Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Clin Cardiol ; 24(7): 500-2, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11444640

RESUMO

BACKGROUND: Internal cardioversion of atrial fibrillation with direct current energy has become an increasingly employed technique for patients who fail external cardioversion. HYPOTHESIS: The purpose of this study was to determine whether internal cardioversion could be avoided by careful attention to cardioversion technique in a group of patients referred specifically for internal cardioversion after failed external cardioversion by community cardiologists. METHODS: We performed external cardioversion utilizing two operators applying significant pressure to the thorax with up to 360 J prior to the planned internal cardioversion in 20 patients referred for internal cardioversion after failed attempts at external cardioversion. RESULTS: Sixteen patients (80%) were successfully cardioverted and avoided the risk, inconvenience, and cost of internal cardioversion. CONCLUSION: External cardioversion with significant anterior paddle pressure by two operators can decrease the need for internal cardioversion in a significant portion of patients referred to electrophysiologists for internal cardioversion and should be considered prior to an invasive procedure.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Falha de Tratamento
2.
J Electrocardiol ; 34 Suppl: 143-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11781948

RESUMO

We compared the response of endocardial lead systems to radiofrequency (RF) current delivered during atrio-ventricular junction ablation (AVJA) for atrial fibrillation with uncontrolled ventricular rate in 107 patients. The mean age was 67 +/- 11 years and the mean ejection fraction 42 +/- 15%. Patients were divided into 3 groups based on the type of ventricular lead present at the time of ablation: a previously implanted defibrillator lead (group 3, n = 13), a previously implanted pacemaker lead (group 2, n = 46) or a temporary lead (group 1, n = 48), which was subsequently followed by a permanent lead implantation. During AVJA, a median of 5 RF applications (44 +/- 8 W) were given via 4-5-mm electrodes. All but 1 patient had right-sided lesions, while 6 patients also had left sided lesions. Ventricular pacing thresholds were evaluated immediately pre- and post-ablation at 24 hours and at 1 to 3 months. Increases in ventricular pacing voltage thresholds were noted in all 3 groups over time, with the greatest mean increase in group 3 patients: [table: see text]. A greater than 2-fold increase in pacing thresholds was observed only with previously implanted leads, usually within the first 48 hours. It occurred significantly more often in patients with group 3 (6/13 [46%]) compared to group 2 (6/46 [13%], odds ratio 7.6, P = 0.006). A progressive rise in pacing threshold required lead revision in 2/13 group 3 patients (15%) and 2/46 group 2 patients (4%). While RF current has only minor effects on pacing threshold in most patients with previously implanted ventricular lead systems, clinically important alterations requiring device reprogramming or lead revision may occur. Group 3 are significantly more vulnerable to RF current, though the mechanisms are unclear. Group 1 during AVJA, followed by permanent lead implantation appears advisable. Pts with a previously implanted group 3 who require AVJA should be monitored closely.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Nó Atrioventricular/cirurgia , Estimulação Cardíaca Artificial , Estudos de Casos e Controles , Eletrodos Implantados , Humanos , Radiação , Estudos Retrospectivos , Fatores de Tempo
3.
J Am Coll Cardiol ; 36(7): 2247-53, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11127468

RESUMO

OBJECTIVES: The goal of this study was to compare T-wave alternans (TWA), signal-averaged electrocardiography (SAECG) and programmed ventricular stimulation (EPS) for arrhythmia risk stratification in patients undergoing electrophysiology study. BACKGROUND: Accurate identification of patients at increased risk for sustained ventricular arrhythmias is critical to prevent sudden cardiac death. T-wave alternans is a heart rate dependent measure of repolarization that correlates with arrhythmia vulnerability in animal and human studies. Signal-averaged electrocardiography and EPS are more established tests used for risk stratification. METHODS: This was a prospective, multicenter trial of 313 patients in sinus rhythm who were undergoing electrophysiologic study. T-wave alternans, assessed with bicycle ergometry, and SAECG were measured before EPS. The primary end point was sudden cardiac death, sustained ventricular tachycardia, ventricular fibrillation or appropriate implantable defibrillator (ICD) therapy, and the secondary end point was any of these arrhythmias or all-cause mortality. RESULTS: Kaplan-Meier survival analysis of the primary end point showed that TWA predicted events with a relative risk of 10.9, EPS had a relative risk of 7.1 and SAECG had a relative risk of 4.5. The relative risks for the secondary end point were 13.9, 4.7 and 3.3, respectively (p < 0.05). Multivariate analysis of 11 clinical parameters identified only TWA and EPS as independent predictors of events. In the prespecified subgroup with known or suspected ventricular arrhythmias, TWA predicted primary end points with a relative risk of 6.1 and secondary end points with a relative risk of 8.0. CONCLUSIONS: T-wave alternans is a strong independent predictor of spontaneous ventricular arrhythmias or death. It performed as well as programmed stimulation and better than SAECG in risk stratifying patients for life-threatening arrhythmias.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas , Idoso , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Morte Súbita Cardíaca , Teste de Esforço , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Análise de Sobrevida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia
4.
Circulation ; 101(3): 270-9, 2000 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-10645923

