Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 9(9): 8075-8082, 2017 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-28212003

RESUMO

This paper reports a facile sol-gel synthesis method to successfully prepare the TiP2O7/expanded graphite (EG) nanocomposite as an advanced anode material for aqueous lithium-ion batteries. The constructed TiP2O7 nanocomposites (50-100 nm) are in situ encapsulated in the pore and layer structure of expanded graphite with good conductivity and high specific surface area. As a consequence, the resulting TiP2O7/EG electrode exhibits a reversible capacity of 66 mAh g-1 at 0.1 A g-1 with an appropriate potential of -0.6 V before hydrogen evolution in aqueous electrolytes, and also demonstrates greatly enhanced cycling stability with 75% capacity retention after 1000 cycles at the current density of 0.5 A g-1. A full cell consisting of TiP2O7/EG anode, LiMn2O4 cathode, and 1 M Li2SO4 electrolyte delivers a specific energy of 60 Wh kg-1 calculated on the weight of both cathode and anode materials with an operational voltage of 1.4 V. It also exhibits superior rate capability and remarkable cycling performance with a capacity maintenance of 66% over 500 cycles at 0.2 A g-1 and 61% at 1 A g-1 over 2000 cycles.

2.
Biosens Bioelectron ; 79: 894-900, 2016 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-26800205

RESUMO

Nitromethane (CH3NO2) is an important organic chemical raw material with a wide variety of applications as well as one of the most common pollutants. Therefore it is pretty important to establish a simple and sensitive detection method for CH3NO2. In our study, a novel amperometric biosensor for nitromethane (CH3NO2) based on immobilization of electrochemically-reduced graphene oxide (rGO), chitosan (CS) and hemoglobin (Hb) on a glassy carbon electrode (GCE) was constructed. Scanning electron microscopy, infrared spectroscopy and electrochemical methods were used to characterize the Hb-CS/rGO-CS composite film. The effects of scan rate and pH of phosphate buffer on the biosensor have been studied in detail and optimized. Due to the graphene and chitosan nanocomposite, the developed biosensor demonstrating direct electrochemistry with faster electron-transfer rate (6.48s(-1)) and excellent catalytic activity towards CH3NO2. Under optimal conditions, the proposed biosensor exhibited fast amperometric response (<5s) to CH3NO2 with a wide linear range of 5 µM~1.46 mM (R=0.999) and a low detection limit of 1.5 µM (S/N=3). In addition, the biosensor had high selectivity, reproducibility and stability, providing the possibility for monitoring CH3NO2 in complex real samples.


Assuntos
Técnicas Biossensoriais/métodos , Quitosana/química , Grafite/química , Hemoglobinas/química , Metano/análogos & derivados , Nanocompostos/química , Nitroparafinas/análise , Óxidos/química , Animais , Bovinos , Técnicas Eletroquímicas/métodos , Metano/análise , Nanocompostos/ultraestrutura , Oxirredução , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...