Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Interv Card Electrophysiol ; 65(2): 471-480, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35604577

RESUMO

PURPOSE: The second-generation multi-electrode catheter, PVAC Gold, was designed to improve the safe delivery of phased radiofrequency energy using a "single shot" approach for pulmonary vein isolation (PVI), while retaining efficacy. This large registry presents long-term performance in a daily practice setting. METHODS: A total of 1011 patients undergoing first time ablation for atrial fibrillation (AF) using PVAC Gold were included, 639 patients with PVI for paroxysmal AF (PAF PVI) and 372 patients with persistent or long-standing persistent AF, divided into 175 patients receiving PVI only (PersAF PVI) and 197 patients receiving PVI with additional substrate ablation (PersAF PVI +). RESULTS: At 24-month follow-up, single procedure freedom from atrial tachyarrhythmia (ATA) was 58% (368/639) in the PAF PVI group, 44% (77/175) in the PersAF PVI group, and 29% (57/197) in the PersAF PVI + group. Allowing one repeat procedure in 33% of patients, 76%, 65%, and 54% were free from ATA at 24 months, respectively. Pulmonary vein reconnection was observed in 98% of patients with recurrent arrhythmia after PVI. CONCLUSIONS: Although phased RF ablation with PVAC Gold is quick and safe, the efficacy outcomes are modest compared to current mainstream ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Ouro , Seguimentos , Resultado do Tratamento , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Catéteres , Recidiva
2.
Neth Heart J ; 30(5): 273-281, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34699026

RESUMO

INTRODUCTION: The AcQMap High Resolution Imaging and Mapping System was recently introduced. This system provides 3D maps of electrical activation across an ultrasound-acquired atrial surface. METHODS: We evaluated the feasibility and the acute and short-term efficacy and safety of this novel system for ablation of persistent atrial fibrillation (AF) and atypical atrial flutter. RESULTS: A total of 21 consecutive patients (age (mean ± standard deviation) 62 ± 8 years, 23% female) underwent catheter ablation with the use of the AcQMap System. Fourteen patients (67%) were treated for persistent AF and 7 patients (33%) for atypical atrial flutter. Eighteen patients (86%) had undergone at least one prior ablation procedure. Acute success, defined as sinus rhythm without the ability to provoke the clinical arrhythmia, was achieved in 17 patients (81%). At 12 months, 4 patients treated for persistent AF (29%) and 4 patients treated for atypical flutter (57%) remained in sinus rhythm. Complications included hemiparesis, for which intra-arterial thrombolysis was given with subsequent good clinical outcome (n = 1), and complete atrioventricular block, for which a permanent pacemaker was implanted (n = 2). No major complications attributable to the mapping system occurred. CONCLUSION: The AcQMap System is able to provide fast, high-resolution activation maps of persistent AF and atypical atrial flutter. Despite a high acute success rate, the recurrence rate of persistent AF was relatively high. This may be due to the selection of the patients with therapy-resistant arrhythmias and limited experience in the optimal use of this mapping system that is still under development.

3.
J Interv Card Electrophysiol ; 62(3): 587-599, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33454910

RESUMO

PURPOSE: Ablation of atypical atrial flutter (AAFL) can be challenging. High-density (HD) mapping of ablation targets may potentially increase procedural success and freedom from recurrent AAFL. The objective of the present study was to explore whether employing HD mapping leads to a more favorable outcome in ablation of AAFL. METHODS: We compared baseline and procedural characteristics, procedural success, safety and outcome of mapping and ablation of atypical flutter in three groups. (1) HD Grid catheter + the high-density electroanatomical mapping (EAM) system EnSite Precision; (2) standard 10-pole circular mapping catheter (CMC) + EnSite Precision; (3) CMC + the low-density EnSite Velocity EAM. Voltage and propagation maps were constructed. RESULTS: Mapping of 142 AAFL in 82 patients was performed. Acute ablation success was 78%, 68%, and 51% in groups 1, 2, and 3 (p = 0.037 between group 1 and 3, non-significant between groups otherwise). Moreover, 8%, 27%, and 36% of flutters were unmappable in groups 1, 2, and 3, respectively (p < 0.05 between group 1 and both groups 2 and 3). AAFL recurrence at 1-year FU was 26%, 36%, and 62% in groups 1, 2, and 3 (p = 0.007 between groups 1 and 3, p = 0.05 between groups 2 and 3). AAFL-free survival was significantly higher in patients mapped with Precision than with Velocity (p = 0.011). No strokes or mortality occurred within 30 days. CONCLUSIONS: Acute procedural success of ablation of atypical atrial flutter is higher and the number of unmappable flutters is lower using the HD Grid mapping catheter in combination with the high-density EnSite Precision system, as compared to a decapolar circular mapping catheter and the low-density EnSite Velocity EAM system. This may lead to increased freedom from recurrent AAFL at 1 year. HD mapping is safe.