RESUMO

BACKGROUND: Data from experimental models of atrial flutter indicate that macro-reentrant circuits may be confined by anatomic and functional barriers remote from the tricuspid annulus-eustachian ridge atrial isthmus. Data characterizing the various forms of atypical atrial flutter in humans are limited. METHODS AND RESULTS: In 6 of 160 consecutive patients referred for ablation of counterclockwise and/or clockwise typical atrial flutter, an additional atypical atrial flutter was mapped to the right atrial free wall. Five patients had no prior cardiac surgery. Incisional atrial tachycardia was excluded in the remaining patient. High-density electroanatomic maps of the reentrant circuit were obtained in 3 patients. Radiofrequency energy application from a discrete midlateral right atrial central line of conduction block to the inferior vena cava terminated and prevented the reinduction of atypical atrial flutter in each patient. Atrial flutter has not recurred in any patient (follow-up, 18+/-17 months; range, 3 to 40 months). CONCLUSIONS: Atrial flutter can arise in the right atrial free wall. This form of atypical atrial flutter could account for spontaneous or inducible atrial flutter observed in patients referred for ablation and is eliminated with linear ablation directed at the inferolateral right atrium.


Assuntos
Flutter Atrial/etiologia , Idoso , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Interv Card Electrophysiol ; 3(3): 253-6, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10490482

RESUMO

Pectoral implantation of transvenous non-thoracotomy internal cardioverter defibrillators (ICD) has resulted in very few complications whether placed subpectorally or subcutaneously. We report the case of a 68 year old man with a subpectorally implanted MINI-plus (Cardiac Pacemakers, Incorporated, St. Paul, Mn.) transvenous ICD who developed nearly instantaneous severe ipsilateral shoulder pain and immobilization. The symptoms progressed despite aggressive physical therapy. We elected to remove the device from the pectoral site and place it in a traditional abdominal position due to the severity, duration and refractoriness of his symptoms. This procedure utilized the chronic Endotak DSP (Model 0125, Cardiac Pacemakers, Incorporated) transvenous lead, a compatible Endotak DSP lead extender (Model 6952, Cardiac Pacemakers, Incorporated) and the above described ICD. Immediate relief of symptoms was accomplished by relocation of the device to an abdominal site. This intervention should be reserved for patients with severely debilitating symptoms. Prospective comparison of subpectoral and subcutaneous surgical approaches with respect to patient comfort and acceptance and complications may be warranted.


Assuntos
Artralgia/etiologia , Desfibriladores Implantáveis/efeitos adversos , Articulação do Ombro , Idoso , Artralgia/fisiopatologia , Artralgia/reabilitação , Seguimentos , Humanos , Masculino , Músculos Peitorais , Modalidades de Fisioterapia , Amplitude de Movimento Articular , Síndrome
6.
Am J Cardiol ; 83(3): 455-8, A9-10, 1999 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-10072243

RESUMO

Three patients with typical atrioventricular nodal reentrant tachycardia (AVNRT) and markedly prolonged PR intervals (>300 ms) without dual pathway physiology at baseline or during isoproterenol infusion underwent successful fast pathway ablation and remained asymptomatic without recurrent AVNRT, atrioventricular block, or symptomatic bradycardia for a mean of 19 months. In patients with recurrent AVNRT and markedly prolonged PR intervals, selective ablation of the retrograde fast pathway can eliminate AVNRT without further impairment of anterograde atrioventricular nodal function.


