULTS: Interreader agreement of VA was strong-to-moderate (ICC 0.74-0.82). At all field strengths (0.55-T/1.5-T/3-T), artifacts were assigned a lower score for titanium (Ti) alloys (2.44/2.9/2.7) than for stainless steel (Fe-Cr) (4.1/3.9/5.1) and cobalt-chromium (Co-Cr) alloys (4.1/4.1/5.2) (p < 0.001 for both). Artifacts were lower for 0.55-T and 1.5-T than for 3-T systems, for all implants (p ≤ 0.049). A strong VA-to-QA correlation was found (r = 0.81; p < 0.001); CoV was lower for Ti alloys than for Fe-Cr and Co-Cr alloys at all field strengths. The FVwT showed a negative correlation with VA (-0.68 < r < -0.84; p < 0.001). CONCLUSIONS: Artifact intensity was lowest for Ti alloys at 0.55 T. For other alloys, it was similar at 0.55 T and 1.5 T, higher at 3 T. Despite an inferior gradient system and a larger bore width, the 0.55-T system showed the same artifact intensity of the 1.5-T system.


Assuntos
Ligas , Metais , Titânio , Próteses e Implantes , Imageamento por Ressonância Magnética/métodos
6.
Eur Radiol ; 33(2): 1088-1101, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36194266

RESUMO

The European Society of Cardiovascular Radiology (ESCR) is the European specialist society of cardiac and vascular imaging. This society's highest priority is the continuous improvement, development, and standardization of education, training, and best medical practice, based on experience and evidence. The present intra-society consensus is based on the existing scientific evidence and on the individual experience of the members of the ESCR writing group on carotid diseases, the members of the ESCR guidelines committee, and the members of the executive committee of the ESCR. The recommendations published herein reflect the evidence-based society opinion of ESCR. The purpose of this second document is to discuss suggestions for standardized reporting based on the accompanying consensus document part I. KEY POINTS: • CT and MR imaging-based evaluation of carotid artery disease provides essential information for risk stratification and prediction of stroke. • The information in the report must cover vessel morphology, description of stenosis, and plaque imaging features. • A structured approach to reporting ensures that all essential information is delivered in a standardized and consistent way to the referring clinician.


Assuntos
Doenças das Artérias Carótidas , Radiologia , Humanos , Consenso , Imageamento por Ressonância Magnética/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
7.
Eur Radiol ; 33(2): 1063-1087, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36194267

RESUMO

The European Society of Cardiovascular Radiology (ESCR) is the European specialist society of cardiac and vascular imaging. This society's highest priority is the continuous improvement, development, and standardization of education, training, and best medical practice, based on experience and evidence. The present intra-society consensus is based on the existing scientific evidence and on the individual experience of the members of the ESCR writing group on carotid diseases, the members of the ESCR guidelines committee, and the members of the executive committee of the ESCR. The recommendations published herein reflect the evidence-based society opinion of ESCR. We have produced a twin-papers consensus, indicated through the documents as respectively "Part I" and "Part II." The first document (Part I) begins with a discussion of features, role, indications, and evidence for CT and MR imaging-based diagnosis of carotid artery disease for risk stratification and prediction of stroke (Section I). It then provides an extensive overview and insight into imaging-derived biomarkers and their potential use in risk stratification (Section II). Finally, detailed recommendations about optimized imaging technique and imaging strategies are summarized (Section III). The second part of this consensus paper (Part II) is focused on structured reporting of carotid imaging studies with CT/MR. KEY POINTS: • CT and MR imaging-based evaluation of carotid artery disease provides essential information for risk stratification and prediction of stroke. • Imaging-derived biomarkers and their potential use in risk stratification are evolving; their correct interpretation and use in clinical practice must be well-understood. • A correct imaging strategy and scan protocol will produce the best possible results for disease evaluation.


