Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
2.
Clin Res Cardiol ; 112(6): 834-845, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36773038

RESUMO

BACKGROUND: Sleep-disordered breathing (SDB) is prevalent in up to 50% of patients referred for atrial fibrillation (AF) catheter ablation (CA). Currently, it remains unclear how to improve pre-selection for SDB screening in patients with AF. AIM: We aimed to (1) assess the accuracy of the STOP-Bang screening questionnaire for detection of SDB within an AF population referred for CA; (2) derive a refined, AF-specific SDB score to improve pre-selection. METHODS: Consecutive AF patients referred for CA without a history of SDB and/or SDB screening were included. Patients were digitally referred to the previously implemented Virtual-SAFARI SDB screening and management pathway including a home sleep test. An apnoea-hypopnoea index (AHI) of  ≥ 15 was interpreted as moderate-to-severe SDB. Logistic regression analysis was used to assess characteristics associated with moderate-to-severe SDB to refine pre-selection for SDB screening. RESULTS: Of 206 included patients, 51% were diagnosed with moderate-to-severe SDB. The STOP-Bang questionnaire performed poorly in detecting SDB, with an area under the receiver operating characteristic curve (AUROC) of 0.647 (95% Confidence-Interval (CI) 0.573-0.721). AF-specific refinement resulted in the BOSS-GAP score. Therein, BMI with cut-off point ≥ 27 kg/m2 and previous stroke or transient ischaemic attack (TIA) were added, while tiredness and neck circumference were removed. The BOSS-GAP score performed better with an AUROC of 0.738 (95% CI 0.672-0.805) in the overall population. CONCLUSION: AF-specific refinement of the STOP-Bang questionnaire moderately improved detection of SDB in AF patients referred for CA. Whether questionnaires bring benefits for pre-selection of SDB compared to structural screening in patients with AF requires further studies. TRIAL REGISTRATION NUMBER: ISOLATION was registered NCT04342312, 13-04-2020.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Inquéritos e Questionários , Polissonografia/métodos , Curva ROC
3.
Eur J Cardiovasc Nurs ; 22(5): 498-505, 2023 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-36218087

RESUMO

AIMS: In this quality improvement project, a care pathway for patients considered for atrial fibrillation (AF) ablation was optimized with the goals to improve the patient journey and simultaneously integrate prospective data collection into the clinical process. METHODS AND RESULTS: The Lean Six Sigma approach was used to map the pre-existing process, identify constraints, and formulate countermeasures. The percentage of patients going through the full pre-ablation preparation that eventually underwent AF ablation, number of hospital visits and consultations, pathway compliance, and completeness of scientific data were measured before and after pathway optimization. Constraints in the process were (i) lack of standardized processes, (ii) inefficient use of resources, (iii) lack of multidisciplinary integration, (iv) lack of research integration, and (v) suboptimal communication. The impact of the corresponding countermeasures (defining a uniform process, incorporating 'go/no-go' moment, introducing a 'one-stop-shop', integrating prospective data collection, and improving communication) was studied for 33 patients before and 26 patients after pathway optimization. After optimization, the percentage of patients receiving a full pre-ablation preparation that eventually underwent AF ablation increased from 59% to 94% (P < 0.01). Fewer hospital visits (3.2 ± 1.2 vs. 2.3 ± 0.8, P = 0.01) and electrophysiologist consultations (1.8 ± 0.7 vs. 1.0 ± 0.3, P < 0.01) were required after pathway optimization. Pathway compliance and complete collection of scientific data increased significantly (3% vs. 73%, P < 0.01 and 15% vs. 73%, P < 0.01, respectively). CONCLUSION: The optimization project resulted in a more efficient evaluation of patients considered for AF ablation. The new more efficient process includes prospective data collection and facilitates easy conduct of research studies focused on improvements of patient outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Coleta de Dados
4.
Front Cardiovasc Med ; 9: 879139, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35879962

