Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Clin Med ; 13(6)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38541884

RESUMO

Background: Cushing's disease (CD) is associated with a specific form of metabolic syndrome that includes visceral obesity, which may affect cardiovascular hemodynamics by stimulating hypercortisolism-related metabolic activity. The purpose of this study was to evaluate the relationship between obesity and the hemodynamic profile of patients with CD. Methods: This prospective clinical study involved a hemodynamic status assessment of 54 patients newly diagnosed with CD with no significant comorbidities (mean age of 41 years). The assessments included impedance cardiography (ICG) to assess such parameters as stroke index (SI), cardiac index (CI), velocity index (VI), acceleration index (ACI), Heather index (HI), systemic vascular resistance index (SVRI), and total arterial compliance index (TACI) as well as applanation tonometry to assess such parameters as central pulse pressure (CPP) and augmentation index (AI). These assessments were complemented by echocardiography to assess cardiac structure and function. Results: Compared with CD patients without obesity, individuals with CD and obesity (defined as a body mass index ≥ 30 kg/m2) exhibited significantly lower values of ICG parameters characterizing the pumping function of the heart (VI: 37.0 ± 9.5 vs. 47.2 ± 14.3 × 1*1000-1*s-1, p = 0.006; ACI: 58.7 ± 23.5 vs. 76.0 ± 23.5 × 1/100/s2, p = 0.005; HI: 11.1 ± 3.5 vs. 14.6 ± 5.5 × Ohm/s2, p = 0.01), whereas echocardiography in obese patients showed larger heart chamber sizes and a higher left ventricular mass index. No significant intergroup differences in blood pressure, heart rate, LVEF, GLS, TACI, CPP, or AI were noted. Conclusions: Hemodynamic changes associated with obesity already occur at an early stage of CD and manifest via significantly lower values of the ICG parameters illustrating the heart's function as a pump, despite the normal function of the left ventricle in echocardiography.

2.
J Clin Med ; 13(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38256528

RESUMO

BACKGROUND: Acromegaly is a rare, chronic disease that involves structural and functional abnormalities of the cardiovascular system. Acromegaly likely affects interactions between the cardiovascular system and the autonomic nervous system (ANS). Therefore, assessing the relationship between sympathetic-parasympathetic balance by analyzing heart rate variability (HRV) and the hemodynamic profile via impedance cardiography (ICG) may be useful in learning the exact nature of interactions between the ANS and the cardiovascular system. The purpose of this study was to assess a possible association between HRV and ICG-based parameters of cardiac function in patients newly diagnosed with acromegaly. METHODS: This observational cohort study was conducted on 33 patients (18 men, mean age of 47 years) newly diagnosed with acromegaly and no significant comorbidities. A correlation analysis (Spearman's rank coefficient R) of the parameters assessed via ICG and the HRV assessed via 24 h ambulatory electrocardiography was performed. ICG assessments included the following parameters: stroke volume index (SI), cardiac index (CI), acceleration index (ACI), velocity index (VI), and Heather index (HI). The analysis of HRV included both time-domain parameters (pNN50, SDNN, SDSD, rMSSD) and frequency-domain parameters (total power (TP) and its individual frequency bands: low-frequency (LF day/night), high-frequency (HF day/night), and the LF/HF ratio (day/night)). RESULTS: Frequency-domain HRV analysis showed the following correlations: (1) lower nighttime LF values with higher ACI (R = -0.38; p = 0.027) and HI (R = -0.46; p = 0.007) values; (2) higher nighttime HF values with higher ACI (R = 0.39; p = 0.027) and HI (R = 0.43; p = 0.014) values; (3) lower nighttime LF/HF values with higher ACI (R = -0.36; p = 0.037) and HI (R = -0.42; p = 0.014) values; (4) higher nighttime TP values with higher SI values (R = 0.35; p = 0.049). Time-domain parameters of HRV showed a significant correlation only between the nighttime values of SDSD and SI (R = 0.35; p = 0.049) and between the daytime and nighttime values of SDNN and HR (R = -0.50; p = 0.003 and R = -0.35; p = 0.046). In multivariate regression, only ACI was revealed to be independently related to HRV. CONCLUSIONS: In patients newly diagnosed with acromegaly, the relationship between the sympathetic-parasympathetic balance assessed via HRV and the hemodynamic profile assessed via ICG was revealed. Better function of the left ventricle was associated with a parasympathetic shift in the autonomic balance.

