Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol Exp ; 8(1): 28, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38448783

RESUMO

BACKGROUND: To evaluate the clinical usefulness of thin-slice echo-planar imaging (EPI)-based diffusion-weighted imaging (DWI) with an on-console distortion correction technique, termed reverse encoding distortion correction DWI (RDC-DWI), in patients with non-functioning pituitary neuroendocrine tumor (PitNET)/pituitary adenoma. METHODS: Patients with non-functioning PitNET/pituitary adenoma who underwent 3-T RDC-DWI between December 2021 and September 2022 were retrospectively enrolled. Image quality was compared among RDC-DWI, DWI with correction for distortion induced by B0 inhomogeneity alone (B0-corrected-DWI), and original EPI-based DWI with anterior-posterior phase-encoding direction (AP-DWI). Susceptibility artifact, anatomical visualization of cranial nerves, overall tumor visualization, and visualization of cavernous sinus invasion were assessed qualitatively. Quantitative assessment of geometric distortion was performed by evaluation of anterior and posterior displacement between each DWI and the corresponding three-dimensional T2-weighted imaging. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient values were measured. RESULTS: Sixty-four patients (age 70.8 ± 9.9 years [mean ± standard deviation]; 33 females) with non-functioning PitNET/pituitary adenoma were evaluated. In terms of susceptibility artifacts in the frontal and temporal lobes, visualization of left trigeminal nerve, overall tumor visualization, and anterior displacement, RDC-DWI performed the best and B0-corrected-DWI performed better than AP-DWI. The right oculomotor and right trigeminal nerves were better visualized by RDC-DWI than by B0-corrected-DWI and AP-DWI. Visualization of cavernous sinus invasion and posterior displacement were better by RDC-DWI and B0-corrected-DWI than by AP-DWI. SNR and CNR were the highest for RDC-DWI. CONCLUSIONS: RDC-DWI achieved excellent image quality regarding susceptibility artifact, geometric distortion, and tumor visualization in patients with non-functioning PitNET/pituitary adenoma. RELEVANCE STATEMENT: RDC-DWI facilitates excellent visualization of the pituitary region and surrounding normal structures, and its on-console distortion correction technique is convenient. RDC-DWI can clearly depict cavernous sinus invasion of PitNET/pituitary adenoma even without contrast medium. KEY POINTS: • RDC-DWI is an EPI-based DWI technique with a novel on-console distortion correction technique. • RDC-DWI corrects distortion due to B0 field inhomogeneity and eddy current. • We evaluated the usefulness of thin-slice RDC-DWI in non-functioning PitNET/pituitary adenoma. • RDC-DWI exhibited excellent visualization in the pituitary region and surrounding structures. • In addition, the on-console distortion correction of RDC-DWI is clinically convenient.


Assuntos
Tumores Neuroendócrinos , Neoplasias Hipofisárias , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Neoplasias Hipofisárias/diagnóstico por imagem , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética , Artefatos
2.
Eur Radiol ; 33(6): 4488-4499, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36418626

RESUMO

OBJECTIVES: To evaluate susceptibility values associated with iron accumulation in the deep gray matter during postnatal development and to compare magnetic susceptibility between patients with normal and delayed development. METHODS: Patients with postmenstrual age (PMA) ≤ 1000 days underwent MR scans between August 2015 and April 2020 at our hospital. Quantitative susceptibility mapping (QSM) was performed, and magnetic susceptibility was measured using three-dimensional volumes of interest (VOIs) for the caudate nucleus (CN), globus pallidus (GP), putamen (PT), and ventrolateral thalamic nucleus (VL). Cross-sectional analysis was performed for 99 patients with normal development and 39 patients with delayed development. Longitudinal analysis was also performed to interpret changes over time in 13 patients with normal development. Correlations between magnetic susceptibility in VOIs and PMA or chronological age (CA) were assessed. RESULTS: Susceptibility values for CN, GP, PT, and VL showed positive moderate correlations with both PMA (ρ = 0.45, 0.69, 0.62, and 0.33, respectively) and CA (ρ = 0.53, 0.69, 0.66, and 0.39, respectively). The slope of the correlation between susceptibility values and age was highest in the GP among the four gray matter areas. Susceptibility values for the CN, GP, PT, and VL were higher with normal development than with delayed development at early postnatal age, although a significant difference was only observed for the CN. Susceptibility values also increased with age in the longitudinal analysis. CONCLUSIONS: Magnetic susceptibility values in deep gray matter increased with age ≤ 1000 days. The normal development group showed higher susceptibility values than the delayed development group at early postnatal age (PMA ≤ 285 days). KEY POINTS: • Magnetic susceptibilities in deep gray matter nuclei increased with age (postmenstrual age ≤ 1000 days) in a large number of pediatric patients. • The normal development group showed higher susceptibility values than the delayed development group in the basal ganglia and ventrolateral thalamic nucleus at early postnatal age (PMA ≤ 285 days).


