Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Rehabilitation (Stuttg) ; 62(5): 308-318, 2023 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-37848041

RESUMO

Changes in the employment market and improvements in the current prosthetic treatment have encouraged German Statutory Health Insurance e. V. (DGUV) to re-examine the standard values for reduced earning capacity after work related accidents. The new standard values for reduced earning capacity came into force on 01.11.2019. The present article summarises the consensus paper of the group of independent experts.


Assuntos
Seguro de Acidentes , Programas Nacionais de Saúde , Humanos , Alemanha , Renda , Emprego
2.
Z Evid Fortbild Qual Gesundhwes ; 130: 13-20, 2018 02.
Artigo em Alemão | MEDLINE | ID: mdl-28865987

RESUMO

In the mid-1920s Porter and others developed a reform approach for existing health care systems, aiming at a patient-focused, value-based orientation. Improving patient outcomes by attaining, preserving and restoring good health is inherently less costly than dealing with poor health. The authors of the present article will outline that the German statutory accident insurance system, which was already introduced in1884 and is of an evolving nature, reflects key elements of Porter's efficient value-based health care system. The German accident insurance system with its statutory mandate limited to the prevention and rehabilitation of work-related damage to one's health can also serve as a model for other larger health care insurance systems. Prevention and rehabilitation is pursued using all appropriate means to achieve the set goals of protecting and restoring individual health. In line with these objectives, the statutory health insurance controls the process in terms of the required care quality. The components of a complex health care system, usually managed by a variety of different institutions, are consolidated. Thus it can be ensured that in both prevention and rehabilitation all services that are necessary to keep focussing the value "individual health" rather than indemnities are applied.


Assuntos
Acidentes de Trabalho/prevenção & controle , Atenção à Saúde , Programas Governamentais , Seguro de Acidentes , Ferimentos e Lesões/reabilitação , Alemanha , Humanos , Seguro de Acidentes/legislação & jurisprudência , Programas Nacionais de Saúde/organização & administração
4.
Injury ; 46 Suppl 5: S18-24, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26343298

RESUMO

The objective of this study was to report on the safety, efficacy and clinical outcomes of the Polyax Locked Plating System (Biomet, Warsaw, IN, USA) in the management of acute (non-implant related and periprosthetic) distal femoral fractures. We retrospectively reviewed 71 patients with 73 distal femoral fractures. Thirty-three of the included fractures occurred around previously placed implants. The average patients' age was 67 years (range 18-98). There were 7 early postoperative complications (9.5%) including one deep surgical site infection, 2 pulmonary embolisms and 4 urinary or respiratory infections. At final follow-up (mean 12, range 9-55 months) all fractures progressed to clinical and radiological union. However, major revision surgery for healing problems was required in 5 cases (6.8%) and minor in 3 cases (4.1%). The average time to healing was 6 (range 3-23) months. Angulation less than 5 degrees in any plane was observed in 66 cases (89.7%), within 5-10 degrees in 5 cases (7.3%) and within 10-15 degrees in 2 cases (2.9%). The mean pre-injury and final follow-up values of Glasgow Outcome Scale were 1.5(1-3) and 1.7(1-3) respectively. Overall 61 patients (83.53%) retained their pre-injury activity status. The Polyax Locked Plating System offers a safe and efficient fixation in distal femoral fractures.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fraturas Periprotéticas/cirurgia , Infecção da Ferida Cirúrgica/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/fisiopatologia , Seguimentos , Consolidação da Fratura , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
6.
BMJ ; 340: c2332, 2010 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-20543010

RESUMO

OBJECTIVE: To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. DESIGN: Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. DATA SOURCES: Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. STUDY SELECTION: Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. DATA EXTRACTION: Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. DATA SYNTHESIS: 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). CONCLUSION: Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.


Assuntos
Artroplastia de Quadril/métodos , Fraturas do Colo Femoral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/mortalidade , Estudos de Coortes , Feminino , Fraturas do Colo Femoral/mortalidade , Humanos , Masculino , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação/estatística & dados numéricos , Fatores de Risco , Resultado do Tratamento
7.
Injury ; 40 Suppl 4: S36-46, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19895951

RESUMO

Single-pass, whole-body computed tomography (pan-CT) was proposed in the late 1990s as a new concept for the diagnostic work-up of severely injured patients. Since its introduction, it has led to considerable debate among clinicians and scientists, triggered by concerns about its immediate safety, questionable therapeutic advantages and exposure to radiation. However, it was recently shown that pan-CT scanning may be associated with a reduction in trauma mortality. In this article, we provide an overview of current knowledge of the value of this compelling concept. The diagnostic accuracy of multidetector row CT (MDCT) for clearing various anatomical regions in trauma patients is, at best, unclear. Little is known about the accuracy of pan-CT as a whole, which weakens statements about its effectiveness and prevents inferences about survival advantages. This last point may be explained by a stage-migration or "Will Rogers" phenomenon: Pan-CT increases injury severity by detecting lesions that would not have been recognized by conventional methods but still do not affect treatment decisions, thus artificially lowering the ratio of observed to expected deaths. In order to maintain the credibility of pan-CT technology for trauma, a rigorous, large-scale evaluation of its accuracy is required. Such an evaluation requires consensus about the definition of true and false positive and negative findings in the setting of blunt multiple trauma. In addition, triage criteria need to be refined to increase specificity and reduce the number of unnecessary scans.


Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Traumatismo Múltiplo/diagnóstico por imagem , Traumatismo Múltiplo/mortalidade , Tomografia Computadorizada por Raios X/métodos , Viés , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/mortalidade
8.
Am J Sports Med ; 37(9): 1692-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19483077

RESUMO

BACKGROUND: Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. PURPOSE: To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. METHODS: To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. RESULTS: After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. CONCLUSION: Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.


Assuntos
Implantes Absorvíveis , Ligamento Cruzado Anterior/cirurgia , Pinos Ortopédicos , Enxerto Osso-Tendão Patelar-Osso/instrumentação , Procedimentos Ortopédicos/métodos , Traumatismos dos Tendões/cirurgia , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
9.
Knee Surg Sports Traumatol Arthrosc ; 17(5): 446-55, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19132348

RESUMO

During a short period of time, surgical robots had been propagated for automated tunnel placement in anterior cruciate ligament (ACL) reconstruction. Clinical outcome data are currently unavailable. Between 2000 and 2003, 152 patients underwent ACL replacement with the assistance of the Computer Assisted Surgical Planning and Robotics system (CASPAR, OrtoMaquet, Germany) at our hospital. After minimal invasive pin placement in both the tibia and femur, computed tomography was used to register anatomical landmarks and to plan graft tunnel alignment. The robot was used to drill tibial and femoral tunnels in an outside-in fashion according to pre-operative planning. There was one procedure-specific Serious Adverse Event (i.e., an intraoperative transection of the posterior cruciate ligament). After IRB approval, all patients were invited for a follow-up examination. Data from 100 patients (35 women, 65 men, mean age 35 [SD 11] years, median follow-up 61 [range 42-77] months) form the basis of this report. Side-to-side differences in anterior laxity were measured with the KT-1000 arthrometer. Patient-centered outcomes included the Lysholm-Score, the lower extremity functional scale (LEFS), and the Short Form 36 (SF36). The mean KT-1000 side-to-side difference was 0.89 [95% confidence interval (CI) 0.52-1.26] mm. Eight and five patients had a positive Lachman and pivot shift test, respectively. The Lysholm-Score averaged 86 (95% CI 83-89) points. Excellent, good, fair, and poor outcomes were reported by 38, 32, 20, and 10 patients. The LEFS averaged 85 (95% CI 82-88) points. The mean SF36 Physical Component Score was 48.4 (95% CI 46.5-50.3), indicating residual deficits compared to the population norm. All tibial graft tunnels did not cross the Blumensaat line, but were placed slightly anterior to the optimal center of 42% reported in previous studies. Compared to literature data, robot-assisted ACL reconstruction with BTB grafts may lead to higher knee stability, but poorer functional outcomes. The immense additional efforts with the procedure did not pay off in a benefit to patients.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Enxerto Osso-Tendão Patelar-Osso/métodos , Ligamento Patelar/transplante , Procedimentos de Cirurgia Plástica/métodos , Robótica/métodos , Adulto , Artroscopia/efeitos adversos , Artroscopia/métodos , Enxerto Osso-Tendão Patelar-Osso/efeitos adversos , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Masculino , Satisfação do Paciente , Complicações Pós-Operatórias/etiologia , Qualidade de Vida , Procedimentos de Cirurgia Plástica/efeitos adversos , Recuperação de Função Fisiológica , Resultado do Tratamento
10.
J Bone Joint Surg Am ; 89(2): 261-9, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17272438