3.
Front Endocrinol (Lausanne) ; 14: 1270455, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37886640

RESUMO

Background: Cushing disease (CD) may lead to accelerated cardiovascular remodeling and increased mortality. There are suspected differences in the mechanism of cardiovascular dysfunction between males and females with CD. The purpose of this study was to assess the effect of patient sex on the hemodynamic profile assessed via impedance cardiography and echocardiography in patients newly diagnosed with CD. Material and methods: The 54 patients newly diagnosed with CD (mean age 41 years; 77.8% of females) who were included in this prospective clinical study underwent impedance cardiography to assess specific parameters (including systemic vascular resistance index [SVRI], total arterial compliance index [TACI], Heather index [HI], stroke index [SI], cardiac index [CI], velocity index [VI], and acceleration index [ACI]) and transthoracic echocardiography to assess heart chamber diameters and left ventricular systolic and diastolic function. Results: Males with CD exhibited higher afterload, with higher SVRI (3,169.3 ± 731.8 vs. 2,339.3 ± 640.8 dyn*s*cm-5*m² in males and females, respectively; p=0.002), lower TACI (0.80 ± 0.30 vs. 1.09 ± 0.30 mL/mmHg*m2; p=0.008), and lower hemodynamic parameters of left ventricular function, with lower HI (9.46 ± 2.86 vs. 14.1 ± 5.06 Ohm/s2; p=0.0007), lower VI (35.1 ± 11.9 vs. 44.9 ± 13.1 1*1000-1*s-1; p=0.009), lower SI (36.5 ± 11.7 vs. 43.6 ± 9.57 mL/m2; p=0.04), lower CI (2.36 ± 0.46 vs. 3.17 ± 0.76 mL*m-2*min-1; p=0.0009), and lower ACI (50.4 ± 19.8 vs. 73.6 ± 25.0 1/100/s2; p=0.006). There were no significant differences between the sexes in left ventricular systolic or diastolic function assessed by echocardiography. Conclusion: In comparison with females with CD, males with CD have a less favorable hemodynamic profile, with higher afterload and worse left ventricular function. Sex differences in cardiovascular system function should be taken into consideration in designing personalized diagnostic and therapeutic management of patients with CD.


Assuntos
Hipersecreção Hipofisária de ACTH , Humanos , Masculino , Feminino , Adulto , Estudos Prospectivos , Hemodinâmica , Coração , Ecocardiografia
4.
J Clin Med ; 12(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37373726

RESUMO

This study tested the relationship between left atrial (LA) function parameters and the results of pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Consecutive patients undergoing PVI for the first time between 2019 and 2021 were included. Patients underwent radiofrequency ablation using contact force catheters and an electroanatomical system. Follow-up consisted of ambulatory visits/televisits and 7-day Holter monitoring (at 6 and 12 months after ablation). On the day of ablation, all patients underwent transesophageal and transthoracic echocardiography with LA strain analysis. The primary endpoint was atrial tachyarrhythmia recurrence during the follow-up period. Of 221 patients, 22 did not meet the echocardiographic quality criteria, leaving 199 patients. The median follow-up period was 12 months, and 12 patients were lost to follow-up. Recurrences were observed in 67 patients (35.8%) after a mean of 1.06 procedures per patient. The patients were divided into a sinus rhythm (SR, n = 109) group and an AF (n = 90) group based on their cardiac rhythm at the time of echocardiography. In the SR group, univariable analysis showed that LA reservoir strain, LA appendage emptying velocity (LAAV), and LA volume index predicted AF recurrence, with only LAAV being significant in the multivariable analysis. In AF patients, univariable analysis revealed no LA strain parameters predicting AF recurrence.

5.
Nutrients ; 14(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36558529

RESUMO

Hyperprolactinemia in males with prolactin-secreting adenomas, or prolactinomas, may be associated with endothelial dysfunction and co-existing cardiovascular risk factors. As a noninvasive technique of assessing cardiac function, impedance cardiography (ICG) may be useful in the early detection of hemodynamic dysfunction. The aim of the present study was to analyze and compare the hemodynamic profiles of patients with prolactinoma versus controls. A total of 20 men with prolactinoma (PR group) (mean age 43 years) and 20 men from the control group (CG) were evaluated in this prospective, observational comparative clinical study. The study subjects were propensity score-matched in terms of clinical characteristics­age, mean blood pressure [MBP], arterial hypertension [AH] rates, and body mass index [BMI]. ICG assessments of hemodynamic profiles were conducted with the use of a Niccomo™ device and included stroke volume index (SI), cardiac index (CI), systemic vascular resistance index (SVRI), velocity index (VI), acceleration index (ACI), Heather index (HI), and thoracic fluid content (TFC). AH was well-controlled in both study groups (116/76 mmHg PR vs. 119/76 mmHg CG). In comparison with CG patients, ICG revealed PR group patients to have higher rates of high thoracic fluid content (TFC) (>35 1/kOhm; p = 0.035) and lower SI values (<35 mL/m2, p = 0.072). There was a convergent tendency towards lower values of other cardiac function parameters (SI, CI, VI, ACI, and HI). Prolactinoma-associated endocrine abnormalities are related to hemodynamic profile alterations, including higher rates of increased TFC and the risk of worsened cardiac function.