RESUMO

Introduction: Continuous progress in atrial fibrillation (AF) ablation techniques has led to an increasing number of procedures with improved outcome. However, about 30-50% of patients still experience recurrences within 1 year after their ablation. Comprehensive translational research approaches integrated in clinical care pathways may improve our understanding of the complex pathophysiology of AF and improve patient selection for AF ablation. Objectives: Within the "IntenSive mOlecular and eLectropathological chAracterization of patienTs undergoIng atrial fibrillatiOn ablatioN" (ISOLATION) study, we aim to identify predictors of successful AF ablation in the following domains: (1) clinical factors, (2) AF patterns, (3) anatomical characteristics, (4) electrophysiological characteristics, (5) circulating biomarkers, and (6) genetic background. Herein, the design of the ISOLATION study and the integration of all study procedures into a standardized pathway for patients undergoing AF ablation are described. Methods: ISOLATION (NCT04342312) is a two-center prospective cohort study including 650 patients undergoing AF ablation. Clinical characteristics and routine clinical test results will be collected, as well as results from the following additional diagnostics: determination of body composition, pre-procedural rhythm monitoring, extended surface electrocardiogram, biomarker testing, genetic analysis, and questionnaires. A multimodality model including a combination of established predictors and novel techniques will be developed to predict ablation success. Discussion: In this study, several domains will be examined to identify predictors of successful AF ablation. The results may be used to improve patient selection for invasive AF management and to tailor treatment decisions to individual patients.

6.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35040534

RESUMO

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
Europace ; 24(4): 565-575, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34718525

RESUMO

AIMS: In atrial fibrillation (AF) patients, untreated sleep-disordered breathing (SDB) is associated with lower success rates of rhythm control strategies and as such structured SDB testing is recommended. Herein, we describe the implementation of a virtual SDB management pathway in an AF outpatient clinic and examine the utility and feasibility of this new approach. METHODS AND RESULTS: Prospectively, consecutive AF patients accepted for AF catheter ablation procedures without previous diagnosis of SDB were digitally referred to a virtual SDB management pathway and instructed to use WatchPAT-ONE (ITAMAR) for one night. Results were automatically transferred to a virtual sleep laboratory, upon which a teleconsultation with a sleep physician was planned. Patient experience was measured using surveys. SDB testing was performed in 119 consecutive patients scheduled for AF catheter ablation procedures. The median time from digital referral to finalization of the sleep study report was 18 [11-24] days. In total, 65 patients (55%) were diagnosed with moderate-to-severe SDB. Patients with SDB were prescribed more cardiovascular drugs and had higher body mass indices (BMI, 29 ± 3.3 vs. 27 ± 4.4kg/m2, P < 0.01). Patients agreed that WatchPAT-ONE was easy to use (91%) and recommended future use of this virtual pathway in AF outpatient clinics (86%). Based on this remote SDB testing, SDB treatment was recommended in the majority of patients. CONCLUSION: This novel virtual AF management pathway allowed remote SDB testing in AF outpatient clinics with a short time to diagnosis and high patient satisfaction. Structured SDB testing results in a high detection of previously unknown SDB in AF patients scheduled for AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Síndromes da Apneia do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Polissonografia , Sono , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia
8.
J Interv Card Electrophysiol ; 64(1): 9-16, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33629193