Assuntos
Substância Cinzenta , Imageamento por Ressonância Magnética , Humanos , Criança , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Transversais , Ferro , Núcleo Caudado , Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem
3.
Eur Radiol ; 33(4): 2895-2904, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36422648

RESUMO

OBJECTIVES: To assess the accuracy, repeatability, and reproducibility of T1 and T2 relaxation time measurements by three-dimensional magnetic resonance fingerprinting (3D MRF) using various dictionary resolutions. METHODS: The ISMRM/NIST phantom was scanned daily for 10 days in two 3 T MR scanners using a 3D MRF sequence reconstructed using four dictionaries with varying step sizes and one dictionary with wider ranges. Thirty-nine healthy volunteers were enrolled: 20 subjects underwent whole-brain MRF scans in both scanners and the rest in one scanner. ROI/VOI analyses were performed on phantom and brain MRF maps. Accuracy, repeatability, and reproducibility metrics were calculated. RESULTS: In the phantom study, all dictionaries showed high T1 linearity to the reference values (R2 > 0.99), repeatability (CV < 3%), and reproducibility (CV < 3%) with lower linearity (R2 > 0.98), repeatability (CV < 6%), and reproducibility (CV ≤ 4%) for T2 measurement. The volunteer study demonstrated high T1 reproducibility of within-subject CV (wCV) < 4% by all dictionaries with the same ranges, both in the brain parenchyma and CSF. Yet, reproducibility was moderate for T2 measurement (wCV < 8%). In CSF measurement, dictionaries with a smaller range showed a seemingly better reproducibility (T1, wCV 3%; T2, wCV 8%) than the much wider range dictionary (T1, wCV 5%; T2, wCV 13%). Truncated CSF relaxometry values were evident in smaller range dictionaries. CONCLUSIONS: The accuracy, repeatability, and reproducibility of 3D MRF across various dictionary resolutions were high for T1 and moderate for T2 measurements. A lower-resolution dictionary with a well-defined range may be adequate, thus significantly reducing the computational load. KEY POINTS: • A lower-resolution dictionary with a well-defined range may be sufficient for 3D MRF reconstruction. • CSF relaxation times might be underestimated due to truncation by the upper dictionary range. • Dictionary with a higher upper range might be advisable, especially for CSF evaluation and elderly subjects whose perivascular spaces are more prominent.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Idoso , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
4.
Eur Radiol ; 33(2): 936-946, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36006430

