Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 309
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38725252

RESUMO

INTRODUCTION: Reports of comparison with procedural outcomes for implantable cardioverter defibrillator (ICD) and pacemaker (PM) transvenous lead extraction (TLE) are old and limited. We sought to compare the safety, efficacy, and procedural properties of ICD and PM TLE and assess the impact of lead age. METHODS: The study cohort included all consecutive patients with ICD and PM TLE in the Cleveland Clinic Prospective TLE Registry between 2013 and 2022. Extraction success, complications, and failure employed the definitions described in the HRS 2017 TLE guidelines. RESULTS: A total of 885 ICD leads, a median implant duration of 8 (5-11) years in 810 patients, and 1352 PM leads of 7 (3-13) years in 807 patients were included. Procedural success rates in ICD patients were superior to those of PM in >20 years leads but similar in ≤20 years leads. In the PM group, the complete success rate of TLE decreased significantly according to the increase of lead age, but not in the ICD group. ICD TLE required more extraction tools compared with PM TLE but cases with older leads required non-laser sheath extraction tools in both groups. The most common injury site in major complication cases differed between ICD and PM TLE, although major complication rates showed no difference in both groups (2.7% vs. 1.6%, p = .12). CONCLUSION: The procedural success rate by TLE is greater for ICD patients than PM patients with leads >20 years old but requires more extraction tools. Common vascular complication sites and the impact of lead age on procedural outcomes and required tools differed between ICD and PM TLE.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38520434

RESUMO

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.

3.
Clin Infect Dis ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466039

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38466252

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

5.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472038

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Infecções Cardiovasculares , Endocardite , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Consenso , Tomografia Computadorizada por Raios X , Imagem Multimodal , Endocardite/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
6.
Heart Rhythm ; 21(5): e1-e29, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38466251

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Consenso , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Fluordesoxiglucose F18/farmacologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/farmacologia , Leucócitos , Estados Unidos , Infecções Cardiovasculares/diagnóstico , Sociedades Médicas , Imagem Multimodal/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Endocardite/diagnóstico , Endocardite/diagnóstico por imagem
7.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38000893

RESUMO

AIMS: Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS: The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION: Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Criança , Adolescente , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Retrospectivos , Resultado do Tratamento
8.
JAMA Cardiol ; 8(12): 1165-1173, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37851461

RESUMO

Importance: Complete hardware removal is a class I recommendation for cardiovascular implantable electronic device (CIED) infection, but practice patterns and outcomes remain unknown. Objective: To quantify the number of Medicare patients with CIED infections who underwent implantation from 2006 to 2019 and lead extraction from 2007 to 2019 to analyze the outcomes in these patients in a nationwide clinical practice cohort. Design, Setting, and Participants: This cohort study included fee-for-service Medicare Part D beneficiaries from January 1, 2006, to December 31, 2019, who had a de novo CIED implantation and a CIED infection more than 1 year after implantation. Data were analyzed from January 1, 2005, to December 31, 2019. Exposure: A CIED infection, defined as (1) endocarditis or infection of a device implant and (2) documented antibiotic therapy. Main Outcomes and Measures: The primary outcomes of interest were device infection, device extraction, and all-cause mortality. Time-varying multivariable Cox proportional hazards regression models were used to evaluate the association between extraction and survival. Results: Among 1 065 549 patients (median age, 78.0 years [IQR, 72.0-84.0 years]; 50.9% male), mean (SD) follow-up was 4.6 (2.9) years after implantation. There were 11 304 patients (1.1%) with CIED infection (median age, 75.0 years [IQR, 67.0-82.0 years]); 60.1% were male, and 7724 (68.3%) had diabetes. A total of 2102 patients with CIED infection (18.6%) underwent extraction within 30 days of diagnosis. Infection occurred a mean (SD) of 3.7 (2.4) years after implantation, and 1-year survival was 68.3%. There was evidence of highly selective treatment, as most patients did not have extraction within 30 days of diagnosed infection (9202 [81.4%]), while 1511 (13.4%) had extraction within 6 days of diagnosis and 591 (5.2%) had extraction between days 7 and 30. Any extraction was associated with lower mortality compared with no extraction (adjusted hazard ratio [AHR], 0.82; 95% CI, 0.74-0.90; P < .001). Extraction within 6 days was associated with even lower risk of mortality (AHR, 0.69; 95% CI, 0.61-0.78; P < .001). Conclusions and Relevance: In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction. The findings suggest a need to improve adherence to guideline-directed care among patients with CIED infection.


Assuntos
Desfibriladores Implantáveis , Endocardite , Humanos , Masculino , Idoso , Estados Unidos/epidemiologia , Feminino , Desfibriladores Implantáveis/efeitos adversos , Estudos de Coortes , Medicare , Fatores de Risco
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37552791