RESUMO

BACKGROUND: Catheter ablation for persistent atrial fibrillation (persAF) is associated with less favorable outcomes than for paroxysmal AF. To improve success rates, left atrial (LA) substrate modification is frequently performed in addition to pulmonary vein isolation (PVI). The purpose of the study was to compare 4 different ablation approaches using radiofrequency catheter ablation (RFCA) or cryoballoon ablation (CB-A) for persAF and to evaluate the respective outcomes on a midterm follow-up of 12 months. METHODS: We did a propensity score-matched comparison of 30 patients undergoing PVI + LA posterior wall isolation (LAPWI) with CB-A, 30 patients who underwent PVI + linear ablation (roof and mitral lines) using RFCA, 60 patients with PVI alone using CB-A, and 60 patients who had PVI alone using RFCA. The endpoint was recurrence of documented atrial tachyarrhythmias (ATas) > 30 s at 1-year follow-up. RESULTS: After 12 months, freedom from ATas after a single procedure was 83.3% in the PVI + LAPWI group, 46.7% in the PVI + linear ablation group, 58.3% in the PVI-alone CB-A group, and 61.6% PVI-alone RFCA (p = 0.03). Moreover, freedom from ATas was significantly higher comparing the PVI + LAPWI group with each of the other groups. CONCLUSIONS: In this propensity-matched comparison of strategies for persAF, LAPW ablation in addition to PVI with CB-A seems to improve 1-year outcome in comparison to PVI + linear ablation using RFCA and to PVI alone using RFCA or CB-A. Randomized comparisons are eagerly awaited.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Pontuação de Propensão , Veias Pulmonares/cirurgia , Recidiva , Taquicardia/cirurgia , Resultado do Tratamento
9.
Europace ; 23(12): 1961-1969, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34333631

RESUMO

AIMS: At present, there are no guideline recommendations for minimally interrupted use of non-vitamin K antagonist oral anticoagulants (mi-NOAC) during catheter ablation (CA) for atrial fibrillation (AF). Current evidence is predominantly based on observational studies, with continuous use of vitamin K antagonist in the control arm. This quantitative summary reflects the first high-level evidence on contemporary regimens, with continuous NOAC use (c-NOAC) as the current gold standard. METHODS AND RESULTS: Meta-analysis (Pubmed, Embase, and Web of Science) on prospective, controlled studies comparing contemporary mi-NOAC (without bridging) with c-NOAC. Net adverse clinical events (major bleeding, thrombo-embolic events) were the primary outcome. In addition, we analysed total bleeding, minor bleeding, and silent cerebral embolism. Eight studies (six randomized, two observational) with 2168 patients were summarized. The primary endpoint occurred in 1.0% (18/1835): 1.1% (11/1005) vs. 0.8% (7/830) for the mi-NOAC and c-NOAC groups, respectively; odds ratio (OR) 1.20 [95% confidence interval (CI) 0.49-2.92, P = 0.64]. The OR for total bleeding on mi-NOAC was 1.26 (95% CI 0.97-1.63, P = 0.07). ORs for minor bleeding and silent cerebral embolism were 1.17 (95% CI 0.80-1.70, P = 0.34) and 2.62 (95% CI 0.54-12.61, P = 0.12), respectively. CONCLUSION: This synopsis provides a quantitative synthesis of high-level evidence on a contemporary strategy of mi-NOAC in CA for AF, and overall clinical outcomes were not different from continuous NOAC use. Despite preprocedural interruption, there was no sign of lower bleeding rates. Additional higher volume datasets are warranted for more precise treatment effect estimations of this everyday alternative anticoagulation strategy in AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Vitamina K
10.
Europace ; 23(2): 216-225, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33141152

RESUMO

AIMS: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. METHODS AND RESULTS: The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98-4.45) and 2.02 (95% CI 1.03-4.00) respectively. CONCLUSION: The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Países Baixos/epidemiologia , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
J Am Heart Assoc ; 9(19): e016727, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-33003984

