Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
Spinal Cord ; 52(8): 588-95, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24912546

RESUMO

BACKGROUND: Animal spinal cord injury (SCI) models have proved invaluable in better understanding the mechanisms involved in traumatic SCI and evaluating the effectiveness of experimental therapeutic interventions. Over the past 25 years, substantial gains have been made in developing consistent, reproducible and reliable animal SCI models. STUDY DESIGN: Review. OBJECTIVE: The objective of this review was to consolidate current knowledge on SCI models and introduce newer paradigms that are currently being developed. RESULTS: SCI models are categorized based on the mechanism of injury into contusion, compression, distraction, dislocation, transection or chemical models. Contusion devices inflict a transient, acute injury to the spinal cord using a weight-drop technique, electromagnetic impactor or air pressure. Compression devices compress the cord at specific force and duration to cause SCI. Distraction SCI devices inflict graded injury by controlled stretching of the cord. Mechanical displacement of the vertebrae is utilized to produce dislocation-type SCI. Surgical transection of the cord, partial or complete, is particularly useful in regenerative medicine. Finally, chemically induced SCI replicates select components of the secondary injury cascade. Although rodents remain the most commonly used species and are best suited for preliminary SCI studies, large animal and nonhuman primate experiments better approximate human SCI. CONCLUSION: All SCI models aim to replicate SCI in humans as closely as possible. Given the recent improvements in commonly used models and development of newer paradigms, much progress is anticipated in the coming years.


Assuntos
Modelos Animais de Doenças , Traumatismos da Medula Espinal , Pesquisa Translacional Biomédica , Animais , Humanos , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/terapia
2.
Radiology ; 221(2): 371-9, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11687678

RESUMO

PURPOSE: To develop a low-dose magnetic resonance (MR) renographic method performed with and without an angiotensin converting enzyme (ACE) inhibitor and in conjunction with gadolinium-enhanced MR angiography in patients with suspected renovascular disease. MATERIALS AND METHODS: Thirty-two patients underwent MR renography (turbo fast low-angle shot sequence: repetition time, 5 msec; echo time, 2.3 msec; flip angle, 15 degrees; one coronal image acquired every 2 seconds for 4 minutes) following intravenous injection of 2 mL of gadopentetate dimeglumine, which was repeated following intravenous injection of an ACE inhibitor. Contrast material-enhanced MR angiography was also performed. On the basis of renographic findings, renal cortex and renal medulla enhancement curves and normalized enhancement ratios were analyzed. RESULTS: The cortex and medulla showed an early transient period of enhancement within 20 seconds (vascular phase). During 1-2 minutes, a second, gradual increase in medullary enhancement, reflecting transit of filtered contrast material, was observed that was significantly greater in patients with a serum creatinine level less than 2 mg/dL (177 micromol/L) than in those with a level of 2 mg/dL or greater (P < .01). After injection of the ACE inhibitor, patients with elevated creatinine levels showed low renal medullary enhancement regardless of the presence of renal artery stenosis (RAS). However, in patients with creatinine less than 2 mg/dL, medullary enhancement ratios after injection of the ACE inhibitor were consistently lower in patients with RAS of 50% or greater than in those without stenosis (P = .02 to .08). CONCLUSION: Low-dose MR renography can be performed in the clinical setting before and after injection of an ACE inhibitor, and its potential use for evaluating decreased renal function as a consequence of RAS is promising.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Renografia por Radioisótopo/métodos , Obstrução da Artéria Renal/diagnóstico por imagem , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
3.
J Comput Assist Tomogr ; 25(5): 770-6, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11584239