Assuntos
Fascículo Atrioventricular/cirurgia , Ablação por Cateter , Eletrocardiografia Ambulatorial , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Agonistas Adrenérgicos beta/administração & dosagem , Agonistas Adrenérgicos beta/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular/efeitos dos fármacos , Fascículo Atrioventricular/fisiopatologia , Doença Crônica , Seguimentos , Humanos , Infusões Intravenosas , Isoproterenol/administração & dosagem , Isoproterenol/uso terapêutico , Pessoa de Meia-Idade , Recidiva , Taquicardia por Reentrada no Nó Atrioventricular/tratamento farmacológico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 21(9): 1802-9, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9744446

RESUMO

The advent of catheter ablation stimulated extensive research into anatomical localization of the pathways involved in atrioventricular nodal reentrant tachycardia (AVNRT). Conventional electrophysiological methods that attempt to correlate intracardiac electrograms with two-dimensional fluoroscopic anatomy are limited by the relative inaccuracy and poor reproducibility of this technique, and the requirement for high levels of radiation exposure. A new method of nonfluoroscopic electroanatomical mapping utilizes magnetic field sensing with a specialized catheter to construct three-dimensional electroanatomical endocardial maps of selected heart chambers with spatial resolution of < 1 mm. This system can be used in patients undergoing catheter ablation for AVNRT to create accurate maps of Koch's triangle and to guide application of radiofrequency energy. Initial experience in 14 patients suggests efficacy and safety comparable to conventional mapping and ablation techniques. Further evaluation may confirm the potential benefits of this system with respect to success rates, complications, procedure time, and radiation exposure.


Assuntos
Ablação por Cateter/instrumentação , Eletrocardiografia/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Gráficos por Computador , Humanos , Sensibilidade e Especificidade , Software , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Resultado do Tratamento
9.
Circulation ; 98(4): 315-22, 1998 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-9711936

RESUMO

BACKGROUND: The occurrence of atrial fibrillation after ablation of type I atrial flutter remains an important clinical problem. To gain further insight into the pathogenesis and significance of postablation atrial fibrillation, we examined the time to onset, determinants, and clinical course of atrial fibrillation after ablation of type I flutter in a large patient cohort. METHODS AND RESULTS: Of 110 consecutive patients with ablation of type I atrial flutter, atrial fibrillation was documented in 28 (25%) during a mean follow-up of 20.1+/-9.2 months (cumulative probability of 12% at 1 month, 23% at 1 year, and 30% at 2 years). Among 17 clinical and procedural variables, only a history of spontaneous atrial fibrillation (relative risk 3.9, 95% confidence intervals 1.8 to 8.8, P=0.001) and left ventricular ejection fraction <50% (relative risk 3.8, 95% confidence intervals 1.7 to 8.5, P=0.001) were significant and independent predictors of subsequent atrial fibrillation. The presence of both these characteristics identified a high-risk group with a 74% occurrence of atrial fibrillation. Patients with only 1 of these characteristics were at intermediate risk (20%), and those with neither characteristic were at lowest risk (10%). The determinants and clinical course of atrial fibrillation did not differ between an early (< or = 1 month) compared with a later onset. Atrial fibrillation was persistent and recurrent, requiring long-term therapy in 18 patients, including 12 of 19 (63%) with prior atrial fibrillation and left ventricular dysfunction. CONCLUSIONS: Atrial fibrillation after type I flutter ablation is primarily determined by the presence of a preexisting structural and electrophysiological substrate. These data should be considered in planning postablation management. The persistent risk of atrial fibrillation in this population also suggests a potentially important role for atrial fibrillation as a trigger rather than a consequence of type I atrial flutter.


