Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 576
Filtrar
1.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747976

RESUMO

BACKGROUND AND AIMS: Brugada syndrome (BrS) is an inherited arrhythmia with a higher disease prevalence and more lethal arrhythmic events in Asians than in Europeans. Genome-wide association studies (GWAS) have revealed its polygenic architecture mainly in European populations. The aim of this study was to identify novel BrS-associated loci and to compare allelic effects across ancestries. METHODS: A GWAS was conducted in Japanese participants, involving 940 cases and 1634 controls, followed by a cross-ancestry meta-analysis of Japanese and European GWAS (total of 3760 cases and 11 635 controls). The novel loci were characterized by fine-mapping, gene expression, and splicing quantitative trait associations in the human heart. RESULTS: The Japanese-specific GWAS identified one novel locus near ZSCAN20 (P = 1.0 × 10-8), and the cross-ancestry meta-analysis identified 17 association signals, including six novel loci. The effect directions of the 17 lead variants were consistent (94.1%; P for sign test = 2.7 × 10-4), and their allelic effects were highly correlated across ancestries (Pearson's R = .91; P = 2.9 × 10-7). The genetic risk score derived from the BrS GWAS of European ancestry was significantly associated with the risk of BrS in the Japanese population [odds ratio 2.12 (95% confidence interval 1.94-2.31); P = 1.2 × 10-61], suggesting a shared genetic architecture across ancestries. Functional characterization revealed that a lead variant in CAMK2D promotes alternative splicing, resulting in an isoform switch of calmodulin kinase II-δ, favouring a pro-inflammatory/pro-death pathway. CONCLUSIONS: This study demonstrates novel susceptibility loci implicating potentially novel pathogenesis underlying BrS. Despite differences in clinical expressivity and epidemiology, the polygenic architecture of BrS was substantially shared across ancestries.

2.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38591264

RESUMO

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Incidência , Função Ventricular Esquerda , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Sistema de Registros , Fatores de Risco
3.
Heart Rhythm O2 ; 5(3): 182-188, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560377

RESUMO

Background: Recent studies suggest that participation in recreational and even competitive sports is generally safe for patients with implantable cardioverter-defibrillators (ICDs). However, these studies included only patients with implanted transvenous ICD (TV-ICD). Nowadays, subcutaneous ICD (S-ICD) is a safe and effective alternative and is increasingly implanted in younger ICD candidates. Data on the safety of sport participation for patients with implanted S-ICD systems is urgently needed. Objectives: The goal of the study is to quantify the risks (or determine the safety) of sports participation for athletes with an S-ICD, which will guide shared decision making for athletes requiring an ICD and/or wishing to return to sports after implantation. Methods: The SPORT S-ICD (Sports for Patients with Subcutaneous Implantable Cardioverter Defibrillator) study is an international, multicenter, prospective, noninterventional, observational study, designed specifically to collect data on the safety of sports participation among patients with implanted S-ICD systems who regularly engage in sports activities. Results: A total of 450 patients will undergo baseline assessment including baseline characteristics, indication for S-ICD implantation, arrhythmic history, S-ICD data and programming, and data regarding sports activities. LATITUDE Home Monitoring information will be regularly transferred to the study coordinator for analysis. Conclusion: The results of the study will aid in shaping clinical decision making, and if the tested hypothesis will be proven, it will allow the safe continuation of sports for patients with an implanted S-ICD.

