1.
J Arthroplasty ; 38(7S): S265-S273, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105329

RESUMO

BACKGROUND: Larger head-to-neck ratio of dual mobility (DM) hip arthroplasties provide greater range of motion/less risk of dislocation, but raise concerns for high wear and friction. We measured in vitro, the wear rates of contemporary DM hips with highly cross-linked ultra high molecular weight polyethylene (UHWMPE), where it came from, and their frictional torques. METHODS: Hip simulators were used to compare the wear of DM to fixed-bearing (FB) designs of 2 different implants. Each of 8 different configurations underwent millions of simulated walking cycle tests, some as full DM, some as FB controls, some DM with the outer-articulation deliberately immobilized, and some the inner. Wear and 3-dimensional-frictional torques were measured and friction independent of size was deduced. RESULTS: The DM hips produced lower wear and friction-torque than the FB hips. The DM wear during walking gait comes mostly from the smaller inner articular surface. If the outer surface was immobilized, the wear and torque of the inner alone would be small, but the full DM (inner and outer free-to-move) wear and torque were smallest of all. Friction measurements expectedly showed larger hips having higher frictional torques, but the DM showed the lowest, again because its motion was mostly the smaller inner articulation; smaller than even a modern fixed-bearing hip. CONCLUSION: The DM hips appear to combine the benefits of greater range of motion and less impingement of larger hips, with the lower wear and friction of smaller FB hips, with some benefits compromised if the outer or inner articulations are immobilized.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Desenho de Prótese , Fricção , Falha de Prótese
2.
Proc Inst Mech Eng H ; 230(5): 373-88, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27160558

RESUMO

We propose and have evaluated a method to measure hip friction during wear testing on a popular multi-station hip simulator. A 6-degree-of-freedom load cell underneath the specimen sensed forces and torques during implant wear testing of simulated walking. This included internal-external and adduction-abduction rotations which are often neglected during friction testing on pendulum-type machines. Robust mathematical analysis and data processing provided friction estimates in three simultaneous orthogonal rotations, over extended multi-million cycle wear tests. We tested various bearing couples including metal-on-plastic, ceramic-on-plastic, and metal-on-metal material couples. In one test series, new and intentionally scratched CoCrMo 40-mm-diameter femoral heads were tested against conventional ultrahigh-molecular-weight polyethylene, highly cross-linked, and highly cross-linked with vitamin E versions. The scratching significantly increased friction and doubled the wear of all groups. Before scratching, friction levels for the aforementioned plastic groups were 0.056 ± 0.0060, 0.062 ± 0.0080, and 0.070 ± 0.0045, respectively, but after scratching increased to 0.088 ± 0.018, 0.076 ± 0.0066, and 0.082 ± 0.0049, respectively, all statistically significant increases (p = 0.00059, 0.00005, 0.0115, respectively). In another test series of 44-mm femoral head diameter hips, metal-on-plastic hips with conventional ultrahigh-molecular-weight polyethylene showed the lowest friction at 0.045 ± 0.0085, followed by highly cross-linked with 0.046 ± 0.0035 (not significantly different). In a ceramic-on-plastic design with conventional ultrahigh-molecular-weight polyethylene, higher friction 0.079 ± 0.0070 was measured likely due to that ceramic surface being rougher than usual. Metal-on-metal hips were compared without and with a TiN coating, resulting in 0.049 ± 0.014 and 0.097 ± 0.020 friction factors, respectively (statistically significant, p < 0.001), and the coating wore away on all coated hips eventually. Higher friction mostly correlated with higher wear or damage to femoral heads or implant coatings, except for the highly cross-linked wear resistant ultrahigh-molecular-weight polyethylene which had slightly higher friction, confirming the same finding in other independent studies. This type of friction measurements can help screen for clamping and elevated wear of metal-on-metal and resurfacing total hip replacements, surgical malpositioning, and abraded and otherwise damaged surfaces.


Assuntos
Análise de Falha de Equipamento/métodos , Fricção , Prótese de Quadril , Teste de Materiais/métodos , Modelos Biológicos , Desenho de Equipamento , Análise de Falha de Equipamento/instrumentação , Humanos , Teste de Materiais/instrumentação , Metais Pesados , Propriedades de Superfície
3.
J Biomed Mater Res B Appl Biomater ; 104(1): 133-40, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25677393

RESUMO

With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing.


Assuntos
Articulação do Joelho , Prótese do Joelho , Polietilenos , Humanos
4.
J Arthroplasty ; 27(3): 461-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22146382

RESUMO

Concerns about reduced strength, fatigue resistance, and oxidative stability of highly cross-linked and remelted ultrahigh-molecular-weight polyethylene (UHMWPE) have limited its clinical acceptance for total knee arthroplasty. We hypothesized that a highly cross-linked UHMWPE stabilized with vitamin E would have less oxidation and loss of mechanical properties. We compared the oxidation, in vitro strength, fatigue-crack propagation resistance, and wear of highly cross-linked UHMWPE doped with vitamin E to γ-inert-sterilized direct compression-molded UHMWPE (control). After accelerated aging, the control material showed elevated oxidation, loss of small-punch mechanical properties, and loss of fatigue-crack propagation resistance. In contrast, the vitamin E-stabilized material had minimal changes and exhibited 73% to 86% reduction in wear for both cruciate-retaining and posterior-stabilized total knee arthroplasty designs. Highly cross-linked vitamin E-stabilized UHMWPE performed well in vitro.


Assuntos
Prótese do Joelho , Teste de Materiais , Polietileno , Polietilenos , Vitamina E , Artroplastia do Joelho , Desenho de Prótese , Fatores de Tempo