Assuntos
Fibrilação Atrial/etiologia , Flutter Atrial/complicações , Flutter Atrial/cirurgia , Ablação por Cateter , Complicações Pós-Operatórias , Idoso , Fibrilação Atrial/terapia , Flutter Atrial/fisiopatologia , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Tempo , Resultado do Tratamento
10.
J Electrocardiol ; 31 Suppl: 92-100, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9988011

RESUMO

Recent data emphasize the importance of structural factors in the pathophysiology of atrial arrhythmias. As a consequence, catheter ablation increasingly has become an anatomically oriented procedure. A recently developed magnetic catheter tracking system provides spatially precise and realistic three-dimensional reconstructions of endocardial geometry. A variety of electrophysiologic data can be superimposed on these reconstructions, including activation sequence, electrogram amplitude and morphologic features, response to pacing maneuvers, and sites of planned or delivered radiofrequency energy ablation. These features enhance the ability to analyze and visualize arrhythmia mechanisms, plan and execute appropriate ablation strategies, and provide new opportunities for physiologic research.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Átrios do Coração/patologia , Sistema de Condução Cardíaco/patologia , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Eletrocardiografia , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
11.
Am J Cardiol ; 80(5B): 20F-27F, 1997 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-9291446

RESUMO

Death due to ventricular tachyarrhythmia (VT) remains an important public health problem; patients with prior myocardial infarction (MI) constitute the largest identifiable population for prophylactic interventions. Targeting of progressively higher-risk subgroups of post-MI survivors carries inevitable tradeoffs with respect to the global impact of interventions on overall mortality. Therapy with aspirin, beta blockers, and angiotensin-converting enzyme (ACE) inhibitors comprise the benchmark against which all additional interventions, including implantable defibrillators, must be measured. Initial enthusiasm for empiric amiodarone therapy has been tempered by the limited benefit demonstrated in recent randomized trials. Trials of other class III antiarrhythmic drugs, including both d,l-sotalol and d-sotalol, have also failed to demonstrate survival benefit. The Multicenter Automatic Defibrillator Implantation Trial (MADIT) demonstrated significantly improved survival associated with defibrillators in a small subgroup of post-MI survivors with a high short-term risk of death. The ultimate number and optimal criteria for selection of patients who may benefit from prophylactic defibrillator therapy after MI will undergo continued evolution as new data from current and ongoing trials become available.


Assuntos
Antiarrítmicos/uso terapêutico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Taquicardia Ventricular/prevenção & controle , Amiodarona/uso terapêutico , Causas de Morte , Humanos , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/complicações , Ensaios Clínicos Controlados Aleatórios como Assunto , Taxa de Sobrevida , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade
12.
Hosp Pract (1995) ; 32(5): 143-4, 149-50, 153-9 passim, 1997 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-9153143

RESUMO

Newer antiarrhythmic agents can control atrial flutter and fibrillation in many patients, although individual episodes may require cardioversion. Catheter ablation is often curative for refractory flutter. Ablation of atrial fibrillation is more difficult, because of its different mechanism. Surgical and catheter-based ablation procedures have been pioneered for fibrillation but remain experimental.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Ablação por Cateter , Cardioversão Elétrica , Idoso , Algoritmos , Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Hipertensivos/administração & dosagem , Aspirina/administração & dosagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Diagnóstico Diferencial , Diltiazem/administração & dosagem , Eletrocardiografia , Humanos , Masculino , Recidiva
13.
J Cardiovasc Electrophysiol ; 8(1): 11-23, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9116962

RESUMO

INTRODUCTION: Distinct surface ECG morphologies (ECGMs), from one episode to the next, of recurrent monomorphic ventricular tachycardia (VT) in the same patient complicate endocardial catheter mapping and the success of ablative therapy. This study investigates the incidence and mechanisms of multiple ECGMs during recurrent monomorphic VTs in a canine model of experimental myocardial infarction (MI). METHODS AND RESULTS: Computerized ECG analysis and simultaneous endocardial and epicardial activation mapping with a 64 bipolar electrode array were used to analyze the relation between site of VT origin, local activation sequence, and surface ECGM in 72 VT episodes induced in 9 of 17 dogs with experimental MI. Pairwise comparisons of all VTs induced in the same animal were done in drug-free state (47 VTs) and after intravenous procainamide (25 VTs). In drug-free state, VT pairs with similar surface ECGMs manifested endocardial breakthrough sites (BSs) within a distance < 10 mm in 46 (100%) of 46 VT pairs compared to 43 (45%) of 95 VT pairs with different surface ECGMs (P < 0.0001). Of all 89 VT pairs with endocardial BSs within < 10 mm, similar endocardial activation patterns were found in 34 (74%) of 46 pairs with similar ECGMs in contrast to 6 (14%) of 43 pairs with different ECGMs (P < 0.001). Similar comparisons of VT pairs induced after intravenous procainamide administration showed that the endocardial BSs were located within < 10 mm in 9 (75%) of 12 VT pairs with similar and in 17 (49%) of 95 with different surface ECGMs, respectively (P = NS). CONCLUSIONS: In the same heart, similar surface ECGMs of recurrent VT are highly predictive of closely spaced endocardial BSs in drug-free state, but not after procainamide administration. Nearly half of the VTs with different surface ECGMs still originate from closely spaced endocardial BSs but commonly manifest a change in the endocardial activation spread from this site. Thus, assumptions about different mechanisms and sites of VT origin based on different surface ECGMs should be made with caution.