Assuntos
Flutter Atrial , Ablação por Cateter , Arritmias Cardíacas , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Humanos , Fatores de Tempo , Resultado do Tratamento
4.
J Interv Card Electrophysiol ; 60(2): 261-270, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32253598

RESUMO

PURPOSE: The second-generation multi-electrode catheter, pulmonary vein ablation catheter (PVAC) GOLD, was designed to improve the delivery of phased radiofrequency energy and reduce procedure times using a 'single-shot' approach for pulmonary vein isolation (PVI), while retaining efficacy and safety. This large registry presents acute success rates and safety outcomes in a daily practice setting. METHODS: A total of 1017 patients undergoing first-time ablation for atrial fibrillation (AF) using PVAC GOLD were included, 644 patients with paroxysmal AF and 373 patients with non-paroxysmal AF, divided into 175 patients receiving PVI only and 198 patients receiving PVI with additional substrate modification. RESULTS: High and comparable percentages of successful PVI could be achieved in all groups (98%, 95% and 99%; p = 0.108). The median total procedure time for all groups was 90 min [70-100]. As expected, the total procedure, ablation and fluoroscopy time were significantly longer in the PVI + substrate modification group compared with the PVI-only cases (all p < 0.001), but not between the PVI-only groups (p = 0.306, p = 0.088, p = 0.233, respectively). A total of 44 complications were observed in 43 patients (4.2%). Major complications were seen in 19 patients (1.87%) and non-major procedure-related complications were seen in 25 patients (2.46%). Complications leaving permanent sequelae were rare and occurred in only four patients (0.39%). Complications did not differ between groups (p = 0.199, p = 0.438, p = 0.240 and p = 0.465 respectively). CONCLUSION: PVAC GOLD performs successful PVI, while reducing procedure times and retaining safety for paroxysmal, persistent and long-standing persistent AF. Safety was unaffected by additional substrate modification.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
Neth Heart J ; 27(12): 605-612, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31773474

RESUMO

BACKGROUND: Current guidelines recommend non-vitamin­K oral anticoagulants (NOACs) as the first-choice therapy for stroke prevention in patients with atrial fibrillation (AF). The use of drugs in a clinical trial setting differs from that in real-world populations. Real-world data are important to accrue more heterogeneous patient populations with respect to co-morbidities and co-medication use. The aim of this study was to evaluate the use of NOACs in daily practice in a large tertiary hospital in the Netherlands. METHODS: A single-centre prospective study was conducted among all patients with AF using a NOAC in the St. Antonius Hospital between 2013 and June 2017. The outcomes were the rates of any bleeding, stroke/transient ischaemic attack, mortality, discontinuation rate and adverse drug reactions. RESULTS: In total, 799 patients were enrolled with a mean follow-up of 1.7 years. Mean age was 69.8 (SD ± 11) and 61.2% were male. Mean CHA2DS2-VASc score was 2.8 (SD ± 1.6) and mean HAS-BLED score was 1.4 (SD ± 0.9). Bleeding occurred in 6.0, major bleeding in 1.8, stroke in 1.2 patients per 100 patient-years, and 87 patients (10.9%) died during the follow-up period. Adverse drug reactions were reported by 59 patients (7.4%). Finally, 249 patients (31.2%) reported a temporary interruption and 132 (16.5%) permanent discontinuation of NOAC treatment, of whom 33 (25%) patients switched to a vitamin­K antagonist. CONCLUSIONS: We observed low rates of bleeding and adverse drug reactions. However, rates of mortality and discontinuation were relatively high. These results could possibly be explained by the real-world nature of the data including higher-risk patients.