RESUMO

PURPOSE: Ferumoxtran-10 (ultrasmall superparamagnetic iron oxide; Combidex, AMI-7227) is a long-circulating MR contrast agent with reticuloendothelial uptake known to enhance tissue T1 and T2 relaxation rates. The purpose of this study was to assess the effect of ferumoxtran-10-enhanced MRI in evaluating focal splenic lesions. METHOD: Eighteen patients underwent MR evaluation of the spleen. Two of these patients with exophytic normal splenic tissue (splenules) and 13 of these patients with 24 focal splenic lesions (7 cysts, 2 hemangiomas, 7 metastases, 1 infarct, 7 lymphoma) were assessed by T1-weighted gradient echo and T2-weighted fast SE MRI following intravenous administration of ferumoxtran-10 (1.1 mg of Fe/kg). Qualitative analysis involving improved lesion detection and/or characterization, additional information from postcontrast images affecting staging, and patient management was performed. Quantitative measurements of lesion-to-spleen contrast-to-noise ratio were also performed. RESULTS: Additional information was provided by ferumoxtran-10-enhanced images in 15 of 18 patients. In 8 of 15 (53%) patients, improved lesion detection (i.e., number of lesions) was obtained on contrast-enhanced images. Improved lesion visualization (i.e., conspicuity) was noted in 11 of 15 (73%) of patients. In 10 of 15 (67%) patients, postcontrast imaging provided additional information leading to lesion characterization. Staging of disease and patient management were affected in 5 of 15 (33%) and 6 of 15 (40%) patients, respectively. CONCLUSION: Ferumoxtran-10 is a promising contrast agent for the evaluation of focal splenic lesions.


Assuntos
Meios de Contraste/farmacocinética , Ferro/farmacocinética , Óxidos/farmacocinética , Baço/patologia , Esplenopatias/patologia , Adulto , Idoso , Meios de Contraste/administração & dosagem , Dextranos , Feminino , Óxido Ferroso-Férrico , Humanos , Ferro/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Óxidos/administração & dosagem , Sensibilidade e Especificidade , Distribuição Tecidual
4.
AJR Am J Roentgenol ; 177(5): 1101-7, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11641180

RESUMO

OBJECTIVE: Our purpose was to evaluate a comprehensive MR imaging strategy for recipients of liver transplants that relies on dynamic interpolated three-dimensional (3D) MR imaging for simultaneous vascular, parenchymal, and extrahepatic imaging. MATERIALS AND METHODS: Twenty-three consecutive adult patients underwent 30 MR imaging examinations between 2 days and 99 months (mean, 15 months) after transplantation using a breath-hold 3D gradient-echo sequence (TR range/TE range, 3.7-4.7/1.8-1.9; flip angle, 12-30 degrees ) with an intermittent fat-saturation pulse and interpolation in the section-select direction to enable pixel size 3 mm or less in all dimensions. Unenhanced and triphasic contrast-enhanced 3D imaging (average dose, 0.13 mmol/kg of gadopentetate dimeglumine) was performed. A subset of patients (n = 13) also underwent MR cholangiopancreatography using half-Fourier single-shot turbo spin-echo imaging. MR imaging examinations were correlated with digital subtraction angiography (n = 8), contrast-enhanced cholangiography (n = 9), sonography (n = 13), and histopathology (n = 14). RESULTS: MR imaging revealed abnormal findings in 27 (90%) of 30 examinations, including vascular disease in nine, biliary complications in four, and evidence of intra- or extra-hepatic hepatocellular carcinoma recurrence in six. Digital subtraction angiography confirmed seven MR angiography examinations but suggested disease overestimation in one. Contrast-enhanced cholangiography confirmed findings of MR cholangiopancreatography in seven cases but suggested disease underestimation in two. CONCLUSION: Dynamic interpolated 3D MR imaging combined with dedicated MR cholangiopancreatography can provide a comprehensive assessment of vascular, biliary, parenchymal, and extrahepatic complications in most recipients of liver transplants.