RESUMO

Background In cardiac arrest, computerized analysis of the ventricular fibrillation (VF) waveform provides prognostic information, while its diagnostic potential is subject of study. Animal studies suggest that VF morphology is affected by prior myocardial infarction (MI), and even more by acute MI. This experimental in-human study reports on the discriminative value of VF waveform analysis to identify a prior MI. Outcomes may provide support for in-field studies on acute MI. Methods and Results We conducted a prospective registry of implantable cardioverter defibrillator recipients with defibrillation testing (2010-2014). From 12-lead surface ECG VF recordings, we calculated 10 VF waveform characteristics. First, we studied detection of prior MI with lead II, using one key VF characteristic (amplitude spectrum area [AMSA]). Subsequently, we constructed diagnostic machine learning models: model A, lead II, all VF characteristics; model B, 12-lead, AMSA only; and model C, 12-lead, all VF characteristics. Prior MI was present in 58% (119/206) of patients. The approach using the AMSA of lead II demonstrated a C-statistic of 0.61 (95% CI, 0.54-0.68). Model A performance was not significantly better: 0.66 (95% CI, 0.59-0.73), P=0.09 versus AMSA lead II. Model B yielded a higher C-statistic: 0.75 (95% CI, 0.68-0.81), P<0.001 versus AMSA lead II. Model C did not improve this further: 0.74 (95% CI, 0.67-0.80), P=0.66 versus model B. Conclusions This proof-of-concept study provides the first in-human evidence that MI detection seems feasible using VF waveform analysis. Information from multiple ECG leads rather than from multiple VF characteristics may improve diagnostic accuracy. These results require additional experimental studies and may serve as pilot data for in-field smart defibrillator studies, to try and identify acute MI in the earliest stages of cardiac arrest.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Parada Cardíaca , Processamento de Imagem Assistida por Computador/métodos , Infarto do Miocárdio , Fibrilação Ventricular , Idoso , Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica/instrumentação , Eletrocardiografia/métodos , Feminino , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Países Baixos , Prognóstico , Estudo de Prova de Conceito , Sistema de Registros , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia
12.
J Am Coll Cardiol ; 75(4): 347-359, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-32000945

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is usually performed by biventricular (BiV) pacing. Previously, feasibility of transvenous implantation of a lead at the left ventricular (LV) endocardial side of the interventricular septum, referred to as LV septal (LVs) pacing, was demonstrated. OBJECTIVES: The authors sought to compare the acute electrophysiological and hemodynamic effects of LVs with BiV and His bundle (HB) pacing in CRT patients. METHODS: Temporary LVs pacing (transaortic approach) alone or in combination with right ventricular (RV) (LVs+RV), BiV, and HB pacing was performed in 27 patients undergoing CRT implantation. Electrophysiological changes were assessed using electrocardiography (QRS duration), vectorcardiography (QRS area), and multielectrode body surface mapping (standard deviation of activation times [SDAT]). Hemodynamic changes were assessed as the first derivative of LV pressure (LVdP/dtmax). RESULTS: As compared with baseline, LVs pacing resulted in a larger reduction in QRS area (to 73 ± 22 µVs) and SDAT (to 26 ± 7 ms) than BiV (to 93 ± 26 µVs and 31 ± 7 ms; both p < 0.05) and LVs+RV pacing (to 108 ± 37 µVs; p < 0.05; and 29 ± 8 ms; p = 0.05). The increase in LVdP/dtmax was similar during LVs and BiV pacing (17 ± 10% vs. 17 ± 9%, respectively) and larger than during LVs+RV pacing (11 ± 9%; p < 0.05). There were no significant differences between basal, mid-, or apical LVs levels in LVdP/dtmax and SDAT. In a subgroup of 16 patients, changes in QRS area, SDAT, and LVdP/dtmax were comparable between LVs and HB pacing. CONCLUSIONS: LVs pacing provides short-term hemodynamic improvement and electrical resynchronization that is at least as good as during BiV and possibly HB pacing. These results indicate that LVs pacing may serve as a valuable alternative for CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Fenômenos Eletrofisiológicos , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Idoso , Bloqueio de Ramo/terapia , Eletrocardiografia , Eletrodos , Feminino , Fluoroscopia , Insuficiência Cardíaca/fisiopatologia , Septos Cardíacos/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Função Ventricular Esquerda
13.
J Interv Card Electrophysiol ; 54(1): 17-24, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30090996