7.
J Interv Card Electrophysiol ; 37(2): 197-204, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23636869

RESUMO

INTRODUCTION: The pulmonary vein ablation catheter (PVAC) is designed for pulmonary vein isolation (PVI). Electrical reconnection of pulmonary veins is believed to result in AF recurrence. The purpose of this study was to establish the location and extent of PV reconnection after PVI with the PVAC catheter. METHODS AND RESULTS: Eighty-two patients (79 % male, age 60 ± 9 years) that underwent a redo procedure for recurrent AF after PVAC ablation were assessed for prevalence and location of reconnection. The number of reconnected PV's was 0, 1, 2, 3, or 4 in 2 (2.4 %), 14 (17 %), 23 (28 %), 28 (34 %), and 15 (18 %) patients, respectively. Reconnection of left superior, left inferior, left common, right superior, and right inferior PV's was found in 66, 63, 83, 57, and 67 %, respectively (p = 0.48). In the left PV's, reconnection was located significantly more anterior than posterior; LSPV anterior 32/70 vs posterior 13/70 (p < 0.01), LIPV anterior 26/70 vs posterior 9/70 (p < 0.01). In the right PV's reconnection was distributed equally in all quadrants. Different modes of RF delivery during PVAC ablation (bipolar/unipolar 2:1 [n = 35] vs. 4:1 [n = 47]) yielded comparable rates of PV reconnection. During follow-up (median 296 days) no AF/AT was documented in 57 patients (70 %). CONCLUSION: Almost all patients (98 %) with AF after PVAC ablation show reconnection of at least one PV. All PV's are equally likely to show reconnection. In the left PV's, reconnection was found more often anteriorly than posteriorly. During pulmonary vein isolation with the PVAC catheter, prevalent sites of reconnection deserve close attention to increase success.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Eletrodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Reoperação/instrumentação , Reoperação/métodos
8.
Europace ; 9(4): 203-7, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17350984

RESUMO

AIMS: In this study, we evaluated the effects of atrial shock delivered via diagnostic electrophysiology catheters. METHODS AND RESULTS: In 11 anaesthetized goats, decapolar catheters were positioned in the right atrial appendage (RAA) and coronary sinus (CS). Three different catheters and two cardioversion protocols were evaluated. In four goats, 50 J shocks were delivered using catheters with 1 mm electrodes (surface area 70 mm(2)). In 6 goats, catheters with 2 mm electrodes (area 140 mm(2)) were used. In three of the six goats, 50 J shocks were given while in the other 3, 10 J shocks were delivered. In 1 goat 50 J shocks were delivered via 5 mm electrode catheters (area 310 mm(2)). No persisting adverse effects occurred. However, the electrogram amplitude at the RAA and CS decreased by >50-98% (P > 0.01). The amount of amplitude decrease was most pronounced at the CS site and for 50 J shocks. Goats were sacrificed after 9 +/- 1 days. Macroscopy revealed endocardial lesions at the electrode locations. Microscopy showed endocardial thrombosis, and necrosis with formation of granulation tissue. Changes were most marked with diagnostic catheters and 50 J shocks. CONCLUSIONS: Atrial shock delivery via diagnostic catheters causes local ablation lesions. The amount of amplitude decrease, macroscopic and microscopic damages were related to the energy applied and electrode surface area.


Assuntos
Artefatos , Função Atrial/efeitos da radiação , Cateterismo Cardíaco/métodos , Cardioversão Elétrica/métodos , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiologia , Animais , Feminino , Cabras , Átrios do Coração/anatomia & histologia , Sistema de Condução Cardíaco/anatomia & histologia , Sistema de Condução Cardíaco/efeitos da radiação
9.
Circ Res ; 96(7): 776-83, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15761198

RESUMO

Atriofascicular accessory bundles with AV-node like conduction properties can sustain atrioventricular (AV) re-entrant tachycardia (Mahaim tachycardia). During early embryogenesis, the AV canal is situated above the primitive left ventricle (LV), and a right AV connection has not been achieved yet. We studied the formation of the right ventricular (RV) inflow tract in relation to the developing cardiac conduction system and hypothesized a morphological explanation for functional atriofascicular bypass tracts. Analysis of lacZ-expression during sequential stages of cardiogenesis was performed in CCS-lacZ transgenic mice (E9.5 to 15.5). Embryos were stained for beta-galactosidase activity and the myocardial marker HHF35. At early stages CCS-lacZ expression was observed in a ring surrounding the AV canal, which connected at the inner curvature to the primary fold. The first sign of formation of the (CCS-lacZ negative) RV inlet component was a groove in the CCS-lacZ positive tissue of the primary fold. Outgrowth of the RV inlet tract resulted in division of the primary fold in a septal part, the trabecula septomarginalis and a lateral part, the moderator band, which extended laterally up to the right AV ring. Electrophysiological measurements in embryonic hearts (E15.5) in which the right atrium (RA) and RV were isolated from the left atrium (LA) and LV supported the functionality of this AV-connection via the moderator band, by demonstrating sequential atrial and ventricular activation in both RA/RV and LA/LV preparations. In conclusion, our observations may provide a possible morphological and functional explanation for atriofascicular accessory pathways via the moderator band, underlying Mahaim tachycardia.


Assuntos
Sistema de Condução Cardíaco/embriologia , Taquicardia por Reentrada no Nó Atrioventricular/etiologia , Animais , Feminino , Sistema de Condução Cardíaco/fisiologia , Camundongos , Camundongos Transgênicos , Gravidez , Taquicardia por Reentrada no Nó Atrioventricular/patologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...