RESUMO

OBJECTIVES: To develop a generative adversarial network (GAN) model to improve image resolution of brain time-of-flight MR angiography (TOF-MRA) and to evaluate the image quality and diagnostic utility of the reconstructed images. METHODS: We included 180 patients who underwent 1-min low-resolution (LR) and 4-min high-resolution (routine) brain TOF-MRA scans. We used 50 patients' datasets for training, 12 for quantitative image quality evaluation, and the rest for diagnostic validation. We modified a pix2pix GAN to suit TOF-MRA datasets and fine-tuned GAN-related parameters, including loss functions. Maximum intensity projection images were generated and compared using multi-scale structural similarity (MS-SSIM) and information theoretic-based statistic similarity measure (ISSM) index. Two radiologists scored vessels' visibilities using a 5-point Likert scale. Finally, we evaluated sensitivities and specificities of GAN-MRA in depicting aneurysms, stenoses, and occlusions. RESULTS: The optimal model was achieved with a lambda of 1e5 and L1 + MS-SSIM loss. Image quality metrics for GAN-MRA were higher than those for LR-MRA (MS-SSIM, 0.87 vs. 0.73; ISSM, 0.60 vs. 0.35; p.adjusted < 0.001). Vessels' visibility of GAN-MRA was superior to LR-MRA (rater A, 4.18 vs. 2.53; rater B, 4.61 vs. 2.65; p.adjusted < 0.001). In depicting vascular abnormalities, GAN-MRA showed comparable sensitivities and specificities, with greater sensitivity for aneurysm detection by one rater (93% vs. 84%, p < 0.05). CONCLUSIONS: An optimized GAN could significantly improve the image quality and vessel visibility of low-resolution brain TOF-MRA with equivalent sensitivity and specificity in detecting aneurysms, stenoses, and occlusions. KEY POINTS: • GAN could significantly improve the image quality and vessel visualization of low-resolution brain MR angiography (MRA). • With optimally adjusted training parameters, the GAN model did not degrade diagnostic performance by generating substantial false positives or false negatives. • GAN could be a promising approach for obtaining higher resolution TOF-MRA from images scanned in a fraction of time.


Assuntos
Encéfalo , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Constrição Patológica , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Imageamento por Ressonância Magnética , Angiografia Cerebral/métodos
5.
Curr Res Transl Med ; 72(2): 103437, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38244275

RESUMO

BACKGROUND: Type 2 diabetes (T2D) is a progressive disease. Many drugs currently being used for the management of T2D have minimal effect on pancreatic beta cells regeneration. Cell-based therapies might provide potential benefits in this aspect. METHODS: A pilot study in five T2D patients with 12 months follow-up was performed to evaluate the effect of autologous bone marrow mononuclear stem cells (BM-MNCs) infusion into pancreatic arteries on the insulin requirement, beta-cell function, insulin resistance, and systemic inflammatory marker (CRP). RESULTS: The primary endpoint, a 50 % reduction of total insulin doses from baseline, was not achieved in this study. However, a trend of increasing fasting C-peptide (p = 0.07) and C-peptide 60' (p = 0.07) and 90' (p = 0.07) after a mixed-meal tolerance test was observed 12 months post-infusion compared to baseline levels. A similar result was observed for the homeostatic model assessment of beta cell function (HOMA1-B), an index for beta cell function. No improvement was observed for insulin resistance measured by homeostasis model assessment of insulin resistance (HOMA1-IR) and systemic inflammatory parameter. CONCLUSION: Intraarterial pancreatic autologous BM-MNCs infusion might potentially improve beta cell function in T2D patients, although further study is needed to confirm this finding.

6.
Case Rep Gastroenterol ; 16(1): 179-185, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35528777

RESUMO

Bleeding esophageal varices (EV) have the highest mortality rate from all complications of liver cirrhosis (LC). Several Doppler ultrasound (DUS) studies have been done on the splenic or portal vein (PV) to evaluate the hemodynamic of the esophageal vein. Our study focused on finding a better index using the ratio from two parameters correlated with EV, splenic vein flow volume (SFV), and PV flow velocity. In this study, 28 patients with LC were evaluated using DUS to compare the SFV to PV flow velocity/speed (Sv/Ps) index and other measured DUS parameters with the EV degree. Afterward, the receiver operating characteristic (ROC) curve analysis was performed on statistically significant DUS parameters. Mean Sv/Ps index value in the group of nonvarices was 9.89 ± 3.56; 19.50 ± 5.56 in the small esophageal varices (SEV) and 74.12 ± 29.37 in the large esophageal varices (LEV) group with p < 0.001. ROC curve analysis generated an optimal cutoff point of 16.5 (90% sensitivity and 100% specificity) to predict the presence of EV and the cutoff point of 46.7 (100% sensitivity and specificity) to predict the presence of LEV. In conclusion, the Sv/Ps index measured using DUS can be used as a noninvasive method to predict the presence of EV, especially in predicting LEV.