RESUMO

PURPOSE: Currently, information on the optimal approach of redo procedures for paroxysmal atrial fibrillation (PAF) is limited. Radiofrequency ablation is the preferred technique, with reported success rates of 50-70% at 1-2 years, whereas only few reports exist on redo cryoballoon (CB) ablations. We describe outcomes on a systematic approach of repeat procedures with a second-generation cryoballoon (CB-2) after a successful index CB ablation. METHODS: Cohort study of 40 consecutive patients with recurrent PAF (55% male), median CHA2DS2-VASc score 1 (IQR 0-3). Per protocol, a staged variable balloon size strategy was followed with a different balloon size during the redo as compared to the index procedure. Minimal follow-up was 12 months (median 17 months [IQR 14-39]). RESULTS: Overall, 120 pulmonary veins (PVs) (75%) showed chronic isolation: 64% (41/64) for first-generation cryoballoon (CB-1) and 82% (79/96) for CB-2 index procedures, respectively (p = 0.01). The overall mean number of reconnected PVs per patient was 1.0 (40/40): 1.4 for CB-1 and 0.7 for CB-2 index procedures (p = 0.008). Phrenic nerve palsies (n = 7) resolved before the end of the procedure. At 1 year, 70% of patients were free of recurrent AF. In multivariate analysis, the only independent predictor of recurrence was the number of prior cardioversions. CONCLUSIONS: A systematic approach of repeat procedures with a CB-2 using a different balloon size than during the index CB ablation is safe, with acceptable 1-year outcomes. Future comparative studies on the optimal redo technique and approach are warranted to further improve rhythm control in AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Estudos de Coortes , Criocirurgia/instrumentação , Criocirurgia/mortalidade , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos , Recidiva , Reoperação/métodos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
14.
Resuscitation ; 115: 82-89, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28363820

RESUMO

BACKGROUND: Despite a promising association between VF waveform characteristics and prognosis after resuscitation, studies with VF-guided treatment have so far not improved outcomes. While driven by the idea that the VF waveform reflects arrest duration, increasing evidence suggests that pre-existent disease-related changes of the myocardium affect ECG-characteristics of VF as well. In this context, we studied the impact of the left ventricular (LV) diameter and mass. METHODS: Cohort of 193 ICD-patients with defibrillation testing at the Radboudumc (2010-2014). Surface ECG-recordings (leads I,II,aVF,V1,V3,V6) were analysed to study amplitude and frequency characteristics of the induced VF. Both for LV diameter and mass, patients were categorised in two groups, using echocardiographic data (ASE-guidelines). RESULTS: In all ECG-leads, dominant and median frequencies were significantly lower in patients with (n=40) than in patients without (n=151) an increased LV diameter. The mean amplitude and amplitude spectrum area (AMSA) did not differ. In contrast, we observed no differences in frequency characteristics in relation to the LV mass, whereas mean amplitude (I,aVF,V3) and AMSA (I,V3) were significantly higher in patients with (n=57) than in patients without (n=120) an increased LV mass. CONCLUSIONS: Frequency characteristics of VF were consistently lower in case of an increased LV diameter. Whereas LV mass does not affect the frequency of the VF waveform, amplitudes seem higher with increasing mass. These findings add to the current knowledge of factors that modulate VF characteristics of the surface ECG and provide insight into factors which may be accounted for in future studies on VF-guided resuscitative interventions.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca/etiologia , Ventrículos do Coração/patologia , Infarto do Miocárdio/complicações , Fibrilação Ventricular/terapia , Idoso , Reanimação Cardiopulmonar , Estudos de Coortes , Cardioversão Elétrica , Eletrocardiografia , Feminino , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Tamanho do Órgão , Fibrilação Ventricular/fisiopatologia
15.
J Cardiovasc Electrophysiol ; 27(5): 587-93, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26824826

