Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Radiol ; 31(1): 76-84, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32740819

RESUMO

OBJECTIVES: To compare dynamic magnetic resonance imaging (MRI) with videofluoroscopy (VFS) regarding image quality and assessment of gap size between soft palate (SP) and posterior pharyngeal wall (PPW) in children and adolescents following surgical correction of velopharyngeal dysfunction (VPD). METHODS: Twenty-one patients undergoing unenhanced 3-T MRI and contrast-enhanced VFS were included in this IRB-approved prospective study. The MRI scan protocol comprised refocused gradient-echo sequences in transverse and sagittal planes during speech, with TE 1.97 ms, TR 3.95 ms, flip angle 8°, matrix size 128 × 128, and 5-mm slice thickness. Radial k-space sampling and sliding window reconstruction were used to achieve an image acquisition rate of 28 frames per second (fps). VFS with 30 fps was similarly performed in both planes. Closure of the velopharyngeal port during phonation was evaluated by two experienced radiologists. RESULTS: Eleven (52.4%) patients displayed a complete closure, whereas ten (47.6%) patients showed a post-operative gap during speech. VFS and MRI equally identified the cases with persistent or recurrent VPD. Differences in SP-PPW distance between VFS (3.9 ± 1.6 mm) and MRI (4.1 ± 1.5 mm) were not statistically significant (p = 0.5). The subjective overall image quality of MRI was rated inferior (p < 0.001) compared with VFS, with almost perfect inter-rater agreement (κ = 0.90). The presence of susceptibility artifacts did not limit anatomical measurements. CONCLUSION: Dynamic MRI is equally reliable as VFS to assess persistent or recurrent inadequate velum closure in patients following surgical treatment of VPD. KEY POINTS: • Unenhanced 3-T dynamic MRI and contrast-enhanced videofluoroscopy are equally useful for the identification of patients with incomplete velopharyngeal closure during speech. • MRI using refocused gradient-echo acquisition with radial k-space sampling and sliding window reconstruction generates diagnostic images with 28 frames per second. • MRI can offer a radiation-free alternative to currently established videofluoroscopy for young patients.


Assuntos
Insuficiência Velofaríngea , Adolescente , Criança , Humanos , Imageamento por Ressonância Magnética , Faringe/diagnóstico por imagem , Fonação , Estudos Prospectivos , Insuficiência Velofaríngea/diagnóstico por imagem , Insuficiência Velofaríngea/cirurgia
2.
Clin Radiol ; 73(9): 833.e19-833.e27, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29884524

RESUMO

AIM: To investigate the impact of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on quantitative and qualitative image parameters in patients with malignant lymphoma at dual-energy computed tomography (DECT) examinations of the abdomen. MATERIALS AND METHODS: Thirty-five consecutive patients (mean age, 53.8±18.6 years; range, 21-82 years) with histologically proven malignant lymphoma of the abdomen were included retrospectively. Images were post-processed with standard linear blending (M_0.6), traditional VMI, and VMI+ technique at energy levels ranging from 40 to 100 keV in 10 keV increments. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were objectively measured in lymphoma lesions. Image quality, lesion delineation, and image noise were rated subjectively by three blinded observers using five-point Likert scales. RESULTS: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 15.77±7.74; CNR, 18.27±8.04) with significant differences compared to standard linearly blended M_0.6 (SNR, 7.96±3.26; CNR, 13.55±3.47) and all traditional VMI series (p<0.001). Qualitative image quality assessment revealed significantly superior ratings for image quality at 60-keV VMI+ (median, 5) in comparison with all other image series (p<0.001). Assessment of lesion delineation showed the highest rating scores for 40-keV VMI+ series (median, 5), while lowest subjective image noise was found for 100-keV VMI+ reconstructions (median, 5). CONCLUSION: Low-keV VMI+ reconstructions led to improved image quality and lesion delineation of malignant lymphoma lesions compared to standard image reconstruction and traditional VMI at abdominal DECT examinations.


Assuntos
Abdome/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Linfoma/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
3.
Eur J Radiol ; 86: 20-25, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027748

RESUMO

PURPOSE: To evaluate the impact of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) volume interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) technique on image quality, reader confidence, and inter-observer agreement for the assessment of focal liver lesions in comparison with the standard VIBE approach. MATERIAL AND METHODS: In this IRB-approved intra-individual comparison study, abdominal arterial and portal-venous contrast-enhanced MRI studies were retrospectively analyzed in 38 patients with malignant liver lesions. Each patient underwent both CAIPIRINHA and conventional VIBE 3T MRI within 3 months, showing stable disease. Images were evaluated using 5-point rating scales by two blinded radiologists with more than 20 and 5 years of experience in MRI, respectively. Readers scored dignity of liver lesions and assessed which liver segments were affected by malignancy (ranging from 1=definitely benign/not affected to 5=definitely malignant/affected by malignancy). Readers also rated overall image quality, sharpness of intrahepatic veins, and diagnostic confidence (ranging from 1=poor to 5=excellent). RESULTS: Reviewers achieved a higher inter-observer reliability using CAIPIRINHA when they reported which liver segments were affected by malignancy compared to traditional VIBE series (κ=0.62 and 0.54, respectively, p<0.05). Similarly, CAIPIRINHA showed a slightly higher inter-rater agreement for the dignity of focal liver lesions versus the standard VIBE images (κ=0.50 and 0.49, respectively, p<0.05). CAIPIRINHA series also scored higher in comparison to standard VIBE sequences (mean scores: image quality, 4.2 and 3.5; sharpness of intrahepatic vessels, 3.8 and 3.2, respectively, p<0.05) for both reviewers and allowed for higher subjective diagnostic confidence (ratings, 3.8 and 3.2, respectively, p<0.05). CONCLUSION: Compared to the standard VIBE approach, CAIPIRINHA VIBE technique provides improved image quality and sharpness of intrahepatic veins, as well as higher diagnostic confidence. Additionally, this technique allows for higher inter-observer agreement when reporting focal liver lesions for both dignity and allocation.


Assuntos
Hepatopatias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Suspensão da Respiração , Meios de Contraste , Feminino , Artéria Hepática/patologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veia Porta/patologia , Reprodutibilidade dos Testes
4.
AJNR Am J Neuroradiol ; 37(1): 143-50, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26427836

RESUMO

BACKGROUND AND PURPOSE: Dose-saving techniques in neck CT cause increased image noise that can be counteracted by iterative reconstruction. Our aim was to evaluate the image quality of advanced modeled iterative reconstruction (ADMIRE) in contrast-enhanced low-tube-voltage neck CT. MATERIALS AND METHODS: Sixty-one patients underwent 90-kV(peak) neck CT by using third-generation 192-section dual-source CT. Image series were reconstructed with standard filtered back-projection and ADMIRE strength levels 1, 3, and 5. Attenuation and noise of the sternocleidomastoid muscle, internal jugular vein, submandibular gland, tongue, subscapularis muscle, and cervical fat were measured. Signal-to-noise and contrast-to-noise ratios were calculated. Two radiologists assessed image noise, image contrast, delineation of smaller structures, and overall diagnostic acceptability. Interobserver agreement was calculated. RESULTS: Image noise was significantly reduced by using ADMIRE compared with filtered back-projection with the lowest noise observed in ADMIRE 5 (filtered back-projection, 9.4 ± 2.4 Hounsfield units [HU]; ADMIRE 1, 8.3 ± 2.8 HU; ADMIRE 3, 6.7 ± 2.0 HU; ADMIRE 5, 5.4 ± 1.7 HU; all, P < .001). Sternocleidomastoid SNR and internal jugular vein-sternocleidomastoid contrast-to-noise ratios were significantly higher for ADMIRE with the best results in ADMIRE 5 (all, P < .001). Subjective image quality and image contrast of ADMIRE 3 and 5 were consistently rated better than those for filtered back-projection and ADMIRE 1 (all, P < .001). Image noise was rated highest for ADMIRE 5 (all, P < .005). Delineation of smaller structures was voted higher in all ADMIRE strength levels compared with filtered back-projection (P < .001). Global interobserver agreement was good (0.75). CONCLUSIONS: Contrast-enhanced 90-kVp neck CT is feasible, and ADMIRE 5 shows superior objective image quality compared with filtered back-projection. ADMIRE 3 and 5 show the best subjective image quality.


Assuntos
Algoritmos , Meios de Contraste , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Pescoço/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
5.
Clin Radiol ; 70(8): e67-73, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26050533

RESUMO

AIM: To evaluate neck computed tomography (CT) with a reduced tube voltage of 80 kVp in patients with suspected peritonsillar abscess (PTA) regarding objective and subjective image quality, and the potential for dose reduction. MATERIALS AND METHODS: Forty-seven patients with clinically suspected PTA were retrospectively analysed. Patients were examined using dual-source CT in dual-energy mode. The objective and subjective image quality of 80 kVp images were compared with linearly blended 120 kVp images (M_0.3; 30% of 80 kV, 70% of 140 kV spectrum). Attenuation of abscess rim enhancement, central necrosis, and several other anatomical landmarks were measured. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and rim-to-abscess CNR (raCNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed according to the European guidelines on quality criteria for CT. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC). RESULTS: Attenuation of inflamed soft tissue (141.7 ± 16.3 versus 93.7 ± 9.3 HU, p < 0.001), CNR (9.6 ± 4.8 versus 5.6 ± 3.8, p = 0.001), raCNR (14.3 ± 5.9 versus 12.4 ± 4.4, p = 0.02), and subjective image sharpness (3.6 ± 0.6 versus 2.8 ± 0.7, p < 0.001) were significantly increased in the 80 kVp compared to 120 kVp, whereas subjective and objective image noise were significantly increased with 80 kVp acquisition (p < 0.001). Overall interobserver agreement was almost perfect (ICC, 0.87). Calculated SSDE of 80 kVp acquisition was decreased by 49.7% compared to 120 kVp (10.58 ± 0.76 versus 21.04 ± 1.43 mGy, p < 0.001). CONCLUSION: Low-tube-voltage 80 kVp neck CT provides increased enhancement of soft-tissue inflammation, CNR, raCNR, and improved abscess delineation in patients with PTA compared to standard 120 kVp acquisition while resulting in a significant reduction of radiation exposure.


Assuntos
Abscesso Peritonsilar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
6.
Clin Radiol ; 70(7): 711-5, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25912259

RESUMO

AIM: To evaluate the diagnostic image quality and radiation dose of low-dose 70 kV computed tomography (CT) of the paranasal sinus in comparison to 100 and 120 kV CT. MATERIALS AND METHODS: CT of the paranasal sinus was performed in 127 patients divided into three groups using different tube voltages and currents (70 kV/75 mAs, ultra-low dose protocol, n = 44; 100 kV/40 mAs, standard low-dose protocol, n = 42; 120 kV/40 mAs, standard protocol, n = 41). CT dose index (CTDIvol), dose-length product (DLP), attenuation, image noise and signal-to-noise ratio (SNR) were compared between the groups using Wilcoxon-Mann-Whitney U-test. Subjective diagnostic image quality was compared by using a five-point scale (1 = non-diagnostic, 5 = excellent, read by two readers in consensus) and Cohen's weighted kappa analysis for interobserver agreement. RESULTS: Radiation dose was significantly lower with 70 kV acquisition than 100 and 120 kV (DLP: 31 versus 52 versus 82 mGy·cm; CTDI 2.33 versus 3.95 versus 6.31 mGy, all p < 0.05). Mean SNR (70 kV: 0.37; 100 kV: 0.21; 120 kV: 0.13; p < 0.05) and organ attenuation increased significantly with lower voltages. All examinations showed diagnostic image quality. Subjective diagnostic image quality was higher with standard protocols than the 70 kV protocol (120 kV: 5.0; 100 kV: 4.5; 70 kV: 3.5, p < 0.05) without significant differences with substantial interobserver agreement (κ > 0.59). CONCLUSION: The ultra-low dose (70 kV) CT imaging of the paranasal sinus allowed for significant dose reduction by 61% and an increased attenuation of organ structures in comparison to standard acquisition while maintaining diagnostic image quality with a slight reduction in subjective image quality.


Assuntos
Doenças dos Seios Paranasais/diagnóstico por imagem , Seios Paranasais/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Clin Radiol ; 70(2): 168-75, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25491926

RESUMO

AIM: To compare non-linear and linear image-blending post-processing techniques in dual-energy CT (DECT) of primary head and neck squamous cell carcinoma (SCC) regarding subjective and objective image quality. MATERIALS AND METHODS: Head and neck DECT studies from 69 patients (48 male, 21 female; mean age 62.3 years) were retrospectively evaluated. All tumour lesions were histologically confirmed SCC. Linearly blended 80/140 kVp images series with varying weighting factors of 0.3 (M_0.3), 0.6 and 0.8 were compared with non-linearly blended images. Attenuation of tumour lesion, various soft-tissue structures, the internal jugular vein, and image noise were measured, tumour signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Overall image quality, delineation of tumour lesion, image sharpness, and noise level were rated individually by three radiologists using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Enhancement of tumour lesions (non-linear, 137.5 ± 20.1 HU; M_0.3, 92.7 ± 14.4 HU; M_0.6, 110 ± 15.4 HU; M_0.8, 123 ± 18.2 HU), CNR (non-linear, 12 ± 8; M_0.3, 4 ± 4.7; M_0.6, 7.5 ± 5.5; M_0.8, 8 ± 5.5), subjective overall image quality and tumour delineation were significantly increased (all p < 0.001) with the non-linear blending technique compared to all investigated linear blending weighting factors. Overall interobserver agreement was substantial (ICC 0.70; 95% CI: 0.66-0.73). CONCLUSION: Post-processing of DECT using a non-linear blending technique provides improved objective and subjective image quality of head and neck SCC compared to linearly blended images series.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
8.
AJNR Am J Neuroradiol ; 35(12): 2376-81, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25104285