RESUMO

AIMS: Heart rate score (HRSc), the per cent of atrial paced and sensed event in the largest 10 b.p.m. rate histogram bin of a pacemaker, predicts survival in patients with cardiac devices. No correlation between HRSc and development of atrial fibrillation (AF) has been reported. In this study, we evaluated the relationship between pacemaker post-implantation HRSc and the incidence of newly developed atrial tachyarrhythmias (ATAs). METHODS AND RESULTS: Patients with dual-chamber pacemakers, implanted 2013-17, with the LATITUDE remote monitoring data with ≥600 000 beats of histogram data collected at baseline were included (N = 34 543). Heart rate score was determined from the initial 3-month post-implantation histogram data. Patients were excluded if they had ATAs, defined as atrial high-rate episodes >5 min or >1% of right atrial beats >170 b.p.m. during the initial 3 months post-implantation. New ATAs, after the baseline period, were defined by each of the following: >1, >10, or >25% of atrial beats >170 b.p.m. or atrial tachycardia response (ATR) events >24 h. Patients were followed a median of 2.8 (1.0-4.0) years. The incidence of ATAs increased in proportion to HRSc (log-rank P-value <0.001), and the initial HRSc ≥70% was associated with increased ATAs by all definitions. Patients with initial HRSc ≥70% were older, had a higher percentage of right atrium pacing (%RA pacing), had a lower percentage of right ventricular pacing (%RV pacing), and were more likely programmed with rate-response vs. subjects with HRSc <70%. Initial HRSc (hazard ratio: 1.07, 95% confidence interval: 1.05-1.09; P < 0.0001) independently predicted ATAs after adjusting for age, gender, %RV pacing, and rate-response programming. The %RA pacing and initial HRSc were correlated. CONCLUSION: Heart rate score independently predicts any subsequent duration of ATAs in pacemaker patients.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Frequência Cardíaca/fisiologia , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Átrios do Coração , Taquicardia/diagnóstico , Taquicardia/epidemiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos
11.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37634520

RESUMO

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estudos Prospectivos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , Eletrocardiografia
15.
JACC Asia ; 3(3): 321-334, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37323870

RESUMO

In a contemporary setting, where the risk of sudden cardiac death (SCD) is low, heart failure management is improved, and technology is advanced, identifying the patients who would benefit the most from an implantable cardioverter-defibrillator (ICD) treatment for primary prevention remains a challenge. The prevalence of SCD is lower in Asia when compared with the United States/Europe (35-45 per 100,000 person-years vs 55-100 per 100,000 person-years, respectively). Nevertheless, this should not explain the enormous gap in ICD's utilization among eligible candidates (∼12% in Asia vs ∼45% in the United States/Europe). The disparity between Asia and Western countries, together with significant variation among the Asian population and the previously mentioned challenges, requires an individualized approach and specific regional recommendation, especially in countries with limited resources where ICDs are being extremely underutilized This review focuses on the current knowledge of ICD therapy for SCD prevention and how to improve patient and device selection.

18.
Heart Rhythm ; 20(6): 902-909, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36868544

RESUMO

BACKGROUND: With the advent of conduction system pacing, use of the Medtronic SelectSecure Model 3830 lead has increased substantially. However, with this increased use, the potential need for lead extraction also will increase. Lumenless lead construction requires an understanding of both applicable tensile forces as well as lead preparation techniques that can influence consistent extraction. OBJECTIVE: The purpose of this study was to use bench testing methodologies to characterize the physical properties of lumenless leads and to describe related lead preparation methods that support known extraction techniques. METHODS: Multiple 3830 lead preparation techniques, commonly used in extraction practices, were compared on the bench to assess rail strength (RS) in simple traction and use conditions with simulated scar. Retention of the IS1 connector vs severing the lead body preparation techniques were compared. Distal snare and rotational extraction tools were evaluated. RESULTS: The retained connector method provided higher RS compared to the modified cut lead method: mean 11.42 lbf (9.85-12.73 lbf) vs 8.51 lbf (1.66-14.32 lbf), respectively. Snare use distally did not significantly affect RS: mean 11.05 lbf (8.58-13.95 lbf). Lead damage occurred with the TightRail extraction tool at angles ≥90°, which could occur with right-sided implants. CONCLUSIONS: When extracting SelectSecure leads, the retained connector method to maintain cable engagement benefits preservation of the extraction RS. Limiting traction force to <10 lbf (4.5 kgf) and avoiding poor lead preparation methods are critical to consistent extraction. Femoral snaring does not change RS when needed and offers a method to regain lead rail in cases of distal cable fracture.


Assuntos
Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Implantação de Prótese/métodos , Doença do Sistema de Condução Cardíaco , Eletrodos Implantados
19.
Heart Rhythm ; 20(6): 872-878, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36933853

RESUMO

BACKGROUND: Reports of coronary sinus (CS) lead removal include small studies with short implant durations. Procedural outcomes for mature CS leads removed with long duration implantation are unavailable. OBJECTIVE: The purpose of this study was to examine the safety, efficacy, and clinical predictors of incomplete CS lead removal by transvenous lead extraction (TLE) in a large long implant duration cardiac resynchronization therapy patient cohort. METHODS: Consecutive patients with cardiac resynchronization therapy devices in the Cleveland Clinic Prospective TLE Registry who had TLE between 2013 and 2022 were included in the analysis. RESULTS: CS leads (N = 231; implant duration 6.1 ± 4.0 years) removed from 226 patients were included, using powered sheaths for 137 leads (59.3%). Complete CS lead extraction success was achieved in 95.2% of leads (n = 220) and in 95.6% of patients (n = 216). Major complications occurred in 5 patients (2.2%). Patients who had the CS lead extracted first had significantly higher incomplete removal rates than when the other leads were first removed. Multivariable analysis showed that older CS lead age (odds ratio 1.35; 95% confidence interval 1.01-1.82; P = .03) and removal of the first CS lead (odds ratio 7.48; 95% confidence interval 1.02-54.95; P = .045) were independent predictors of incomplete CS lead removal. CONCLUSION: The complete and safe lead removal rate of long implant duration CS leads by TLE was 95%. However, CS lead age and the order in which leads were extracted were the independent predictors of incomplete CS lead removal. Therefore, before the CS lead is extracted, physicians should first extract the leads from the other chambers and use powered sheaths.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , Seio Coronário/cirurgia , Remoção de Dispositivo/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...