Assuntos
Hipertensão , Neoplasias Hipofisárias , Prolactinoma , Masculino , Humanos , Adulto , Prolactinoma/complicações , Estudos Prospectivos , Hemodinâmica/fisiologia , Neoplasias Hipofisárias/complicações
6.
J Clin Med ; 11(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35807052

RESUMO

BACKGROUND: Autonomic nervous system (ANS) dysfunction is an important factor in the development and progression of arterial hypertension (AH) and may produce adverse hemodynamic sequelae. ANS function can be evaluated by analyzing heart rate variability (HRV). The purpose of this study was to assess the possible correlation between HRV and the hemodynamic profile of AH patients, including antihypertensive treatment effects after 12 months. METHODS: The study was conducted on 144 patients with uncomplicated AH. The hemodynamic profile was assessed via echocardiography and impedance cardiography (ICG). The analyzed HRV parameters included SDNN, rMSSD, pNN50, low frequency (LF, 0.05-0.15 Hz), high frequency (HF, 0.15-0.4 Hz), total power (TP, the variance of all NN intervals), and the day, night, and 24-h low-to-high frequency ratios (LF/HF). RESULTS: Analysis showed various correlations of HRV parameters both with arterial blood pressure and with the hemodynamic profile assessed via echocardiography and ICG. The HRV parameters of increased ANS activity showed a correlation with improved left ventricle function (LV) and lower LV afterload. CONCLUSIONS: Effective antihypertensive treatment demonstrated beneficial effects on both the ANS balance and the hemodynamic profile.

7.
Front Endocrinol (Lausanne) ; 12: 751743, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34659130

RESUMO

Background: Cushing's disease is a rare condition associated with a high cardiovascular risk and hypercortisolemia-related hemodynamic dysfunction, the extent of which can be assessed with a noninvasive method, called impedance cardiography. The standard methods for hemodynamic assessment, such as echocardiography or ambulatory blood pressure monitoring may be insufficient to fully evaluate patients with Cushing's disease; therefore, impedance cardiography is being currently considered a new modality for assessing early hemodynamic dysfunction in this patient population. The use of impedance cardiography for diagnosis and treatment of Cushing's disease may serve as personalized noninvasive hemodynamic status assessment and provide a better insight into the pathophysiology of Cushing's disease. The purpose of this study was to assess the hemodynamic profile of Cushing's disease patients and compare it with that in the control group. Material and Methods: This observational prospective clinical study aimed to compare 54 patients with Cushing's disease (mean age 41 years; with 64.8% of this population affected with arterial hypertension) and a matched 54-person control group (mean age 45 years; with 74.1% of this population affected with arterial hypertension). The hemodynamic parameters assessed with impedance cardiography included the stroke index (SI), cardiac index (CI), systemic vascular resistance index (SVRI), velocity index (VI), (ACI), Heather index (HI), and thoracic fluid content (TFC). Results: The Cushing's disease group was characterized by a higher diastolic blood pressure and a younger age than the control group (82.9 vs. 79.1 mmHg, p=0.045; and 41.1 vs. 44.9 years, p=0.035, respectively). Impedance cardiography parameters in the Cushing's disease group showed: lower values of SI (42.1 vs. 52.8 ml/m2; p ≤ 0.0001), CI (2.99 vs. 3.64 l/min/m2; p ≤ 0,0001), VI (42.9 vs. 52.1 1/1000/s; p=0.001), ACI (68.7 vs. 80.5 1/100/s2; p=0,037), HI (13.1 vs. 15.2 Ohm/s2; p=0.033), and TFC (25.5 vs. 27.7 1/kOhm; p=0.006) and a higher SVRI (2,515 vs. 1,893 dyn*s*cm-5*m2; p ≤ 0.0001) than those in the control group. Conclusions: Cushing's disease is associated with significantly greater vasoconstriction and left ventricular systolic dysfunction. An individual assessment with impedance cardiography may be useful in Cushing's disease patients in order to identify subclinical cardiovascular complications of chronic hypercortisolemia as potential therapeutic targets.


