Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(3): 033538, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820020

RESUMO

The TOFOR time-of-flight (TOF) neutron spectrometer at the Joint European Torus (JET) is composed of 5 start (S1) and 32 stop (S2) scintillation detectors. Recently, the data acquisition system (DAQ) of TOFOR was upgraded to equip each of the 37 detectors with its own waveform digitizer to allow for correlated time and pulse height analysis of the acquired data. Due to varying cable lengths and different pulse processing pathways in the new DAQ system, the 160 (5 · 32) different TOF pairs of start-stop detectors must be time-aligned to enable the proper construction of a summed TOF spectrum. Given the time (energy) resolution required by the entire spectrometer system to measure different plasma neutron emission components, it is of importance to align the detector pairs to each other with sub-nanosecond precision. Previously, the alignment partially depended on using fusion neutron data from Ohmic heating phases of JET experimental pulses. The dependence on fusion neutron data in the time alignment process is, however, unsatisfactory as it involves data one would wish to include in an independent analysis for physics results. In this work, we describe a method of time-aligning the detector pairs by using gamma rays. Given the known geometry and response of TOFOR to gamma rays, the time alignment of the detector pairs is found by examining gamma events interacting in coincidence in both S1-S1 and S1-S2 detector combinations. Furthermore, a technique for separating neutron and gamma events in the different detector sets is presented. Finally, the time-aligned system is used to analyze neutron data from Ohmic phases for different plasma conditions and to estimate the Ohmic fuel ion temperature.

2.
Rev Sci Instrum ; 89(10): 10I110, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399869

RESUMO

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. The energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

3.
Rev Sci Instrum ; 85(11): 11D825, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430238

RESUMO

The fuel ion ratio nt/nd is an essential parameter for plasma control in fusion reactor relevant applications, since maximum fusion power is attained when equal amounts of tritium (T) and deuterium (D) are present in the plasma, i.e., nt/nd = 1.0. For neutral beam heated plasmas, this parameter can be measured using a single neutron spectrometer, as has been shown for tritium concentrations up to 90%, using data obtained with the MPR (Magnetic Proton Recoil) spectrometer during a DT experimental campaign at the Joint European Torus in 1997. In this paper, we evaluate the demands that a DT spectrometer has to fulfill to be able to determine nt/nd with a relative error below 20%, as is required for such measurements at ITER. The assessment shows that a back-scattering time-of-flight design is a promising concept for spectroscopy of 14 MeV DT emission neutrons.

4.
Rev Sci Instrum ; 85(11): 11E121, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430300

RESUMO

This paper presents two different conceptual designs of neutron cameras for Mega Ampere Spherical Tokamak (MAST) Upgrade. The first one consists of two horizontal cameras, one equatorial and one vertically down-shifted by 65 cm. The second design, viewing the plasma in a poloidal section, also consists of two cameras, one radial and the other one with a diagonal view. Design parameters for the different cameras were selected on the basis of neutron transport calculations and on a set of target measurement requirements taking into account the predicted neutron emissivities in the different MAST Upgrade operating scenarios. Based on a comparison of the cameras' profile resolving power, the horizontal cameras are suggested as the best option.

5.
Rev Sci Instrum ; 83(10): 10D907, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130798

RESUMO

A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.

6.
Rev Sci Instrum ; 83(10): 10D916, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23130799

RESUMO

In this paper, we present a method to derive n(t)/n(d) using the ratio of the thermonuclear neutron emission to the beam-target neutron emission. We apply it to neutron spectroscopy data from the magnetic proton recoil spectrometer taken during the deuterium tritium experiment at JET. n(t)/n(d)-values obtained using neutron spectroscopy are in qualitative agreement with those from other diagnostics measuring the isotopic composition of the exhaust in the divertor.

7.
Rev Sci Instrum ; 83(10): 10D910, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126913

RESUMO

A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n)(3)He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled. Good agreement is found between the experimental data and the simulations. Examples are given showing the sensitivity of the recoil proton pulse height spectra to different observation angles with respect the neutral beam injection and the plasma rotation direction.

8.
Rev Sci Instrum ; 81(10): 10D324, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058455

RESUMO

The determination of the fuel ion ratio n(t)/n(d) in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of 0.016 keV and for n(T)/n(D)<0.6. A crucial issue is the signal-to-background situation in the measurement of the weak 2.5 MeV emission from DD reactions in the presence of a background of scattered 14 MeV DT neutrons. Important experimental input and corroboration for this assessment are presented from the time-of-flight neutron spectrometer at JET where the presence of a strong component of backscattered neutrons is observed. Neutron emission components on ITER due to beam-thermal and tritium-tritium reactions can further enhance the prospects for NES.