Assuntos
Aterosclerose , Doenças das Artérias Carótidas , Radiologia , Acidente Vascular Cerebral , Humanos , Consenso , Tomografia Computadorizada por Raios X/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Padrões de Referência
8.
JMIR Med Inform ; 10(12): e40534, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36542426

RESUMO

BACKGROUND: A concise visualization framework of related reports would increase readability and improve patient management. To this end, temporal referrals to prior comparative exams are an essential connection to previous exams in written reports. Due to unstructured narrative texts' variable structure and content, their extraction is hampered by poor computer readability. Natural language processing (NLP) permits the extraction of structured information from unstructured texts automatically and can serve as an essential input for such a novel visualization framework. OBJECTIVE: This study proposes and evaluates an NLP-based algorithm capable of extracting the temporal referrals in written radiology reports, applies it to all the radiology reports generated for 10 years, introduces a graphical representation of imaging reports, and investigates its benefits for clinical and research purposes. METHODS: In this single-center, university hospital, retrospective study, we developed a convolutional neural network capable of extracting the date of referrals from imaging reports. The model's performance was assessed by calculating precision, recall, and F1-score using an independent test set of 149 reports. Next, the algorithm was applied to our department's radiology reports generated from 2011 to 2021. Finally, the reports and their metadata were represented in a modulable graph. RESULTS: For extracting the date of referrals, the named-entity recognition (NER) model had a high precision of 0.93, a recall of 0.95, and an F1-score of 0.94. A total of 1,684,635 reports were included in the analysis. Temporal reference was mentioned in 53.3% (656,852/1,684,635), explicitly stated as not available in 21.0% (258,386/1,684,635), and omitted in 25.7% (317,059/1,684,635) of the reports. Imaging records can be visualized in a directed and modulable graph, in which the referring links represent the connecting arrows. CONCLUSIONS: Automatically extracting the date of referrals from unstructured radiology reports using deep learning NLP algorithms is feasible. Graphs refined the selection of distinct pathology pathways, facilitated the revelation of missing comparisons, and enabled the query of specific referring exam sequences. Further work is needed to evaluate its benefits in clinics, research, and resource planning.

9.
Eur J Radiol ; 155: 110460, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35963191

RESUMO

PURPOSE: Airway wall thickening is a consequence of chronic inflammatory processes and usually only qualitatively described in CT radiology reports. The purpose of this study is to automatically quantify airway wall thickness in multiple airway generations and assess the diagnostic potential of this parameter in a large cohort of patients with Chronic Obstructive Pulmonary Disease (COPD). MATERIALS AND METHODS: This retrospective, single-center study included a series of unenhanced chest CTs. Inclusion criteria were the mentioning of an explicit COPD GOLD stage in the written radiology report and time period (01/2019-12/2021). A control group included chest CTs with completely unremarkable lungs according to the report. The DICOM images of all cases (axial orientation; slice-thickness: 1 mm; soft-tissue kernel) were processed by an AI algorithm pipeline consisting of (A) a 3D-U-Net for det detection and tracing of the bronchial tree centerlines (B) extraction of image patches perpendicular to the centerlines of the bronchi, and (C) a 2D U-Net for segmentation of airway walls on those patches. The performance of centerline detection and wall segmentation was assessed. The imaging parameter average wall thickness was calculated for bronchus generations 3-8 (AWT3-8) across the lungs. Mean AWT3-8 was compared between five groups (control, COPD Gold I-IV) using non-parametric statistics. Furthermore, the established emphysema score %LAV-950 was calculated and used to classify scans (normal vs. COPD) alone and in combination with AWT3-8. RESULTS: A total of 575 chest CTs were processed. Algorithm performance was very good (airway centerline detection sensitivity: 86.9%; airway wall segmentation Dice score: 0.86). AWT3-8 was statistically significantly greater in COPD patients compared to controls (2.03 vs. 1.87 mm, p < 0.001) and increased with COPD stage. The classifier that combined %LAV-950 and AWT3-8 was superior to the classifier using only %LAV-950 (AUC = 0.92 vs. 0.79). CONCLUSION: Airway wall thickness increases in patients suffering from COPD and is automatically quantifiable. AWT3-8 could become a CT imaging parameter in COPD complementing the established emphysema biomarker %LAV-950. CLINICAL RELEVANCE STATEMENT: Quantitative measurements considering the complete visible bronchial tree instead of qualitative description could enhance radiology reports, allow for precise monitoring of disease progression and diagnosis of early stages of disease.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Pulmão/diagnóstico por imagem , Retina , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
Invest Radiol ; 57(8): 552-559, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35797580

