Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Radiother Oncol ; : 110365, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38830538

RESUMO

Compared to conventional radiotherapy using X-rays, proton therapy, in principle, allows better conformity of the dose distribution to target volumes, at the cost of greater sensitivity to physical, anatomical, and positioning uncertainties. Robust planning, both in terms of plan optimization and evaluation, has gained high visibility in publications on the subject and is part of clinical practice in many centers. However, there is currently no consensus on the methods and parameters to be used for robust optimization or robustness evaluation. We propose to overcome this deficiency by following the modified Delphi consensus method. This method first requires a systematic review of the literature. We performed this review using the PubMed and Web Of Science databases, via two different experts. Potential conflicts were resolved by a third expert. We then explored the different methods before focusing on clinical studies that evaluate robustness on a significant number of patients. Many robustness assessment methods are proposed in the literature. Some are more successful than others and their implementation varies between centers. Moreover, they are not all statistically or mathematically equivalent. The most sophisticated and rigorous methods have seen more limited application due to the difficulty of their implementation and their lack of widespread availability.

2.
Acta Oncol ; 58(9): 1238-1245, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31155998

RESUMO

Background and purpose: Recurrent nasopharyngeal carcinoma (NPC) has limited curative treatment options. Reirradiation is the only potential definitive treatment in advanced stages at a cost of substantial severe and often life-threatening toxicity. Proton therapy (PT) reduces irradiated volume compared with X-ray radiotherapy and could be advantageous in terms of safety and efficacy in a population of heavily pretreated patients. We report the retrospective results of PT reirradiation in recurrent NPC patients treated at our Institution Methods: All recurrent NPC patients treated since the beginning of clinical activity entered the present analysis. Clinical target volume consisted of Gross Tumor volume plus a patient-specific margin depending on disease behavior, tumor location, proximity of organs at risk, previous radiation dose. No elective nodal irradiation was performed. Active scanning technique with the use of Single Field Optimization (SFO) or Multifield Optimization (MFO) was adopted. Cumulative X-ray -PT doses were calculated for all patients using a dose accumulation tool since 2016. Treatment toxicity was retrospectively collected. Results: Between February 2015, and October 2018, 17 recurrent NPC patients were treated. Median follow-up (FUP) was 10 months (range 2-41). Median PT reirradiation dose was 60 Gy RBE (range 30.6-66). The majority of patients (53%) underwent concomitant chemotherapy. Acute toxicity was low with no ≥ G3 adverse events. Late events ≥ G3 occurred in 23.5% of patients. Most frequent late toxicity was hearing impairment (17,6%). G2 soft tissue necrosis occurred in two patients. Fatal bleeding of uncertain cause (either tumor recurrence or G5 carotid blowout) occurred in one patient. Kaplan-Meier 18 months Overall Survival (OS) and Local control (LC) rates were 54.4% and 66.6%, respectively. Conclusions: Our initial results with the use of modern PT for reirradiation of recurrent NPC patients are encouraging. Favorable LC and OS rates were obtained at the cost of acceptable severe late toxicity.


Assuntos
Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Recidiva Local de Neoplasia/radioterapia , Terapia com Prótons/métodos , Reirradiação/métodos , Adulto , Idoso , Quimioterapia Adjuvante , Feminino , Audição/efeitos da radiação , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Carcinoma Nasofaríngeo/tratamento farmacológico , Carcinoma Nasofaríngeo/patologia , Neoplasias Nasofaríngeas/tratamento farmacológico , Neoplasias Nasofaríngeas/patologia , Recidiva Local de Neoplasia/tratamento farmacológico , Recidiva Local de Neoplasia/patologia , Órgãos em Risco , Terapia com Prótons/efeitos adversos , Dosagem Radioterapêutica , Reirradiação/efeitos adversos , Estudos Retrospectivos , Carga Tumoral
3.
Phys Med Biol ; 60(21): 8601-19, 2015 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-26501569

