1.
J Appl Clin Med Phys ; 22(11): 185-195, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34697869

RESUMO

PURPOSE: Research productivity metrics are important for decisions regarding hiring, retention, and promotion in academic medicine, and these metrics can vary widely among different disciplines. This article examines productivity metrics for radiation therapy physicists (RTP) in the United States. METHODS AND MATERIALS: Database searches were performed for RTP faculty at US institutions that have RTP residencies accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP). Demographics, academic rank, number of publications, academic career length, Hirsch index (h-index), m-quotient, and history of National Institutes of Health (NIH) funding as a principal investigator (PI) were collected for each RTP. Logistic regression was performed to determine the probability of academic rank as a function of h-index and m-quotient. Statistical tests used included the Wilcoxon ranked sum test and the Pearson χ2 test. RESULTS: A total of 1038 faculty and staff were identified at 78 institutions with CAMPEP-accredited residencies. The average RTP academic career duration is 13.5 years, with 46.7 total publications, h-index of 10.7, and m-quotient of 0.66. Additionally, 10.5% of RTP have a history of NIH funding as a PI. Large disparities were found in academic productivity of doctoral-prepared physicists compared to those with a terminal master's degree. For differences in junior and senior faculty, statistical tests yielded significance in career duration, number of publications, h-index, and m-quotient. Gender disparities were identified in the overall distribution of RTP consistent with the membership of the American Association of Physicists in Medicine. Further gender disparities were found in the number of doctoral-prepared RTP and physicists in senior faculty roles. CONCLUSIONS: This manuscript provides objective benchmark data regarding research productivity of academic RTP. These data may be of interest to faculty preparing for promotion, and also to institutional leadership.


Assuntos
Pesquisa Biomédica , Internato e Residência , Eficiência , Docentes , Humanos , National Institutes of Health (U.S.) , Física , Estados Unidos
2.
J Radiosurg SBRT ; 7(2): 149-156, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33282468

RESUMO

Commercial systems such as Varian HyperArcTM and BrainLab Elements MultiMetTM have been developed that allow radiosurgery treatment of multiple brain metastases using a single isocenter. Each software package places increased demands on frameless immobilization and requires the use of a specific immobilization system: the QFix-Encompass system for Varian and the BrainLab frameless-mask system for BrainLab. At our institution, patients receiving traditional radiosurgery (one isocenter per target lesion) were treated using both immobilization systems. Intrafraction motion was determined for each patient using multiple cone-beam CT scans and the same image-registration software during treatment. There were no statistically-significant differences in mean absolute translational shifts between the two mask systems, with a mean 3D-vector motion of approximately 0.43 mm for both systems. There were also no statistically-significant differences in the mean absolute rotational shifts between the two mask systems. Although the average residual errors were insignificant between the mask systems, special attention should be paid to individual maximum shifts with both systems. Large maximum rotational misalignments could present significant misalignment of lesions as distance increases from the isocenter. Finally, large maximum shifts highlight the need for real-time monitoring of patient movement during radiosurgery of multiple lesions using a single isocenter.

3.
J Appl Clin Med Phys ; 21(12): 178-187, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33226709

RESUMO

PURPOSE: Real-time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions. METHODS: Percent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter). RESULTS: The PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter. CONCLUSION: During MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real-time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real-time target tracking during MRgRT.


Assuntos
Aceleradores de Partículas , Radioterapia de Intensidade Modulada , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Controle de Qualidade
4.
Pract Radiat Oncol ; 10(5): e425-e431, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32004703

RESUMO

PURPOSE: Treating critically ill patients in radiation oncology departments poses multiple safety risks. This study describes a method to improve the speed of radiation treatment for patients in the intensive care unit by eliminating the need for computed tomography (CT) simulation or on-table treatment planning using patients' previously acquired diagnostic CT scans. METHODS AND MATERIALS: Initially, a retrospective planning study was performed to assess the applicability and safety of diagnostic scan-based planning (DSBP) for 3 typical indications for radiation therapy in patients in the intensive care unit: heterotopic ossification (10), spine metastases (cord compression; 10), and obstructive lung lesions (5). After identification of an appropriate diagnostic CT scan, treatment planning was performed using the diagnostic scan data set. These treatment plans were then transferred to the patients' simulation scans, and a dosimetric comparison was performed between the 2 sets of plans. Additionally, a time study of the first 10 patients treated with DSBP in our department was performed. RESULTS: The retrospective analysis demonstrated that DSBP resulted in treatment plans that, when transferred to the CT simulation data sets, provided excellent target coverage, a median D95% of 96% (range, 86%-100%) of the prescription dose with acceptable hot spots, and a median Dmax108% (range, 102%-113%). Subsequently, DSBP has been used for 10 critically ill patients. The patients were treated without CT simulation, and the median time between patient check-in to the department and completion of radiation therapy was 28 minutes (range, 18-47 minutes.) CONCLUSIONS: This study demonstrates that it is possible to safely use DSBP for the treatment of critically ill patients. This method has the potential to simplify the treatment process and improve the speed and safety of treatment.


Assuntos
Estado Terminal , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
J Appl Clin Med Phys ; 19(3): 149-158, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29682879

RESUMO

PURPOSE: To describe the commissioning of AIRO mobile CT system (AIRO) for adaptive proton therapy on a compact double scattering proton therapy system. METHODS: A Gammex phantom was scanned with varying plug patterns, table heights, and mAs on a CT simulator (CT Sim) and on the AIRO. AIRO-specific CT-stopping power ratio (SPR) curves were created with a commonly used stoichiometric method using the Gammex phantom. A RANDO anthropomorphic thorax, pelvis, and head phantom, and a CIRS thorax and head phantom were scanned on the CT Sim and AIRO. Clinically realistic treatment plans and nonclinical plans were generated on the CT Sim images and subsequently copied onto the AIRO CT scans for dose recalculation and comparison for various AIRO SPR curves. Gamma analysis was used to evaluate dosimetric deviation between both plans. RESULTS: AIRO CT values skewed toward solid water when plugs were scanned surrounded by other plugs in phantom. Low-density materials demonstrated largest differences. Dose calculated on AIRO CT scans with stoichiometric-based SPR curves produced over-ranged proton beams when large volumes of low-density material were in the path of the beam. To create equivalent dose distributions on both data sets, the AIRO SPR curve's low-density data points were iteratively adjusted to yield better proton beam range agreement based on isodose lines. Comparison of the stoichiometric-based AIRO SPR curve and the "dose-adjusted" SPR curve showed slight improvement on gamma analysis between the treatment plan and the AIRO plan for single-field plans at the 1%, 1 mm level, but did not affect clinical plans indicating that HU number differences between the CT Sim and AIRO did not affect dose calculations for robust clinical beam arrangements. CONCLUSION: Based on this study, we believe the AIRO can be used offline for adaptive proton therapy on a compact double scattering proton therapy system.


Assuntos
Algoritmos , Cabeça/diagnóstico por imagem , Imagens de Fantasmas , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
7.
Adv Radiat Oncol ; 2(3): 494-502, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29114618

RESUMO

PURPOSE: To characterize the accuracy of noncoplanar image guided radiation therapy with the Varian Edge radiosurgery system for intracranial stereotactic radiosurgery (SRS) treatments by assessing the accuracy of kV/kV orthogonal pair registration with Optical Surface Monitoring System (OSMS) monitoring relative to cone beam computed tomography (CT). METHODS AND MATERIALS: A Computerized Imaging Reference System head phantom and Encompass SRS Immobilization System were used to determine collision-free space for orthogonal image pairs (kV/kV) for couch rotations (CRs) of 45°, 30°, 15°, 345°, 330°, and 315°. Couch-induced shifts were measured using kV/kV orthogonal image pairs, OSMS, and cone beam CT. The kV/kV image pairs and OSMS localization accuracy was also assessed with respect to cone beam CT. RESULTS: Mean orthogonal image pair differences for 315°, 330°, 345°, 15°, 30°, and 45° CRs were ≤±0.60 mm and ±0.37°. OSMS localization accuracy was ≤±0.25 mm and ±0.20°. Correspondingly, kV/kV localization accuracy was ≤±0.30 mm and ±0.5°. Shift differences for various image pairs at all CRs were ≤±1.10 mm and ±0.7°. Cone beam CT deviation was 0.10 mm and 0.00° without patient motion or CR. CONCLUSION: Based on our study, CR-induced shifts with the Varian Edge radiosurgery system will not produce noticeable dosimetric effects for SRS treatments. Thus, replacing cone beam CT with orthogonal kV/kV pairs coupled with OSMS at the treatment couch angle could reduce the number of cone beam CT scans that are acquired during a standard SRS treatment while providing an accurate and safe treatment with negligible dosimetric effects on the treatment plan.

8.
J Appl Clin Med Phys ; 18(3): 130-136, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28436155

RESUMO

PURPOSE: The purpose of this study was to characterize the Mobius AIRO Mobile CT System for localization and image-guided proton therapy. This is the first known application of the AIRO for proton therapy. METHODS: Five CT images of a Catphan® 504 phantom were acquired on the AIRO Mobile CT System, Varian EDGE radiosurgery system cone beam CT (CBCT), Philips Brilliance Big Bore 16 slice CT simulator, and Siemens SOMATOM Definition AS 20 slice CT simulator. DoseLAB software v.6.6 was utilized for image quality analysis. Modulation transfer function, scaling discrepancy, geometric distortion, spatial resolution, overall uniformity, minimum uniformity, contrast, high CNR, and maximum HU deviation were acquired. Low CNR was acquired manually using the CTP515 module. Localization accuracy and CT Dose Index were measured and compared to reported values on each imaging device. For treatment delivery systems (Edge and Mevion), the localization accuracy of the 3D imaging systems were compared to 2D imaging systems on each system. RESULTS: The AIRO spatial resolution was 0.21 lp mm-1 compared with 0.40 lp mm-1 for the Philips CT Simulator, 0.37 lp mm-1 for the Edge CBCT, and 0.35 lp mm-1 for the Siemens CT Simulator. AIRO/Siemens and AIRO/Philips differences exceeded 100% for scaling discrepancy (191.2% and 145.8%). The AIRO exhibited higher dose (>27 mGy) than the Philips CT Simulator. Localization accuracy (based on the MIMI phantom) was 0.6° and 0.5 mm. Localization accuracy (based on Stereophan) demonstrated maximum AIRO-kV/kV shift differences of 0.1 mm in the x-direction, 0.1 mm in the y-direction, and 0.2 mm in the z-direction. CONCLUSIONS: The localization accuracy of AIRO was determined to be within 0.6° and 0.5 mm despite its slightly lower image quality overall compared to other CT imaging systems at our institution. Based on our study, the Mobile AIRO CT system can be utilized accurately and reliably for image-guided proton therapy.


Assuntos
Terapia com Prótons/instrumentação , Radiocirurgia/instrumentação , Radioterapia Guiada por Imagem/instrumentação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Feixe Cônico , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos
9.
Int J Radiat Oncol Biol Phys ; 86(3): 477-83, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23523325

RESUMO

PURPOSE: To describe the first use of the commercially available Calypso 4D Localization System in the lung. METHODS AND MATERIALS: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R(2)) were tabulated for all 42 tracks. RESULTS: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. CONCLUSIONS: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.


Assuntos
Campos Eletromagnéticos , Marcadores Fiduciais , Neoplasias Pulmonares , Pulmão , Movimento , Robótica/métodos , Broncoscopia , Marcadores Fiduciais/efeitos adversos , Humanos , Implantes Experimentais , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Pneumotórax/etiologia , Próteses e Implantes , Radiografia
10.
Prostate Cancer ; 2012: 130579, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22111005

RESUMO

The purpose of this work is to determine appropriate radiation therapy beam margins to account for intrafraction prostate translations for use with real-time electromagnetic position monitoring and correction strategies. Motion was measured continuously in 35 patients over 1157 fractions at 5 institutions. This data was studied using van Herk's formula of (αΣ + γσ') for situations ranging from no electromagnetic guidance to automated real-time corrections. Without electromagnetic guidance, margins of over 10 mm are necessary to ensure 95% dosimetric coverage while automated electromagnetic guidance allows the margins necessary for intrafraction translations to be reduced to submillimeter levels. Factors such as prostate deformation and rotation, which are not included in this analysis, will become the dominant concerns as margins are reduced. Continuous electromagnetic monitoring and automated correction have the potential to reduce prostate margins to 2-3 mm, while ensuring that a higher percentage of patients (99% versus 90%) receive a greater percentage (99% versus 95%) of the prescription dose.

11.
J Appl Clin Med Phys ; 12(4): 3590, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22089017

RESUMO

In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery.