RESUMO

OBJECTIVE: This study trained and evaluated algorithms to detect, segment, and classify simple and complex pleural effusions on computed tomography (CT) scans. MATERIALS AND METHODS: For detection and segmentation, we randomly selected 160 chest CT scans out of all consecutive patients (January 2016-January 2021, n = 2659) with reported pleural effusion. Effusions were manually segmented and a negative cohort of chest CTs from 160 patients without effusions was added. A deep convolutional neural network (nnU-Net) was trained and cross-validated (n = 224; 70%) for segmentation and tested on a separate subset (n = 96; 30%) with the same distribution of reported pleural complexity features as in the training cohort (eg, hyperdense fluid, gas, pleural thickening and loculation). On a separate consecutive cohort with a high prevalence of pleural complexity features (n = 335), a random forest model was implemented for classification of segmented effusions with Hounsfield unit thresholds, density distribution, and radiomics-based features as input. As performance measures, sensitivity, specificity, and area under the curves (AUCs) for detection/classifier evaluation (per-case level) and Dice coefficient and volume analysis for the segmentation task were used. RESULTS: Sensitivity and specificity for detection of effusion were excellent at 0.99 and 0.98, respectively (n = 96; AUC, 0.996, test data). Segmentation was robust (median Dice, 0.89; median absolute volume difference, 13 mL), irrespective of size, complexity, or contrast phase. The sensitivity, specificity, and AUC for classification in simple versus complex effusions were 0.67, 0.75, and 0.77, respectively. CONCLUSION: Using a dataset with different degrees of complexity, a robust model was developed for the detection, segmentation, and classification of effusion subtypes. The algorithms are openly available at https://github.com/usb-radiology/pleuraleffusion.git.


Assuntos
Derrame Pleural , Tomografia Computadorizada por Raios X , Algoritmos , Exsudatos e Transudatos/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Derrame Pleural/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
11.
Diagnostics (Basel) ; 12(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35626201

RESUMO

Pericardial effusions (PEFs) are often missed on Computed Tomography (CT), which particularly affects the outcome of patients presenting with hemodynamic compromise. An automatic PEF detection, segmentation, and classification tool would expedite and improve CT based PEF diagnosis; 258 CTs with (206 with simple PEF, 52 with hemopericardium) and without PEF (each 134 with contrast, 124 non-enhanced) were identified using the radiology report (01/2016−01/2021). PEF were manually 3D-segmented. A deep convolutional neural network (nnU-Net) was trained on 316 cases and separately tested on the remaining 200 and 22 external post-mortem CTs. Inter-reader variability was tested on 40 CTs. PEF classification utilized the median Hounsfield unit from each prediction. The sensitivity and specificity for PEF detection was 97% (95% CI 91.48−99.38%) and 100.00% (95% CI 96.38−100.00%) and 89.74% and 83.61% for diagnosing hemopericardium (AUC 0.944, 95% CI 0.904−0.984). Model performance (Dice coefficient: 0.75 ± 0.01) was non-inferior to inter-reader (0.69 ± 0.02) and was unaffected by contrast administration nor alternative chest pathology (p > 0.05). External dataset testing yielded similar results. Our model reliably detects, segments, and classifies PEF on CT in a complex dataset, potentially serving as an alert tool whilst enhancing report quality. The model and corresponding datasets are publicly available.

