Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Quant Imaging Med Surg ; 14(5): 3432-3446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720859

RESUMO

Background: Image-based assessment of prostate cancer (PCa) is increasingly emphasized in the diagnostic workflow for selecting biopsy targets and possibly predicting clinically significant prostate cancer (csPCa). Assessment is based on Prostate Imaging-Reporting and Data System (PI-RADS) which is largely dependent on T2-weighted image (T2WI) and diffusion weighted image (DWI). This study aims to determine whether deep learning reconstruction (DLR) can improve the image quality of DWI and affect the assessment of PI-RADS ≥4 in patients with PCa. Methods: In this retrospective study, 3.0T post-biopsy prostate magnetic resonance imaging (MRI) of 70 patients with PCa in Korea University Ansan Hospital from November 2021 to July 2022 was reconstructed with and without using DLR. Four DWI image sets were made: (I) conventional DWI (CDWI): DWI with acceleration factor 2 and conventional parallel imaging reconstruction, (II) DL1: DWI with acceleration factor 2 using DLR, (III) DL2: DWI with acceleration factor 3 using DLR, and (IV) DL3: DWI with acceleration factor 3 and half average b-value using DLR. Apparent diffusion coefficient (ADC) value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured by one reviewer, while two reviewers independently assessed overall image quality, noise, and lesion conspicuity using a four-point visual scoring system from each DWI image set. Two reviewers also performed PI-RADSv2.1 scoring on lesions suspected of malignancy. Results: A total of 70 patients (mean age, 70.8±9.7 years) were analyzed. The image acquisition time was 4:46 min for CDWI and DL1, 3:40 min for DL2, and 2:00 min for DL3. DL1 and DL2 images resulted in better lesion conspicuity compared to CDWI images assessed by both readers (P<0.05). DLR resulted in a significant increase in SNR, from 38.4±14.7 in CDWI to 56.9±21.0 in DL1. CNR increased from 25.1±11.5 in CDWI to 43.1±17.8 in DL1 (P<0.001). PI-RADS v2.1 scoring for PCa lesions was more agreeable with the DL1 reconstruction method than with CDWI (κ value CDWI, DL1; 0.40, 0.61, respectively). A statistically significant number of lesions were upgraded from PI-RADS <4 in CDWI image to PI-RADS ≥4 in DL1 images for both readers (P<0.05). Most of the PI-RADS upgraded lesions were from higher than unfavorable intermediate-risk groups according to the 2023 National Comprehensive Cancer Network guidelines with statistically significant difference of marginal probability in DL1 and DL2 for both readers (P<0.05). Conclusions: DLR in DWI for PCa can provide options for improving image quality with a significant impact on PI-RADS evaluation or about a 23% reduction in acquisition time without compromising image quality.

2.
Acad Radiol ; 31(4): 1400-1409, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37925344

RESUMO

RATIONALE AND OBJECTIVES: T2-weighted imaging in at least two orthogonal planes is recommended for assessment of the uterus. To determine whether a convolutional neural network-based algorithm could be used for the re-constructions of uterus axes derived from a 3D SPACE with iterative denoising. MATERIALS AND METHODS: 50 patients aged 18-81 (mean: 42) years who underwent an MRI examination of the uterus participated voluntarily in this prospective study after informed consent. In addition to a standard MRI pelvis protocol, a 3D SPACE research application sequence was acquired in sagittal orientation. Reconstructions for both the cervix and the cavum in the short and long axes were performed by a research trainee (T), an experienced radiologist (E), and the prototype software (P). In the next step, the reconstructions were evaluated anonymously by two experienced readers according to 5-point-Likert-Scales. In addition, the length of the cervical canal, the length of the cavum and the distance between the tube angles were measured on all reconstructions. Interobserver agreement was assessed for all ratings. RESULTS: For all axes, significant differences were found between the scores of the reconstructions by research T, E and P. P received higher scores and was preferred significantly more often with the exception of the comparison of the reconstruction Cervix short of E (Cervix short: P vs. T: p = 0.02; P vs. E: p = 0.26; Cervix long: P vs. T: p = 0.01; P vs. E: p < 0.01; Cavum short: P vs. T: p = 0.01; P vs. E: p = 0.02; Cavum long: P vs. T: p < 0.01; P vs. E: p < 0.01). Regarding the measured diameters, (length of cervical canal/cavum/distance between tube angles) significantly larger diameters were recorded for P compared to E and T (Cervix long (mm): T: 25.43; E: 25.65; P: 26.65; Cavum short (mm): T: 26.24; E: 25.04; P: 27.33; Cavum long (mm): T: 31.98; E: 32.91; P: 34.41; P vs. T: p < 0.01); P vs. E: p = 0.04). Moderate to substantial agreement was found between Reader 1 and Reader 2 (range: 0.39-0.67). CONCLUSION: P was able to reconstruct the axes at least as well as or better than E and T. P could thereby lead to workflow facilitation and enable more efficient reporting of uterine MRI.