Assuntos
Colangiografia , Colestase Extra-Hepática/diagnóstico , Doenças do Ducto Colédoco/diagnóstico , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Transplante de Fígado , Fígado/irrigação sanguínea , Imageamento por Ressonância Magnética , Complicações Pós-Operatórias/diagnóstico , Doenças Vasculares/diagnóstico , Adulto , Idoso , Anastomose Cirúrgica , Angiografia Digital , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
5.
J Magn Reson Imaging ; 13(6): 889-95, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11382949

RESUMO

The purpose of this study was to develop, standardize, and test reproducibility of a lexicon for reporting contrast-enhanced breast magnetic resonance imaging (MRI) examinations. To standardize breast MRI lesion description and reporting, seven radiologists with extensive breast MRI experience developed consensus on technical detail, clinical history, and terminology reporting to describe kinetic and architectural features of lesions detected on contrast-enhanced breast MR images. This lexicon adapted American College of Radiology Breast Imaging and Data Reporting System terminology for breast MRI reporting, including recommendations for reporting clinical history, technical parameters for breast MRI, descriptions for general breast composition, morphologic and kinetic characteristics of mass lesions or regions of abnormal enhancement, and overall impression and management recommendations. To test morphology reproducibility, seven radiologists assessed morphology characteristics of 85 contrast-enhanced breast MRI studies. Data from each independent reader were used to compute weighted and unweighted kappa (kappa) statistics for interobserver agreement among readers. The MR lexicon differentiates two lesion types, mass and non-mass-like enhancement based on morphology and geographical distribution, with descriptors of shape, margin, and internal enhancement. Lexicon testing showed substantial agreement for breast density (kappa = 0.63) and moderate agreement for lesion type (kappa = 0.57), mass margins (kappa = 0.55), and mass shape (kappa = 0.42). Agreement was fair for internal enhancement characteristics. Unweighted kappa statistics showed highest agreement for the terms dense in the breast composition category, mass in lesion type, spiculated and smooth in mass margins, irregular in mass shape, and both dark septations and rim enhancement for internal enhancement characteristics within a mass. The newly developed breast MR lexicon demonstrated moderate interobserver agreement. While breast density and lesion type appear reproducible, other terms require further refinement and testing to lead to a uniform standard language and reporting system for breast MRI. J. Magn. Reson. Imaging 2001;13:889-895.


Assuntos
Neoplasias da Mama/diagnóstico , Meios de Contraste , Documentação/normas , Aumento da Imagem , Sistemas Computadorizados de Registros Médicos , Terminologia como Assunto , Mama/patologia , Neoplasias da Mama/classificação , Feminino , Humanos
6.
AJR Am J Roentgenol ; 176(6): 1475-82, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11373217

RESUMO

OBJECTIVE: Our aim was to investigate the feasibility of MR imaging as a comprehensive preoperative imaging test for examination of liver donor candidates for adult-to-adult right lobe transplantation. SUBJECTS AND METHODS: Twenty-five consecutive donor candidates were examined at 1.5 T using a torso phased array coil with breath-hold T1- and T2-weighted imaging of the abdomen, MR cholangiography using T2-weighted turbo spin-echo imaging, and MR angiography and venography of the liver using two interpolated three-dimensional spoiled gradient-echo sequences (average dose of gadolinium contrast material, 0.17 mmol/kg). Images were interpreted for liver parenchymal and extrahepatic abnormalities; measurements of right and left lobe liver volumes; definition of hepatic arterial, portal venous, and hepatic venous anatomy; and definition of the biliary branching pattern. Findings were compared with those of conventional angiography in 13 patients, 11 of whom also had surgical findings for comparison. RESULTS: Nine patients were excluded as candidates for donation on the basis of MR imaging findings that included parenchymal or extrahepatic abnormalities in five patients, vascular anomalies in two, and biliary anomalies in three. Two patients who did not undergo surgery underwent conventional angiography that confirmed MR angiographic findings except for a small (<2 mm) accessory left hepatic artery missed on MR imaging. Of the nine patients who underwent successful right hepatectomy, all MR imaging findings were corroborated intraoperatively. In two patients, right hepatectomy was aborted at laparotomy because of intraoperative cholangiography findings; in one of them, the biliary finding was unsuspected on MR imaging. CONCLUSION: A comprehensive MR imaging examination has the potential to serve as the sole preoperative imaging modality for living adult-to-adult liver donor candidates provided improvements in definition of intrahepatic biliary anatomy can be achieved.