12.
Radiol Artif Intell ; 4(2): e210168, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35391777

RESUMO

Authors implemented an artificial intelligence (AI)-based detection tool for intracranial hemorrhage (ICH) on noncontrast CT images into an emergent workflow, evaluated its diagnostic performance, and assessed clinical workflow metrics compared with pre-AI implementation. The finalized radiology report constituted the ground truth for the analysis, and CT examinations (n = 4450) before and after implementation were retrieved using various keywords for ICH. Diagnostic performance was assessed, and mean values with their respective 95% CIs were reported to compare workflow metrics (report turnaround time, communication time of a finding, consultation time of another specialty, and turnaround time in the emergency department). Although practicable diagnostic performance was observed for overall ICH detection with 93.0% diagnostic accuracy, 87.2% sensitivity, and 97.8% negative predictive value, the tool yielded lower detection rates for specific subtypes of ICH (eg, 69.2% [74 of 107] for subdural hemorrhage and 77.4% [24 of 31] for acute subarachnoid hemorrhage). Common false-positive findings included postoperative and postischemic defects (23.6%, 37 of 157), artifacts (19.7%, 31 of 157), and tumors (15.3%, 24 of 157). Although workflow metrics such as communicating a critical finding (70 minutes [95% CI: 54, 85] vs 63 minutes [95% CI: 55, 71]) were on average reduced after implementation, future efforts are necessary to streamline the workflow all along the workflow chain. It is crucial to define a clear framework and recognize limitations as AI tools are only as reliable as the environment in which they are deployed. Keywords: CT, CNS, Stroke, Diagnosis, Classification, Application Domain © RSNA, 2022.

13.
Magn Reson Med ; 88(1): 391-405, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35348244

RESUMO

PURPOSE: To introduce a widely applicable workflow for pulmonary lobe segmentation of MR images using a recurrent neural network (RNN) trained with chest CT datasets. The feasibility is demonstrated for 2D coronal ultrafast balanced SSFP (ufSSFP) MRI. METHODS: Lung lobes of 250 publicly accessible CT datasets of adults were segmented with an open-source CT-specific algorithm. To match 2D ufSSFP MRI data of pediatric patients, both CT data and segmentations were translated into pseudo-MR images that were masked to suppress anatomy outside the lung. Network-1 was trained with pseudo-MR images and lobe segmentations and then applied to 1000 masked ufSSFP images to predict lobe segmentations. These outputs were directly used as targets to train Network-2 and Network-3 with non-masked ufSSFP data as inputs, as well as an additional whole-lung mask as input for Network-2. Network predictions were compared to reference manual lobe segmentations of ufSSFP data in 20 pediatric cystic fibrosis patients. Manual lobe segmentations were performed by splitting available whole-lung segmentations into lobes. RESULTS: Network-1 was able to segment the lobes of ufSSFP images, and Network-2 and Network-3 further increased segmentation accuracy and robustness. The average all-lobe Dice similarity coefficients were 95.0 ± 2.8 (mean ± pooled SD [%]) and 96.4 ± 2.5, 93.0 ± 2.0; and the average median Hausdorff distances were 6.1 ± 0.9 (mean ± SD [mm]), 5.3 ± 1.1, 7.1 ± 1.3 for Network-1, Network-2, and Network-3, respectively. CONCLUSION: Recurrent neural network lung lobe segmentation of 2D ufSSFP imaging is feasible, in good agreement with manual segmentations. The proposed workflow might provide access to automated lobe segmentations for various lung MRI examinations and quantitative analyses.