Assuntos
Imageamento Tridimensional , Útero , Feminino , Humanos , Imageamento Tridimensional/métodos , Estudos Prospectivos , Útero/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Redes Neurais de Computação
3.
Acad Radiol ; 31(3): 921-928, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37500416

RESUMO

RATIONALE AND OBJECTIVES: To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. MATERIALS AND METHODS: A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. RESULTS: The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. CONCLUSION: DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Artefatos , Imageamento por Ressonância Magnética
4.
J Magn Reson Imaging ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37974498

RESUMO

BACKGROUND: For time-consuming diffusion-weighted imaging (DWI) of the breast, deep learning-based imaging acceleration appears particularly promising. PURPOSE: To investigate a combined k-space-to-image reconstruction approach for scan time reduction and improved spatial resolution in breast DWI. STUDY TYPE: Retrospective. POPULATION: 133 women (age 49.7 ± 12.1 years) underwent multiparametric breast MRI. FIELD STRENGTH/SEQUENCE: 3.0T/T2 turbo spin echo, T1 3D gradient echo, DWI (800 and 1600 sec/mm2 ). ASSESSMENT: DWI data were retrospectively processed using deep learning-based k-space-to-image reconstruction (DL-DWI) and an additional super-resolution algorithm (SRDL-DWI). In addition to signal-to-noise ratio and apparent diffusion coefficient (ADC) comparisons among standard, DL- and SRDL-DWI, a range of quantitative similarity (e.g., structural similarity index [SSIM]) and error metrics (e.g., normalized root mean square error [NRMSE], symmetric mean absolute percent error [SMAPE], log accuracy error [LOGAC]) was calculated to analyze structural variations. Subjective image evaluation was performed independently by three radiologists on a seven-point rating scale. STATISTICAL TESTS: Friedman's rank-based analysis of variance with Bonferroni-corrected pairwise post-hoc tests. P < 0.05 was considered significant. RESULTS: Both DL- and SRDL-DWI allowed for a 39% reduction in simulated scan time over standard DWI (5 vs. 3 minutes). The highest image quality ratings were assigned to SRDL-DWI with good interreader agreement (ICC 0.834; 95% confidence interval 0.818-0.848). Irrespective of b-value, both standard and DL-DWI produced superior SNR compared to SRDL-DWI. ADC values were slightly higher in SRDL-DWI (+0.5%) and DL-DWI (+3.4%) than in standard DWI. Structural similarity was excellent between DL-/SRDL-DWI and standard DWI for either b value (SSIM ≥ 0.86). Calculation of error metrics (NRMSE ≤ 0.05, SMAPE ≤ 0.02, and LOGAC ≤ 0.04) supported the assumption of low voxel-wise error. DATA CONCLUSION: Deep learning-based k-space-to-image reconstruction reduces simulated scan time of breast DWI by 39% without influencing structural similarity. Additionally, super-resolution interpolation allows for substantial improvement of subjective image quality. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.

5.
Eur J Radiol ; 165: 110953, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37399667

RESUMO

PURPOSE: Routine multiparametric MRI of the prostate reduces overtreatment and increases sensitivity in the diagnosis of the most common solid cancer in men. However, the capacity of MRI systems is limited. Here we investigate the ability of deep learning image reconstruction to accelerate time consuming diffusion-weighted imaging (DWI) acquisition while maintaining diagnostic image quality. METHOD: In this retrospective study, raw data of DWI sequences of consecutive patients undergoing MRI of the prostate at a tertiary care hospital in Germany were reconstructed using standard and deep learning reconstruction. To simulate a shortening of acquisition times by 39 %, one instead of two and six instead of ten averages were used in the reconstruction of b = 0 and 1000 s/mm2 images, respectively. Image quality was assessed by three radiologists and objective image quality metrics. RESULTS: After the application of exclusion criteria, 35 out of 147 patients examined between September 2022 and January 2023 were included in this study. The radiologists perceived less image noise on deep learning reconstructed images at b = 0 s/mm2 images and ADC maps with good inter-reader agreement. Signal-to-noise ratios were similar overall with discretely reduced values in the transitional zone after deep learning reconstruction. CONCLUSIONS: An acquisition time reduction of 39 % without loss in image quality is feasible in DWI of the prostate when using deep learning image reconstruction.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos
6.
Eur J Radiol ; 166: 110948, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37481831

RESUMO

PURPOSE: This study aimed to assess the technical feasibility, the impact on image quality, and the acquisition time (TA) of a new deep-learning-based reconstruction algorithm in diffusion weighted imaging (DWI) of breast magnetic resonance imaging (MRI). METHODS: Retrospective analysis of 55 female patients who underwent breast DWI at 1.5 T. Raw data were reconstructed using a deep-learning (DL) reconstruction algorithm on a subset of the acquired averages, therefore a reduction of TA. Clinically used standard DWI sequence (DWIStd) and the DL-reconstructed images (DWIDL) were compared. Two radiologists rated the image quality of b800 and ADC images, using a Likert-scale from 1 to 5 with 5 being considered perfect image quality. Signal intensities were measured by placing a region of interest (ROI) at the same position in both sequences. RESULTS: TA was reduced by 40 % in DWIDL, compared to DWIStd, DWIDL improved noise and sharpness while maintaining contrast, the level of artifacts, and diagnostic confidence. There were no differences regarding the signal intensity values of the apparent diffusion coefficient (ADC), (p = 0.955), b50-values (p = 0.070) and b800-values (p = 0.415) comparing standard and DL-imaging. Lesion assessment showed no differences regarding the number of lesions in ADC and DWI (both p = 1.000) and regarding the lesion diameter in DWI (p = 0.961;0.972) and ADC (p = 0.961;0.972). CONCLUSIONS: The novel deep-learning-based reconstruction algorithm significantly reduces TA in breast DWI, while improving sharpness, reducing noise, and maintaining a comparable level of image quality, artifacts, contrast, and diagnostic confidence. DWIDL does not influence the quantifiable parameters.


