Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 8(12): e12116, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36544820

RESUMO

The lateral flow immunoassay (LFIA) is a paper-based platform with extensive application in point-of-care (POC) testing and many fields. However, its clinical application is severely limited due to the lack of quantitative ability of standard LFIA tests; this augmentation provides the system with quantifying the signal from magenta-colored AuNPs. To address this issue, we proposed an ultra-compact optical system that allowed LFIAs to be performed more accurately and objectively. The experimental setup consisted of multiple optical accessories manufactured by 3D printing (STEP files were included). A high-resolution printer was used to print out a magenta card model for the LFIA, whose color code, ranging from 255, 255, 255 to 255, 0, 255 in the RGB (red, green, blue) format, represents different levels of magenta color intensity (from 0% to 100%) and thus the results of LFIA test strips. A mathematical model was built using a calibration curve to describe the relationship between magenta color value and reflectance spectrum. In addition, a spectrum module was integrated into the proposed system to identify and quantify LFIA results. This integration represents a pioneering step in developing portable detection techniques that facilitate quantifying LFIA results. Finally, we expect this ultra-compact optical spectroscopy system to have great potential for novel clinical applications.

2.
Med Sci Monit ; 28: e935812, 2022 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-35340017

RESUMO

BACKGROUND The COVID-19 pandemic has spread globally in a short period of time. It is known that antibody (nAb) level can effectively predict vaccine efficacy, which leads to the exploration of vaccine trials for efficacy assessment. Thus, the current study aimed to develop a platform to quantify nAb levels faster, at lower cost, and with better efficiency. MATERIAL AND METHODS A total of 69 sera samples were collected for the research, 28 of which were from unvaccinated participants. The other 27 samples and the remaining 14 samples were from the participants who had received the first and second dose, respectively, of AZ vaccine 1 month before. With cPass assays (Genscript cPass nAb ELISA assay) used as a criterion standard and lateral flow immunoassay kit (Healgen Scientific - LFIA test kit) coupled with a spectrometer (LFIA+S) for checking each specimen, we aimed to detect the presence of neutralizing antibodies in sera and to confirm the relationship between the inhibition rate from cPass assays and the nAb index from the LFIA+S. RESULTS Data analysis of the research were taken from the certified ELISA and LFIA+S, which indicated a high consistency (Pearson's r =0.864; ICC=0.90138) between the 2 methods. CONCLUSIONS The dataset demonstrated that LFIA+S was affordable, had a strong correlation with results of the cPass nAbs detection kit, and has potential clinical applications, with an exclusive feature that allows non-experts to use it with ease. It is believed that the proposed platform can be promoted in the near future.


Assuntos
COVID-19 , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Imunoensaio/métodos , Pandemias , SARS-CoV-2
3.
Micromachines (Basel) ; 12(3)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803850

RESUMO

As coronavirus disease 2019 (COVID-19) continues to spread around the world, the establishment of decentralized severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) diagnostics and point-of-care testing is invaluable. While polymerase chain reaction (PCR) has been the gold standard for COVID-19 screening, serological assays detecting anti-SARS-CoV-2 antibodies in response to past and/or current infection remain vital tools. In particular, lateral flow immunoassay devices are easy to produce, scale, distribute, and use; however, they are unable to provide quantitative information. To enable quantitative analysis of lateral flow immunoassay device results, microgating technology was used to develop an innovative spectrochip that can be integrated into a portable, palm-sized device that was capable of capturing high-resolution reflectance spectrum data for quantitative immunoassay diagnostics. Using predefined spiked concentrations of recombinant anti-SARS-CoV-2 immunoglobulin G (IgG), this spectrochip-coupled immunoassay provided extraordinary sensitivity, with a detection limit as low as 186 pg/mL. Furthermore, this platform enabled the detection of anti-SARS-CoV-2 IgG in all PCR-confirmed patients as early as day 3 after symptom onset, including two patients whose spectrochip tests would be regarded as negative for COVID-19 using a direct visual read-out without spectral analysis. Therefore, the quantitative lateral flow immunoassay with an exceptionally low detection limit for SARS-CoV-2 is of value. An increase in the number of patients tested with this novel device may reveal its true clinical potential.