7.
Magn Reson Med Sci ; 21(4): 633-647, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34602534

RESUMO

PURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures.


Assuntos
Artefatos , Aumento da Imagem , Algoritmos , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
8.
J Magn Reson Imaging ; 53(4): 1151-1161, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33067897

RESUMO

BACKGROUND: Hypothalamic-pituitary-thyroid (HPT) maturation has not been extensively evaluated using neonatal MRI, even though both structures are visualized on MRI. HYPOTHESIS: That signal intensity and volume of pituitary and thyroid (T) glands on MRI in neonates may be interrelated. STUDY TYPE: Retrospective. SUBJECTS: In all, 102 participants. FIELD STRENGTH/SEQUENCE: 3.0T, T1 -weighted pointwise encoding time reduction with radial acquisition (PETRA). ASSESSMENT: The volume of interest of the anterior pituitary (AP), posterior pituitary (PP), and T on MRI were defined on T1 -PETRA by two radiologists, and volumes of AP (AP_vol) and thyroid (T_vol) were calculated. Gestational age (GA), chronological age (CA), GA+CA, birth weight (BW), and thyroid function were recorded. Mean and maximum signal intensities of AP, PP, and T were normalized using signals from the pons and spinal cord as follows: signal ratio of anterior pituitary/pons (AP/pons), signal ratio of posterior pituitary/pons (PP/pons), and signal ratio of thyroid/cord (T/cord) T/cord, respectively. STATISTICAL TESTS: Correlations between signal intensity and volume measures and GA, CA, GA+CA, and BW were assessed using Pearson's correlation coefficient or Spearman's rank correlation coefficient. Thyroid function analysis and Tmean /cord, Tmax /cord, and T_vol were evaluated using the Steel-Dwass test. RESULTS: APmean /pons correlated positively with GA (ρ = 0.62, P < 0.001) and BW (ρ = 0.74, P < 0.001), and negatively with CA (ρ = -0.86, P < 0.001) and GA+CA (ρ = -0.46, P < 0.001). PPmean /pons correlated positively with GA (ρ = 0.49, P < 0.001) and BW (ρ = 0.63, P < 0.001), and negatively with CA (ρ = -0.70, P < 0.001) and GA+CA (r = -0.38, P < 0.001). Tmean /cord correlated positively with GA (ρ = 0.48, P < 0.001) and BW (ρ = 0.55, P < 0.001), and negatively with CA (ρ = -0.59, P < 0.001) and GA+CA (ρ = -0.22, P = 0.03). AP_vol correlated positively with GA (ρ = 0.68, P < 0.001) and BW (ρ = 0.73, P < 0.001), and negatively with CA (ρ = -0.72, P < 0.001). T_vol correlated positively with GA (ρ = 0.50, P < 0.001) and BW (ρ = 0.61, P < 0.001), and negatively with CA (ρ = -0.54, P < 0.001). APmean /pons correlated positively with Tmean /cord (ρ = 0.61, P < 0.001). DATA CONCLUSION: Signal and volume of pituitary and thyroid glands correlated positively with GA and BW, and negatively with CA in neonates. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 5.


Assuntos
Imageamento por Ressonância Magnética , Glândula Tireoide , Peso ao Nascer , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Glândula Tireoide/diagnóstico por imagem
9.
Invest Radiol ; 56(2): 69-77, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649332

