Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Heart Rhythm O2 ; 5(6): 357-364, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38984366

RESUMO

Background: Traditional right atrial appendage (RAA) pacing accentuates conduction disturbances as opposed to Bachmann bundle pacing (BBP). Objective: The purpose of this study was to evaluate the feasibility, efficacy, and safety of routine anatomically guided high right atrial septal (HRAS) pacing with activation of Bachmann bundle combined with routine left bundle branch area pacing (LBBAP). Methods: This retrospective single-center study included 96 consecutive patients who underwent 1 of 2 strategies: physiological pacing (PP) (n = 32) with HRAS and LBBAP leads and conventional pacing (CP) (n = 64) with traditional RAA and right ventricular apical leads. Baseline characteristics, sensing, pacing thresholds, and impedances were recorded at implantation and follow-up. Results: The PP and CP cohorts were of similar age (74.2 ± 13.8 years vs 73.9 ± 9.9 years) and sex (28.1% vs 40.6% female). There were no differences in procedural time (95.0 ± 31.4 minutes vs 86.5 ± 33.3 minutes; P = .19) or fluoroscopy time (12.1 ± 4.5 minutes vs 12.3 ± 13.5 minutes; P = .89) between cohorts. After excluding patients who received >2 leads, these parameters became significantly shorter in the CP cohort. The PP cohort exhibited higher atrial pacing thresholds (1.5 ± 1.1 mV vs 0.8 ± 0.3 mV; P <.001) and lower p waves (1.8 ± 0.8 mV vs 3.8 ± 2.3 mV; P <.001) at implantation and at follow-up. In the PP cohort, 72% of implants met criteria for BBP; of the ventricular leads, 94% demonstrated evidence of LBBAP. One lead-related complication occurred in each cohort. Conclusion: Routine placement of leads in the HRAS is a feasible and safe alternative to standard RAA pacing, allowing for BBP in 72% of patients. HRAS pacing can be combined with LBBAP as a routine strategy.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38845147

RESUMO

INTRODUCTION: Prior studies have indicated that the frequency of premature ventricular complexes (PVC) increases after catheter ablation for atrial fibrillation (AF). However, these studies have primarily focused on patients whose PVC burden increased rather than including the full spectrum of outcomes. METHODS AND RESULTS: We performed a single-center retrospective cohort study of consecutive patients who underwent first-time AF ablation from 1/2018 to 12/2022 for paroxysmal or persistent AF and had both preablation and postablation rhythm monitoring within 6 months of the procedure. Patients were excluded if they had prior AF or PVC ablation or were prescribed a class I or III antiarrhythmic medication. Among 2945 patients who underwent AF ablation during the study period, 130 patients underwent first-time AF ablation and received both pre and post ambulatory monitoring. The median PVC burden before ablation was <1%. Most patients (63%) had no change in PVC burden after AF ablation compared with preablation, and patients who had an increase in PVC burden were offset by those with reductions in PVCs. A paired analysis pre- and post-AF ablation showed no significant change in PVC burden (p = .495). CONCLUSION: Although an elevated PVC burden after AF ablation may be seen clinically, the majority of patients have no change in burden. Studies that suggest an increase in PVC burden after AF ablation may suffer from incomplete sample selection and thus omit the important effect of regression to the mean.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38869507

RESUMO

BACKGROUND: Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a nonthermal ablation modality, was noninferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects. OBJECTIVES: This study sought to compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA vs thermal ablation. METHODS: ADVENT (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation) was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead electrocardiogram, whereas follow-up HRs, as well as HRV (standard deviation of all normal to normal RR intervals, standard deviation of 5-minute average RR intervals) metrics, were derived from 72-hour Holter monitors at 6 and 12 months. RESULTS: This study included 379 paroxysmal AF patients undergoing PFA (n = 194) or thermal ablation (n = 185; n = 102 RF, n = 83 CB) completing 6- and 12-month Holter monitoring. Compared with PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs 5.9 beats/min; P = 0.02) and 12 months (ΔHR; 8.8 vs 5.2 beats/min; P = 0.03). This increase in HR at 6 and 12 months was similar between CB and RF (P = 0.94 and 0.83, respectively). HRV, both standard deviation of all normal to normal RR intervals and standard deviation of 5-minute average RR intervals, were significantly lower at both 6 and 12 months after thermal ablation compared with PFA (P < 0.01). CONCLUSIONS: PFA's effect on the autonomic nervous system was attenuated compared with thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.