Assuntos
Hepatectomia , Transplante de Fígado , Doadores Vivos , Imageamento por Ressonância Magnética , Adulto , Angiografia , Ductos Biliares/anatomia & histologia , Meios de Contraste , Estudos de Viabilidade , Feminino , Artéria Hepática/anatomia & histologia , Veias Hepáticas/anatomia & histologia , Humanos , Fígado/irrigação sanguínea , Angiografia por Ressonância Magnética , Masculino , Veia Porta/anatomia & histologia , Estudos Prospectivos
7.
Radiology ; 219(2): 445-54, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11323471

RESUMO

PURPOSE: To determine the sensitivity and specificity of magnetic resonance (MR) imaging for detection of hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) by using explantation correlation in patients with cirrhosis and no known HCC. MATERIALS AND METHODS: Seventy-one patients without a known history of HCC who underwent MR imaging and subsequent transplantation within 90 days were examined. Breath-hold turbo short inversion time inversion-recovery and/or T2-weighted turbo spin-echo MR images were obtained. Dynamic two- or three-dimensional gadolinium-enhanced gradient-echo MR images were obtained in the hepatic arterial, portal venous, and equilibrium phases. Prospective MR image interpretations were compared directly with explanted liver pathologic results. RESULTS: Eleven (15%) of 71 patients had hepatic malignancies; MR imaging enabled diagnosis of tumor in six (54%) of 11 patients. On a lesion-by-lesion basis, MR imaging depicted 11 of 20 hepatic neoplasms, for an overall sensitivity of 55%. MR imaging depicted four (80%) of five lesions larger than 2 cm, six (50%) of 12 lesions 1-2 cm, and one (33%) of three lesions smaller than 1 cm. MR imaging depicted only nine (15%) of 59 DNS: The specificities of MR imaging for detection of HCC and DNs on a per patient basis were 60 (86%) of 70 patients and 53 (85%) of 62 patients, respectively. CONCLUSION: MR imaging is insensitive for the diagnosis of small (<2-cm) HCCs and DNS:


Assuntos
Carcinoma Hepatocelular/diagnóstico , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Carcinoma Hepatocelular/complicações , Reações Falso-Positivas , Feminino , Humanos , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
Radiology ; 218(1): 47-53, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11152778

RESUMO

PURPOSE: To determine the sensitivity of magnetic resonance (MR) imaging for detection of siderotic nodules in patients with cirrhosis and whether the frequency of hepatocellular carcinoma (HCC) and dysplastic nodules is greater if siderotic nodules are present. MATERIALS AND METHODS: MR imaging (1.5 T) was performed within 0-117 days (mean, 30 days) before liver transplantation in 77 patients. Two readers retrospectively evaluated gradient-echo (GRE) (echo time [TE], > or = 9 and 4-5 msec) and turbo short inversion time inversion-recovery or T2-weighted images for low-signal-intensity nodules. Whole-explant pathologic correlation was available in every case. RESULTS: At explantation, 28 (36%) of 77 patients had HCC, 25 (32%) had dysplastic nodules, and nine (12%) had both; 35 (45%) patients had siderotic nodules. The sensitivity of GRE imaging with 9-msec or longer TE for the detection of siderotic nodules was 80% (28 of 35) but decreased to 31% (11 of 35) with 4-5-msec TE. Frequency of HCC was not significantly higher (P =.27) in patients with (43% [15 of 35]) than in patients without (31% [13 of 42]) siderotic nodules. Frequency of dysplastic nodules also was not significantly higher (P =.42) in patients with (37% [13 of 35]) than in patients without (29% [12 of 42]) siderotic nodules. CONCLUSION: Sensitivity of MR imaging for the detection of siderotic nodules was improved with use of GRE pulse sequences with longer TEs of 9 msec or greater (80%) versus 4-5 msec (31%); however, there was no significant increased frequency of HCC or dysplastic nodules in patients with pathologically proved siderotic nodules.