Assuntos
Cardiografia de Impedância/métodos , Hemodinâmica , Hipersecreção Hipofisária de ACTH/diagnóstico , Adulto , Envelhecimento , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipersecreção Hipofisária de ACTH/fisiopatologia , Estudos Prospectivos , Vasoconstrição , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Equilíbrio Hidroeletrolítico
8.
Front Endocrinol (Lausanne) ; 12: 793280, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35116005

RESUMO

Background: Arterial hypertension (AH) that accompanies acromegaly (AC) may lead to cardiovascular dysfunction. Such consequences may be detected with impedance cardiography (ICG), which is a noninvasive method of hemodynamic assessment. Early detection of subclinical hemodynamic alterations in AC patients may be crucial for optimizing treatment and preventing cardiovascular remodeling. The purpose of this study was to identify the hemodynamic parameters of the cardiovascular system that differentiate patients with AC from those in the control group (CG), with a particular emphasis on potential targets for medical therapy. Methods: This observational, prospective, clinical study involved a comparative analysis of 33 AC patients with no significant comorbidities and the controls selected via propensity score matching based on a set of baseline characteristics (age, sex, body mass index, mean blood pressure [MBP]), with comparable proportions of AH patients. The assessed hemodynamic parameters included the stroke volume index (SI), cardiac index, systemic vascular resistance index, velocity index (VI), acceleration index, Heather index (HI), and thoracic fluid content (TFC). Results: Both the AC group and the CG had well-controlled AH (mean blood pressure of 121/77 mmHg and 119/76 mmHg, respectively). In terms of baseline characteristics, the AC group was characterized by a higher hear rate and lower creatinine levels than the CG (76.2 bpm vs. 66.8 bpm [p = 0.001] and 0.755 mg/dL vs. 0.850 mg/dL [p = 0.035], respectively). ICG assessment of AC patients and CG patients showed the former to have higher heart rates (73.5 bpm vs. 65.2 bpm; p = 0.003), lower SI (43.8 mL/m2 vs. 53.4 mL/m2; p = 0.0001), lower VI (42.1 1/1000/s vs. 49.3 1/1000/s; p = 0.037), lower HI (8.49 Ohm/s2 vs. 13.4 Ohm/s2, p ≤ 0.0001), and higher thoracic fluid content (TFC) (38.4 1/kOhm vs. 28.1 1/kOhm; p ≤ 0.0001), respectively. Conclusions: Even with well-controlled hypertension, AC is associated with a high TFC, increased heart rate, and decreased indices of cardiac contractility. Hemodynamic changes in AC patients may be detected with the modern, noninvasive diagnostic tool, ICG.


Assuntos
Acromegalia/fisiopatologia , Cardiografia de Impedância , Hemodinâmica/fisiologia , Hipertensão/fisiopatologia , Adulto , Velocidade do Fluxo Sanguíneo , Débito Cardíaco , Estudos de Casos e Controles , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Remodelação Vascular , Resistência Vascular , Rigidez Vascular , Remodelação Ventricular
9.
Cardiovasc Ther ; 2020: 8563135, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123219

RESUMO

Metabolic syndrome (MetS) is a combination of factors which, collectively, increase cardiovascular risk to a greater extent than each of them separately. Previous studies showed high cardiovascular risk to be associated with autonomic nervous system dysfunction. The purpose of this study was to assess the effects of antihypertensive treatment on heart rate variability (HRV) in patients with hypertension (HTN), depending on cooccurrence of MetS. 118 patients with uncontrolled HTN were enrolled to the study. HRV was compared among patients with and without MetS (MetS [+], n = 70) at baseline and following 12 months antihypertensive treatment. The HRV indices measured from RR intervals recorded form using 24-hour ambulatory electrocardiography. The measured HRV domains were the standard deviation of the average of NN intervals [SDNN], square root of the mean of the sum of the squares of differences between adjacent NN intervals [rMSSD], percentage of NN50 [pNN50], low frequency [LF], high frequency [HF], total power of variance of all NN intervals [TP], and LF/HF ratio. Baseline parameters: SDNN, rMSSD, pNN50, and HF were significantly lower in the MetS[+] compared to the MetS[-] subgroup (p < 0.05). After a 12-month antihypertensive treatment, MetS[+] patients achieved a significant improvement in parameters: SDNN, rMSSD, pNN50, and TP (p < 0.05), while the changes in HRV observed in the MetS[-] subgroup were not statistically significant. The cooccurrence of HTN and other components of MetS is associated with disturbances of the autonomic balance. HTN control has a beneficial effect on HRV, with the effect being more evident in patients with MetS.