4.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38752906

RESUMO

BACKGROUND: Rapid technologic development and expansion of procedural expertise have led to widespread proliferation of catheter-based electrophysiology procedures. It is unclear whether these advances come at cost to patient safety. OBJECTIVE: This meta-analysis aimed to assess complication rates after modern electrophysiology procedures during the lifetime of the procedures. METHODS: A comprehensive search was performed to identify relevant data published before May 30, 2023. Studies were included if they met the following inclusion criteria: prospective trials or registries, including comprehensive complications data; and patients undergoing atrial fibrillation ablation, ventricular tachyarrhythmia ablation, leadless cardiac pacemaker implantation, and percutaneous left atrial appendage occlusion. Pooled incidences of procedure-related complications were individually assessed by random effects models to account for heterogeneity. Temporal trends in complications were investigated by clustering trials by publication year (2000-2018 vs 2019-2023). RESULTS: A total of 174 studies (43,914 patients) met criteria for analysis: 126 studies of atrial fibrillation ablation (n = 24,057), 25 studies of ventricular tachyarrhythmia ablation (n = 1781), 21 studies of leadless cardiac pacemaker (n = 8896), and 18 studies of left atrial appendage occlusion (n = 9180). The pooled incidences of serious procedure-related complications (3.49% [2000-2018] vs 3.05% [2019-2023]; P < .001), procedure-related stroke (0.46% vs 0.28%; P = .002), pericardial effusion requiring intervention (1.02% vs 0.83%; P = .037), and procedure-related death (0.15% vs 0.06%; P = .003) significantly decreased over time. However, there was no significant difference in the incidence of vascular complications over time (1.86% vs 1.88%; P = .888). CONCLUSION: Despite an increase in cardiac electrophysiology procedures, procedural safety has improved over time.

5.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305503

RESUMO

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Veias Pulmonares/cirurgia , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Método Simples-Cego , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia
6.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37634148

RESUMO

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/classificação , Fibrilação Atrial/cirurgia , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva , Método Simples-Cego , Taquicardia/etiologia , Resultado do Tratamento
7.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1437-1451, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37480862

RESUMO

BACKGROUND: Premature ventricular complexes (PVCs) are prevalent and, although often benign, they may lead to PVC-induced cardiomyopathy. We created a deep-learning algorithm to predict left ventricular ejection fraction (LVEF) reduction in patients with PVCs from a 12-lead electrocardiogram (ECG). OBJECTIVES: This study aims to assess a deep-learning model to predict cardiomyopathy among patients with PVCs. METHODS: We used electronic medical records from 5 hospitals and identified ECGs from adults with documented PVCs. Internal training and testing were performed at one hospital. External validation was performed with the others. The primary outcome was first diagnosis of LVEF ≤40% within 6 months. The dataset included 383,514 ECGs, of which 14,241 remained for analysis. We analyzed area under the receiver operating curves and explainability plots for representative patients, algorithm prediction, PVC burden, and demographics in a multivariable Cox model to assess independent predictors for cardiomyopathy. RESULTS: Among the 14,241-patient cohort (age 67.6 ± 14.8 years; female 43.8%; White 29.5%, Black 8.6%, Hispanic 6.5%, Asian 2.2%), 22.9% experienced reductions in LVEF to ≤40% within 6 months. The model predicted reductions in LVEF to ≤40% with area under the receiver operating curve of 0.79 (95% CI: 0.77-0.81). The gradient weighted class activation map explainability framework highlighted the sinus rhythm QRS complex-ST segment. In patients who underwent successful PVC ablation there was a post-ablation improvement in LVEF with resolution of cardiomyopathy in most (89%) patients. CONCLUSIONS: Deep-learning on the 12-lead ECG alone can accurately predict new-onset cardiomyopathy in patients with PVCs independent of PVC burden. Model prediction performed well across sex and race, relying on the QRS complex/ST-segment in sinus rhythm, not PVC morphology.