Assuntos
Carcinoma Hepatocelular/patologia , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Carcinoma Hepatocelular/epidemiologia , Feminino , Humanos , Neoplasias Hepáticas/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Siderose/patologia
12.
J Magn Reson Imaging ; 12(5): 689-701, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11050638

RESUMO

The efficacy of contrast-enhanced magnetic resonance imaging (MRI) for detecting and characterizing, or excluding, hepatic masses was assessed in 404 patients, following the intravenous administration of mangafodipir trisodium (MnDPDP) injection, a hepatic MRI contrast agent. An initial contrast-enhanced computed tomography (CT) examination was followed by unenhanced MRI, injection of MnDPDP (5 micromol/kg IV), and enhanced MRI at 15 minutes post injection. Agreement of the radiologic diagnoses with the patients' final diagnoses was higher for enhanced MRI and for the combined unenhanced and enhanced MRI evaluations than for unenhanced MRI alone or enhanced CT using the clinical diagnosis as the gold standard. Mangafodipir-enhanced MRI uniquely provided additional diagnostic information in 48% of the patients, and patient management was consequently altered in 6% of the patients. MnDPDP-enhanced MRI was comparable or superior to unenhanced MRI and enhanced CT for the detection, classification, and diagnosis of focal liver lesions in patients with known or suspected focal liver disease.


Assuntos
Meios de Contraste , Ácido Edético/análogos & derivados , Aumento da Imagem , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Fosfato de Piridoxal/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Ácido Edético/efeitos adversos , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Fosfato de Piridoxal/efeitos adversos , Sensibilidade e Especificidade
13.
J Comput Assist Tomogr ; 24(5): 773-6, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11045701

RESUMO

OBJECTIVE: To determine if iron containing "siderotic" nodules detected at magnetic resonance (MR) imaging are regenerative (RN) or dysplastic (DN) and to attempt to identify features that may distinguish them. MATERIAL AND METHODS: MR imaging (1.5 T) was performed on 77 cirrhotic patients who underwent orthotopic liver transplantation within 0-117 days (mean 30 days) of MR imaging. Two readers retrospectively evaluated breath-hold gradient-echo pulse sequences (echo time > or =9.0 ms, flip angle < or =45 degrees) for the presence of hypointense nodules, which were classified as micronodular (< or =3 mm), macronodular (>3 mm), or mixed. Nodule distribution was classified as focal (<5), scattered (5-20), or diffuse (>20) per slice. Thin section pathologic correlation was available in all cases, and Prussian blue iron stains were performed. RESULTS: Of 35 patients with pathologically proven siderotic nodules, 10 (29%) had at least 2 siderotic DN. MR detected siderotic nodules in 10 of 10 (100%) patients with siderotic DN and RN, and in 18 of 25 patients (72%) with siderotic RN only. CONCLUSION: Siderotic RN cannot be reliably distinguished from siderotic DN with MR imaging, and therefore the widely used term "siderotic regenerative nodule" should be avoided and replaced by "siderotic nodule."


Assuntos
Cirrose Hepática/patologia , Regeneração Hepática , Fígado/patologia , Imageamento por Ressonância Magnética , Siderose/patologia , Feminino , Humanos , Fígado/fisiologia , Cirrose Hepática/fisiopatologia , Cirrose Hepática/cirurgia , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
J Magn Reson Imaging ; 12(1): 186-97, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10931579

RESUMO

The short-term safety of mangafodipir trisodium (MnDPDP) injection was studied in 546 adults with known or suspected focal liver lesions. An initial contrast-enhanced computed tomography examination was followed by unenhanced magnetic resonance imaging (MRI), injection of MnDPDP (5 micromol/kg), and enhanced MRI. Adverse events were reported for 23% of the patients; most were mild to moderate in intensity, did not require treatment, and were not drug related. The most commonly reported adverse events were nausea (7%) and headache (4%). The incidence of serious adverse events was low (nine events in six patients) and not drug related. Injection-associated discomfort was reported for 69% of the patients, and the most commonly reported discomforts included heat (49%) and flushing (33%). Changes in laboratory values and vital signs were generally transient, were not clinically significant, and did not require treatment. There were no clinically significant short-term risks from exposure to MnDPDP.


Assuntos
Ácido Edético/análogos & derivados , Aumento da Imagem/métodos , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Fosfato de Piridoxal/análogos & derivados , Dor Abdominal/induzido quimicamente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/induzido quimicamente , Meios de Contraste/efeitos adversos , Diagnóstico Diferencial , Ácido Edético/efeitos adversos , Feminino , Humanos , Injeções Intravenosas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Gravidez , Fosfato de Piridoxal/efeitos adversos , Medição de Risco , Sensibilidade e Especificidade , Vômito/induzido quimicamente
16.
Eur Radiol ; 10(8): 1257-60, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10939485

RESUMO

Pelvic arteriovenous malformations (PAV-Ms) are rare disorders traditionally diagnosed by conventional angiography. Breath-hold three-dimensional gadolinium-enhanced MR angiography (3D-Gd-MRA) is a state-of-the-art alternative for vascular imaging. We describe the 3D-Gd-MRA findings in two patients with PAVMs. The 3D-Gd-MRA approach provides a noninvasive and versatile method for evaluation of PAVMs that enables both angiographic assessment of the malformations and evaluation of visceral involvement, which can preclude surgical intervention.


Assuntos
Malformações Arteriovenosas/diagnóstico , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Pelve/irrigação sanguínea , Adulto , Idoso , Malformações Arteriovenosas/terapia , Meios de Contraste , Embolização Terapêutica , Feminino , Gadolínio DTPA , Humanos , Veia Ilíaca/anormalidades , Veia Ilíaca/patologia , Artéria Mesentérica Inferior/anormalidades , Artéria Mesentérica Inferior/patologia , Gravidez , Recidiva , Sensibilidade e Especificidade , Vagina/irrigação sanguínea , Vísceras/irrigação sanguínea
17.
Radiology ; 215(2): 365-72, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10796909

RESUMO

PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size

Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Estudos de Viabilidade , Feminino , Seguimentos , Gadolínio DTPA , Artéria Hepática/patologia , Veias Hepáticas/patologia , Humanos , Aumento da Imagem/métodos , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Veia Porta/patologia , Controle de Qualidade , Reprodutibilidade dos Testes , Respiração , Veia Cava Inferior/patologia
18.
AJR Am J Roentgenol ; 174(2): 499-508, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10658731

RESUMO

OBJECTIVE: We investigated the usefulness of phase-contrast MR imaging to measure renal artery velocity waveforms as an adjunct to renal MR angiography. We also examined whether an angiotensin-converting enzyme (ACE) inhibitor improves the diagnostic accuracy of waveform analysis. SUBJECTS AND METHODS: Thirty-five patients referred for MR angiography of renal arteries underwent non-breath-hold oblique sagittal velocity-encoded phase-contrast MR imaging through both renal hila (TR/TE, 24/5; flip angle, 30 degrees; signal averages, two; encoding velocity, 75 cm/sec) before and after i.v. administration of an ACE inhibitor (enalaprilat). We analyzed velocity waveforms using established Doppler sonographic criteria. A timing examination with a test bolus of gadolinium contrast material was performed to ensure optimal arterial enhancement during breath-hold gadolinium-enhanced three-dimensional gradient-echo MR angiography. RESULTS: MR phase-contrast waveform pattern analysis was 50% (9/18) sensitive and 78% (40/51) specific for the detection of renal artery stenosis equal to or greater than 60% as shown on MR angiography. Sensitivity (67%, 12/18) and specificity (84%, 42/50) increased slightly, but not significantly, after i.v. administration of an ACE inhibitor. Also, the accuracy of quantitative criteria such as acceleration time and acceleration index did not improve after the administration of ACE inhibitor. CONCLUSION: Renal hilar velocity waveforms, measured using non-breath-hold MR phase-contrast techniques with or without an ACE inhibitor, are insufficiently accurate to use in predicting renal artery stenosis.


