Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(8): 083503, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34470395

RESUMO

The Thomson scattering (TS) diagnostic, one of the key diagnostics used on the tokamaks around the world, is planned for the COMPASS-U tokamak, which is recently under design and construction in the Institute of Plasma Physics in Prague, Czech Republic. This tokamak is supposed to be a world-unique, high magnetic field device with hot walls, allowing for the study of the plasma exhaust in advanced operational scenarios and testing cutting-edge technologies relevant to future fusion reactors, e.g., use of liquid metals. The core and edge TS systems are planned to be designed and operational, with a limited performance, already in the early stage of the tokamak operation. In this contribution, requirements and the most important constraints defining the TS system design are presented. The impact of both the possible collection lens location and spatial resolution on the plasma pedestal observation is simulated. Design considerations also take into account the high-resolution TS core and edge systems available from the COMPASS tokamak, which will be reused. The collection lenses will be newly built. Extension of the detection system will complete the plasma radius coverage in the future. The divertor TS is considered for later periods.

2.
Rev Sci Instrum ; 90(11): 113501, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779455

RESUMO

Due to an increased interest in runaway electron (RE) phenomena in tokamak research, the need for diagnostics of runaway electron population in plasma has emerged. A novel diagnostic of the nonthermal electron cyclotron emission from runaway electrons can be utilized for this purpose. It was designed and installed at the COMPASS tokamak based on the available heterodyne radiometer. The vertical ECE (V-ECE) system uses a 16-channel heterodyne radiometer with a vertically placed E2-band horn antenna with a 76.5-90 GHz frequency range front-end. Simulations with the ray-tracing SPECE code have shown a measurement feasibility of the runaway electrons with energies up to 1 MeV. Due to a low optical depth of the plasma in COMPASS during RE discharges, reflected waves from the tokamak wall can be detected as well. First results show strong connection with other RE diagnostics at COMPASS. The V-ECE can obtain important information about RE population evolution and primary generation mechanism.

3.
Rev Sci Instrum ; 90(3): 033501, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927772

RESUMO

Atomic beam probe is an extension of the routinely used beam emission spectroscopy diagnostic for the plasma edge current fluctuation measurement at magnetically confined plasmas. Beam atoms ionized by the plasma are directed to a curved trajectory by the magnetic field and may be detected close to the wall of the device. The arrival location and current distribution of the ions carry information about the plasma current distribution, the density profile, and the electric potential in the plasma edge. This paper describes a micro-Faraday cup matrix detector for the measurement of the few microampere ion current distribution close to the plasma edge. The device implements a shallow Faraday cup matrix, produced by printed-circuit board technology. Secondary electrons induced by the plasma radiation and the ion bombardment are basically confined into the cups by the tokamak magnetic field. Additionally, a double mask is installed in the front face to limit the ion influx into the cups and supplement secondary electron suppression. The setup was tested in detail using a lithium ion beam in the laboratory. Switching time, cross talk, and fluctuation sensitivity test results in the lab setup are presented along with the detector setup to be installed at the COMPASS tokamak.

4.
Rev Sci Instrum ; 89(11): 113506, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501297

RESUMO

The atomic beam probe diagnostic concept aims at measuring the edge magnetic field and through that edge current distribution in fusion plasmas by observing trajectories of an ion beam stemming from a diagnostic neutral beam. The diagnostic potentially has microsecond scale time resolution and can thus prove to be a powerful option to study fast changes in the edge plasma. A test detector has been installed on the COMPASS tokamak as an extension of the existing lithium beam diagnostic system. It employs a relatively simple concept of an array of conductive detection plates measuring the incident ion current, which is then amplified and converted to a voltage signal. The aim of the test detector is to experimentally examine the idea of the diagnostic and provide background data for design and installation of a final detector. Also, a numerical code based on the CUDA parallel computing platform has been developed for modeling lithium ion trajectories in the given COMPASS plasma discharges. We present the developments of the detector design and test measurements of the diagnostic performed both in a laboratory beam system and on the COMPASS tokamak.