Assuntos
Cardiomiopatias , Aprendizado Profundo , Complexos Ventriculares Prematuros , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Volume Sistólico , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Algoritmos , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Eletrocardiografia
8.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1804-1815, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354170

RESUMO

BACKGROUND: Interatrial block (IAB) is associated with thromboembolism and atrial arrhythmias. However, prior studies included small patient cohorts so it remains unclear whether IAB predicts adverse outcomes particularly in context of atrial fibrillation (AF)/atrial flutter (AFL). OBJECTIVES: This study sought to determine whether IAB portends increased stroke risk in a large cohort in the presence or absence of AFAF/AFL. METHODS: We performed a 5-center retrospective analysis of 4,837,989 electrocardiograms (ECGs) from 1,228,291 patients. IAB was defined as P-wave duration ≥120 ms in leads II, III, or aVF. Measurements were extracted as .XML files. After excluding patients with prior AF/AFL, 1,825,958 ECGs from 458,994 patients remained. Outcomes were analyzed using restricted mean survival time analysis and restricted mean time lost. RESULTS: There were 86,317 patients with IAB and 355,032 patients without IAB. IAB prevalence in the cohort was 19.6% and was most common in Black (26.1%), White (20.9%), and Hispanic (18.5%) patients and least prevalent in Native Americans (9.2%). IAB was independently associated with increased stroke probability (restricted mean time lost ratio coefficient [RMTLRC]: 1.43; 95% CI: 1.35-1.51; tau = 1,895), mortality (RMTLRC: 1.14; 95% CI: 1.07-1.21; tau = 1,924), heart failure (RMTLRC: 1.94; 95% CI: 1.83-2.04; tau = 1,921), systemic thromboembolism (RMTLRC: 1.62; 95% CI: 1.53-1.71; tau = 1,897), and incident AF/AFL (RMTLRC: 1.16; 95% CI: 1.10-1.22; tau = 1,888). IAB was not associated with stroke in patients with pre-existing AF/AFL. CONCLUSIONS: IAB is independently associated with stroke in patients with no history of AF/AFL even after adjustment for incident AF/AFL and CHA2DS2-VASc score. Patients are at increased risk of stroke even when AF/AFL is not identified.


Assuntos
Fibrilação Atrial , Flutter Atrial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Bloqueio Interatrial/complicações , Bloqueio Interatrial/epidemiologia , Estudos Retrospectivos , Eletrocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Flutter Atrial/complicações , Flutter Atrial/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia
9.
J Cardiovasc Electrophysiol ; 34(5): 1277-1285, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36950852

RESUMO

INTRODUCTION: Multiple randomized controlled trials have demonstrated sodium-glucose cotransporter-2 inhibitors (SGLT2i) decrease the composite endpoint of cardiovascular death or heart failure hospitalizations in all heart failure patients. It is uncertain whether SGLT2i impacts the risk of sudden cardiac death in patients with heart failure. METHODS: A comprehensive search was performed to identify relevant data published before August 28, 2022. Trials were included if: (1) all patients had clinical heart failure (2) SGLT2i and placebo were compared (3) all patients received conventional medical therapy and (4) reported outcomes of interest (sudden cardiac death [SCD], ventricular arrhythmias, atrial arrhythmias). RESULTS: SCD was reported in seven of the eleven trials meeting selection criteria: 10 796 patients received SGLT2i and 10 796 received placebo. SGLT2i therapy was associated with a significant reduction in the risk of SCD (risk ratios [RR]: 0.68; 95% confidence intervals [CI]: 0.48-0.95; p = .03; I2 = 0%). Absent dedicated rhythm monitoring, there were no significant differences in the incidence of sustained ventricular arrhythmias not associated with SCD (RR: 1.03; 95% CI: 0.83-1.29; p = .77; I2 = 0%) or atrial arrhythmias (RR: 0.91; 95% CI: 0.77-1.09; p = .31; I2 = 29%) between patients receiving an SGLT2i versus placebo. CONCLUSION: SGLT2i therapy is associated with a reduced risk of SCD in patients with heart failure receiving contemporary medical therapy. Prospective trials are needed to determine the long-term impact of SGLT2i therapy on atrial and ventricular arrhythmias.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Fibrilação Atrial/complicações , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/complicações , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos
10.
JACC Clin Electrophysiol ; 9(4): 481-493, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36752473