Assuntos
Fibrose Cística , Adulto , Criança , Fibrose Cística/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X
14.
Eur J Radiol ; 150: 110259, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334245

RESUMO

PURPOSE: It is known from histology studies that lung vessels are affected in viral pneumonia. However, their diagnostic potential as a chest CT imaging parameter has only rarely been exploited. The purpose of this study is to develop a robust method for automated lung vessel segmentation and morphology analysis and apply it to a large chest CT dataset. METHODS: In total, 509 non-enhanced chest CTs (NECTs) and 563 CT pulmonary angiograms (CTPAs) were included. Sub-groups were patients with healthy lungs (group_NORM, n = 634) and those RT-PCR-positive for Influenza A/B (group_INF, n = 159) and SARS-CoV-2 (group_COV, n = 279). A lung vessel segmentation algorithm (LVSA) based on traditional image processing was developed, validated with a point-of-interest approach, and applied to a large clinical dataset. Total blood vessel volume in lung (TBV) and the blood vessel volume percentage (BV%) of three blood vessel size types were calculated and compared between groups: small (BV5%, cross-sectional area < 5 mm2), medium (BV5-10%, 5-10 mm2) and large (BV10%, >10 mm2). RESULTS: Sensitivity of the LVSA was 84.6% (95 %CI: 73.9-95.3) for NECTs and 92.8% (95 %CI: 90.8-94.7) for CTPAs. In viral pneumonia, besides an increased TBV, the main finding was a significantly decreased BV5% in group_COV (n = 14%) and group_INF (n = 15%) compared to group_NORM (n = 18%) [p < 0.001]. At the same time, BV10% was increased (group_COV n = 15% and group_INF n = 14% vs. group_NORM n = 11%; p < 0.001). CONCLUSION: In COVID-19 and Influenza, the blood vessel volume is redistributed from small to large vessels in the lung. Automated LSVA allows researchers and clinicians to derive imaging parameters for large amounts of CTs. This can enhance the understanding of vascular changes, particularly in infectious lung diseases.


Assuntos
COVID-19 , Influenza Humana , Pneumonia Viral , Humanos , Influenza Humana/diagnóstico por imagem , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Estudos Retrospectivos , SARS-CoV-2
15.
Front Oncol ; 11: 775136, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34938659

RESUMO

The reconstruction of complex midface defects is a challenging clinical scenario considering the high anatomical, functional, and aesthetic requirements. In this study, we proposed a surgical treatment to achieve improved oral rehabilitation and anatomical and functional reconstruction of a complex defect of the maxilla with a vascularized, engineered composite graft. The patient was a 39-year-old female, postoperative after left hemimaxillectomy for ameloblastic carcinoma in 2010 and tumor-free at the 5-year oncological follow-up. The left hemimaxillary defect was restored in a two-step approach. First, a composite graft was ectopically engineered using autologous stromal vascular fraction (SVF) cells seeded on an allogenic devitalized bone matrix. The resulting construct was further loaded with bone morphogenic protein-2 (BMP-2), wrapped within the latissimus dorsi muscle, and pedicled with an arteriovenous (AV) bundle. Subsequently, the prefabricated graft was orthotopically transferred into the defect site and revascularized through microvascular surgical techniques. The prefabricated graft contained vascularized bone tissue embedded within muscular tissue. Despite unexpected resorption, its orthotopic transfer enabled restoration of the orbital floor, separation of the oral and nasal cavities, and midface symmetry and allowed the patient to return to normal diet as well as to restore normal speech and swallowing function. These results remained stable for the entire follow-up period of 2 years. This clinical case demonstrates the safety and the feasibility of composite graft engineering for the treatment of complex maxillary defects. As compared to the current gold standard of autologous tissue transfer, this patient's benefits included decreased donor site morbidity and improved oral rehabilitation. Bone resorption of the construct at the ectopic prefabrication site still needs to be further addressed to preserve the designed graft size and shape.