Assuntos
Antiarrítmicos/administração & dosagem , Eletrocardiografia/efeitos dos fármacos , Infarto do Miocárdio/fisiopatologia , Procainamida/administração & dosagem , Fibrilação Ventricular/fisiopatologia , Animais , Cães , Injeções Intravenosas , Fibrilação Ventricular/tratamento farmacológico
14.
J Cardiovasc Electrophysiol ; 8(1): 80-8, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9116972

RESUMO

INTRODUCTION: Bundle branch reentry is an uncommon mechanism for ventricular tachycardia. More infrequently, both fascicles of the left bundle may provide the substrate for such macroreentrant bundle branch circuits, so-called interfascicular reentry. The effect of adenosine on bundle branch reentrant mechanisms of tachycardia is unknown. METHODS AND RESULTS: A 59-year-old man with no apparent structural heart disease and history of frequent symptomatic wide complex tachycardias was referred to our center for further electrophysiologic evaluation. During electrophysiologic study, a similar tachycardia was reproducibly initiated only during isoproterenol infusion, which had the characteristics of bundle branch reentry, possibly using a left interfascicular mechanism. Intravenous adenosine reproducibly terminated the tachycardia. Application of radiofrequency energy to the breakout site from the left posterior fascicle prevented subsequent tachycardia induction and rendered the patient free of spontaneous tachycardia during long-term follow-up. CONCLUSIONS: Patients with ventricular tachycardia involving a bundle branch reentrant circuit may be sensitive to adenosine. These results suggest that adenosine may not only inhibit catecholamine-mediated triggered activity but also some catecholamine-mediated reentrant ventricular arrhythmias.


Assuntos
Adenosina/administração & dosagem , Antiarrítmicos/administração & dosagem , Bloqueio de Ramo , Taquicardia/tratamento farmacológico , Administração Oral , Eletrocardiografia , Humanos , Masculino , Taquicardia/etiologia , Taquicardia/fisiopatologia
15.
Circulation ; 94(10): 2507-14, 1996 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-8921795

RESUMO

BACKGROUND: The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience with truncated biphasic waveforms in implantable cardioverter-defibrillators, we compared the efficacy of a truncated biphasic waveform with that of a standard damped sine monophasic waveform for transthoracic defibrillation. METHODS AND RESULTS: The principal goal of this multicenter, prospective, randomized, blinded study was to compare the first-shock transthoracic defibrillation efficacy of a 130-J truncated biphasic waveform with that of a standard 200-J monophasic damped sine wave pulse using anterior thoracic pads in the course of implantable cardioverter-defibrillator testing. Pad-pad ECGs were also examined after transthoracic defibrillation. After the elimination of data for 24 patients who did not meet all protocol criteria, the results from 294 patients were analyzed. The 130-J truncated biphasic pulse and the 200-J damped sine wave monophasic pulse resulted in first-shock efficacy rates of 86% and 86%, respectively (P = .97). ST-segment levels measured 10 seconds after the shock in 151 patients in sinus rhythm were -0.26 +/- 1.58 and -1.86 +/- 1.93 mm for the 130- and 200-J shocks, respectively (P < .0001). CONCLUSIONS: We found that 130-J biphasic truncated transthoracic shocks defibrillate as well as the 200-J monophasic damped sine wave shocks that are traditionally used in standard transthoracic defibrillators and result in fewer ECG abnormalities after the shock.


