1.
Materials (Basel) ; 15(19)2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36234309

RESUMO

Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5−55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials.

2.
Materials (Basel) ; 14(10)2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34069551

RESUMO

BACKGROUND: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. PURPOSE: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. MATERIALS AND METHODS: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A-D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%. RESULTS: The mean gap size ranged from 84 to 132 µm (SD 43-71 µm). The CAD/CAM systems showed significant variance (p < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks (p < 0.001). CONCLUSIONS: The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.

3.
Int J Esthet Dent ; 13(1): 110-119, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29379907

RESUMO

AIM: To optimize the esthetics of ceramic restorations, it is important to determine accurately the effects of various parameters on the final color of the restoration. However, there is a lack of information on what determines the color of translucent feldspathic veneers formed using ceramics such as Vita Mark II. The aim of this study was to evaluate the effects of the ceramic layer thickness, cement color, and abutment tooth color on the color of the feldspathic ceramic veneer restoration. MATERIAL AND METHODS: A total of 30 all-ceramic monolithic veneers (Vita Mark II) were fabricated using a CAD/CAM system. The crowns were divided into three groups of differing ceramic thickness (0.4-, 0.7-, and 1.0-mm thick). Each type of crown was seated on six different-colored abutment teeth (1M1 [reference], 1M2, 2M2, 3M2, 4M2, and 5M2) using seven different try-in paste colors. The color of the resulting restoration was evaluated using spectrophotometry with a spot-measurement device (Vita Easyshade Advance 4.0). Color data are expressed in CIE L*a*b* system coordinates, and color differences ΔE relative to the reference tooth were calculated and analyzed using one-way analysis of variance (ANOVA) with the Bonferroni post hoc test at α = 0.05. RESULTS: The color difference ΔE of the feldspathic all-ceramic veneer system was significantly affected by the thickness of the ceramic layer, the cement color, and the abutment tooth color (P < 0.05). The smallest values of ΔE compared with the reference color were found when try-in pastes shade -3 was used. As the thickness of the ceramic layer increased, a significant decrease in ΔE was found. As the color of the abutment tooth varied from light to dark, a significant increase was found in ΔE. CONCLUSION: The thickness of the ceramic layer, the cement color, and the abutment tooth color significantly affected the color of the resulting CAD/CAM feldspathic ceramic veneer restoration.


Assuntos
Cor , Coroas , Dente Suporte , Porcelana Dentária/química , Facetas Dentárias , Estética Dentária , Silicatos de Alumínio , Desenho Assistido por Computador , Teste de Materiais , Compostos de Potássio
4.
J Esthet Restor Dent ; 29(5): 303-308, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28742283

RESUMO

OBJECTIVE: The aim of this investigation was to evaluate intra-rater and inter-rater reliability of visual and instrumental shade matching. MATERIALS AND METHODS: Forty individuals with normal color perception participated in this study. The right maxillary central incisor of a teaching model was prepared and restored with 10 feldspathic all-ceramic crowns of different shades. A shade matching session consisted of the observer (rater) visually selecting the best match by using VITA classical A1-D4 (VC) and VITA Toothguide 3D Master (3D) shade guides and the VITA Easyshade Advance intraoral spectrophotometer (ES) to obtain both VC and 3D matches. Three shade matching sessions were held with 4 to 6 weeks between sessions. Intra-rater reliability was assessed based on the percentage of agreement for the three sessions for the same observer, whereas the inter-rater reliability was calculated as mean percentage of agreement between different observers. The Fleiss' Kappa statistical analysis was used to evaluate visual inter-rater reliability. RESULTS: The mean intra-rater reliability for the visual shade selection was 64(11) for VC and 48(10) for 3D. The corresponding ES values were 96(4) for both VC and 3D. The percentages of observers who matched the same shade with VC and 3D were 55(10) and 43(12), respectively, while corresponding ES values were 88(8) for VC and 92(4) for 3D. CONCLUSIONS: The results for visual shade matching exhibited a high to moderate level of inconsistency for both intra-rater and inter-rater comparisons. The VITA Easyshade Advance intraoral spectrophotometer exhibited significantly better reliability compared with visual shade selection. CLINICAL SIGNIFICANCE: This study evaluates the ability of observers to consistently match the same shade visually and with a dental spectrophotometer in different sessions. The intra-rater and inter-rater reliability (agreement of repeated shade matching) of visual and instrumental tooth color matching strongly suggest the use of color matching instruments as a supplementary tool in everyday dental practice to enhance the esthetic outcome.