Assuntos
Inibidores da Enzima Conversora de Angiotensina , Meios de Contraste , Enalaprilato , Hipertensão Renovascular/patologia , Hipertensão Renovascular/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Artéria Renal/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
19.
Radiology ; 213(2): 555-60, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10551241

RESUMO

PURPOSE: To assess the usefulness of three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) venography for evaluation of thoracic central veins. MATERIALS AND METHODS: A retrospective study included 15 patients who underwent 3D gadolinium-enhanced subtraction MR venography with a spoiled gradient-echo sequence before and at multiple times after intravenous administration of 30-40 mL of contrast material. Maximum intensity projection and multiplanar reconstruction images were used to categorize central veins as patent, occluded, or narrowed. Results were compared with findings (in 12 patients) at conventional venography (n = 3), attempted central venous catheter placement (n = 3), or surgery (n = 6). Medical records were retrospectively reviewed to determine if patient care was affected by MR venographic findings. RESULTS: By using MR venograms, an appropriate vessel could be identified for successful placement of a catheter, indwelling venous access device, or arteriovenous hemodialysis graft in all nine patients in whom placement was attempted. MR venography also was predictive of unsuccessful hemodialysis catheter placement in one patient. Conventional venographic findings confirmed MR venographic findings in three patients; in a fourth patient, conventional venography was unsuccessful due to inadequate access. MR venographic findings influenced treatment in 14 patients. CONCLUSION: On the basis of these initial results, 3D gadolinium-enhanced MR venography may facilitate comprehensive evaluation of abnormalities of the central veins in the thorax, particularly with regard to selection of venous access sites.


Assuntos
Gadolínio , Angiografia por Ressonância Magnética/métodos , Flebografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tórax
20.
Radiology ; 212(3): 876-84, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10478260

RESUMO

PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE) sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold examination, or VIBE) with a two-dimensional (2D) GRE breath-hold equivalent. MATERIALS AND METHODS: Twenty consecutive patients underwent 1.5-T MR imaging. The examinations included pre- and postcontrast (20 mL gadopentetate dimeglumine) fat-saturated 2D GRE breath-hold imaging and fat-saturated volumetric interpolated breath-hold imaging before, during (arterial phase), and after injection, with thin (2-mm source images) and thick (8-mm reconstruction images) sections. The three images were compared qualitatively and quantitatively (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]). RESULTS: Qualitatively, the 2-mm source images had poorer pancreatic edge definition on precontrast images compared with the other two data sets (P < .05). On gadolinium-enhanced images, scores for clarity of pancreatic edge, number of vessels visualized, and arterial ghosting were significantly lower for the postcontrast 2D GRE images. Quantitatively, SNR measurements in the liver, aorta, and renal cortex on pre- and postcontrast images were significantly higher for the 8-mm reconstruction images than for the 2D GRE or 2-mm source images (P < .05). Aorta-to-fat CNR was significantly higher on the 8-mm reconstruction images. CONCLUSION: Fat-saturated volumetric interpolated breath-hold images have quality comparable to that of conventional fat-saturated 2D GRE images.


Assuntos
Abdome/patologia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Abdome/irrigação sanguínea , Neoplasias Abdominais/irrigação sanguínea , Neoplasias Abdominais/diagnóstico , Adulto , Idoso , Artefatos , Imagem Ecoplanar , Estudos de Viabilidade , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...