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38558121

RESUMO

AIMS: Recently, a genetic variant-specific prediction model for phospholamban (PLN) p.(Arg14del)-positive individuals was developed to predict individual major ventricular arrhythmia (VA) risk to support decision-making for primary prevention implantable cardioverter defibrillator (ICD) implantation. This model predicts major VA risk from baseline data, but iterative evaluation of major VA risk may be warranted considering that the risk factors for major VA are progressive. Our aim is to evaluate the diagnostic performance of the PLN p.(Arg14del) risk model at 3-year follow-up. METHODS AND RESULTS: We performed a landmark analysis 3 years after presentation and selected only patients with no prior major VA. Data were collected of 268 PLN p.(Arg14del)-positive subjects, aged 43.5 ± 16.3 years, 38.9% male. After the 3 years landmark, subjects had a mean follow-up of 4.0 years (± 3.5 years) and 28 (10%) subjects experienced major VA with an annual event rate of 2.6% [95% confidence interval (CI) 1.6-3.6], defined as sustained VA, appropriate ICD intervention, or (aborted) sudden cardiac death. The PLN p.(Arg14del) risk score yielded good discrimination in the 3 years landmark cohort with a C-statistic of 0.83 (95% CI 0.79-0.87) and calibration slope of 0.97. CONCLUSION: The PLN p.(Arg14del) risk model has sustained good model performance up to 3 years follow-up in PLN p.(Arg14del)-positive subjects with no history of major VA. It may therefore be used to support decision-making for primary prevention ICD implantation not merely at presentation but also up to at least 3 years of follow-up.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Proteínas de Ligação ao Cálcio/genética , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Reprodutibilidade dos Testes , Fatores de Risco , Adulto , Pessoa de Meia-Idade
5.
Cardiol Young ; : 1-8, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653721

RESUMO

Despite its low prevalence, the potential diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT) should be at the forefront of a paediatric cardiologists mind in children with syncope during exercise or emotions. Over the years, the number of children with a genetic diagnosis of CPVT due to a (likely) pathogenic RYR2 variant early in life and prior to the onset of symptoms has increased due to cascade screening programmes. Limited guidance for this group of patients is currently available. Therefore, we aimed to summarise currently available literature for asymptomatic patients with a (likely) pathogenic RYR2 variant, particularly the history of CPVT and its genetic architecture, the currently available diagnostic tests and their limitations, and the development of a CPVT phenotype - both electrocardiographically and symptomatic - of affected family members. Their risk of arrhythmic events is presumably low and a phenotype seems to develop in the first two decades of life. Future research should focus on this group in particular, to better understand the development of a phenotype over time, and therefore, to be able to better guide clinical management - including the frequency of diagnostic tests, the timing of the initiation of drug therapy, and lifestyle recommendations.

6.
Neth Heart J ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653923

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (iVF) is a rare cause of sudden cardiac arrest and, by definition, a diagnosis of exclusion. Due to the rarity of the disease, previous and current studies are limited by their retrospective design and small patient numbers. Even though the incidence of iVF has declined owing to the identification of new disease entities, an important subgroup of patients remains. AIM: To expand the existing Dutch iVF Registry into a large nationwide cohort of patients initially diagnosed with iVF, to reveal the underlying cause of iVF in these patients, and to improve arrhythmia management. METHODS: The Dutch iVF Registry includes sudden cardiac arrest survivors with an initial diagnosis of iVF. Clinical data and outcomes are collected. Outcomes include subsequent detection of a diagnosis other than 'idiopathic', arrhythmia recurrence and death. Non-invasive electrocardiographic imaging is used to investigate electropathological substrates and triggers of VF. RESULTS: To date, 432 patients have been included in the registry (median age at event 40 years (interquartile range 28-52)), 61% male. During a median follow-up of 6 (2-12) years, 38 patients (9%) received a diagnosis other than 'idiopathic'. Eleven iVF patients were characterised with electrocardiographic imaging. CONCLUSION: The Dutch iVF Registry is currently the largest of its kind worldwide. In this heterogeneous population of index patients, we aim to identify common functional denominators associated with iVF. With the implementation of non-invasive electrocardiographic imaging and other diagnostic modalities (e.g. echocardiographic deformation, cardiac magnetic resonance), we advance the possibilities to reveal pro-fibrillatory substrates.