Assuntos
Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Hipertensão/tratamento farmacológico , Síndrome Metabólica/tratamento farmacológico , Adulto , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Síndrome Metabólica/diagnóstico , Síndrome Metabólica/fisiopatologia , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
10.
Kardiol Pol ; 78(10): 1015-1019, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32692030

RESUMO

BACKGROUND: Data on the results of ablation for atrial fibrillation (AF) in Poland are scarce. AIMS: The aim of the study was to compare the efficacy of ablation index (AI)-guided pulmonary vein isolation (PVI) with that of conventional contact force-based PVI. METHODS: Consecutive patients undergoing PVI for the first time were included in the study. A nonrandomized retrospective comparison was made between patients ablated with contact force before AI was introduced (non -AI group) and patients ablated with the use of AI (AI group). The AI threshold for the anterior wall / roof of left veins was 500 and 380 elsewhere. The maximal interlesion distance was 6 mm. The follow -up included outpatient visits and 7-day Holter monitoring 6 and 12 months after ablation. RESULTS: A total of 275 patients were included in the analysis: 133 in the AI group and 142 in the non--AI group. The duration of AF ablation was slightly longer in the AI group, but the fluoroscopy time and the radiofrequency ablation time were shorter in the same group. During the 12-month follow -up period, 25.8% and 40.6% of patients from the AI and non -AI groups, respectively, experienced recurrences (P = 0.02). The log -rank test with an extended follow -up period of up to 18 months confirmed the difference between the AI and non -AI groups, both in the whole group and in the paroxysmal AF and nonparoxysmal AF subgroups (P = 0.001, P = 0.04, and P = 0.006, respectively). CONCLUSION: The AI -based protocol provides a significant advantage over traditional contact force-based radiofrequency ablation in nonselected patients undergoing PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Humanos , Polônia , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
11.
Sci Rep ; 10(1): 4424, 2020 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-32157193

RESUMO

MicroRNAs mediate posttranscriptional gene regulation. The aim of the study was to find a microRNA predictor of successful atrial fibrillation (AF) ablation. A total of 109 patients undergoing first-time AF ablation were included. Nineteen patients were selected to undergo serum microRNA sequencing (study group). The sequencing data were used to select several microRNAs that correlated with 12-month recurrences after AF ablation. Those microRNAs were validated by digital droplet PCR in samples from remaining 90 patients. All patients underwent pulmonary vein isolation (RF ablation, contact force catheter, electroanatomical system). The endpoint of the study was the 12-month AF recurrence rate; the overall recurrence rate was 42.5%. In total, levels of 34 miRNAs were significantly different in sera from patients with AF recurrence compared to patients without AF recurrence. Six microRNAs (miR-183-5p, miR-182-5p, miR-32-5p, miR-107, miR-574-3p, and miR-144-3p) were validated in the whole group. Data from the validation group did not confirm the observations from the study group, as no significant differences were found between miRNAs serum levels in patients with and without recurrences 12 months after AF ablation.


Assuntos
Fibrilação Atrial/genética , Biomarcadores/sangue , Ablação por Cateter/métodos , MicroRNAs/genética , Fibrilação Atrial/sangue , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , MicroRNAs/sangue , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
12.
Invest Ophthalmol Vis Sci ; 57(6): 2533-42, 2016 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-27159443