RESUMO

OBJECTIVES: The aim of this study was to assess the accuracy, reliability, and cerebral microbleed (CMB) detection performance of 2-minute quantitative susceptibility mapping (QSM) from 3-dimensional echo-planar imaging (3D-EPI). MATERIALS AND METHODS: Gadolinium phantom study was conducted using 3D-EPI, single-echo time (TE), and multi-TE gradient-recalled echo (GRE) sequences on two 3-T magnetic resonance (MR) scanners to assess the accuracy between measured and theoretical susceptibility values. The institutional review board approved this prospective study, and 40 healthy volunteers were enrolled with written consent between April 2018 and October 2019. Each underwent 3D-EPI, single-TE, and multi-TE GRE sequences consecutively on one 3-T MR scanner, and QSMs were calculated to assess the reliability of 3D-EPI QSM. Intraclass correlation coefficient (ICC), linear regression, and Bland-Altman plots were calculated. Patients with CMB who underwent both 3D-EPI and GRE QSM scans were retrospectively enrolled. Two radiologists evaluated images independently, and Cohen κ coefficients were calculated to compare CMB detection performance. RESULTS: Phantom study showed excellent validity of 3D-EPI QSM on both MR scanners: Skyra, R2 = 0.996, P < 0.001, ICC = 0.997, mean difference, -2 ppb (95% confidence interval [CI], -45 to 40 ppb); Prisma, R2 = 0.992, P < 0.001, ICC = 0.988, mean difference, 15 ppb (95% CI, -67 to 97 ppb). A human study of 40 healthy volunteers (59 ± 13 years, 25 women) showed excellent reliability with 3D-EPI QSM for both single-TE and multi-TE GRE (R2 = 0.981, P < 0.001, ICC = 0.988; R2 = 0.983, P < 0.001, ICC = 0.990, respectively), supported by a Bland-Altman mean difference of 4 ppb (95% CI, -15 to 23 ppb) for single-TE GRE and 3 ppb (95% CI, -15 to 20 ppb) for multi-TE GRE. The CMB detection performance evaluation from 38 patients (51 ± 20 years, 20 women) showed almost perfect agreement between 3D-EPI and GRE QSM for both raters (κ = 0.923 and 0.942, P < 0.001). CONCLUSIONS: Faster QSM from 3D-EPI demonstrated excellent accuracy, reliability, and CMB detection performance.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Hemorragia Cerebral/diagnóstico por imagem , Feminino , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Eur J Radiol Open ; 7: 100306, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33335952

RESUMO

INTRODUCTION: : Magnetic Resonance (MR) imaging using gadolinium contrast media is an essential imaging modality in diagnosing spondylitis. However, gadolinium contrast is not widely available in Indonesia and relatively expensive. Many MR studies in Indonesia are performed without contrast administration. It is unclear how confident non-contrast MR can diagnose tuberculous spondylitis in comparison to standard contrast MR. PURPOSES: : This study aims to evaluate the concordance between the contrast MR and non-contrast spine MR in diagnosing tuberculous spondylitis. We also evaluate the interobserver agreement between the general radiologist and musculoskeletal radiologist in interpreting non-contrast MR of spondylitis. MATERIALS AND METHODS: : A cross-sectional study using secondary data was performed to evaluate the concordance between the MR results regarding the usage of contrast media in diagnosing spondylitis. The inclusion criteria were patients over 17 years old who underwent complete sequences of contrast-enhanced MR examination of the spine, referred to radiology with the clinical diagnosis of suspected tuberculous spondylitis, spondylodiscitis, or both. All of the non-contrast and contrast-enhanced MR results were read and interpreted by two independent observers, a musculoskeletal radiologist and a general radiologist, blindly. The interobserver agreement analysis of the MR examination was conducted using Kappa and McNemar test. RESULTS: : There was no significant difference between the contrast and non-contrast MR in diagnosing spondylitis (P= 0.368) and no significant difference in the interpretation of MR between the first and the second observer (P =  0.343). The concordance between the contrast and non-contrast spine MR in diagnosing spondylitis (R: 0.88, P < 0.001) and the interpretation of MR between both observers (R: 0.65, P < 0.001) were showed in this study. CONCLUSION: : There is a high concordance between the contrast and non-contrast MR in diagnosing tuberculous spondylitis. Although contrast MR is preferred as the standard imaging method of spondylitis, in case gadolinium contrast is unavailable, non-contrast MR can still provide valuable information in diagnosing spondylitis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...