RESUMO

We propose a method of creating and validating a Monte Carlo (MC) model of a proton Pencil Beam Scanning (PBS) machine using only commissioning measurements and avoiding the nozzle modeling. Measurements with a scintillating screen coupled with a CCD camera, ionization chamber and a Faraday Cup were used to model the beam in TOPAS without using any machine parameter information but the virtual source distance from the isocenter. Then the model was validated on simple Spread Out Bragg Peaks (SOBP) delivered in water phantom and with six realistic clinical plans (many involving 3 or more fields) on an anthropomorphic phantom. In particular the behavior of the moveable Range Shifter (RS) feature was investigated and its modeling has been proposed. The gamma analysis (3%,3 mm) was used to compare MC, TPS (XiO-ELEKTA) and measured 2D dose distributions (using radiochromic film). The MC modeling proposed here shows good results in the validation phase, both for simple irradiation geometry (SOBP in water) and for modulated treatment fields (on anthropomorphic phantoms). In particular head lesions were investigated and both MC and TPS data were compared with measurements. Treatment plans with no RS always showed a very good agreement with both of them (γ-Passing Rate (PR) > 95%). Treatment plans in which the RS was needed were also tested and validated. For these treatment plans MC results showed better agreement with measurements (γ-PR > 93%) than the one coming from TPS (γ-PR < 88%). This work shows how to simplify the MC modeling of a PBS machine for proton therapy treatments without accounting for any hardware components and proposes a more reliable RS modeling than the one implemented in our TPS. The validation process has shown how this code is a valid candidate for a completely independent treatment plan dose calculation algorithm. This makes the code an important future tool for the patient specific QA verification process.


Assuntos
Algoritmos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Método de Monte Carlo , Dosagem Radioterapêutica
4.
Br J Radiol ; 84(999): 271-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21045069

RESUMO

OBJECTIVES: Delineation of clinical target volume (CTV) is still controversial in glioblastomas. In order to assess the differences in volume and shape of the radiotherapy target, the use of pre-operative vs post-operative/pre-radiotherapy T(1) and T(2) weighted MRI was compared. METHODS: 4 CTVs were delineated in 24 patients pre-operatively and post-operatively using T(1) contrast-enhanced (T1(PRE)CTV and T1(POST)CTV) and T(2) weighted images (T2(PRE)CTV and T2(POST)CTV). Pre-operative MRI examinations were performed the day before surgery, whereas post-operative examinations were acquired 1 month after surgery and before chemoradiation. A concordance index (CI) was defined as the ratio between the overlapping and composite volumes. RESULTS: The volumes of T1(PRE)CTV and T1(POST)CTV were not statistically different (248 ± 88 vs 254 ± 101), although volume differences >100 cm(3) were observed in 6 out of 24 patients. A marked increase due to tumour progression was shown in three patients. Three patients showed a decrease because of a reduced mass effect. A significant reduction occurred between pre-operative and post-operative T(2) volumes (139 ± 68 vs 78 ± 59). Lack of concordance was observed between T1(PRE)CTV and T1(POST)CTV (CI = 0.67 ± 0.09), T2(PRE)CTV and T2(POST)CTV (CI = 0.39 ± 0.20) and comparing the portion of the T1(PRE)CTV and T1(POST)CTV not covered by that defined on T2(PRE)CTV images (CI = 0.45 ± 0.16 and 0.44 ± 0.17, respectively). CONCLUSION: Using T(2) MRI, huge variations can be observed in peritumoural oedema, which are probably due to steroid treatment. Using T(1) MRI, brain shifts after surgery and possible progressive enhancing lesions produce substantial differences in CTVs. Our data support the use of post-operative/pre-radiotherapy T(1) weighted MRI for planning purposes.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioblastoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Feminino , Glioblastoma/patologia , Glioblastoma/cirurgia , Humanos , Masculino , Variações Dependentes do Observador , Período Pós-Operatório , Período Pré-Operatório , Lesões por Radiação/prevenção & controle , Reprodutibilidade dos Testes , Carga Tumoral
5.
Phys Med Biol ; 53(6): 1665-75, 2008 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-18367795