RESUMO

PURPOSE: We investigated whether 24-hour monitoring of corneoscleral limbus area (CSLA) with the Sensimed Triggerfish contact lens sensor (CLS) can be used clinically to assess midterm efficacy of canaloplasty and to assess the relationships of CSLA changes with the heart rhythm. METHODS: Ten eyes of 10 patients, with POAG, which were qualified either to canaloplasty or canaloplasty and phacoemulsification, were included in this study. Eyes were washed out before the surgery and control visits were done at days 1, 7, and 3, 6, 12 months postoperatively, at which subjects were examined. We performed 24-hour monitoring of CSLA changes and Holter ECG at washout, and at 3- and 12-month postop visits. Raw CLS signals were processed to lead two parameters describing short-term 24-hour variability of CSLA (VAR, â). Heart activity parameters from CLS were compared to those acquired from Holter ECG. RESULTS: Mean post washout IOP was 20.6 ± 4.7 and decreased to 14.2 ± 3.0 mm Hg 1 year after surgery (P < 0.01). A decreasing trend in VAR and â parameters were noted. Statistically significant differences were found between the washout and 3-month postop visit for VAR and â (P = 0.014 and P = 0.027, respectively) as well as between the washout and 12-month postop result for the parameter â (P = 0.031). No statistically significant differences were found between the 3- and 12-month postop results for both considered parameters. CONCLUSIONS: Canaloplasty alone or combined with cataract surgery is a successful surgical method of lowering IOP in glaucoma patients. Canaloplasty decreases 24-hour CSLA fluctuation pattern measured with CLS.


Assuntos
Ritmo Circadiano , Cirurgia Filtrante/métodos , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Limbo da Córnea/anatomia & histologia , Monitorização Fisiológica/métodos , Acuidade Visual , Idoso , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Masculino , Tamanho do Órgão , Período Pós-Operatório , Estudos Prospectivos , Fatores de Tempo
13.
Cardiol J ; 22(1): 75-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24846513

RESUMO

BACKGROUND: Several clinical and experimental studies have shown that unnecessary right ventricular pacing in sinus node disease can be detrimental. Inter- and intra-ventricular asynchrony imposed by right ventricular pacing may cause reduction in contractility and relaxation of left ventricle, worsening mitral regurgitation, regional redistribution of myocardial perfusion and oxygen consumption, and asymmetrical hypertrophy of left ventricular wall. In some patients, sinus node disease coexists with impaired atrioventricular conduction. The optimal pacing mode in this population is not determined. Minimizing right ventricular pacing can preserve inter- and intra-ventricular synchrony. On the other hand, longer atrioventricular delay may cause atrioventricular asynchrony. The aim of this study was to prospectively assess the impact of minimizing right ventricular pacing in patients with DDD pacemaker implanted for sinus node disease and prolonged PQ interval on exercise capacity, cardiac function and quality of life. METHODS: The study enrolled 50 consecutive patients with prolonged PQ interval who were implanted with DDD pacemaker because of sinus node disease. Each patient was treated alternately with 2 pacing modes in random order for 4-month periods: conventional dualchamber pacing and dual-chamber minimal ventricular pacing (prolonged atrioventricular delay). At the end of each phase the following tests were performed: cardiopulmonary exercise testing, echocardiographic evaluation and quality of life assessment (SF36). RESULTS: There was no significant relationship between pacing mode and cardiopulmonary parameters, echocardiographic parameters and quality of life. CONCLUSIONS: Sequential atrioventricular pacing may be a reasonable choice for treating patients with sinus node disease and prolonged PQ interval.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Tolerância ao Exercício , Sistema de Condução Cardíaco/fisiopatologia , Síndrome do Nó Sinusal/terapia , Função Ventricular Direita , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Estudos Cross-Over , Ecocardiografia , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Marca-Passo Artificial , Polônia , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/fisiopatologia , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
14.
Med Sci Monit ; 20: 2607-16, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25502623

RESUMO

BACKGROUND: It is believed that endothelial dysfunction may be a link between systemic and ocular dysregulation in glaucoma. The aim of this study was to evaluate peripheral vascular reactive hyperemia in response to occlusion test and to correlate peripheral vascular findings with retrobulbar hemodynamics parameters in patients with normal-tension glaucoma. MATERIAL AND METHODS: Forty-eight patients with normal-tension glaucoma (mean age 58.1 years, 38 women) and 40 control subjects (mean age 54.1 years, 36 women) were subjected to a brachial arterial occlusion test and color Doppler imaging (LOGIQ 9, GE Medical Systems) of the retrobulbar arteries. Finger hyperemia was assessed by using a 2-channel laser Doppler flowmeter (MBF-3D, Moor Instruments, Ltd.). Time parameters (time to peak flow, half-time of hyperemia, time of recovery) and amplitude parameters (maximum hyperemia response, biological zero) of the post-occlusive reactive hyperemia signal pattern as well as velocities and resistance index of the ophthalmic, central retinal, and short posterior ciliary arteries were evaluated and compared between study groups. RESULTS: In glaucoma patients, time to peak flow and half-time of hyperemia were significantly longer (21.4 vs. 12.0 s, p=0.02 and 74.1 vs. 44.2 s, p=0.03, respectively) and biological zero was significantly lower (2.4 vs. 3.2, p=0.01) comparing with healthy subjects. In glaucoma patients, peak-systolic and end-diastolic velocities of central retinal artery were significantly lower (12.8 vs.14.1, p=0.03 and 3.9 vs. 4.7, p=0.01, respectively) and resistance index of this artery was significantly higher (0.69 vs. 0.67, p=0.03) compared to controls. In the glaucoma group, maximum hyperemic response was negatively correlated with the resistance index of temporal short posterior ciliary arteries (r=-0.4, p=0.01), whereas in the control group half-time of hyperemia was negatively correlated with end-diastolic velocity of the central retinal artery (r=-0.3, p=0.03). CONCLUSIONS: Arterial occlusion test elicited a prolonged systemic hyperemia response in patients with glaucoma as compared with healthy subjects. Retrobulbar blood flow alterations in glaucoma patients may be related to systemic vascular dysregulation.