Assuntos
Mama , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Mama/diagnóstico por imagem , Estudos de Viabilidade
7.
Invest Radiol ; 58(12): 842-852, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37428618

RESUMO

OBJECTIVES: Diffusion-weighted imaging (DWI) enhances specificity in multiparametric breast MRI but is associated with longer acquisition time. Deep learning (DL) reconstruction may significantly shorten acquisition time and improve spatial resolution. In this prospective study, we evaluated acquisition time and image quality of a DL-accelerated DWI sequence with superresolution processing (DWI DL ) in comparison to standard imaging including analysis of lesion conspicuity and contrast of invasive breast cancers (IBCs), benign lesions (BEs), and cysts. MATERIALS AND METHODS: This institutional review board-approved prospective monocentric study enrolled participants who underwent 3 T breast MRI between August and December 2022. Standard DWI (DWI STD ; single-shot echo-planar DWI combined with reduced field-of-view excitation; b-values: 50 and 800 s/mm 2 ) was followed by DWI DL with similar acquisition parameters and reduced averages. Quantitative image quality was analyzed for region of interest-based signal-to-noise ratio (SNR) on breast tissue. Apparent diffusion coefficient (ADC), SNR, contrast-to-noise ratio, and contrast (C) values were calculated for biopsy-proven IBCs, BEs, and for cysts. Two radiologists independently assessed image quality, artifacts, and lesion conspicuity in a blinded independent manner. Univariate analysis was performed to test differences and interrater reliability. RESULTS: Among 65 participants (54 ± 13 years, 64 women) enrolled in the study, the prevalence of breast cancer was 23%. Average acquisition time was 5:02 minutes for DWI STD and 2:44 minutes for DWI DL ( P < 0.001). Signal-to-noise ratio measured in breast tissue was higher for DWI STD ( P < 0.001). The mean ADC values for IBC were 0.77 × 10 -3 ± 0.13 mm 2 /s in DWI STD and 0.75 × 10 -3 ± 0.12 mm 2 /s in DWI DL without significant difference when sequences were compared ( P = 0.32). Benign lesions presented with mean ADC values of 1.32 × 10 -3 ± 0.48 mm 2 /s in DWI STD and 1.39 × 10 -3 ± 0.54 mm 2 /s in DWI DL ( P = 0.12), and cysts presented with 2.18 × 10 -3 ± 0.49 mm 2 /s in DWI STD and 2.31 × 10 -3 ± 0.43 mm 2 /s in DWI DL . All lesions presented with significantly higher contrast in the DWI DL ( P < 0.001), whereas SNR and contrast-to-noise ratio did not differ significantly between DWI STD and DWI DL regardless of lesion type. Both sequences demonstrated a high subjective image quality (29/65 for DWI STD vs 20/65 for DWI DL ; P < 0.001). The highest lesion conspicuity score was observed more often for DWI DL ( P < 0.001) for all lesion types. Artifacts were scored higher for DWI DL ( P < 0.001). In general, no additional artifacts were noted in DWI DL . Interrater reliability was substantial to excellent (k = 0.68 to 1.0). CONCLUSIONS: DWI DL in breast MRI significantly reduced scan time by nearly one half while improving lesion conspicuity and maintaining overall image quality in a prospective clinical cohort.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Cistos , Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Mama/diagnóstico por imagem
8.
Diagn Interv Imaging ; 104(9): 410-418, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37208291

RESUMO

PURPOSE: The purpose of this study was to evaluate the diagnostic performance of visual assessment of diffusion-weighted images (DWI) obtained with a b value of 2500 s/mm2 in addition to a conventional magnetic resonance imaging (MRI) protocol to characterize breast lesions. MATERIALS AND METHODS: This single-institution retrospective study included participants who underwent clinically indicated breast MRI and breast biopsy from May 2017 to February 2020. The examination included a conventional MRI protocol including DWI obtained with a b value of 50 s/mm2 (b50DWI) and a b value of 800 s/mm2 (b800DWI) and DWI obtained with a b value of 2500 s/mm2 (b2500DWI). Lesions were classified using Breast Imaging Reporting and Data Systems (BI-RADS) categories. Three independent radiologists assessed qualitatively the signal intensity within the breast lesions relative to breast parenchyma on b2500DW and b800DWI and measured the b50-b800-derived apparent diffusion coefficient (ADC) value. The diagnostic performances of BI-RADS, b2500DWI, b800DWI, ADC and of a model combining b2500DWI and BI-RADS were evaluated using receiver operating characteristic (ROC) curves analysis. RESULTS: A total of 260 patients with 212 malignant and 100 benign breast lesions were included. There were 259 women and one man with a median age of 53 years (Q1, Q3: 48, 66 years). b2500DWI was assessable in 97% of the lesions. Interobserver agreement for b2500DWI was substantial (Fleiss kappa = 0.77). b2500DWI yielded larger area under the ROC curve (AUC, 0.81) than ADC with a 1 × 10-3 mm2/s threshold (AUC, 0.58; P = 0.005) and than b800DWI (AUC, 0.57; P = 0.02). The AUC of the model combining b2500DWI and BI-RADS was 0.84 (95% CI: 0.79-0.88). Adding b2500DWI to BI-RADS resulted in a significant increase in specificity from 25% (95% CI: 17-35) to 73% (95% CI: 63-81) (P < 0.001) with a decrease in sensitivity from 100% (95% CI: 97-100) to 94% (95% CI: 90-97), (P < 0.001). CONCLUSION: Visual assessment of b2500DWI has substantial interobserver agreement. Visual assessment of b2500DWI offers better diagnostic performance than ADC and b800DWI. Adding visual assessment of b2500DWI to BI-RADS improves the specificity of breast MRI and could avoid unnecessary biopsies.