RESUMO

We investigated the role and the weight of the parameters involved in the intensity modulated radiation therapy (IMRT) optimization based on the generalized equivalent uniform dose (gEUD) method, for prostate and head-and-neck plans. We systematically varied the parameters (gEUDmax and weight) involved in the gEUD-based optimization of rectal wall and parotid glands. We found that the proper value of weight factor, still guaranteeing planning treatment volumes coverage, produced similar organs at risks dose-volume (DV) histograms for different gEUDmax with fixed a=1. Most of all, we formulated a simple relation that links the reference gEUDmax and the associated weight factor. As secondary objective, we evaluated plans obtained with the gEUD-based optimization and ones based on DV criteria, using the normal tissue complication probability (NTCP) models. gEUD criteria seemed to improve sparing of rectum and parotid glands with respect to DV-based optimization: the mean dose, the V40 and V50 values to the rectal wall were decreased of about 10%, the mean dose to parotids decreased of about 20-30%. But more than the OARs sparing, we underlined the halving of the OARs optimization time with the implementation of the gEUD-based cost function. Using NTCP models we enhanced differences between the two optimization criteria for parotid glands, but no for rectum wall.


Assuntos
Doses de Radiação , Radiobiologia , Planejamento da Radioterapia Assistida por Computador/métodos , Cabeça/efeitos da radiação , Humanos , Masculino , Pescoço/efeitos da radiação , Probabilidade , Próstata/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Reprodutibilidade dos Testes
6.
Eur J Cardiothorac Surg ; 21(6): 995-1001, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12048076

RESUMO

OBJECTIVE: Intermittent warm blood cardioplegia (IWBC) is a well-established technique for myocardial protection during cardiac operations. According to standardized protocols, IWBC administration is currently performed every 15-20 min regardless of any individual variable and in the absence of any instrumental monitoring. We devised a new system for continuous measurement of the acid-base status of coronary sinus blood for on-line evaluation of myocardial oxygenation during IWBC. METHODS: In 19 patients undergoing cardiac surgery for coronary artery bypass graft and/or valve surgery and receiving IWBC (34-37 degrees C) by antegrade induction (3 min) and retrograde or antegrade maintenance (2 min) every 15 min, continuous monitoring of myocardial oxygenation and acid/base status was performed by means of a multiparameter PO(2), PCO(2), pH, and temperature sensor (Paratrend7 (R), Philips Medical System) inserted into the coronary sinus. RESULTS: Mean cross-clamping time was 76+/-26 min; ischemic time was 13+/-0.2 min. pH decline was not linear, showing an initial fast decline, a point of flexus, and a progressive slow decline. After every ischemic period, the pH adaptation curve showed a complex pattern reaching step-by-step lower minimum levels (7.28+/-0.14 during the first ischemic period, to 7.16+/-0.19 during the third ischemic period - P=0.003). PO(2) decreased rapidly at 90% in 5.0+/-1.2 min after every reperfusion. During ischemia, PCO(2) increased steadily at 1.6+/-0.1 mmHg per minute, with progressively incomplete removal after successive reperfusion, and progressive increase of maximal level (42+/-12 mmHg during the first ischemic period, to 53+/-23 mmHg during the third ischemic period - P=0.05). CONCLUSIONS: Myocardial oxygen, carbon dioxide, and pH show marked changes after repeated IWBC. Myocardial ischemia is not completely reversed by standardized reperfusions, as reflected by steady deterioration of PCO(2) and pH after each reperfusion. Progressive increase of reperfusion durations or direct monitoring of myocardial oxygenation could be advisable in cases of prolonged cross-clamping time.


Assuntos
Equilíbrio Ácido-Base , Parada Cardíaca Induzida , Monitorização Intraoperatória , Miocárdio/metabolismo , Idoso , Sangue , Dióxido de Carbono/sangue , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Vasos Coronários , Feminino , Parada Cardíaca Induzida/métodos , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...