16.
Quant Imaging Med Surg ; 11(10): 4245-4257, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34603980

RESUMO

BACKGROUND: Manually performed diameter measurements on ECG-gated CT-angiography (CTA) represent the gold standard for diagnosis of thoracic aortic dilatation. However, they are time-consuming and show high inter-reader variability. Therefore, we aimed to evaluate the accuracy of measurements of a deep learning-(DL)-algorithm in comparison to those of radiologists and evaluated measurement times (MT). METHODS: We retrospectively analyzed 405 ECG-gated CTA exams of 371 consecutive patients with suspected aortic dilatation between May 2010 and June 2019. The DL-algorithm prototype detected aortic landmarks (deep reinforcement learning) and segmented the lumen of the thoracic aorta (multi-layer convolutional neural network). It performed measurements according to AHA-guidelines and created visual outputs. Manual measurements were performed by radiologists using centerline technique. Human performance variability (HPV), MT and DL-performance were analyzed in a research setting using a linear mixed model based on 21 randomly selected, repeatedly measured cases. DL-algorithm results were then evaluated in a clinical setting using matched differences. If the differences were within 5 mm for all locations, the cases was regarded as coherent; if there was a discrepancy >5 mm at least at one location (incl. missing values), the case was completely reviewed. RESULTS: HPV ranged up to ±3.4 mm in repeated measurements under research conditions. In the clinical setting, 2,778/3,192 (87.0%) of DL-algorithm's measurements were coherent. Mean differences of paired measurements between DL-algorithm and radiologists at aortic sinus and ascending aorta were -0.45±5.52 and -0.02±3.36 mm. Detailed analysis revealed that measurements at the aortic root were over-/underestimated due to a tilted measurement plane. In total, calculated time saved by DL-algorithm was 3:10 minutes/case. CONCLUSIONS: The DL-algorithm provided coherent results to radiologists at almost 90% of measurement locations, while the majority of discrepent cases were located at the aortic root. In summary, the DL-algorithm assisted radiologists in performing AHA-compliant measurements by saving 50% of time per case.

17.
Diagnostics (Basel) ; 11(5)2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34069328

RESUMO

Pancreatic cystic lesions (PCL) are a frequent and underreported incidental finding on CT scans and can transform into neoplasms with devastating consequences. We developed and evaluated an algorithm based on a two-step nnU-Net architecture for automated detection of PCL on CTs. A total of 543 cysts on 221 abdominal CTs were manually segmented in 3D by a radiology resident in consensus with a board-certified radiologist specialized in abdominal radiology. This information was used to train a two-step nnU-Net for detection with the performance assessed depending on lesions' volume and location in comparison to three human readers of varying experience. Mean sensitivity was 78.8 ± 0.1%. The sensitivity was highest for large lesions with 87.8% for cysts ≥220 mm3 and for lesions in the distal pancreas with up to 96.2%. The number of false-positive detections for cysts ≥220 mm3 was 0.1 per case. The algorithm's performance was comparable to human readers. To conclude, automated detection of PCL on CTs is feasible. The proposed model could serve radiologists as a second reading tool. All imaging data and code used in this study are freely available online.

18.
Eur J Radiol ; 141: 109816, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34157638

RESUMO

OBJECTIVES: Rapid communication of CT exams positive for pulmonary embolism (PE) is crucial for timely initiation of anticoagulation and patient outcome. It is unknown if deep learning automated detection of PE on CT Pulmonary Angiograms (CTPA) in combination with worklist prioritization and an electronic notification system (ENS) can improve communication times and patient turnaround in the Emergency Department (ED). METHODS: In 01/2019, an ENS allowing direct communication between radiology and ED was installed. Starting in 10/2019, CTPAs were processed by a deep learning (DL)-powered algorithm for detection of PE. CTPAs acquired between 04/2018 and 06/2020 (n = 1808) were analysed. To assess the impact of the ENS and the DL-algorithm, radiology report reading times (RRT), radiology report communication time (RCT), time to anticoagulation (TTA), and patient turnaround times (TAT) in the ED were compared for three consecutive time periods. Performance measures of the algorithm were calculated on a per exam level (sensitivity, specificity, PPV, NPV, F1-score), with written reports and exam review as ground truth. RESULTS: Sensitivity of the algorithm was 79.6 % (95 %CI:70.8-87.2%), specificity 95.0 % (95 %CI:92.0-97.1%), PPV 82.2 % (95 %CI:73.9-88.3), and NPV 94.1 % (95 %CI:91.4-96 %). There was no statistically significant reduction of any of the observed times (RRT, RCT, TTA, TAT). CONCLUSION: DL-assisted detection of PE in CTPAs and ENS-assisted communication of results to referring physicians technically work. However, the mere clinical introduction of these tools, even if they exhibit a good performance, is not sufficient to achieve significant effects on clinical performance measures.


Assuntos
Aprendizado Profundo , Embolia Pulmonar , Angiografia , Comunicação , Serviço Hospitalar de Emergência , Humanos , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Eur J Radiol ; 141: 109789, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34051684

RESUMO

PURPOSE: To evaluate potential confounding factors in the quantitative assessment of liver fibrosis and cirrhosis using T1 relaxation times. METHODS: The study population is based on a radiology-information-system database search for abdominal MRI performed from July 2018 to April 2019 at our institution. After applying exclusion criteria 200 (59 ±â€¯16 yrs) remaining patients were retrospectively included. 93 patients were defined as liver-healthy, 40 patients without known fibrosis or cirrhosis, and 67 subjects had a clinically or biopsy-proven liver fibrosis or cirrhosis. T1 mapping was performed using a slice based look-locker approach. A ROI based analysis of the left and the right liver was performed. Fat fraction, R2*, liver volume, laboratory parameters, sex, and age were evaluated as potential confounding factors. RESULTS: T1 values were significantly lower in healthy subjects without known fibrotic changes (1.5 T MRI: 575 ±â€¯56 ms; 3 T MRI: 857 ±â€¯128 ms) compared to patients with acute liver disease (1.5 T MRI: 657 ±â€¯73 ms, p < 0.0001; 3 T MRI: 952 ±â€¯37 ms, p = 0.028) or known fibrosis or cirrhosis (1.5 T MRI: 644 ±â€¯83 ms, p < 0.0001; 3 T MRI: 995 ±â€¯150 ms, p = 0.018). T1 values correlated moderately with the Child-Pugh stage at 1.5 T (p = 0.01, ρ = 0.35). CONCLUSION: T1 mapping is a capable predictor for detection of liver fibrosis and cirrhosis. Especially age is not a confounding factor and, hence, age-independent thresholds can be defined. Acute liver diseases are confounding factors and should be ruled out before employing T1-relaxometry based thresholds to screen for patients with liver fibrosis or cirrhosis.


Assuntos
Cirrose Hepática , Fígado , Fibrose , Humanos , Inflamação/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Estudos Retrospectivos
20.
Diagnostics (Basel) ; 11(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919094

RESUMO

CT patterns of viral pneumonia are usually only qualitatively described in radiology reports. Artificial intelligence enables automated and reliable segmentation of lungs with chest CT. Based on this, the purpose of this study was to derive meaningful imaging biomarkers reflecting CT patterns of viral pneumonia and assess their potential to discriminate between healthy lungs and lungs with viral pneumonia. This study used non-enhanced and CT pulmonary angiograms (CTPAs) of healthy lungs and viral pneumonia (SARS-CoV-2, influenza A/B) identified by radiology reports and RT-PCR results. After deep learning segmentation of the lungs, histogram-based and threshold-based analyses of lung attenuation were performed and compared. The derived imaging biomarkers were correlated with parameters of clinical and biochemical severity (modified WHO severity scale; c-reactive protein). For non-enhanced CTs (n = 526), all imaging biomarkers significantly differed between healthy lungs and lungs with viral pneumonia (all p < 0.001), a finding that was not reproduced for CTPAs (n = 504). Standard deviation (histogram-derived) and relative high attenuation area [600-0 HU] (HU-thresholding) differed most. The strongest correlation with disease severity was found for absolute high attenuation area [600-0 HU] (r = 0.56, 95% CI = 0.46-0.64). Deep-learning segmentation-based histogram and HU threshold analysis could be deployed in chest CT evaluation for the differentiating of healthy lungs from AP lungs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...