Assuntos
Neoplasias da Mama , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Sensibilidade e Especificidade
9.
Diagn Interv Imaging ; 104(4): 178-184, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36787419

RESUMO

PURPOSE: The purpose of this study was to investigate the impact of deep learning accelerated diffusion-weighted imaging (DWIDL) in 1.5-T liver MRI on image quality, sharpness, and diagnostic confidence. MATERIALS AND METHODS: One-hundred patients who underwent liver MRI at 1.5-T including DWI with two different b-values (50 and 800 s/mm²) between February and April 2022 were retrospectively included. There were 54 men and 46 women, with a mean age of 59 ± 14 (SD) years (range: 21-88 years). The single average raw data were retrospectively processed using a deep learning (DL) image reconstruction algorithm leading to a simulated acquisition time of 1 min 28 s for DWIDL as compared to 2 min 31 s for standard DWI (DWIStd) via reduction of signal averages. All DWI datasets were reviewed by four radiologists using a Likert scale ranging from 1-4 using the following criteria: noise level, extent of artifacts, sharpness, overall image quality, and diagnostic confidence. Furthermore, quantitative assessment of noise and signal-to-noise ratio (SNR) was performed via regions of interest. RESULTS: No significant differences were found regarding artifacts and overall image quality (P > 0.05). Noise measurements for the spleen, liver, and erector spinae muscles revealed significantly lower noise for DWIDL versus DWIStd (P < 0.001). SNR measurements in the above-mentioned tissues also showed significantly superior results for DWIDL versus DWIStd for b = 50 s/mm² and ADC maps (all P < 0.001). For b = 800 s/mm², significantly superior results were found for the spleen, right hemiliver, and erector spinae muscles. CONCLUSIONS: DL image reconstruction of liver DWI at 1.5-T is feasible including significant reduction of acquisition time without compromised image quality.


Assuntos
Processamento de Imagem Assistida por Computador , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artefatos , Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem , Adulto , Idoso de 80 Anos ou mais
10.
Acad Radiol ; 30(9): 1773-1783, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36764882

RESUMO

RATIONALE AND OBJECTIVES: In breast MRI with diffusion-weighted imaging (DWI), fat suppression is essential for eliminating the dominant lipid signal. This investigation evaluates a combined water-excitation-spectral-fatsat method (WEXfs) versus standard spectral attenuated inversion recovery (SPAIR) in high-resolution 3-Tesla breast MRI. MATERIALS AND METHODS: Multiparametric breast MRI with 2 echo-planar DWI sequences was performed in 83 patients (50.1 ± 12.6 years) employing either WEXfs or SPAIR for fat signal suppression. Three radiologists assessed overall DWI quality and delineability of 88 focal lesions (28 malignant, 60 benign) on images with b values of 800 and 1600 s/mm2, as well as apparent diffusion coefficient (ADC) maps. For each fat suppression method and b value, the longest lesion diameter was determined in addition to measuring the signal intensity in DWI and ADC value in standardized regions of interest. RESULTS: Regardless of b values, image quality (all p < 0.001) and lesion delineability (all p ≤ 0.003) with WEXfs-DWI were deemed superior compared to SPAIR-DWI in benign and malignant lesions. Irrespective of lesion characterization, WEXfs-DWI provided superior signal-to-noise, contrast-to-noise and signal-intensity ratios with 1600 s/mm2 (all p ≤ 0.05). The lesion size difference between contrast-enhanced T1 subtraction images and DWI was smaller for WEXfs compared to SPAIR fat suppression (all p ≤ 0.007). The mean ADC value in malignant lesions was lower for WEXfs-DWI (p < 0.001), while no significant ADC difference was ascertained between both techniques in benign lesions (p = 0.947). CONCLUSION: WEXfs-DWI provides better subjective and objective image quality than standard SPAIR-DWI, resulting in a more accurate estimation of benign and malignant lesion size.