Assuntos
Percepção de Cores , Coroas , Estética Dentária , Incisivo/anatomia & histologia , Pigmentação em Prótese , Adulto , Planejamento de Prótese Dentária , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Espectrofotometria/instrumentação
5.
Int J Oral Maxillofac Implants ; 31(2): 304-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27004277

RESUMO

PURPOSE: The fracture strengths of all-ceramic crowns cemented on titanium implant abutments may vary depending on crown materials and luting agents. The purpose of this study was to examine differences in fracture strength among crowns cemented on implant abutments using crowns made of seven different monolithic ceramic materials and five different luting agents. MATERIALS AND METHODS: In total, 525 crowns (75 each of Vita Mark II, feldspathic ceramic [FSC]; Ivoclar Empress CAD, leucite-reinforced glass ceramic [LrGC]; Ivoclar e.max CAD, lithium disilicate [LiDS]; Vita Suprinity, presintered zirconia-reinforced lithium silicate ceramic [PSZirLS]; Vita Enamic, polymer-reinforced fine-structure feldspathic ceramic [PolyFSP], Lava Ultimate; resin nanoceramic [ResNC], Celtra Duo; fully crystallized zirconia-reinforced lithium silicate [FcZirLS]) were milled using a CAD/CAM system. The inner surfaces of the crowns were etched and silanized. Titanium implant abutments were fixed on implant analogs, and airborne-particle abrasion was used on their exterior specific adhesion surfaces (Al2O3, 50 µm). Then, the abutments were degreased and silanized. The crowns were cemented on the implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, GC FujiCEM, Panavia 2.0). After thermocycling for 5,000 cycles (5 to 55°C, 30 seconds dwell time), the crowns were subjected to fracture strength testing under static load using a universal testing machine. Statistical analyses were performed using analysis of variance (α = .0002) and the Bonferroni correction. RESULTS: No significant difference among the luting agents was found using the different all-ceramic materials. Ceramic materials LiDS, PSZirLS, PolyFSP, and ResNC showed significantly higher fracture strength values compared with FSC, FcZirLS, and LrGC. The PSZirLS especially showed significantly better results. CONCLUSION: Within the limitations of this study, fracture strength was not differentially affected by the various luting agents. However, the fracture strength was significantly higher for PSZirLS, PolyFSP, ResNC, and LiDS ceramics than for the FSP, LrGC, and the FcZirLS ceramic with all luting agents tested.


Assuntos
Coroas , Dente Suporte , Materiais Dentários/química , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Titânio/química , Silicatos de Alumínio/química , Cerâmica/química , Desenho Assistido por Computador , Implantes Dentários , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Nanoestruturas/química , Polímeros/química , Compostos de Potássio/química , Cimentos de Resina/química , Estresse Mecânico , Zircônio/química
6.
Dent Mater J ; 35(1): 63-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26830824

RESUMO

The aim of this study was to compare the agreement rate (%) and color difference (ΔE*ab) of three dental color-measuring devices, with the visual shade identification. The tooth color were determined by two operators, which were advised to select a VITA classic shade tab in each other's agreement. The Shadepilot (SP), CrystalEye (CE) and ShadeVision (SV) were used to measure tooth color. Statistically analyses include agreement rate (%), color difference (ΔE*ab), McNemar test (p=0.05), Student's t-test (p=0.05) and Bland Altman scatterplots. The SP had an agreement of 56.3% with the visual shade determination, the CE 49.0% and SV 51.3%. ΔE*ab of the visually and instrumentally selected shade tabs and natural teeth were frequently above the threshold for acceptability. Comparing both methods, for SP ΔE*ab values differ in a range of clinical acceptability.


Assuntos
Colorimetria/instrumentação , Planejamento de Prótese Dentária/instrumentação , Incisivo/anatomia & histologia , Pigmentação em Prótese/instrumentação , Adulto , Calibragem , Feminino , Humanos , Masculino , Fibras Ópticas , Espectrofotometria/instrumentação
7.
Clin Implant Dent Relat Res ; 17 Suppl 2: e542-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25536516

