Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Health Serv Res ; 21(1): 325, 2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33836726

RESUMO

BACKGROUND: Transfer into the operating room, onto the operating table and mask induction of anaesthesia are major challenges faced by children with Autistic Spectrum Disorder (ASD). In a pilot study, parents observed that perioperative transfer becomes unsafe and difficult when children with ASD becomes uncooperative. METHOD: A CHILD-KIND CONCEPT mobility system comprising of multi-positioning seat configurations and restraining module was developed with inputs from multi-disciplinary healthcare professionals and parents with children with ASD. To appeal to children and motivate child-machine interaction, the seat configurations and restraining module are designed to take the form of child-friendly, non-threatening, fun and familiar items. The sitting configuration, sitting to supine transformation, the restraint modules resemble racing-car seat, reclining motion of a home massage chair, safety restraints found in airplanes and amusement rides respectively. Healthcare professionals (HCPs) involved in the perioperative patient care, parents of ASD children and children (neurotypical and ASD) experience the use of the system in a non-clinical environment and participated in a survey study. The acceptance of its functionality (HCPs, parents) for perioperative transfer and induction of anaesthesia, rating of the user experience and likes and dislikes of (parents and children) were obtained. RESULTS: Thirty-two HCPs, 30 parents and 23 children participated. Majority of parents and HCPs opined the use of the system enables improvement in the management of perioperative movement (90.0% parents, 100% HCPs), safe perioperative movement (86.7% parents, 96.9% HCPs) and promotes ease of anaesthesia induction (76.7% parents, 90.6% HCPs) for uncooperative combative ASD children. Overall, 93.8% HCPs and 86.7% parents would recommend its frequent use in their own practice and their ASD children respectively. Attractiveness and multi-functionality are attributes endorsed by parents and children. Children endorse its use for induction of anaesthesia (73.9%), dental chair (82.6%), intra-hospital transfer (95.7%). CONCLUSION: A child-kind mobility device that integrates appeal with functionality of restraint and multi-positional transformation has a potential to promote safe perioperative movement and ease of induction of anaesthesia in anxious uncooperative ASD children.


Assuntos
Transtorno do Espectro Autista , Anestesia Geral , Criança , Estudos Transversais , Humanos , Pais , Projetos Piloto
2.
PLoS One ; 15(2): e0227805, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32045936

RESUMO

A force sensor system was developed to give real-time visual feedback on a range of force. In a prospective observational cross-section study, twenty-two anaesthesia nurses applied cricoid pressure at a target range of 30-40 Newtons for 60 seconds in three sequential steps on manikin: Group A (step 1 blinded, no sensor), Group B (step 2 blinded sensor), Group C (step 3 sensor feedback). A weighing scale was placed below the manikin. This procedure was repeated once again at least 1 week apart. The feedback system used 3 different colours to indicate the force range achieved as below target, achieve target, above target. Significantly higher proportion of target cricoid pressure was achieved with the use of sensor feedback in Group C; 85.9% (95%CI: 82.7%-88.7%) compared to when blinded from sensor in Group B; 31.3% (95%CI: 27.4-35.4%). Cricoid force achieved blind (Group B) exceeded force achieved with feedback (Group C) by a mean of 8.0 (95%CI: 5.9-10.2, p<0.0001) and 6.2 (95%CI:4.1-8.3, p< 0.0001) Newtons in round 1 and 2 respectively. Weighing scale read lower than corresponding force sensor by a mean of 8.4 Newtons (95% CI: 7.1-9.7, p<0.0001) in group B and 5.8 Newtons (95% CI: 4.5-7.1, p<0.0001) in Group C. Force sensor visual feedback system enabled application of reproducible target cricoid pressure with less variability and has potential value in clinical use. Using weighing scale to quantify and train cricoid pressure requires a review. Understanding the force applied is the first step to make cricoid pressure a safe procedure.


Assuntos
Anestesiologia , Sistemas Computacionais , Manequins , Adulto , Fenômenos Biomecânicos , Cartilagem Cricoide/fisiologia , Estudos Transversais , Retroalimentação , Feminino , Humanos , Estudos Prospectivos
3.
Front Pediatr ; 6: 97, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29707528

RESUMO

BACKGROUND: Since oxygen saturation from pulse oximetry (SpO2) and partial pressure of arterial oxygen (PaO2) are observed to improve immediately after surgical correction of cyanotic congenital heart disease (CHD), we postulate that cerebral (CrO2) and somatic (SrO2) oximetry also improves immediately post-correction. We aim to prospectively examine CrO2 and SrO2, before, during, and after surgical correction as well as on hospital discharge in children with cyanotic CHD to determine if and when these variables increase. METHODS: This is a prospective observational trial. Eligibility criteria included children below 18 years of age with cyanotic CHD who required any cardiac surgical procedure. CrO2 and SrO2 measurements were summarized at six time-points for comparison: (1) pre-cardiopulmonary bypass (CPB); (2) during CPB; (3) post-CPB; (4) Day 1 in the pediatric intensive care unit (PICU); (5) Day 2 PICU; and (6) discharge. Categorical and continuous variables are presented as counts (percentages) and median (interquartile range), respectively. RESULTS: Twenty-one patients were analyzed. 15 (71.4%) and 6 (28.6%) patients underwent corrective and palliative surgeries, respectively. In the corrective surgery group, SpO2 increased immediately post-CPB compared to pre-CPB [99 (98, 100) vs. 86% (79, 90); p < 0.001] and remained in the normal range through to hospital discharge. Post-CPB CrO2 did not change from pre-CPB [72.8 (58.8, 79.0) vs. 72.1% (63.0, 78.3); p = 0.761] and even decreased on hospital discharge [60.5 (53.6, 62.9) vs. 72.1% (63.0, 78.3); p = 0.005]. Post-CPB SrO2 increased compared to pre-CPB [87.3 (77.2, 89.5) vs. 72.7% (65.6, 77.3); p = 0.001] but progressively decreased during PICU stay to a value lower than baseline at hospital discharge [66.9 (57.3, 76.9) vs. 72.7% (65.6, 77.3); p = 0.048]. CONCLUSION: CrO2 and SrO2 did not increase after corrective surgery of cyanotic CHD even up to hospital discharge. Future larger studies are required to validate these findings. (This study is registered with ClinicalTrials.gov ID: NCT02417259.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...