Assuntos
Neoplasias Encefálicas , Neoplasias da Mama , Feminino , Humanos , Neoplasias Encefálicas/patologia , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar , Adulto , Pessoa de Meia-Idade
11.
Cancers (Basel) ; 15(3)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36765539

RESUMO

OBJECTIVES: Thin-slice prostate MRI might be beneficial for prostate cancer diagnostics. However, prolongation of acquisition time is a major drawback of thin-slice imaging. Therefore, the purpose of this study was to investigate the impact of a thin-slice deep learning accelerated T2-weighted (w) TSE imaging sequence (T2DLR) of the prostate as compared to conventional T2w TSE imaging (T2S). MATERIALS AND METHODS: Thirty patients were included in this prospective study at one university center after obtaining written informed consent. T2S (3 mm slice thickness) was acquired first in three orthogonal planes followed by thin-slice T2DLR (2 mm slice thickness) in axial plane. Acquisition time of axial conventional T2S was 4:12 min compared to 4:37 min for T2DLR. Imaging datasets were evaluated by two radiologists using a Likert-scale ranging from 1-4, with 4 being the best regarding the following parameters: sharpness, lesion detectability, artifacts, overall image quality, and diagnostic confidence. Furthermore, preference of T2S versus T2DLR was evaluated. RESULTS: The mean patient age was 68 ± 8 years. Sharpness of images and lesion detectability were rated better in T2DLR with a median of 4 versus a median of 3 in T2S (p < 0.001 for both readers). Image noise was evaluated to be significantly worse in T2DLR as compared to T2S (p < 0.001 and p = 0.021, respectively). Overall image quality was also evaluated to be superior in T2DLR versus T2S with a median of 4 versus 3 (p < 0.001 for both readers). Both readers chose T2DLR in 29 cases as their preference. CONCLUSIONS: Thin-slice T2DLR of the prostate provides a significant improvement of image quality without significant prolongation of acquisition time.

12.
Diagnostics (Basel) ; 13(4)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36832095

RESUMO

This study investigated the image quality and choice of ultra-high b-value of two DWI breast-MRI research applications. The study cohort comprised 40 patients (20 malignant lesions). In addition to s-DWI with two m-b-values (b50 and b800) and three e-b-values (e-b1500, e-b2000, and e-b2500), z-DWI and IR m-b1500 DWI were applied. z-DWI was acquired with the same measured b-values and e-b-values as the standard sequence. For IR m-b1500 DWI, b50 and b1500 were measured, and e-b2000 and e-b2500 were mathematically extrapolated. Three readers used Likert scales to independently analyze all ultra-high b-values (b1500-b2500) for each DWI with regards to scan preference and image quality. ADC values were measured in all 20 lesions. z-DWI was the most preferred (54%), followed by IR m-b1500 DWI (46%). b1500 was significantly preferred over b2000 for z-DWI and IR m-b1500 DWI (p = 0.001 and p = 0.002, respectively). Lesion detection was not significantly different among sequences or b-values (p = 0.174). There were no significant differences in measured ADC values within lesions between s-DWI (ADC: 0.97 [±0.09] × 10-3 mm2/s) and z-DWI (ADC: 0.99 [±0.11] × 10-3 mm2/s; p = 1.000). However, there was a trend toward lower values in IR m-b1500 DWI (ADC: 0.80 [±0.06] × 10-3 mm2/s) than in s-DWI (p = 0.090) and z-DWI (p = 0.110). Overall, image quality was superior and there were fewer image artifacts when using the advanced sequences (z-DWI + IR m-b1500 DWI) compared with s-DWI. Considering scan preferences, we found that the optimal combination was z-DWI with a calculated b1500, especially regarding examination time.

13.
Acad Radiol ; 30(6): 1129-1140, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35871059

RESUMO

RATIONALE AND OBJECTIVES: High-resolution T2-weighted magnetic resonance imaging (MRI) of the pelvis is the main technique used for diagnosing benign and malignant uterine diseases. However, the procedure may be time-consuming and requires training and experience. Therefore, this study was performed to compare the image quality of standard clinical BLADE (stBLADE) with a prototypical accelerated simultaneous multi-slice (SMS) BLADE procedure with either improved temporal resolution (tr) at the same slice thickness (SL) or improved spatial resolution (sr) with the same examination time and a prototypical isotropic 3D SPACE procedure with inner-volume excitation and iterative denoising. MATERIALS AND METHODS: Patients who underwent clinically indicated MRI of the uterus were included in this prospective study and underwent stBLADE (acquisition time, 2 min 59 s; SL, 4 mm) and SMS BLADE (tr) with the same SL (4 mm) but reduced examination time (1 min 20 s) as well as SMS BLADE (sr) with thinner slices (3 mm) and comparable examination time (3 min 16 s). In addition, 3D SPACE was acquired in a sagittal orientation (5 min 36 s). The short axis of the cervix and the long axis of the corpus uteri were reconstructed in 1-mm and 3-mm SLs, retrospectively. Subjective overall image impression, delineation of anatomy/organs, lesion demarcation, and motion artifacts were assessed using a 5-point Likert scale and compared among the different techniques. The preferred sequence was then selected by three independent assessors. RESULTS: The analysis was based on 38 women (mean age, 44 ± 15 years). The overall image impression was similar for stBLADE, SMS BLADE (sr), and SMS BLADE (tr) but was significantly lower for 3D SPACE than stBLADE (p = 0.01). SMS BLADE (sr) was considered the preferred sequence because of slightly better performance in terms of overall image impression, organ delineation, and lesion demarcation, but without statistical significance. Both SMS BLADE (tr) and (sr) produced significantly fewer motion artifacts than stBLADE (p < 0.01 and p = 0.01), with no significant difference between SMS BLADE (tr) and (sr), while 3D SPACE had a significantly lower rating than stBLADE (p < 0.01). Image quality was rated as the least diagnostic criterion in all sequences and all cases. CONCLUSION: SMS BLADE (sr) was the preferred sequence for MRI of the female pelvis, with higher sr than stBLADE. SMS BLADE (tr) may also be used to reduce the acquisition time without compromising image quality. Despite its lower image quality, 3D SPACE can also reduce the examination time and improve the workflow because of the possibility of retrospective multiplanar reconstructions.