RESUMO

INTRODUCTION: In view of the shift from routine toward no or selective defibrillation testing, optimization of the current risk stratification for inadequate defibrillation safety margins (DSMs) could improve individualized testing decisions. Given the pathophysiological differences in myocardial substrate between ischemic and nonischemic heart disease (IHD/non-IHD) and the accompanying differences in clinical characteristics, we studied inadequate DSMs and their predictors in relation to the underlying etiology. METHODS AND RESULTS: Cohort of routine defibrillation tests (n = 785) after first implantable cardioverter defibrillator (ICD)-implantations at the Radboud UMC (2005-2014). A defibrillation threshold >25 J was regarded as an inadequate DSM. In total, 4.3% of patients had an inadequate DSM; in IHD 2.5% versus 7.3% in non-IHD (P = 0.002). We identified a group of non-IHD patients at high risk (13-42% inadequate DSM); the remainder of the cohort (>70%) had a risk of only 2% (C-statistic entire cohort 0.74; C-statistic non-IHD 0.82). This was based upon two identified interaction terms: (1) non-IHD and age (aOR 0.94 [95% CI 0.91-0.97]); (2) non-IHD and the indexed left ventricular (LV) internal diastolic diameter (aOR 3.50 [95% CI 2.10-5.82]). CONCLUSION: The present study on risk stratification for an inadequate DSM not only confirms the importance of making a distinction between IHD and non-IHD, but also shows that risk factors in an entire cohort (LV dilatation, age) may only apply to a subgroup (non-IHD). Appreciation of this concept could favorably affect current risk stratification. If confirmed, our approach may be used to optimize individualized testing decisions in an upcoming era of non-routine testing.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Segurança de Equipamentos , Isquemia Miocárdica/complicações , Segurança do Paciente , Adulto , Fatores Etários , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Distribuição de Qui-Quadrado , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Hipertrofia Ventricular Esquerda/complicações , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Países Baixos , Razão de Chances , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Resuscitation ; 96: 239-45, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26325098

RESUMO

BACKGROUND: Characteristics of the ventricular fibrillation (VF) waveform reflect arrest duration and have been incorporated in studies on algorithms to guide resuscitative interventions. Findings in animals indicate that VF characteristics are also affected by the presence of a previous myocardial infarction (MI). As studies in humans are scarce, we assessed the impact of a previous MI on VF characteristics in ICD-patients. METHODS: Prospective cohort of ICD-patients (n=190) with defibrillation testing at the Radboudumc (2010-2013). VF characteristics of the 12-lead surface ECG were compared between three groups: patients without a history of MI (n=88), with a previous anterior (n=47) and a previous inferior MI (n=55). RESULTS: As compared to each of the other groups, the mean amplitude and amplitude spectrum area were lower, for an anterior MI in lead V3 and for an inferior MI in leads II and aVF. Across the three groups, the bandwidth was broader in the leads corresponding with the infarct localisation. In contrast, the dominant and median frequencies only differed between previous anterior MI and no history of MI, being lower in the former. CONCLUSIONS: The VF waveform is affected by the presence of a previous MI. Amplitude-related measures were lower and VF was less organised in the ECG-lead(s) adjacent to the area of infarction. Although VF characteristics of the surface ECG have so far primarily been considered a proxy for arrest duration and metabolic state, our findings question this paradigm and may provide additional insights into the future potential of VF-guided resuscitative interventions.