Assuntos
Glaucoma/complicações , Hiperemia/etiologia , Feminino , Glaucoma/diagnóstico por imagem , Glaucoma/fisiopatologia , Hemodinâmica , Humanos , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ultrassonografia Doppler em Cores
15.
Kardiol Pol ; 72(2): 134-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23990235

RESUMO

BACKGROUND: Short periods of cerebral ischaemia during ventricular defibrillation testing may be associated with neuropsychological impairment. However, the impact of out-of-hospital ventricular fibrillation (VF) converted by implantable cardioverter-defibrillator (ICD) shock on cognitive functioning is unknown. AIM: To assess the impact of out-of-hospital VF converted by ICD shock on cognitive functioning. METHODS: The study included 52 primary prevention ICD recipients. Patients with a history of stroke or other neurological impairment, previous head injury and individuals unable to see or speak to complete neuropsychological tests were not included.Initially, a Mini-Mental State Examination was performed in all patients and one patient with a result below 24 points was excluded from the study. The cognitive battery consisted of four tests (six measurements): 1) the Digit Span subtest of Wechsler Adult Intelligence Scale-Revised; 2) the Digit Symbol subtest of Wechsler Adult Intelligence Scale-Revised; 3) the Halstead-Reitan Trail-Making Test A and B; and 4) the Ruff Figural Fluency Test. RESULTS: The mean time from ICD implantation to cognitive assessment was 26 months. During this period, 15 appropriate shocks for VF were observed in seven (14%) patients. The patients with appropriate ICD therapy were significantly worse in two out of the six neuropsychological measurements and had a significantly lower aggregate result. In multivariate linear regression analysis, defibrillation therapy was an independent factor of poor cognitive functioning, along with age and education. CONCLUSIONS: Short periods of out-of-hospital VF converted by ICD are associated with cognitive impairment in the recipients of primary prevention ICD.


Assuntos
Isquemia Encefálica/etiologia , Transtornos Cognitivos/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Fatores de Risco
16.
Br J Ophthalmol ; 96(5): 624-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22399689

RESUMO

AIMS: To define parameters of autonomic nervous system activity in patients with normal tension glaucoma (NTG). METHODS: Ambulatory 24-h ECG (Lifecard CF) and 24-h blood pressure (BP) monitoring (SpaceLab 90207-30) were carried out in 54 patients with NTG (44 women, mean age 59.7) and 43 matched control subjects (34 women, mean age 57.0). Heart rate variability time and frequency domain parameters (low frequency (LF), high frequency (HF) and LF/HF ratio), BP variability (BPV), diurnal and nocturnal BP variables were compared between study groups. RESULTS: Patients with NTG demonstrated higher LF, LF/HF and lower HF values than control subjects for the 24-h, daytime and night-time periods. The mean 24-h, daytime and night-time LF/HF ratios were statistically higher in patients with glaucoma as compared to control subjects ((3.2±1.5 vs 2.2±0.8, p=0.0009), (3.5±1.7 vs 2.7±1.0, p=0.0173) and (2.6±1.7 vs 1.4±0.6, p=0.0001), respectively). There were no statistical differences in the mean BP during the whole day, daytime and night-time, and in BPV (10.4±1.9 vs 10.5±2.1, p=0.790) between study groups. No difference was also found in the percentage decrease in night-time mean BP (12.3% vs 13.6%, p=0.720). 'Dippers', 'non-dippers' and 'overdippers' with NTG showed significantly higher LF/HF ratio as compared to the same subgroups of control subjects. CONCLUSIONS: The sympathovagal balance of autonomic nervous system in patients with NTG shifted towards sympathetic activity however with no change of 24-h pattern of BPV as compared to controls.