Assuntos
Imageamento por Ressonância Magnética , Pelve , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Útero/diagnóstico por imagem , Artefatos
14.
Eur J Radiol ; 155: 110493, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36027759

RESUMO

PURPOSE: We tested a novel multi-parametric (mp) whole body (WB)-MRI evaluation algorithm for medullary lesions in comparison to positron emission tomography (PET) radiotracers 18F-fluorodeoxyglucose (18F-FDG) and 11C-methionine (11C-MET). METHODS AND MATERIALS: This retrospective single-center study included 44 MM patients, who received both 18F-FDG-PET and WB-MRI within ten days. MRI classified focal lesions as vital when showing 1) significant diffusion-restriction, 2) a fat fraction (FF) less than 20 % and 3) homogenous hypointensity on T2-weighted images. On a lesion-by-lesion level the findings were compared to 18F-FDG PET by using a 5-point scoring system (analogous to the Deauville score [DS]). In 24/44 (55 %) patients additional comparison to 11C-MET PET was available. RESULTS: Among two radiologists, an excellent inter-observer reliability for mpWB-MRI in a total of 84 medullary lesions was observed (ICC = 1, k = 1, p <.01). 16/17 (94.1 %) MRI-classified vital lesions had a DS of 4 or 5 on either 18F-FDG-PET or 11C-MET-PET. MRI-rated non-vital lesions correlated with PET-based DS ≤ 3. When results of mpWB-MRI were compared to 18F-FDG, a fair inter-observer agreement was recorded (ICC = 0.52, k = 0.53, p <.01), while for 11C-MET, an excellent concordance rate was achieved (ICC = 0.81, k = 0.79, p <.01). CONCLUSION: The proposed mpWB-MRI interpretation algorithm allowed to assess tumor activity of myeloma lesions with high inter-observer reproducibility. We observed a substantial concordance between the mpWB-MRI classification of lesions and PET assessment based on a semi-automatically calculated 5-point scoring system analogous to the Deauville scores.


Assuntos
Fluordesoxiglucose F18 , Mieloma Múltiplo , Humanos , Imageamento por Ressonância Magnética/métodos , Metionina , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Racemetionina , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
15.
J Magn Reson Imaging ; 56(5): 1343-1352, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35289015

RESUMO

BACKGROUND: Diffusion kurtosis imaging (DKI) is used to differentiate between benign and malignant breast lesions. DKI fits are performed either on voxel-by-voxel basis or using volume-averaged signal. PURPOSE: Investigate and compare DKI parameters' diagnostic performance using voxel-by-voxel and volume-averaged signal fit approach. STUDY TYPE: Retrospective. STUDY POPULATION: A total of 104 patients, aged 24.1-86.4 years. FIELD STRENGTH/SEQUENCE: A 3 T Spin-echo planar diffusion-weighted sequence with b-values: 50 s/mm2 , 750 s/mm2 , and 1500 s/mm2 . Dynamic contrast enhanced (DCE) sequence. ASSESSMENT: Lesions were manually segmented by M.P. under supervision of S.O. (2 and 5 years of experience in breast MRI). DKI fits were performed on voxel-by-voxel basis and with volume-averaged signal. Diagnostic performance of DKI parameters D K (kurtosis corrected diffusion coefficient) and kurtosis K was compared between both approaches. STATISTICAL TESTS: Receiver operating characteristics analysis and area under the curve (AUC) values were computed. Wilcoxon rank sum and Students t-test tested DKI parameters for significant (P <0.05) difference between benign and malignant lesions. DeLong test was used to test the DKI parameter performance for significant fit approach dependency. Correlation between parameters of the two approaches was determined by Pearson correlation coefficient. RESULTS: DKI parameters were significantly different between benign and malignant lesions for both fit approaches. Median benign vs. malignant values for voxel-by-voxel and volume-averaged approach were 2.00 vs. 1.28 ( D K in µm2 /msec), 2.03 vs. 1.26 ( D K in µm2 /msec), 0.54 vs. 0.90 ( K ), 0.55 vs. 0.99 ( K ). AUC for voxel-by-voxel and volume-averaged fit were 0.9494 and 0.9508 ( D K ); 0.9175 and 0.9298 ( K ). For both, AUC did not differ significantly (P = 0.20). Correlation of values between the two approaches was very high (r = 0.99 for D K and r = 0.97 for K ). DATA CONCLUSION: Voxel-by-voxel and volume-averaged signal fit approach are equally well suited for differentiating between benign and malignant breast lesions in DKI. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neuroblastoma , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Acad Radiol ; 2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35144868

RESUMO

RATIONALE AND OBJECTIVES: To investigate image quality and rate of lesion detection in a novel three-dimensional T2-weighted turbo-spin-echo sequence with inner-volume excitation (zoomed imaging) and iterative denoising processing in pelvic MRI at 1.5T. Two-dimensional T2-weighted turbo-spin-echo sequences were used as the clinical reference standard (2D-T2-TSE). MATERIALS AND METHODS: This is a prospective study of patients with various pelvic pathologies. Each patient underwent standard 2D-T2-TSE in three planes with two-fold acceleration as well as a single three-dimensional T2-TSE in the sagittal plane with four-fold acceleration known as Sampling-Perfection-with-Application-optimized-Contrast-using-different-flip-angle-Evolutions (3D-T2-SPACE). The 3D-T2-SPACE images were reconstructed in three orthogonal planes at a slice thickness of 2 mm (vs. 2D-T2-TSE at 4 mm). Two radiologists conducted a qualitative image analysis on standard 2D-T2-TSE and multiplanar reconstructed 3D-T2-SPACE images. These parameters were compared and inter-reader agreement was computed. Furthermore, each reader documented the observed lesions of various pelvic organs. The rate of lesion detection was compared between readers and sequences. Inter-reader and inter-sequence agreement were computed. RESULTS: Forty patients (25 females) were included. Mean patient age was 58 ± 13 years. 3D-T2-SPACE enabled an approximate 22% reduction of acquisition time and 50% of reconstructed slice thickness. 3D-T2-SPACE showed fewer artifacts than 2D-T2-TSE (p < 0.001). However, 2D-T2-TSE was rated to have significantly higher signal intensity than 3D-T2-SPACE (p < 0.001). There were no significant differences between the two sequences regarding all other parameters. Inter-reader agreement regarding image quality parameters was substantial (Kappa = 0.772). For all analyzed pelvic anatomic structures, inter-reader and inter-sequence agreement for lesion detection was excellent (Kappa > 0.80). CONCLUSION: 3D-T2-SPACE with the inner-volume excitation and iterative denoising is clinically feasible at 1.5 T, enabling faster imaging, thinner slices, and significant reduction of artifacts. Despite that signal intensity was inferior in the SPACE images, overall image quality, diagnostic confidence and lesion detection were not compromised. This prospective study sets the stage for further clinical implementation and future investigations tailored to specific indications in pelvis MRI.

17.
J Magn Reson Imaging ; 56(2): 413-422, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35038203

RESUMO

BACKGROUND: Currently, multi-parametric prostate MRI (mpMRI) consists of a qualitative T2 , diffusion weighted, and dynamic contrast enhanced imaging. Quantification of T2 imaging might further standardize PCa detection and support artificial intelligence solutions. PURPOSE: To evaluate the value of T2 mapping to detect prostate cancer (PCa) and to differentiate PCa aggressiveness. STUDY TYPE: Retrospective single center cohort study. POPULATION: Forty-four consecutive patients (mean age 67 years; median PSA 7.9 ng/mL) with mpMRI and verified PCa by subsequent targeted plus systematic MR/ultrasound (US)-fusion biopsy from February 2019 to December 2019. FIELD STRENGTH/SEQUENCE: Standardized mpMRI at 3 T with an additionally acquired T2 mapping sequence. ASSESSMENT: Primary endpoint was the analysis of quantitative T2 values and contrast differences/ratios (CD/CR) between PCa and benign tissue. Secondary objectives were the correlation between T2 values, ISUP grade, apparent diffusion coefficient (ADC) value, and PI-RADS, and the evaluation of thresholds for differentiating PCa and clinically significant PCa (csPCa). STATISTICAL TESTS: Mann-Whitney test, Spearman's rank (rs ) correlation, receiver operating curves, Youden's index (J), and AUC were performed. Statistical significance was defined as P < 0.05. RESULTS: Median quantitative T2 values were significantly lower for PCa in PZ (85 msec) and PCa in TZ (75 msec) compared to benign PZ (141 msec) or TZ (97 msec) (P < 0.001). CD/CR between PCa and benign PZ (51.2/1.77), respectively TZ (19.8/1.29), differed significantly (P < 0.001). The best T2 -mapping threshold for PCa/csPCa detection was for TZ 81/86 msec (J = 0.929/1.0), and for PZ 110 msec (J = 0.834/0.905). Quantitative T2 values of PCa did not correlate significantly with the ISUP grade (rs  = 0.186; P = 0.226), ADC value (rs  = 0.138; P = 0.372), or PI-RADS (rs  = 0.132; P = 0.392). DATA CONCLUSION: Quantitative T2 values could differentiate PCa in TZ and PZ and might support standardization of mpMRI of the prostate. Different thresholds seem to apply for PZ and TZ lesions. However, in the present study quantitative T2 values were not able to indicate PCa aggressiveness. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Próstata , Neoplasias da Próstata , Idoso , Inteligência Artificial , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
18.
Acad Radiol ; 29(1): e1-e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33139155

RESUMO

RATIONALE AND OBJECTIVES: Our study compared sensitivity, specificity, and accuracy of whole-body diffusion-weighted imaging (WB-DWI) using a b-value of 2000 s/mm2 with that of the commonly used b-value of 800 s/mm2 for depiction of active tumor sites in patients with plasma cell diseases. We introduced an ultrahigh b-value to reduce interfering signals from benign and post-therapeutic inactive lesions by suppressing T2-shine-through effects. MATERIALS AND METHODS: The prospective single-center study included patients when they went through a whole-body MRI (WB-MRI) staging or response evaluation procedure. The apparent diffusion coefficient (ADC) and morphologic appearance served as reference for classifying focal lesions on WB-DWI as vital or post-therapeutic. Additionally, we compared our classification with patients' serological markers of disease activity. RESULTS: One hundred participants (65 ± 10 years, 58 men) underwent WB-DWI between June and October 2019. The detection rate of vital focal lesions was similar for both b-values with a sensitivity of 0.99 using b = 800 s/mm2 and 0.98 using b = 2000 s/mm2. By contrast, specificity and accuracy were 0.09 and 0.71 when using a b-value of 800 s/mm2, and 0.96 and 0.98 when using a b-value of 2000 s/mm2, respectively. The difference in specificity and accuracy was statistically significant (p < 0.001). CONCLUSION: Using a b-value of 2000 s/mm2 significantly improved the specificity of lesion detection with WB-DWI as compared to the commonly used b-value of 800 s/mm2. The high b-value significantly reduced signal intensities of post-therapeutic or benign lesions and provided a significantly more accurate representation of active tumor load.


Assuntos
Paraproteinemias , Imagem Corporal Total , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
19.
Diagnostics (Basel) ; 11(10)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34679584

RESUMO

To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and radiologist's diagnostic confidence for detecting common bile duct (CBD) lithiasis, biliary anastomosis stenosis in liver-transplant recipients, and communication of pancreatic cyst with the main pancreatic duct (MPD). Sixty-eight patients with suspicion of choledocholithiasis or biliary anastomosis stenosis after liver transplant, or branch-duct intraductal papillary mucinous neoplasm of the pancreas (BD-IPMN), were included. The relative CBD to peri-biliary tissues (PBT) contrast ratio (CR) was assessed. Overall image quality, presence of artefacts, background noise suppression and the visualization of 12 separated segments of the pancreatic and bile ducts were evaluated by two observers working independently on a five-point scale. Diagnostic confidence was scored on a 1-3 scale. The CS-BH-MRCP presented significantly better CRs (p < 0.0001), image quality (p = 0.004), background noise suppression (p = 0.011), fewer artefacts (p = 0.004) and better visualization of pancreatic and bile ducts segments with the exception of the proximal CBD (p = 0.054), cystic duct confluence (p = 0.459), the four secondary intrahepatic bile ducts, and central part of the MPD (p = 0.885) for which no significant differences were found. Overall, diagnostic confidence was significantly better with the CS-BH-MRCP sequence for both readers (p = 0.038 and p = 0.038, respectively). This study shows that the CS-BH-MRCP sequence presents overall better image quality and bile and pancreatic ducts visualization compared to the conventional RT-MRCP sequence at 3T.

20.
Invest Radiol ; 56(10): 629-636, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34494995

RESUMO

OBJECTIVES: Contrast-enhanced (CE) magnetic resonance imaging (MRI) is the most effective imaging modality for breast cancer detection. A contrast agent-free examination technique would be desirable for breast MRI screening. The purpose of this study was to evaluate the capability to detect and characterize suspicious breast lesions with an abbreviated, non-contrast-enhanced MRI protocol featuring ultra-high b-value diffusion-weighted imaging (DWI) compared with CE images. MATERIALS AND METHODS: The institutional review board-approved prospective study included 127 female subjects with different clinical indications for breast MRI. Magnetic resonance imaging examinations included DWI sequences with b-values of 1500 s/mm2 (b1500) and 2500 s/mm2 (b2500), native T1- and T2-weighted images, and CE sequences at 1.5 T and 3 T scanners. Two reading rounds were performed, including either the b1500 or the b2500 DWI in consecutive assessment steps: (A) maximum intensity projections (MIPs) of DWI, (B) DWI and apparent diffusion coefficient maps, (C) as (B) but with additional native T1- and T2-weighted images, and (D) as (C) but with additional CE images (full-length protocol). Two readers independently determined the presence of a suspicious lesion. Histological confirmation was obtained for conspicuous lesions, whereas the full MRI data set was obtained for inconspicuous and clearly benign lesions. Statistical analysis included calculation of diagnostic accuracy and interrater agreement via the intraclass correlation coefficient. RESULTS: The cohort comprised 116 cases with BI-RADS 1 findings and 138 cases with BI-RADS ≥2 findings, including 38 histologically confirmed malignancies. For (A), breasts without pathological findings could be recognized with high diagnostic accuracy (negative predictive value, ≥97.0%; sensitivity, ≥92.1% for both readers), but with a limited specificity (≥58.3%; positive predictive value, ≥28.6%). Within the native readings, approach (C) with b2500 performed best (negative predictive value, 99.5%; sensitivity, 97.4%; specificity, 88.4%). The intraclass correlation coefficient was between 0.683 (MIP b1500) and 0.996 (full protocol). CONCLUSIONS: A native abbreviated breast MRI protocol with advanced high b-value DWI might allow nearly equivalent diagnostic accuracy as CE breast MRI and seems to be well suited for lesion detection purposes.


Assuntos
Neoplasias da Mama , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...