Assuntos
Cardioversão Elétrica/métodos , Fibrilação Ventricular/terapia , Adolescente , Adulto , Idoso , Eletrocardiografia , Estudos de Avaliação como Assunto , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Fibrilação Ventricular/fisiopatologia
16.
Am J Cardiol ; 78(10): 1113-8, 1996 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-8914873

RESUMO

This study examines in a prospective, multicenter trial the feasibility and advantage of current-based, transthoracic defibrillation. Current-based, damped, sinusoidal waveform shocks of 18, 25, 30, 35, or 40 amperes (A) were administered beginning with 25 A for polymorphic ventricular tachycardia (VT) and ventricular fibrillation (VF) or 18 A for monomorphic VT; success rates were compared with those of energy-based shocks beginning at 200 J for VF/polymorphic VT and 100 J for VT. The current-based shocks were delivered from custom-modified defibrillators that determined impedance in advance of any shock using a "test-pulse" technique; the capacitor then charged to the exact energy necessary to deliver the operator-selected current against the impedance determined by the defibrillator. Three hundred sixty-two patients received > 1 shock for VF, polymorphic VT, or monomorphic VT: 569 current- based shocks and 420 energy-based shocks. Current-based shocks of 35/40 A achieved success rates of up to 74% for VF/polymorphic VT; 30 A shocks terminated 88% of monomorphic VT episodes. Energy-based shocks of 300 J terminated 72% of VF/polymorphic VT; 200-J shocks terminated 89% of monomorphic VT. We could not demonstrate a significant increase in the success rate of current-based shocks over energy-based shocks for patients with high transthoracic impedance; this may be due to inadequate sample size. Thus, current-based defibrillation is clinically feasible and effective. A larger study will be needed to test whether current-based defibrillation is superior to energy-based defibrillation.


Assuntos
Cardioversão Elétrica/métodos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Impedância Elétrica , Estudos de Viabilidade , Humanos , Estudos Prospectivos
17.
Curr Opin Cardiol ; 11(1): 23-31, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8664529

RESUMO

The clinical significance of nonsustained ventricular tachycardia continues to undergo reevaluation as clinicians attempt to optimize screening strategies for identifying high-risk patients and to evaluate the efficacy of therapeutic interventions. The utility of ambulatory monitoring and programmed stimulation as screening tools in the patient who has suffered an infarction remains unsettled; ongoing clinical trials may help resolve these issues. New data suggest that the survival benefit associated with angiotensin-converting enzyme inhibition is unrelated to effects on spontaneous arrhythmias, similar to results previously reported for beta-blockers. Randomized clinical trials of prophylactic amiodarone in patients with congestive heart failure and nonsustained ventricular tachycardia have produced conflicting results. A strong relationship between polymorphic nonsustained ventricular tachycardia and sudden death in patients without structural heart disease or QT prolongation has been reported. The significance of nonsustained ventricular tachycardia in dilated cardiomyopathy and hypertrophic cardiomyopathy has also been reassessed.


Assuntos
Taquicardia Ventricular/terapia , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Cardiomegalia/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Eletrocardiografia , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/mortalidade , Vasodilatadores/uso terapêutico
18.
Circulation ; 92(11): 3264-72, 1995 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-7586313

RESUMO

BACKGROUND: Oral amiodarone effectively suppresses ventricular arrhythmias; however, full activity may take days or weeks. In patients with frequent, life-threatening ventricular arrhythmias, this delay is not acceptable. Thus, in these patients, the speed and dosing accuracy of an intravenous formulation would be beneficial. The goal of this study was to demonstrate the efficacy of intravenous amiodarone in patients with refractory, recurrent hemodynamically destabilizing ventricular tachycardia or ventricular fibrillation by determining a dose response among three regimens. METHODS AND RESULTS: A total of 342 patients were enrolled at 46 medical centers in the United States. Patients received one of three randomized, double-blind dose regimens delivering 125, 500, or 1000 mg during the first 24 hours. Supplemental infusions (150 mg) of intravenous amiodarone could be given to treat breakthrough ventricular arrhythmias. The key efficacy end points were the arrhythmia event rate, time to first arrhythmic event, and number of supplemental infusions administered. The event rate decreased with increasing doses: median values were 0.07, 0.04, and 0.02 events per hour for the 125-, 500-, and 1000-mg dose groups, respectively, representing a significant decrease from baseline event rates (P = .043), and approached significance in the overall test for trend (P = .067). There was a significant dose-related increase in the time to first event (trend test P = .025) and a significant dose-related decrease in the number of supplemental boluses per hour (trend test P = .043). Hypotension was the most common (26%) treatment-emergent adverse event during intravenous amiodarone therapy; there was no dose-response relationship. Seventy-eight percent of the patients survived to at least 48 hours. CONCLUSIONS: Intravenous amiodarone is effective for the treatment of recurrent, life-threatening ventricular tachyarrhythmias.