7.
Neth Heart J ; 32(5): 190-197, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38634993

RESUMO

International guidelines recommend implantation of an implantable cardioverter-defibrillator (ICD) in non-ischaemic cardiomyopathy (NICM) patients with a left ventricular ejection fraction (LVEF) below 35% despite optimal medical therapy and a life expectancy of more than 1 year with good functional status. We propose refinement of these recommendations in patients with NICM, with careful consideration of additional risk parameters for both arrhythmic and non-arrhythmic death. These additional parameters include late gadolinium enhancement on cardiac magnetic resonance imaging and genetic testing for high-risk genetic variants to further assess arrhythmic risk, and age, comorbidities and sex for assessment of non-arrhythmic mortality risk. Moreover, several risk modifiers should be taken into account, such as concomitant arrhythmias that may affect LVEF (atrial fibrillation, premature ventricular beats) and resynchronisation therapy. Even though currently no valid cut-off values have been established, the proposed approach provides a more careful consideration of risks that may result in withholding ICD implantation in patients with low arrhythmic risk and substantial non-arrhythmic mortality risk.

8.
Heart Rhythm ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38670247

RESUMO

BACKGROUND: Implantable cardiac defibrillator (ICD) implantation can protect against sudden cardiac death after myocardial infarction. However, improved risk stratification for device requirement is still needed. OBJECTIVE: The purpose of this study was to improve assessment of postinfarct ventricular electropathology and prediction of appropriate ICD therapy by combining late gadolinium enhancement (LGE) and advanced computational modeling. METHODS: ADAS 3D LV (ADAS LV Medical, Barcelona, Spain) and custom-made software were used to generate 3-dimensional patient-specific ventricular models in a prospective cohort of postinfarct patients (N = 40) having undergone LGE imaging before ICD implantation. Corridor metrics and 3-dimensional surface features were computed from LGE images. The Virtual Induction and Treatment of Arrhythmias (VITA) framework was applied to patient-specific models to comprehensively probe the vulnerability of the scar substrate to sustaining reentrant circuits. Imaging and VITA metrics, related to the numbers of induced ventricular tachycardias and their corresponding round trip times (RTTs), were compared with ICD therapy during follow-up. RESULTS: Patients with an event (n = 17) had a larger interface between healthy-scar and higher VITA metrics. Cox regression analysis demonstrated a significant independent association with an event: interface (hazard ratio [HR] 2.79; 95% confidence interval [CI] 1.44-5.44; P < .01), unique ventricular tachycardias (HR 1.67; 95% CI 1.04-2.68; P = .03), mean RTT (HR 2.14; 95% CI 1.11-4.12; P = .02), and maximum RTT (HR 2.13; 95% CI 1.19-3.81; P = .01). CONCLUSION: A detailed quantitative analysis of LGE-based scar maps, combined with advanced computational modeling, can accurately predict ICD therapy and could facilitate the early identification of high-risk patients in addition to left ventricular ejection fraction.

9.
Heart Rhythm ; 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38588993

RESUMO

BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) may cause sudden cardiac death (SCD) despite medical therapy. Therefore, implantable cardioverter-defibrillators (ICDs) are commonly advised. However, there are limited data on the outcomes of ICD use in children. OBJECTIVE: The purpose of this study was to compare the risk of arrhythmic events in pediatric patients with CPVT with and without ICD. METHODS: We compared the risk of SCD in patients with RYR2 (ryanodine receptor 2) variants and phenotype-positive symptomatic patients with CPVT with and without ICD who were younger than 19 years and had no history of sudden cardiac arrest at phenotype diagnosis. The primary outcome was SCD; secondary outcomes were composite end points of SCD, sudden cardiac arrest, or appropriate ICD shocks with or without arrhythmic syncope. RESULTS: The study included 235 patients, 73 with ICD (31.1%) and 162 without ICD (68.9%). Over a median follow-up of 8.0 years (interquartile range 4.3-13.4 years), SCD occurred in 7 patients (3.0%), of whom 4 (57.1%) were noncompliant with medications and none had an ICD. Patients with ICD had a higher risk of both secondary composite outcomes (without syncope: hazard ratio 5.85; 95% confidence interval 3.40-10.09; P < .0001; with syncope: hazard ratio 2.55; 95% confidence interval 1.50-4.34; P = .0005). Thirty-one patients with ICD (42.5%) experienced appropriate shocks, 18 (24.7%) inappropriate shocks, and 21 (28.8%) device-related complications. CONCLUSION: SCD events occurred only in the no ICD group and in those not on optimal medical therapy. Patients with ICD had a high risk of appropriate and inappropriate shocks, which may be reduced with appropriate device programming. Severe ICD complications were common, and risks vs benefits of ICDs need to be considered.

10.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493994

RESUMO

BACKGROUND: Current cohorts of patients with idiopathic ventricular fibrillation (IVF) primarily include adult-onset patients. Underlying causes of sudden cardiac arrest vary with age; therefore, underlying causes and disease course may differ for adolescent-onset vs adult-onset patients. OBJECTIVE: The purpose of this study was to compare adolescent-onset with adult-onset patients having an initially unexplained cause of VF. METHODS: The study included 39 patients with an index event aged ≤19 years (adolescent-onset) and 417 adult-onset patients from the Dutch Idiopathic VF Registry. Data on event circumstances, clinical characteristics, change in diagnosis, and arrhythmia recurrences were collected and compared between the 2 groups. RESULTS: In total, 42 patients received an underlying diagnosis during follow-up (median 7 [2-12] years), with similar yields (15% adolescent-onset vs 9% adult-onset; P = .16). Among the remaining unexplained patients, adolescent-onset patients (n = 33) had their index event at a median age of 17 [16-18] years, and 72% were male. The youngest patient was aged 13 years. In comparison with adults (n = 381), adolescent-onset patients more often had their index event during exercise (P <.01). Adolescent-onset patients experienced more appropriate implantable cardioverter-defibrillator (ICD) therapy during follow-up compared with adults (44% vs 26%; P = .03). Inappropriate ICD therapy (26% vs 17%; P = .19), ICD complications (19% vs 14%; P = .41), and deaths (3% vs 4%; P = 1) did not significantly differ between adolescent-onset and adult-onset patients. CONCLUSION: IVF may occur during adolescence. Adolescent-onset patients more often present during exercise compared with adults. Furthermore, they are more vulnerable to ventricular arrhythmias as reflected by a higher incidence of appropriate ICD therapy.

11.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38349347

RESUMO

AIMS: In patients with catecholaminergic polymorphic ventricular tachycardia (CPVT), a rare inherited arrhythmia syndrome, arrhythmic events can be prevented by medication and lifestyle recommendations. In patients who experience breakthrough arrhythmic events, non-adherence plays an essential role. We aimed to investigate the incidence and potential reasons for non-adherence to medication and lifestyle recommendations in a large, international cohort of patients with CPVT. METHODS AND RESULTS: An online multilingual survey was shared with CPVT patients worldwide by their cardiologists, through peer-recruitment, and on social media from November 2022 until July 2023. Self-reported non-adherence was measured using the validated Medication Adherence Rating Scale (MARS) and a newly developed questionnaire about lifestyle. Additionally, validated questionnaires were used to assess potential reasons for medication non-adherence. Two-hundred-and-eighteen patients completed the survey, of whom 200 (92%) were prescribed medication [122 (61%) female; median age 33.5 years (interquartile range: 22-50)]. One-hundred-and-three (52%) were prescribed beta-blocker and flecainide, 85 (43%) beta-blocker, and 11 (6%) flecainide. Thirty-four (17%) patients experienced a syncope, aborted cardiac arrest or appropriate implantable cardioverter defibrillator shock after diagnosis. Nineteen (13.4%) patients were exercising more than recommended. Thirty (15%) patients were non-adherent to medication. Female sex [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.3-12.0, P = 0.019], flecainide monotherapy compared to combination therapy (OR 6.8, 95% CI 1.6-31.0, P = 0.010), and a higher agreement with statements regarding concerns about CPVT medication (OR 1.2, 95% CI 1.1-1.3, P < 0.001) were independently associated with non-adherence. CONCLUSION: The significant rate of non-adherence associated with concerns regarding CPVT-related medication, emphasizes the potential for improving therapy adherence by targeted patient education.


Assuntos
Flecainida , Taquicardia Ventricular , Humanos , Feminino , Adulto , Masculino , Flecainida/efeitos adversos , Antiarrítmicos/uso terapêutico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/epidemiologia , Estilo de Vida , Adesão à Medicação , Canal de Liberação de Cálcio do Receptor de Rianodina
12.
Heart Rhythm ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

13.
Heart Rhythm ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38403235

RESUMO

BACKGROUND: Phospholamban (PLN) p.(Arg14del) variant carriers are at risk for development of malignant ventricular arrhythmia (MVA). Accurate risk stratification allows timely implantation of intracardiac defibrillators and is currently performed with a multimodality prediction model. OBJECTIVE: This study aimed to investigate whether an explainable deep learning-based approach allows risk prediction with only electrocardiogram (ECG) data. METHODS: A total of 679 PLN p.(Arg14del) carriers without MVA at baseline were identified. A deep learning-based variational auto-encoder, trained on 1.1 million ECGs, was used to convert the 12-lead baseline ECG into its FactorECG, a compressed version of the ECG that summarizes it into 32 explainable factors. Prediction models were developed by Cox regression. RESULTS: The deep learning-based ECG-only approach was able to predict MVA with a C statistic of 0.79 (95% CI, 0.76-0.83), comparable to the current prediction model (C statistic, 0.83 [95% CI, 0.79-0.88]; P = .054) and outperforming a model based on conventional ECG parameters (low-voltage ECG and negative T waves; C statistic, 0.65 [95% CI, 0.58-0.73]; P < .001). Clinical simulations showed that a 2-step approach, with ECG-only screening followed by a full workup, resulted in 60% less additional diagnostics while outperforming the multimodal prediction model in all patients. A visualization tool was created to provide interactive visualizations (https://pln.ecgx.ai). CONCLUSION: Our deep learning-based algorithm based on ECG data only accurately predicts the occurrence of MVA in PLN p.(Arg14del) carriers, enabling more efficient stratification of patients who need additional diagnostic testing and follow-up.

14.
BJOG ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326282

RESUMO

OBJECTIVE: Data and guidelines are lacking, so implantable cardioverter-defibrillators (ICDs) are often deactivated during labour to prevent inappropriate shocks. This study aimed to ascertain the safety of an activated ICD during labour. DESIGN: An observational study was performed. SETTING: Dutch hospitals. POPULATION OR SAMPLE: A total of 41 childbirths were included of 26 patients who gave birth between February 2009 and November 2018 after receiving an ICD in our tertiary hospital. Five of these childbirths were attended by the research team between December 2018 and August 2020, during which the ICD remained active. METHODS: Groups were made based on ICD status during labour. Patients who gave birth with an activated ICD at least once were stratified to the activated ICD group. Patients' files were checked and patients received a questionnaire about childbirth perceptions and treatment preferences. The differences in ordinal data resulting from the questionnaire were calculated using a chi-square or Fisher's exact test. MAIN OUTCOME MEASURES: Primary outcome was inappropriate ICD therapy and occurrence of ventricular arrhythmias requiring treatment. RESULTS: During the 41 childbirths, no inappropriate shocks or ventricular arrhythmias occurred during labour. All patients in the activated ICD group (n = 13) preferred this setting, while 8 of the 13 patients in the deactivated ICD group preferred activation (p = 0.002). Reasons included avoiding hemodynamic monitoring, magnet placement, or labour induction to facilitate technician availability. CONCLUSIONS: This study shows no evidence that labour and birth in women with an activated ICD are unsafe, as there were no ventricular arrhythmias or inappropriate therapy. In addition, most patients prefer an activated ICD during labour.

17.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
18.
Heart ; 110(4): 254-262, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37678891

RESUMO

OBJECTIVE: Longitudinal consequences and potential interactions of COVID-19 and elite-level sports and exercise are unclear. Therefore, we determined the long-term detrimental cardiac effects of the interaction between SARS-CoV-2 infection and the highest level of sports and exercise. METHODS: This prospective controlled study included elite athletes from the Evaluation of Lifetime participation in Intensive Top-level sports and Exercise cohort. Athletes infected with SARS-CoV-2were offered structured, additional cardiovascular screenings, including cardiovascular MRI (CMR). We compared ventricular volumes and function, late gadolinium enhancement (LGE) and T1 relaxation times, between infected and non-infected elite athletes, and collected follow-up data on cardiac adverse events, ventricular arrhythmia burden and the cessation of sports careers. RESULTS: We included 259 elite athletes (mean age 26±5 years; 40% women), of whom 123 were infected (9% cardiovascular symptoms) and 136 were controls. We found no differences in function and volumetric CMR parameters. Four infected athletes (3%) demonstrated LGE (one reversible), compared with none of the controls. During the 26.7 (±5.8) months follow-up, all four athletes resumed elite-level sports, without an increase in ventricular arrhythmias or adverse cardiac remodelling. None of the infected athletes reported new cardiac symptoms or events. The majority (n=118; 96%) still participated in elite-level sports; no sports careers were terminated due to SARS-CoV-2. CONCLUSIONS: This prospective study demonstrates the safety of resuming elite-level sports after SARS-CoV-2 infection. The medium-term risks associated with SARS-CoV-2 infection and elite-level sports appear low, as the resumption of elite sports did not lead to detrimental cardiac effects or increases in clinical events, even in the four elite athletes with SARS-CoV-2 associated myocardial involvement.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Feminino , Adulto Jovem , Adulto , Masculino , Estudos Prospectivos , Seguimentos , Meios de Contraste , COVID-19/epidemiologia , Gadolínio , Atletas , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia
19.
JACC Heart Fail ; 12(1): 134-147, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37565978

RESUMO

BACKGROUND: MYH7 variants cause hypertrophic cardiomyopathy (HCM), noncompaction cardiomyopathy (NCCM), and dilated cardiomyopathy (DCM). Screening of relatives of patients with genetic cardiomyopathy is recommended from 10 to 12 years of age onward, irrespective of the affected gene. OBJECTIVES: This study sought to study the penetrance and prognosis of MYH7 variant-associated cardiomyopathies. METHODS: In this multicenter cohort study, penetrance and major cardiomyopathy-related events (MCEs) were assessed in carriers of (likely) pathogenic MYH7 variants by using Kaplan-Meier curves and log-rank tests. Prognostic factors were evaluated using Cox regression with time-dependent coefficients. RESULTS: In total, 581 subjects (30.1% index patients, 48.4% male, median age 37.0 years [IQR: 19.5-50.2 years]) were included. HCM was diagnosed in 226 subjects, NCCM in 70, and DCM in 55. Early penetrance and MCEs (age <12 years) were common among NCCM-associated variant carriers (21.2% and 12.0%, respectively) and DCM-associated variant carriers (15.3% and 10.0%, respectively), compared with HCM-associated variant carriers (2.9% and 2.1%, respectively). Penetrance was significantly increased in carriers of converter region variants (adjusted HR: 1.87; 95% CI: 1.15-3.04; P = 0.012) and at age ≤1 year in NCCM-associated or DCM-associated variant carriers (adjusted HR: 21.17; 95% CI: 4.81-93.20; P < 0.001) and subjects with a family history of early MCEs (adjusted HR: 2.45; 95% CI: 1.09-5.50; P = 0.030). The risk of MCE was increased in subjects with a family history of early MCEs (adjusted HR: 1.82; 95% CI: 1.15-2.87; P = 0.010) and at age ≤5 years in NCCM-associated or DCM-associated variant carriers (adjusted HR: 38.82; 95% CI: 5.16-291.88; P < 0.001). CONCLUSIONS: MYH7 variants can cause cardiomyopathies and MCEs at a young age. Screening at younger ages may be warranted, particularly in carriers of NCCM- or DCM-associated variants and/or with a family history of MCEs at <12 years.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Humanos , Masculino , Adulto , Pré-Escolar , Criança , Feminino , Penetrância , Estudos de Coortes , Cardiomiopatias/genética , Cardiomiopatia Dilatada/genética , Prognóstico , Mutação , Cadeias Pesadas de Miosina/genética , Miosinas Cardíacas/genética
20.
EBioMedicine ; 99: 104937, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38118401

RESUMO

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Assuntos
Desfibriladores Implantáveis , Humanos , Feminino , Masculino , Morte Súbita Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Eletrocardiografia , Redes Neurais de Computação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...