Assuntos
Doenças do Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Glaucoma de Baixa Tensão/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial , Ecocardiografia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Testes de Campo Visual , Campos Visuais/fisiologia
17.
Kardiol Pol ; 69(12): 1266-71, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22219104

RESUMO

BACKGROUND: Exercise oscillatory ventilation (EOV) is a common pattern of breathing in heart failure (HF) patients, and indicates a poor prognosis. AIM: To investigate the effects of adaptive servoventilation (ASV) on ventilatory response during exercise. METHODS: We studied 39 HF patients with left ventricular ejection fraction (LVEF) £ 45. Cardiorespiratory polygraphy, cardiopulmonary exercise testing (CPET), echocardiography, and measurement of N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration were performed. Twenty patients with Cheyne-Stokes respiration and apnoea-hypopnoea index (AHI) ≥ 15/h were identified. Of these, 11 patients were successfully titrated on ASV and continued therapy. In the third month of ASV treatment, polygraphy, CPET, echocardiography, and measurement of NT-proBNP concentration were performed again. RESULTS: The EOV was detected at baseline in 12 (31%) HF patients, including eight (67%) who underwent ASV. The EOV was associated with significantly lower LVEF, peak oxygen uptake (VO(2)), and ventilatory anaerobic threshold (VAT), and a significantly higher left ventricular diastolic diameter (LVDD), slope of ventilatory equivalent for carbon dioxide (VE/VCO(2)), AHI, central AHI and NT-proBNP concentration. In seven patients with EOV, reversal of EOV in the third month of ASV therapy was observed; only in one patient did EOV persist (p = 0.0156). CONCLUSIONS: The EOV can be reversed with ASV therapy. The EOV in association with central sleep apnoea and Cheyne- -Stokes respiration (CSA/CSR) is prevalent in HF patients and correlates with severity of the disease.


Assuntos
Exercícios Respiratórios , Respiração de Cheyne-Stokes/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/reabilitação , Adaptação Fisiológica , Idoso , Doença Crônica , Exercício Físico/fisiologia , Teste de Esforço , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/metabolismo , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/fisiopatologia , Ultrassonografia
18.
Cardiol J ; 17(1): 88-91, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20104463

RESUMO

Cytotoxicity of drugs can be a cause of cardiorespiratory disorders connected with chemotherapy. Doxorubicin is an antibiotic from the group of anthracyclines effective in antineoplastic therapy of solid and hematopoetic tumors. The most common cause of therapy ceasing is its cardiotoxicity. However, a lung injury connected with its cytotoxic activity to pulmonary endothelium (capillary leak syndrome) can be an equally serious complication. In the case presented, rapid, multi-profile diagnostics with the use of impedance cardiography, a modern noninvasive tool of hemodynamic monitoring, led to the recognition and effective treatment of a rare clinical syndrome.


Assuntos
Antibióticos Antineoplásicos/efeitos adversos , Síndrome de Vazamento Capilar/induzido quimicamente , Síndrome de Vazamento Capilar/diagnóstico , Cardiografia de Impedância , Doxorrubicina/efeitos adversos , Pulmão/irrigação sanguínea , Mieloma Múltiplo/tratamento farmacológico , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Ciclofosfamida/uso terapêutico , Humanos , Masculino , Melfalan/uso terapêutico , Prednisona/uso terapêutico , Retratamento , Resultado do Tratamento , Vincristina/uso terapêutico
20.
Klin Oczna ; 111(1-3): 75-9, 2009.
Artigo em Polonês | MEDLINE | ID: mdl-19517852

RESUMO

Primary open angle glaucoma is linked to autonomic nervous system dysfunction. In a review the role of autonomic nervous system as an important determinant of systemic hemodynamic parameters such as heart rate and blood pressure, was presented. Human circadian clock and its impact on autonomic nervous system was emphasized. Finally some autonomic function tests and therapeutical implications were described.


Assuntos
Doenças do Sistema Nervoso Autônomo/complicações , Glaucoma de Ângulo Aberto/etiologia , Doenças do Sistema Nervoso Autônomo/terapia , Ritmo Circadiano , Glaucoma de Ângulo Aberto/terapia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...