Assuntos
Amiodarona/administração & dosagem , Antiarrítmicos/administração & dosagem , Taquicardia Ventricular/tratamento farmacológico , Fibrilação Ventricular/tratamento farmacológico , Amiodarona/efeitos adversos , Antiarrítmicos/efeitos adversos , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Hipotensão/induzido quimicamente , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Fibrilação Ventricular/mortalidade
19.
Circulation ; 92(12): 3481-9, 1995 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-8521570

RESUMO

BACKGROUND: Intraoperative mapping studies suggest that an isthmus of myocardium between the mitral valve annulus and the border of inferior myocardial infarction may play a role in the genesis of ventricular tachycardia. We examined the frequency with which a slow conduction zone within the mitral isthmus was critical to the maintenance of ventricular tachycardia associated with remote inferior infarction in patients undergoing catheter ablation. METHODS AND RESULTS: In 4 of 12 patients, a critical zone of slow conduction was identified within the mitral isthmus. In each of these patients, two characteristic and morphologically distinct tachycardias were induced: a left bundle (rS in V1, R in V6), left superior axis morphology and a right bundle (R in V1, QS in V6), right superior axis morphology (cycle length, 610 to 320 ms). In each patient, a zone of slow conduction, shared by both morphologies, was characterized by diastolic potentials with electrogram-QRS intervals of 85 to 161 ms (21% to 47% of tachycardia cycle length) and entrainment with concealed fusion during pacing associated with stimulus-QRS intervals of 81 to 400 ms (20% to 91% of tachycardia cycle length). In each patient, a single radiofrequency energy application at the shared site of slow conduction eliminated inducibility of both morphologies. During follow-up of 1 to 11 months, no patient had recurrent tachycardia. CONCLUSIONS: The mitral isthmus contains a critical region of slow conduction in some patients with ventricular tachycardia after inferior myocardial infarction, providing a vulnerable and anatomically localized target for catheter ablation. Characteristic tachycardia morphologies may provide clinical markers for this underlying mechanism.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Infarto do Miocárdio/complicações , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Cateterismo Cardíaco , Estimulação Cardíaca Artificial , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral , Miocárdio , Taquicardia Ventricular/diagnóstico , Fatores de Tempo
20.
Pacing Clin Electrophysiol ; 18(2): 253-60, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7731873

RESUMO

The determinants of high defibrillation energy requirements (DER) using nonepicardial lead systems (NELS) have not been well characterized. The goal of this study was to examine prospectively the influence of clinical, radiographic, echocardiographic, and procedural variables on DER during NELS placement. Data from 100 consecutive patients undergoing attempted NELS implantation were analyzed. Transvenous leads, subcutaneous patches, and monophasic shock devices from two manufacturers were used. Leads were successfully positioned for testing in 95% of patients. An adequate DER (< or = 25 J) was obtained in 73 of 95 (77%) of patients. Univariate analysis identified amiodarone therapy and left ventricular mass as predictors of high DER. With multivariate analysis, amiodarone therapy was the sole significant predictor of high DER (P = 0.002, odds ratio 5.46). The 22 patients with high NELS DER also had high epicardial DER (mean 24 +/- 9 J). The two patch epicardial DER was > 25 joules in 12 of 22 patients. Thus, adequate DER with monophasic shock waveforms can be obtained in most patients undergoing NELS testing. However, amiodarone therapy significantly increases the probability of obtaining high DER.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Amiodarona/uso terapêutico , Cardioversão Elétrica/métodos , Eletrodos Implantados , Desenho de Equipamento , Feminino , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...