RESUMO

BACKGROUND AND PURPOSE: Low-tube-voltage acquisition has been shown to facilitate substantial dose savings for neck CT with similar image contrast compared with standard 120-kVp acquisition. However, its potential for the detection of neck pathologies is uncertain. Our aim was to evaluate the effects of low-tube-voltage 80-kV(peak) acquisitions for neck CT on diagnostic accuracy and interobserver agreement. MATERIALS AND METHODS: Three radiologists individually analyzed 80-kVp and linearly blended 120-kVp image series of 170 patients with a variety of pathologies who underwent dual-energy neck CT. Reviewers were unblinded to the clinical indication for CT but were otherwise blinded to any other data or images and were asked to state a final main diagnosis. Findings were compared with medical record charts, CT reports, and pathology results. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for each observer. Interobserver agreement was evaluated by using intraclass correlation coefficients. RESULTS: Diagnoses were grouped as squamous cell carcinoma-related (n = 107, presence/absence of primary/recurrent squamous cell carcinoma), lymphoma-related (n = 40, presence/absence of primary/recurrent lymphoma), and benign (n = 23, eg, abscess). Cumulative sensitivity, specificity, positive predictive value, and negative predictive value for 80-kVp and blended 120-kVp images were 94.8%, 93.0%, 95.9%, and 91.1%, respectively. Results were also consistently high for squamous cell carcinoma-related (94.8%/95.3%, 89.1%/89.1%, 94.3%/94.4%, 90.1%/91.0%) and lymphoma-related (95.0%, 100.0%, 100.0%, 95.2%) 80-kVp/120-kVp image series. Global interobserver agreement was almost perfect (intraclass correlation coefficient, 0.82, 0.80; 95% CI, 0.76-0.74, 0.86-0.85). Calculated dose-length product was reduced by 48% with 80-kVp acquisitions compared with the standard 120-kVp scans (135.5 versus 282.2 mGy × cm). CONCLUSIONS: Low-tube-voltage 80-kVp CT of the neck provides sufficient image quality with high diagnostic accuracy in routine clinical practice and has the potential to substantially decrease radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Variações Dependentes do Observador , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Abscesso/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Sensibilidade e Especificidade , Adulto Jovem
9.
AJNR Am J Neuroradiol ; 35(3): 445-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24263695

RESUMO

BACKGROUND AND PURPOSE: Acute intracranial hemorrhage represents a severe and time critical pathology that requires precise and quick diagnosis, mainly by performing a CT scan. The purpose of this study was to compare image quality and intracranial hemorrhage conspicuity in brain CT with sinogram-affirmed iterative reconstruction and filtered back-projection reconstruction techniques at standard (340 mAs) and low-dose tube current levels (260 mAs). MATERIALS AND METHODS: A total of 94 consecutive patients with intracranial hemorrhage received CT scans either with standard or low-dose protocol by random assignment. Group 1 (n=54; mean age, 64 ± 20 years) received CT at 340 mAs, and group 2 (n=40; mean age, 57 ± 23 years) received CT at 260 mAs. Images of both groups were reconstructed with filtered back-projection reconstruction and 5 iterative strengths (S1-S5) and ranked blind by 2 radiologists for image quality and intracranial hemorrhage on a 5-point scale. Image noise, SNR, dose-length product (mGycm), and mean effective dose (mSv) were calculated. RESULTS: In both groups, image quality and intracranial hemorrhage conspicuity were rated subjectively with an excellent/good image quality. A higher strength of sinogram-affirmed iterative reconstruction showed an increase in image quality with a difference to filtered back-projection reconstruction (P < .05). Subjective rating showed the best score of image quality and intracranial hemorrhage conspicuity achieved through S3/S4-5. Objective analysis of image quality showed in an increase of SNR with a higher strength of sinogram-affirmed iterative reconstruction. Patients in group 2 (mean: 744 mGycm/1.71 mSv) were exposed to a significantly lower dose than those in group 1 (mean: 1045 mGycm/2.40 mSv, P < .01). CONCLUSIONS: S3 provides better image quality and visualization of intracranial hemorrhage in brain CT at 260 mAs. Dose reduction by almost one-third is possible without significant loss in diagnostic quality.


Assuntos
Interpretação de Imagem Assistida por Computador , Hemorragias Intracranianas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...