RESUMO

BACKGROUND: During atrial fibrillation ablations using thermal energy, the treatment effect is attributed to not just pulmonary vein isolation (PVI), but also to modulation of the autonomic nervous system by ablation of cardiac ganglionated plexi (GP). OBJECTIVES: This study sought to assess the impact of pulsed field ablation (PFA) on the GP in patients undergoing PVI. METHODS: In the retrospective phase, heart rate was assessed pre- versus post-PVI using PFA, cryoballoon ablation, or radiofrequency ablation. In the prospective phase, a pentaspline PFA catheter was used in a protocol: 1) pre-PFA, high-frequency stimulation (HFS) identified GP sites by vagal effects; 2) PVI was performed assessing for repetitive vagal effects over each set of PF applications; 3) mapping defined PVI extent to identify those GP in the ablation zone; and 4) repeat HFS at GP sites to assess for persistence of vagal effects. RESULTS: Between baseline and 3 months, heart rates in the retrospective radiofrequency ablation (n = 40), cryoballoon (n = 40), and PFA (n = 40) cohorts increased by 8.9 ± 11.4, 11.1 ± 9.4, and -0.1 ± 9.2 beats/min, respectively (P= 0.01 PFA vs radiofrequency ablation; P= 0.01 PFA vs cryoballoon ablation). In the prospective phase, pre-PFA HFS in 20 additional patients identified 65 GP sites. During PFA, vagal effects were noted in 45% of first PF applications, persisting through all applications in 83%. HFS post-PFA reproduced vagal effects in 29 of 38 sites (76%) in low-voltage tissue. CONCLUSIONS: PFA has minimal effect on GP. Unlike with thermal ablation, the mechanism by which PFA treats atrial fibrillation is mediated solely by durable PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Nervo Vago/cirurgia
11.
Ann Behav Med ; 57(2): 155-164, 2023 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-34637503

RESUMO

BACKGROUND: Depression after acute coronary syndrome (ACS) is common and increases risks of adverse outcomes, but it remains unclear which depression features are most associated with major adverse cardiac events (MACE) and all-cause mortality (ACM). PURPOSE: To examine whether a subtype of depression characterized by anhedonia and major depressive disorder (MDD) predicts 1-year MACE/ACM occurrence in ACS patients compared to no MDD history. We also consider other depression features in the literature as predictors. METHODS: Patients (N = 1,087) presenting to a hospital with ACS completed a self-report measure of current depressive symptoms in-hospital and a diagnostic interview assessing MDD within 1 week post-hospitalization. MACE/ACM events were assessed at 1-, 6-, and 12-month follow-ups. Cox regression models were used to examine the association of the anhedonic depression subtype and MDD without anhedonia with time to MACE/ACM, adjusting for sociodemographic and clinical covariates. RESULTS: There were 142 MACE/ACM events over the 12-month follow-up. The 1-year MACE/ACM in patients with anhedonic depression, compared to those with no MDD, was somewhat higher in an age-adjusted model (hazard ratio [HR] = 1.63, p = .08), but was not significant after further covariate adjustment (HR = 1.24, p = .47). Of the additional depression features, moderate-to-severe self-reported depressive symptoms significantly predicted the risk of MACE/ACM, even in covariate-adjusted models (HR = 1.72, p = .04), but the continuous measure of self-reported depressive symptoms did not. CONCLUSION: The anhedonic depression subtype did not uniquely predict MACE/ACM as hypothesized. Moderate-to-severe levels of total self-reported depressive symptoms, however, may be associated with increased MACE/ACM risk, even after accounting for potential sociodemographic and clinical confounders.


Assuntos
Síndrome Coronariana Aguda , Transtorno Depressivo Maior , Humanos , Síndrome Coronariana Aguda/complicações , Depressão/complicações , Transtorno Depressivo Maior/complicações , Anedonia , Modelos de Riscos Proporcionais , Fatores de Risco
14.
Circ Arrhythm Electrophysiol ; 15(5): e010020, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35476455

RESUMO

BACKGROUND: Frequent premature ventricular contractions (PVCs) are often amenable to catheter ablation. However, a deep intramural focus may lead to failure due to inability of standard ablation techniques to penetrate the focus. We sought to assess the efficacy and safety of infusion needle ablation (INA) for PVCs that are refractory to standard radiofrequency ablation. METHODS: Under 2 Food and Drug Administration approved protocols, INA was evaluated in patients with frequent PVCs that were refractory to standard ablation. Initial targets for ablation were selected by standard mapping techniques. INA was performed with a deflectable catheter equipped with an extendable/retractable needle at the tip that can be extended up to 12 mm into the myocardium and is capable of pacing and recording. After contrast injection for location assessment, radiofrequency ablation was performed with the needle tip using a temperature-controlled mode (maximum temperature 60 °C) with saline infusion from the needle. The primary end point was a decrease in PVC burden to <5000/24 hours at 6 months. The primary safety end point was incidence of procedure- or device-related serious adverse events. RESULTS: At 4 centers, 35 patients (age 55.3±16.9 years, 74.2% male) underwent INA. The baseline median PVC burden was 25.4% (interquartile range, 18.4%-33.9%) and mean left ventricular ejection fraction was 37.7±12.3%. Delivering 10.3±8.0 INA lesions/patient (91% had adjunctive standard radiofrequency ablation also) resulted in acute PVC elimination in 71.4%. After a mean follow-up of 156±109 days, the primary efficacy end point was met in 73.3%. The median PVC burden decreased to 0.8% (interquartile range, 0.1%-6.0%; P<0.001). The primary safety end point occurred in 14.3% consisting of 1 (2.9%) heart block, 1 (2.9%) femoral artery dissection, and 3 (8.6%) pericardial effusions (all treated percutaneously). CONCLUSIONS: INA is effective for the elimination of frequent PVCs that are refractory to conventional ablation and is associated with an acceptable safety profile. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01791543 and NCT03204981.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
15.
J Cardiovasc Electrophysiol ; 33(2): 308-314, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34845805

RESUMO

BACKGROUND: Increasing interest in physiological pacing has been countered with challenges such as accurate lead deployment and increasing pacing thresholds with His-bundle pacing (HBP). More recently, left bundle branch area pacing (LBBAP) has emerged as an alternative approach to physiologic pacing. OBJECTIVE: To compare procedural outcomes and pacing parameters at follow-up during initial adoption of HBP and LBBAP at a single center. METHODS: Retrospective review, from September 2016 to January 2020, identified the first 50 patients each who underwent successful HBP or LBBAP. Pacing parameters were then assessed at first follow-up after implantation and after approximately 1 year, evaluating for acceptable pacing parameters defined as sensing R-wave amplitude >5 mV, threshold <2.5 V @ 0.5 ms, and impedance between 400 and 1200 Ω. RESULTS: The HBP group was younger with lower ejection fraction compared to LBBAP (73.2 ± 15.3 vs. 78.2 ± 9.2 years, p = .047; 51.0 ± 15.9% vs. 57.0 ± 13.1%, p = .044). Post-procedural QRS widths were similarly narrow (119.8 ± 21.2 vs. 116.7 ± 15.2 ms; p = .443) in both groups. Significantly fewer patients with HBP met the outcome for acceptable pacing parameters at initial follow-up (56.0% vs. 96.4%, p = .001) and most recent follow-up (60.7% vs. 94.9%, p ≤ .001; at 399 ± 259 vs. 228 ± 124 days, p ≤ .001). More HBP patients required lead revision due to early battery depletion or concern for pacing failure (0% vs. 13.3%, at a mean of 664 days). CONCLUSION: During initial adoption, HBP is associated with a significantly higher frequency of unacceptable pacing parameters, energy consumption, and lead revisions compared with LBBAP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
16.
Cureus ; 13(11): e19195, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34873534

RESUMO

Genetic channelopathies can predispose individuals to life-threatening arrhythmias. Two such channelopathies are long QT syndrome (LQTS) and catecholaminergic polymorphic ventricular tachycardia (CPVT). To the best of our knowledge, we present the first case of LQTS with novel combined genetic mutations of KCNH2 and cardiac ryanodine receptor (RYR2) genes.

17.
Am J Cardiol ; 159: 129-137, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34579830

RESUMO

During the clinical care of hospitalized patients with COVID-19, diminished QRS amplitude on the surface electrocardiogram (ECG) was observed to precede clinical decompensation, culminating in death. This prompted investigation into the prognostic utility and specificity of low QRS complex amplitude (LoQRS) in COVID-19. We retrospectively analyzed consecutive adults admitted to a telemetry service with SARS-CoV-2 (n = 140) or influenza (n = 281) infection with a final disposition-death or discharge. LoQRS was defined as a composite of QRS amplitude <5 mm or <10 mm in the limb or precordial leads, respectively, or a ≥50% decrease in QRS amplitude on follow-up ECG during hospitalization. LoQRS was more prevalent in patients with COVID-19 than influenza (24.3% vs 11.7%, p = 0.001), and in patients who died than survived with either COVID-19 (48.1% vs 10.2%, p <0.001) or influenza (38.9% vs 9.9%, p <0.001). LoQRS was independently associated with mortality in patients with COVID-19 when adjusted for baseline clinical variables (odds ratio [OR] 11.5, 95% confidence interval [CI] 3.9 to 33.8, p <0.001), presenting and peak troponin, D-dimer, C-reactive protein, albumin, intubation, and vasopressor requirement (OR 13.8, 95% CI 1.3 to 145.5, p = 0.029). The median time to death in COVID-19 from the first ECG with LoQRS was 52 hours (interquartile range 18 to 130). Dynamic QRS amplitude diminution is a strong independent predictor of death over not only the course of COVID-19 infection, but also influenza infection. In conclusion, this finding may serve as a pragmatic prognostication tool reflecting evolving clinical changes during hospitalization, over a potentially actionable time interval for clinical reassessment.


Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/virologia , COVID-19/complicações , Eletrocardiografia , Influenza Humana/complicações , Pneumonia Viral/complicações , Idoso , COVID-19/mortalidade , Feminino , Mortalidade Hospitalar , Hospitalização , Humanos , Influenza Humana/mortalidade , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque/epidemiologia , Pneumonia Viral/mortalidade , Pneumonia Viral/virologia , Prognóstico , Estudos Retrospectivos , SARS-CoV-2
18.
Europace ; 23(11): 1757-1766, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34151947

RESUMO

AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia , Humanos , Terapia a Laser , Veias Pulmonares/cirurgia , Ablação por Radiofrequência , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
19.
JAMA Cardiol ; 6(6): 697-705, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33909022

RESUMO

Importance: Early rhythm control of atrial fibrillation (AF) with either antiarrhythmic drugs (AADs) or catheter ablation has been reported to improve cardiovascular outcomes compared with usual care; however, the optimal therapeutic modality to achieve early rhythm control is unclear. Objective: To assess the safety and efficacy of AF ablation as first-line therapy when compared with AADs in patients with paroxysmal AF. Data Sources: PubMed/MEDLINE, Scopus, Google Scholar, and various major scientific conference sessions from January 1, 2000, through November 23, 2020. Study Selection: Randomized clinical trials (RCTs) published in English that had at least 12 months of follow-up and compared clinical outcomes of ablation vs AADs as first-line therapy in adults with AF. The quality of individual studies was assessed using the Cochrane risk of bias tool. Six RCTs met inclusion criteria, including 1212 patients. Data Extraction and Synthesis: Two investigators independently extracted data. Reporting was performed in compliance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analysis) guidelines. Analysis was performed using a random-effects model with the Mantel-Haenszel method, and results are presented as 95% CIs. Main Outcomes and Measures: Main outcomes were safety and efficacy of AF ablation as first-line therapy when compared with AADs. Trials were evaluated as having low risk of selection and attrition biases, high risk of performance bias, and with unclear risk for detection biases due to unblinding and open-label designs. Results: A total of 6 RCTs involving 1212 patients with AF were included (609 were randomized to AF ablation and 603 to drug therapy; mean [SD] age, 56 [11] years). Compared with AADs, catheter ablation use was associated with reductions in recurrent atrial arrhythmia (32.3% vs 53%; risk ratio [RR], 0.62; 95% CI, 0.51-0.74; P < .001; I2 = 40%), with a number needed to treat with ablation to prevent 1 arrhythmia of 5. Use of ablation was also associated with reduced symptomatic atrial arrhythmia (11.8% vs 26.4%; RR, 0.44; 95% CI, 0.27-0.72; P = .001; I2 = 54%) and hospitalization (5.6% vs 18.7%; RR, 0.32; 95% CI, 0.19-0.53; P < .001) with no significant difference in serious adverse events between the groups (4.2% vs 2.8%; RR, 1.52; 95% CI, 0.81-2.85; P = .19). Conclusions and Relevance: In this meta-analysis of randomized clinical trials including first-line therapy of patients with paroxysmal AF, catheter ablation compared with antiarrhythmic drugs was associated with reductions in recurrence of atrial arrhythmias and hospitalizations, with no difference in major adverse events.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter , Hospitalização , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
JACC Clin Electrophysiol ; 7(9): 1120-1130, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33895107

RESUMO

OBJECTIVES: The goal of this study is to determine the incidence, predictors, and outcomes of atrial fibrillation (AF) or atrial flutter (AFL) in patients hospitalized with coronavirus disease-2019 (COVID-19). BACKGROUND: COVID-19 results in increased inflammatory markers previously associated with atrial arrhythmias. However, little is known about their incidence or specificity in COVID-19 or their association with outcomes. METHODS: This is a retrospective analysis of 3,970 patients admitted with polymerase chain reaction-positive COVID-19 between February 4 and April 22, 2020, with manual review performed of 1,110. The comparator arm included 1,420 patients with influenza hospitalized between January 1, 2017, and January 1, 2020. RESULTS: Among 3,970 inpatients with COVID-19, the incidence of AF/AFL was 10% (n = 375) and in patients without a history of atrial arrhythmias it was 4% (n = 146). Patients with new-onset AF/AFL were older with increased inflammatory markers including interleukin 6 (93 vs. 68 pg/ml; p < 0.01), and more myocardial injury (troponin-I: 0.2 vs. 0.06 ng/ml; p < 0.01). AF and AFL were associated with increased mortality (46% vs. 26%; p < 0.01). Manual review captured a somewhat higher incidence of AF/AFL (13%, n = 140). Compared to inpatients with COVID-19, patients with influenza (n = 1,420) had similar rates of AF/AFL (12%, n = 163) but lower mortality. The presence of AF/AFL correlated with similarly increased mortality in both COVID-19 (relative risk: 1.77) and influenza (relative risk: 1.78). CONCLUSIONS: AF/AFL occurs in a subset of patients hospitalized with either COVID-19 or influenza and is associated with inflammation and disease severity in both infections. The incidence and associated increase in mortality in both cohorts suggests that AF/AFL is not specific to COVID-19, but is rather a generalized response to the systemic inflammation of severe viral illnesses.


Assuntos
Fibrilação Atrial , COVID-19 , Influenza Humana , Fibrilação Atrial/epidemiologia , Humanos , Incidência , Influenza Humana/epidemiologia , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...