9.
Rev Sci Instrum ; 81(10): 10D336, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058459

RESUMO

Recent experiments at JET aimed at producing 4He ions in the MeV range through third harmonic ion cyclotron resonance heating (ICRH) acceleration of 4He beams in a 4He dominated plasma. MeV range D was also present through parasitic ICRH absorption on residual D. In this contribution, we analyze TOFOR neutron spectrometer data from these experiments. A consistent description of the data is obtained with d(d,n)3He and 9Be(α,n)12C neutron components calculated using Stix distributions for the fast D and 4He, taking finite Larmor radius effects into account and with a ICRH power partition of P(D)(RF) = 0.01×P(4He)(RF), in agreement with TOMCAT simulations.

10.
Rev Sci Instrum ; 81(10): 10D337, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21058461

RESUMO

In a fusion reactor with high energy gain, the fusion power will be mainly thermonuclear (THN). Measurements of the THN neutron rate are a good performance indicator of a fusion plasma, requiring neutron emission spectroscopy (NES) measurements to distinguish thermal and nonthermal contributions. We report here on recent NES results from JET high-performance plasmas with high fractions (about 65%) of THN emission. The analysis is made with a framework for analyzing NES data, taking into account THN reactions and beam-target reactions. The results are used to extrapolate to the equivalent DT rates. Finally, we discuss the applicability of using NES in the deuterium phase of ITER, both for the extrapolations to ITER's future DT performance as well as for the measurements of confined energetic ions.

11.
Rev Sci Instrum ; 81(10): 10D315, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033841

RESUMO

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

12.
Rev Sci Instrum ; 80(6): 063505, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19572466

RESUMO

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.

13.
Rev Sci Instrum ; 79(10): 10E510, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19068504

RESUMO

A method to generate modeled neutron spectra from bulk and fast ion distributions simulated by TRANSP has been developed. In this paper, modeled data generated from fuel ion distributions modeled with TRANSP is compared to measured data from two neutron spectrometers with different lines of sight; TOFOR with a radial one and the MPRu with a tangential one. The information obtained from the analysis of the measured neutron spectra such as the relative intensity of the emission from different ion populations places additional constraints on the simulation and can be used to adjust the parameters of the simulation.

14.
Rev Sci Instrum ; 79(10): 10E514, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19068506

RESUMO

The effect of ion cyclotron resonance heating (ICRH) on (3He)D plasmas at JET was studied with the time of flight optimized rate (TOFOR) spectrometer dedicated to 2.5 MeV dd neutron measurements. In internal transport barrier (ITB) plasma experiments with large 3He concentrations (X(3He)>15%) an increase in neutron yield was observed after the ITB disappeared but with the auxiliary neutral beam injection and ICRH power still applied. The analysis of the TOFOR data revealed the formation of a high energy (fast) D population in this regime. The results were compared to other mode conversion experiments with similar X(3He) but slightly different heating conditions. In this study we report on the high energy neutron tails originating from the fast D ions and their correlation with X(3He) and discuss the light it can shed on ICRH-plasma power coupling mechanisms.

15.
Rev Sci Instrum ; 79(10): 10E513, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19068505

RESUMO

A determination of fast ion population parameters such as intensity and kinetic temperature is important for fusion reactors. This becomes more challenging with finer time resolution of the measurements, since the limited data in each time slice cause increasing statistical variations in the data. This paper describes a framework using Bayesian-regularized neural networks (NNs) designed for such a task. The method is applied to the TOFOR 2.5 MeV fusion neutron spectrometer at JET. NN training data are generated by random sampling of variables in neutron spectroscopy models. Ranges and probability distributions of the parameters are chosen to match the experimental data. Results have shown good performance both on synthetic and experimental data. The latter was assessed by statistical considerations and by examining the robustness and time consistency of the results. The regularization of the training algorithm allowed for higher time resolutions than simple forward methods. The fast execution time makes this approach suitable for real-time analysis with a time resolution limit in the microsecond time scale.

16.
Phys Rev Lett ; 87(22): 222501, 2001 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-11736396

RESUMO

A rotational band with seven gamma-ray transitions between states with spin 2 Planck's constant and 16 Planck's constant has been observed in the doubly magic, self-conjugate nucleus (40)(20)Ca(20). The measured transition quadrupole moment of 1.80(+0.39)(-0.29)eb indicates a superdeformed shape with a deformation beta(2) = 0.59(+0.11)(-0.07). The features of this band are explained by cranked relativistic mean field calculations to arise from an 8-particle 8-hole excitation.

17.
Phys Rev Lett ; 87(12): 122501, 2001 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-11580500

RESUMO

Gamma rays from the N = Z-2 nucleus (50)Fe have been observed, establishing the rotational ground state band up to the state J(pi) = 11+ at 6.994 MeV excitation energy. The experimental Coulomb energy differences, obtained by comparison with the isobaric analog states in its mirror (50)Cr, confirm the qualitative interpretation of the backbending patterns in terms of successive alignments of proton and neutron pairs. A quantitative agreement with experiment has been achieved by exact shell model calculations, incorporating the differences in radii along the yrast bands, and properly renormalizing the Coulomb matrix elements in the pf model space.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...