Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orbit ; 42(4): 441-444, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35075984

RESUMO

A 61-year-old man with no significant past medical history presented to a quaternary ophthalmic referral center with acute right-sided medial canthal pain, periorbital edema, and erythema despite oral antibiotic therapy. CT imaging confirmed the presence of right preseptal cellulitis and lacrimal sac aspiration identified Enterobacter cloacae. A diagnosis of acute right-sided dacryocystitis with preseptal cellulitis was made. He was successfully treated with broadening of antibiotic therapy to intravenous meropenem. Symptomatic resolution was noted on follow-up without evidence of disease recurrence. This unusual case of Enterobacter cloacae dacryocystitis and preseptal cellulitis highlights the increasing prevalence and challenges of treating these uncommon organisms.


Assuntos
Dacriocistite , Doenças Palpebrais , Aparelho Lacrimal , Masculino , Humanos , Pessoa de Meia-Idade , Celulite (Flegmão)/diagnóstico , Celulite (Flegmão)/tratamento farmacológico , Enterobacter cloacae , Dacriocistite/diagnóstico por imagem , Dacriocistite/tratamento farmacológico , Antibacterianos/uso terapêutico , Doenças Palpebrais/diagnóstico
2.
Indian J Crit Care Med ; 25(9): 981-986, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34963714

RESUMO

N95 respirators and safety goggles are important components of personal protective equipment to reduce the spread of airborne infections, such as COVID-19, among healthcare workers. Poor N95 respirator seal may reduce its protective effect, thereby increasing transmission. Quantitative fit testing is an established way of assessing the N95 respirator fit, which provides a quantitative measure for seal, called the fit factor. Duckbill N95 respirators frequently fail the fit test. We hypothesized that using safety goggles with a wraparound elastic headband will increase their fit-factor by reinforcing the seal between the face and the upper margin of the respirator. We studied the effect of safety goggles with a wraparound elastic headband (3M™ Chemical Splash Resistant Goggles, ID 70006982741) on the fit factor of two types of Duckbill N95 respirators (Halyard FLUIDSHIELD*3, Model 99SA070M, and ProShield® N95 Model TN01-11) in 63 healthy volunteers in a nonrandomized, before-and-after intervention study design. The mean fit factor increased from 69.4 to 169.1 increased from 17/63 (27%) to 46/63 (73%) after the intervention (p <0.0001, OR 3 [95% CI = 4.9-1223]). This is the first study to explore the impact of safety goggles on N95 respirator fit. We conclude that the use of safety goggles with a wraparound elastic headband increases the fit factor of the tested Duckbill N95 respirators. HOW TO CITE THIS ARTICLE: Johns M, Kyaw S, Lim R, Stewart WC, Thambiraj SR, Shehabi Y, et al. Fit Factor Change on Quantitative Fit Testing of Duckbill N95 Respirators with the Use of Safety Goggles. Indian J Crit Care Med 2021;25(9):981-986.

3.
Intern Med J ; 48(12): 1514-1520, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30517986

RESUMO

There is a global outbreak of infections due to Mycobacterium chimaera associated with cardiac surgery. The most serious infections involve prosthetic material implantation, and all have followed surgical procedures involving cardiopulmonary bypass. We describe a cluster of four cases following cardiac surgery at a tertiary referral centre in Sydney, Australia. We report novel clinical findings, including haemolysis and kidney rupture possibly related to immune reconstitution inflammatory syndrome. The positive effect of corticosteroids on haemodynamic function in two cases and the failure of currently recommended antimicrobial therapy to sterilise prosthetic valve material in the absence of surgery despite months of treatment are also critically examined. Positron emission tomography was positive in two cases despite normal transoesophageal echocardiograms. The proportion of cases with M. chimaera infection after aortic valve replacement (4/890, 0.45%; 95% confidence interval 0.18-1.15%) was significantly higher than after all other cardiothoracic surgical procedures (0/2433, 0%; 95% confidence interval 0-0.16%).


Assuntos
Antibacterianos , Valva Aórtica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Infecções por Mycobacterium não Tuberculosas , Mycobacterium , Complicações Pós-Operatórias , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/administração & dosagem , Antibacterianos/classificação , Valva Aórtica/microbiologia , Valva Aórtica/cirurgia , Austrália/epidemiologia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium/efeitos dos fármacos , Mycobacterium/isolamento & purificação , Infecções por Mycobacterium não Tuberculosas/diagnóstico , Infecções por Mycobacterium não Tuberculosas/etiologia , Tomografia por Emissão de Pósitrons/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/microbiologia , Medição de Risco , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...