RESUMO

BACKGROUND: Proponents of navigated knee arthroplasty stress its potential to increase the precision of component placement. We conducted a systematic review and meta-analysis to substantiate the validity and relevance of this contention. METHODS: We searched major medical and publishers' databases for randomized trials and any other studies comparing navigated with conventional knee arthroplasty. Major periodicals were searched manually. We made no restrictions for types of studies or language. Methodological features were rated independently by two reviewers. After testing for publication bias and heterogeneity was done, the data were aggregated by random-effects modeling. We estimated the weighted mean differences of mechanical limb axes and functional scales and the risk ratios of deviations from the straight axis with 95% confidence intervals. RESULTS: We included thirty-three studies (eleven randomized trials) of varying methodological quality involving 3423 patients with a mean age (and standard deviation) of 67.3 +/- 4.1 years (62.6% were women, and 83.7% had primary osteoarthritis). The mean preoperative deviation from the mechanical axis was 2.3 degrees +/- 5.1 degrees. There was no evidence of publication bias, but there was strong statistical heterogeneity. The alignment of the mechanical axes did not differ between the navigated and conventional surgery group (weighted mean difference, 0.2 degrees; 95% confidence interval, -0.2 degrees to 0.5 degrees). Patients managed with navigated surgery had a lower risk of malalignment at critical thresholds of >3 degrees (risk ratio, 0.79; 95% confidence interval, 0.71 to 0.87) and >2 degrees (risk ratio, 0.76; 95% confidence interval, 0.71 to 0.82). No conclusive inferences could be drawn on functional outcomes or complication rates. Navigation lengthened the mean duration of surgery by 23%. CONCLUSIONS: Navigated knee replacement provides few advantages over conventional surgery on the basis of radiographic end points. Its clinical benefits are unclear and remain to be defined on a larger scale.


Assuntos
Artroplastia de Substituição/métodos , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Resultado do Tratamento
11.
BMC Surg ; 5: 1, 2005 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15723704

RESUMO

BACKGROUND: Ruptures of the anterior cruciate ligament (ACL) are common injuries to the knee joint. Arthroscopic ACL replacement by autologous tendon grafts has established itself as a standard of care. Data from both experimental and observational studies suggest that surgical reconstruction does not fully restore knee stability. Persisting anterior laxity may lead to recurrent episodes of giving-way and cartilage damage. This might at least in part depend on the method of graft fixation in the bony tunnels. Whereas resorbable screws are easy to handle, pins may better preserve graft tension. The objective of this study is to determine whether pinning of ACL grafts reduces residual anterior laxity six months after surgery as compared to screw fixation. DESIGN/METHODS: SPOT is a randomised, controlled, patient and investigator blinded trial conducted at a single academic institution. Eligible patients are scheduled to arthroscopic ACL repair with triple-stranded hamstring grafts, conducted by a single, experienced surgeon. Intraoperatively, subjects willing to engage in this study will be randomised to transplant tethering with either resorbable screws or resorbable pins. No other changes apply to locally established treatment protocols. Patients and clinical investigators will remain blinded to the assigned fixation method until the six-month follow-up examination. The primary outcome is the side-to-side (repaired to healthy knee) difference in anterior translation as measured by the KT-1000 arthrometer at a defined load (89 N) six months after surgery. A sample size of 54 patients will yield a power of 80% to detect a difference of 1.0 mm +/- standard deviation 1.2 mm at a two-sided alpha of 5% with a t-test for independent samples. Secondary outcomes (generic and disease-specific measures of quality of life, magnetic resonance imaging morphology of transplants and devices) will be handled in an exploratory fashion. CONCLUSION: SPOT aims at showing a reduction in anterior knee laxity after fixing ACL grafts by pins compared to screws.


Assuntos
Implantes Absorvíveis , Ligamento Cruzado Anterior/cirurgia , Pinos Ortopédicos , Parafusos Ósseos , Articulação do Joelho/cirurgia , Tendões/transplante , Artroscopia , Enxerto Osso-Tendão Patelar-Osso , Protocolos Clínicos , Feminino , Seguimentos , Humanos , Masculino , Transferência Tendinosa/métodos , Resultado do Tratamento
12.
J Orthop Trauma ; 16(8): 597-601, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12352570

RESUMO

This case report describes a Gustilo Anderson type IIIB tibia fracture associated with extensive segmental bone loss at the proximal meta-diaphyseal junction associated with a tibial plateau fracture and an avulsion of the tibial tubercle. After the tibial plateau fracture was stabilized using cannulated lag screws, the shaft fracture was stabilized using a statically locked intramedullary nail in combination with a cylindrical titanium mesh cage and cancellous bone graft. The soft tissue defect was covered with local flaps. Immediate full weight bearing was initiated, and early functional recovery was achieved. At the final follow-up, plain radiographs demonstrated excellent limb alignment, and bony healing with computed tomography examination revealed bony ingrowth through the cage. This technique may be a reasonable alternative in the treatment of segmental bone loss of long bones.


Assuntos
Diáfises/lesões , Diáfises/cirurgia , Fixação Intramedular de Fraturas , Fixadores Internos , Fraturas da Tíbia/cirurgia , Titânio/uso terapêutico , Adulto , Diáfises/fisiopatologia , Humanos , Masculino , Radiografia , Recuperação de Função Fisiológica/fisiologia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Índices de Gravidade do Trauma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA