Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Insects ; 12(8)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34442286

RESUMO

The impact of avian predation on a declining population of the spruce budworm, Choristoneura fumifereana (Clem.), was measured using single-tree exclosure cages in a mature stand of balsam fir, Abies balsamea (L.), and white spruce, Picea glauca (Moench.) Voss. Bird population censuses and observations of foraging and nest-feeding activity were also made to determine the response of budworm-linked warblers to decreasing food availability. Seasonal patterns of foraging. as well as foraging success in the declining prey population was compared to similar information from birds observed in another stand where the spruce budworm population was rising. Avian predation was an important source of mortality between the 4th instar and moth emergence in the declining outbreak population. Mortality by predation increased from negligible to over 98% as budworm density dropped from 100 to <1 larva/kg of host foliage, over 3 years. Calculations based on nest-feeding activity and basic metabolic demands support these observed rates. Seasonal and yearly differences in predation rates observed between the two host-tree species correspond to equivalent shifts in bird foraging behavior in response to dropping insect density. In particular, a preference for searching on white spruce disappeared, although budworm-linked birds remained more efficient at finding food on this plant. The ability to change foraging behavior as prey density dropped differed between bird species.

2.
Ultrasound ; 24(2): 68-93, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27482276

RESUMO

AIMS: Imaging faults with ultrasound transducers are common. Failed elements on linear and curvilinear array transducers can usually be detected with a simple image uniformity or 'paperclip' test. However, this method is less effective for phased array transducers, commonly used in cardiac imaging. The aim of this study was to assess whether the presence of failed elements could be detected through measurement of the resolution integral (R) using the Edinburgh Pipe Phantom. METHODS: A 128-element paediatric phased array transducer was studied. Failed elements were simulated using layered polyvinyl chloride (PVC) tape as an attenuator and measurements of resolution integral were carried out for several widths of attenuator. RESULTS: All widths of attenuator greater than 0.5 mm resulted in a significant reduction in resolution integral and low contrast penetration measurements compared to baseline (p < 0.05). CONCLUSIONS: Measurements of resolution integral and low contrast penetration both have the potential to be used as straightforward and inexpensive tests to detect failed elements on phased array transducers. Particularly encouraging is the result for low contrast penetration as this is a quick and simple measurement to make and can be performed with many different test objects, thus enabling 'in-the-field' checks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...