Assuntos
Desfibriladores Implantáveis , Eletromiografia/métodos , Parada Cardíaca/etiologia , Frequência Cardíaca/fisiologia , Infarto do Miocárdio/complicações , Fibrilação Ventricular/fisiopatologia , Idoso , Algoritmos , Feminino , Seguimentos , Parada Cardíaca/epidemiologia , Parada Cardíaca/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Países Baixos/epidemiologia , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fibrilação Ventricular/complicações , Fibrilação Ventricular/terapia
17.
Resuscitation ; 86: 95-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25449343

RESUMO

BACKGROUND: Ventricular fibrillation (VF) waveform characteristics are associated with cardiac arrest duration and defibrillation success. Recent animal studies found that VF characteristics and shock success also depend on the presence of myocardial infarction (MI). In patients, VF induction after implantable cardioverter defibrillator (ICD) implantation offers a unique setting to study early VF characteristics: we studied the relation with cardiac disease--either presence or absence of a previous MI--and with shock success. METHODS: Retrospective cohort study of ICD-patients who underwent defibrillation testing, 117 (63%) with and 69 (37%) without a previous MI. Intracardiac recordings of induced VF were analysed using Fourier analysis. RESULTS: In previous MI-patients, the fundamental frequency and organisation index of the VF signal were significantly lower as compared with patients without a previous MI: 4.9 Hz ± 0.6 vs. 5.2 Hz ± 0.6 (p = 0.005) and 56% ± 10 vs. 60% ± 9 (p = 0.001), respectively. The median frequency was not different (p = 0.25). We found no association between VF characteristics and ICD shock success. CONCLUSIONS: In analogy with observations in animals, we found that a history of a previous MI was associated with slower and less organised VF. In our cohort of ICD-patients, early VF waveform characteristics were not associated with shock outcomes. Further study is warranted to determine to what extent VF characteristics are influenced by the underlying aetiology on the one hand, and time delay on the other. These findings could improve insight into the potential value of VF analysis to guide shock delivery.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia , Estudos de Coortes , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Indução de Remissão , Estudos Retrospectivos , Fibrilação Ventricular/etiologia
18.
J Interv Card Electrophysiol ; 38(2): 85-93, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24026967

RESUMO

PURPOSE: This study was conducted to investigate the degree of fibrosis in atrial appendages of patients with and without atrial fibrillation (AF) undergoing cardiac surgery. In addition, we hypothesized that areas of atrial fibrosis can be identified by electrogram fractionation and low voltage for potential ablation therapy. METHODS: Interstitial fibrosis from right (RAA) and/or left atrial appendages (LAA) was studied in patients with sinus rhythm (SR, n = 8), paroxysmal (n = 21), and persistent AF (n = 20) undergoing coronary artery bypass and/or aortic or mitral valve surgery. Atrial fibrosis quantification was performed with Masson trichrome staining. Intraoperative bipolar epicardial electrophysiological measurements were performed to correlate fibrosis to electrogram fractionation, voltage, and AF cycle length. RESULTS: The average degree of fibrosis was 11.2 ± 7.2 % in the LAA and 22.8 ± 7.6 % in the RAA (p < 0.001). Fibrosis was not significantly higher in paroxysmal AF patients compared to SR subjects (18.2 ± 8.7 versus 20.7 ± 5.3 %). Persistent AF patients had a higher degree of LAA and RAA fibrosis compared to paroxysmal AF patients (LAA 14.6 ± 8.7 versus 8.6 ± 4.7 %, p = 0.02, and RAA 28.2 ± 7.9 versus 18.2 ± 8.7 %, respectively, p = 0.04). The left atrial end diastolic volume index was higher in persistent AF patients compared to SR controls (38.3 ± 16.4 and 28 ± 11 ml/m(2), respectively, p = 0.04). No correlation between atrial fibrosis and electrogram fractionation or voltage was found. CONCLUSION: Patients with structural heart disease undergoing cardiac surgery have more fibrosis in the RAA than in the LAA. Furthermore, RAA fibrosis is increased in persistent AF but not paroxysmal AF patients compared to control subjects. Electrogram fractionation and low voltage did not provide accurate identification of the fibrotic substrate.


Assuntos
Apêndice Atrial/patologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Doença da Artéria Coronariana/complicações , Eletrocardiografia/métodos , Doenças das Valvas Cardíacas/complicações , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Fibrose , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...