RESUMO

BACKGROUND: To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. PURPOSE: This retrospective study aimed to assess the suitability of three stability parameters - namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values - as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. MATERIALS AND METHODS: Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediately loaded using temporary fixed dentures. The IT results, PT values, and ISQ results were recorded. Receiver operating characteristic analysis was performed to assess the quality of each parameter as a diagnostic test. RESULTS: After a 3-month observation period, 11 implants in four patients were not osseointegrated. The IT and ISQ (IT 25.0 ± 12.5 Ncm and 8.4 ± 2.3 Ncm; PT -1.5 ± 3.0 and +2.7 ± 3.0; and ISQ 62.6 ± 6.7 and 54.7 ± 6.2) differed significantly between the osseointegrated and failed implants (p < .005). The IT showed the greatest specificity at a sensitivity of 1 and the greatest area under the curve (AUC; 0.929), followed by the PT value (AUC = 0.836) and ISQ (AUC = 0.811). CONCLUSIONS: Among the intraoperative parameters analyzed, IT showed the highest specificity at a high sensitivity of 1. Therefore, the IT can be considered the most valid prognostic factor for osseointegration of immediately loaded splinted dental implants.


Assuntos
Implantes Dentários/normas , Carga Imediata em Implante Dentário/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Implantação Dentária Endóssea/normas , Retenção em Prótese Dentária , Falha de Restauração Dentária/estatística & dados numéricos , Análise do Estresse Dentário , Feminino , Humanos , Carga Imediata em Implante Dentário/estatística & dados numéricos , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Torque
8.
Int J Comput Dent ; 17(2): 135-44, 2014.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-25098161

RESUMO

The aim of the study was to determine the retentive strength of monolithic all-ceramic crowns cemented on titanium implant abutments. 225 crowns (75 crowns each of Mark II, Empress CAD, and e.max CAD) were milled using a CAD/ CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling, the crowns were removed using a universal testing machine. The location of luting agent residue on the abutment and inner crown surfaces was evaluated. Statistical analysis was performed using ANOVA with the Bonferroni correction. In comparing the luting agents, no significant difference was found between Vita Mark II and Empress CAD. For e.max CAD, the luting agent RelyX Unicem had a significantly higher mean retentive strength than did Multilink Implant (p = 0.003) or Panavia 2.0 (p = 0.001). In comparing the ceramic materials, e.max CAD showed significantly higher pull-off strengths than the other two ceramic materials when the luting agents RelyX Unicem and Fujicem were used (all p < 0.001). The residues of nearly all luting agents were located entirely or almost entirely (75%-100%) on the inner crown surfaces of all ceramic materials, except for the luting agent GC Fujicem, which left more luting agent residue (0%-75%) on the abutment surfaces of all ceramic materials. In comparing the five luting agents, significant differences in the resulting retentive strength were only found for the ceramic material e.max CAD. The other ceramic materials did not show significant differences in retentive strength, independent of the luting agent.


Assuntos
Cerâmica/química , Coroas , Porcelana Dentária/química , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Silicatos de Alumínio/química , Cimentação/métodos , Desenho Assistido por Computador , Projeto do Implante Dentário-Pivô , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Estresse Mecânico , Temperatura , Fatores de Tempo , Titânio/química
9.
Eur J Esthet Dent ; 7(3): 324-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22908079

RESUMO

OBJECTIVES: This in vitro study evaluated the accordance of dental color measurement devices with a Commission Internationale de l'Eclairage (CIE)-compliant reference system, by comparing the CIE lightness, chroma, and hue (L*C*h°) color coordinates of ceramic samples. METHODS: Four color measurement devices: Vita Easyshade® Advance (A); DeguDent Shadepilot™ (B); X-Rite® Shadevision (C); and Crystaleye Olympus (D), were compared with a CIE-compliant reference system by recording the L*C*h° color coordinates of ceramic samples matching the tooth colors of the Vita Linearguide 3D-Master®, under standardized test conditions. Differences between regression lines for the dental color measurement device data and regression lines for the CIE-compliant reference system data were evaluated. RESULTS: All devices offered high intraclass correlation coefficients (0.9771- 0.9999) for the L*C*h° color coordinates. The regression lines of the L* and C* coordinates for device A were steeper than those of the CIE-compliant reference system; the regression lines for devices B, C, and D were nearly parallel to those of the reference system, but with an offset. The regression lines of the h° coordinates for all devices were almost parallel to those of the reference system, with slopes near 1. Excluding the L* and h° coordinate measurements of device A, the measurements with the devices exhibited deviations from the reference system that were greater than those expected by chance (P < 0.0002). CONCLUSIONS: The dental color measurement devices assessed here offered excellent reproducibility, but showed significant deviations from the CIE-compliant reference system regarding the L*C*h° color coordinates.


Assuntos
Colorimetria/instrumentação , Planejamento de Prótese Dentária/normas , Pigmentação em Prótese/normas , Análise de Variância , Porcelana Dentária , Humanos , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Espectrofotometria/instrumentação