5.
Rev Sci Instrum ; 89(10): 10C105, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399913

RESUMO

Concerning plasma diagnostics based on Thomson scattering (TS), precise adjustment and proper alignment is of great importance in order to provide reliable and accurate measurements. Any misalignment could result in an incorrectly determined plasma density or prevent the measurement with this type of diagnostic altogether. Suitable means of alignment monitoring should be integrated into each TS diagnostic system. Variations of commonly used methods are discussed in this article. Correlation of results from alignment control with performed measurements of vibrations on the COMPASS tokamak is presented. Various techniques of optimization of alignment monitoring are shown. The optimal technique, which could be accommodated during the construction of TS diagnostic systems in future fusion devices, is proposed.

6.
Rev Sci Instrum ; 85(11): 11E431, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430338

RESUMO

The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

7.
Rev Sci Instrum ; 85(11): 11E433, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430340

RESUMO

The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

8.
Rev Sci Instrum ; 85(1): 013509, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24517767

RESUMO

Light reflections are one of the main and often underestimated issues of plasma emissivity reconstruction in visible light spectral range. Metallic and other specular components of tokamak generate systematic errors in the optical measurements that could lead to wrong interpretation of data. Our analysis is performed at data from the tokamak COMPASS. It is a D-shaped tokamak with specular metallic vessel and possibility of the H-mode plasma. Data from fast visible light camera were used for tomographic reconstruction with background reflections subtraction to study plasma boundary. In this article, we show that despite highly specular tokamak wall, it is possible to obtain a realistic reconstruction. The developed algorithm shows robust results despite of systematic errors in the optical measurements and calibration. The motivation is to obtain an independent estimate of the plasma boundary shape.

9.
Appl Opt ; 53(34): 8123-30, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25607972

RESUMO

Typical situations, which can be met during the process of absolute calibration, are shown in the case of a visible light observation system for the COMPASS tokamak. Technical issues and experimental limitations of absolute measurements connected with tokamak operation are discussed.

10.
Rev Sci Instrum ; 83(10): 10E531, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130804

RESUMO

The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in a new case study of the plasma position analyses based on JET soft x-ray (SXR) tomographic reconstruction. Subsequent application of the MFR algorithm on COMPASS data from cameras with absolute extreme ultraviolet (AXUV) photodiodes disclosed a peaked radiating region near the limiter. Moreover, its time evolution indicates transient plasma edge cooling following a radial plasma shift. In the SXR data, MFR demonstrated that a high resolution plasma positioning independent of the magnetic diagnostics would be possible provided that a proper calibration of the cameras on an x-ray source is undertaken.

11.
Rev Sci Instrum ; 83(10): 10E327, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126985

RESUMO

COMPASS tokamak shots at low magnetic field feature overdense plasmas during the extended current flat-top phase. The first harmonic of the electron cyclotron emission is completely cutoff for O and X modes and so the emission caused by electron Bernstein waves (EBWs) propagating obliquely with respect to the magnetic field and undergoing so called EBW-X-O conversion process can be observed. We perform an angular scan of the EBW emission during a set of comparable shots in order to determine the optimum antenna direction. A weak dependence of the radiative temperature on the antenna angles indicates an influence of multiple reflections from the vessel wall. The low temperature at the mode conversion region is responsible for the collisional damping of EBW, which can explain several times lower measured radiative temperature than the electron temperature measured by the Thomson scattering system.

12.
Rev Sci Instrum ; 83(10): 10E350, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127007

RESUMO

The electron density and temperature profiles measured by the Thomson scattering diagnostic on the COMPASS tokamak are used for estimation of electron kinetic energy, energy confinement time, and effective charge number Z(eff). Data are compared with the line-integrated electron density measured by a microwave interferometer in an ohmically heated plasma with a circular cross section. An error analysis of both electron temperature and density are performed by two methods-a constant chi-square boundaries method and a Monte Carlo simulation, determining asymmetrical error bars for the electron temperature.

13.
Rev Sci Instrum ; 81(10): 10D511, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033866

RESUMO

A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.

14.
Rev Sci Instrum ; 81(10): 10D531, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033886

RESUMO

A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

SELEÇÃO DE REFERÊNCIAS