4.
J Nanobiotechnology ; 19(1): 89, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33781277

RESUMO

BACKGROUND: Areas of hypoxia are often found in triple-negative breast cancer (TNBC), it is thus more difficult to treat than other types of breast cancer, and may require combination therapies. A new strategy that combined bioreductive therapy with photodynamic therapy (PDT) was developed herein to improve the efficacy of cancer treatment. Our design utilized the characteristics of protoporphyrin IX (PpIX) molecules that reacted and consumed O2 at the tumor site, which led to the production of cytotoxic reactive oxygen species (ROS). The low microenvironmental oxygen levels enabled activation of a bioreductive prodrug, tirapazamine (TPZ), to become a toxic radical. The TPZ radical not only eradicated hypoxic tumor cells, but it also promoted therapeutic efficacy of PDT. RESULTS: To achieve the co-delivery of PpIX and TPZ for advanced breast cancer therapy, thin-shell hollow mesoporous Ia3d silica nanoparticles, designated as MMT-2, was employed herein. This nanocarrier designed to target the human breast cancer cell MDA-MB-231 was functionalized with PpIX and DNA aptamer (LXL-1), and loaded with TPZ, resulting in the formation of TPZ@LXL-1-PpIX-MMT-2 nanoVector. A series of studies confirmed that our nanoVectors (TPZ@LXL-1-PpIX-MMT-2) facilitated in vitro and in vivo targeting, and significantly reduced tumor volume in a xenograft mouse model. Histological analysis also revealed that this nanoVector killed tumor cells in hypoxic regions efficiently. CONCLUSIONS: Taken together, the synergism and efficacy of this new therapeutic design was confirmed. Therefore, we concluded that this new therapeutic strategy, which exploited a complementary combination of PpIX and TPZ, functioned well in both normoxia and hypoxia, and is a promising medical procedure for effective treatment of TNBC.


Assuntos
Antineoplásicos/farmacologia , Nanopartículas/uso terapêutico , Fotoquimioterapia/métodos , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Animais , Aptâmeros de Nucleotídeos , Linhagem Celular Tumoral , Terapia Combinada , Feminino , Humanos , Camundongos , Oxigênio , Pró-Fármacos , Espécies Reativas de Oxigênio , Dióxido de Silício , Tirapazamina , Carga Tumoral , Hipóxia Tumoral/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto
5.
Diagnostics (Basel) ; 11(1)2020 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-33375112

RESUMO

Paraquat is a highly toxic herbicide. Paraquat poisoning is often fatal and is an important public health threat in many places. The quick identification and timely initiation of treatment based on timely analysis of the paraquat concentration in urine/serum could improve the prognosis for patients. However, current paraquat concentration measurements are time-consuming and difficult to implement due to the expensive and bulky equipment required. To address these practical challenges, paper-based devices have emerged as alternative diagnostic tools for improving point-of-care testing. In this study, we demonstrate the successful use of a paper-based analytical device for the accurate detection of urine paraquat concentration. The developed paper-based analytical device employs colorimetric paraquat concentration measurements. The R2 value for the urine paraquat standard curve was 0.9989, with a dynamic range of 0-100 ppm. The limit of detection was 3.01 ppm. Two other optical-based approaches, Spectrochip and NanoDrop, were used for comparison. The results suggest that the developed paper-based analytical device is comparable to other colorimetric measurements, as determined by Bland-Altman analysis. The device was clinically validated using urine from six paraquat-poisoned patients. The results prove that the developed paper-based analytical device is accurate, easy-to-use, and efficient for urine paraquat concentration measurement, and may enable physicians to improve clinical management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...