Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(7): 1558-1566, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35508760

RESUMO

INTRODUCTION: Left bundle branch area pacing (LBBAP) maintains electrical and mechanical synchronization of the ventricles. It is a relatively physiological pacing mode, with low and stable pacing threshold and wider indications. LBBAP in children has been rarely reported. METHODS: This study observed 12 children attempted LBBAP from January 2019 to January 2021 in the department of pediatric cardiology of Anzhen Hospital prospectively. Clinical data, pacing parameters, electrocardiograms, intracardiac electrograms, echocardiographic measurements and complications were recorded at implant and during follow-up. RESULTS: The 12 patients aged between 3 and 14 years old and weighted from 13 to 48 kg. Eleven patients were diagnosed with third-degree atrioventricular block and 1 patient (case 4) suffered from cardiac dysfunction due to right ventricular apical pacing (RVAP). Left bundle branch area pacing was successfully achieved in all patients with narrow QRS complexes and V1 lead showed changes like right bundle branch block in the pacing electrocardiogram. Left ventricular ejection fraction in case 4 recovered on the 3rd day after LBBAP. The median of left ventricular end diastolic diameter Z score of the 12 patients decreased from 1.75 to 1.05 3 months after implantation (p < 0.05). The median of paced QRS duration was 103 ms. The median of pacing threshold, R-wave amplitude and impedance were 0.85 V, 15 mV and 717 Ω respectively and remained stable during follow-up. No complications such as loss of capture, lead dislodgement or septal perforation occurred. CONCLUSIONS: Left bundle branch area pacing can be performed safely in children with narrow QRS duration and stable pacing parameters. Cardiac dysfunction caused by long-term RVAP can be corrected by LBBAP quickly.


Assuntos
Fascículo Atrioventricular , Cardiopatias , Adolescente , Estimulação Cardíaca Artificial/efeitos adversos , Criança , Pré-Escolar , Eletrocardiografia , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia
2.
Preprint em Inglês | bioRxiv | ID: ppbiorxiv-422952

RESUMO

The SARS-CoV-2 pandemic has affected more than 70 million people worldwide and resulted in over 1.5 million deaths. A broad deployment of effective immunization campaigns to achieve population immunity at global scale will depend on the biological and logistical attributes of the vaccine. Here, two adeno-associated viral (AAV)-based vaccine candidates demonstrate potent immunogenicity in mouse and nonhuman primates following a single injection. Peak neutralizing antibody titers remain sustained at 5 months and are complemented by functional memory T-cells responses. The AAVrh32.33 capsid of the AAVCOVID vaccine is an engineered AAV to which no relevant pre-existing immunity exists in humans. Moreover, the vaccine is stable at room temperature for at least one month and is produced at high yields using established commercial manufacturing processes in the gene therapy industry. Thus, this methodology holds as a very promising single dose, thermostable vaccine platform well-suited to address emerging pathogens on a global scale.

3.
Chinese Journal of Pediatrics ; (12): 107-112, 2020.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-799309

RESUMO

Objective@#To explore the safety and effectiveness of left bundle branch area pacing (LBBAP) in children.@*Methods@#Clinical data, pacing electrocardiogram and parameters of 6 patients (5 females and 1 male) who underwent permanent pacemaker implantation and LBBAP from January to June 2019 in the Department of Pediatric Cardiology of Anzhen Hospital were retrospectively analyzed.@*Results@#The weight of the 6 patients aged between 9 and 14 years ranged from 26 to 48 kg. Five patients were diagnosed with third degree atrioventricular block, and 1 patient was diagnosed with cardiac dysfunction after right ventricular apical pacing. Cardiac function decreased in one patient and remained normal in the other five patients. Left ventricular end diastolic diameter (LVEDD) Z score was 1.85±0.65. V1 lead showed changes like right bundle branch block in pacing electrocardiogram. No significant difference was found regarding QRS wave duration ((95±13) ms vs. (111±20) ms, t=-1.610, P>0.05) between preoperation and postoperation. Pacing threshold was (0.85±0.26) V. The sensing threshold was (15.0±4.3) mV and the impedance was (717±72) Ω. P potential was recorded in 3 cases. The earliest left ventricular local activation time was (56±5) ms and remained stable at different output voltages. Postoperative echocardiography revealed that the electrodes were located near the endocardium of the left ventricular septum. No complications such as myocardial perforation and electrode dislocation occurred during follow-up. The pacing threshold, sensing threshold and impedance were (0.60±0.09)V, (16.1±3.9)mV, (662±78)Ω respectively at 3 months after operation. The patient with low left ventricular ejection fraction (LVEF) recovered to normal on the 3 rd day after LBBAP (45% vs. 57%). The LVEDD Z score decreased to (1.1±0.3) at 3 months after operation and was significantly lower than that before operation (t=2.38, P<0.05).@*Conclusions@#LBBAP in children can achieve narrow QRS pacing andphysiological pacing with stablepacing parameters. It can improve left ventricular enlargement caused by long-term bradycardia, and cardiac dysfunction and cardiac enlargement caused by long-term right ventricular apical pacing quickly and effectively.LBBAP is safe and feasible for older children in the near future. However, the long term potential risks of LBBAP need further observation and study.