Assuntos
Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Fenômenos Eletromagnéticos , Humanos
12.
Radiother Oncol ; 99(1): 37-43, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21458092

RESUMO

PURPOSE: To evaluate differences in target motion during prostate irradiation in the prone versus supine position using electromagnetic tracking to measure prostate mobility. MATERIALS/METHODS: Twenty patients received prostate radiotherapy in the supine position utilizing the Calypso Localization System® for prostate positioning and monitoring. For each patient, 10 treatment fractions were followed by a session in which the patient was repositioned prone, and prostate mobility was tracked. The fraction of time that the prostate was displaced by >3, 5, 7, and 10mm was calculated for each patient, for both positions (400 tracking sessions). RESULTS: Clear patterns of respiratory motion were seen in the prone tracks due to the influence of increased abdominal motion. Averaged over all patients, the prostate was displaced >3 and 5mm for 37.8% and 10.1% of the total tracking time in the prone position, respectively. In the supine position, the prostate was displaced >3 and 5mm for 12.6% and 2.9%, respectively. With both patient setups, inferior and posterior drifts of the prostate position were observed. Averaged over all prone tracking sessions, the prostate was displaced >3mm in the posterior and inferior directions for 11.7% and 9.5% of the total time, respectively. CONCLUSIONS: With real-time tracking of the prostate, it is possible to study the effects of different setup positions on the prostate mobility. The percentage of time the prostate moved >3 and 5mm was increased by a factor of three in the prone versus supine position. For larger displacements (>7 mm) no difference in prostate mobility was observed between prone and supine positions. To reduce rectal toxicity, radiotherapy in the prone position may be a suitable alternative provided respiratory motion is accounted for during treatment. Acute and late toxicity results remain to be evaluated for both patient positions.


Assuntos
Movimento (Física) , Neoplasias da Próstata/radioterapia , Fracionamento da Dose de Radiação , Fenômenos Eletromagnéticos , Humanos , Imageamento Tridimensional , Masculino , Decúbito Ventral , Dosagem Radioterapêutica , Respiração , Decúbito Dorsal
13.
J Radiosurg SBRT ; 1(1): 21-29, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-29296294

RESUMO

Radiosurgery first became a clinical option in the 1960's because of the Gamma Knife, and the technology proliferated in the 1980's due to the availability of linear accelerator radiosurgery. The technology has continued to develop with both Gamma Knife and linac radiosurgery due primarily to advances in computer technology and robotic automation. Many of these advances include planning systems that enhance the conformity of the dose distribution, and delivery systems that can more safely and efficiently delivery these more complex treatment plans. This manuscript details the evolution of technologies in stereotactic localization and delivery for intracranial radiosurgery.

14.
J Appl Clin Med Phys ; 11(1): 2924, 2010 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-20160686

RESUMO

The aim of this study is to compare two methodologies of prostate localization in a large cohort of patients. Daily prostate localization using B-mode ultrasound has been performed at the Nebraska Medical Center since 2000. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso(R)). With each technology, patients were localized initially using skin marks. Localization error distributions were determined from offsets between the initial setup positions and those determined by ultrasound or Calypso. Ultrasound localization data was summarized from 16619 imaging sessions spanning 7 years; Calypso localization data consists of 1524 fractions in 41 prostate patients treated in the course of a clinical trial at five institutions and 640 localizations from the first 16 patients treated with our clinical system. Ultrasound and Calypso patients treated between March and September 2007 at the Nebraska Medical Center were analyzed and compared, allowing a single institutional comparison of the two technologies. In this group of patients, the isocenter determined by ultrasound-based localization is on average 5.3 mm posterior to that determined by Calypso, while the systematic and random errors and PTV margins calculated from the ultrasound localizations were 3 - 4 times smaller than those calculated from the Calypso localizations. Our study finds that there are systematic differences between Calypso and ultrasound for prostate localization.


Assuntos
Fenômenos Eletromagnéticos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Ultrassonografia , Abdome , Humanos , Funções Verossimilhança , Masculino , Movimento , Nebraska , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Próteses e Implantes , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Pele , Fatores de Tempo
15.
J Appl Clin Med Phys ; 12(1): 3311, 2010 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-21330977

RESUMO

We report on our initial experience with daily image guidance for the treatment of a patient with a basal cell carcinoma of the nasal dorsum using bolus electron conformal therapy. We describe our approach to daily alignment using treatment machine-integrated megavoltage (MV) planar imaging in conjunction with cone beam CT (CBCT) volumetric imaging to ensure the best possible setup reproducibility. Based on MV imaging, beam aperture misalignment with the intended treatment region was as large as 0.5 cm in the coronal plane. Four of the five fractions analyzed show induced shifts when compared to digitally reconstructed radiographs (DRR), in the range of 0.2-0.5 cm. Daily inspection of CBCT images show that the bolus device can have significant tilt in any given direction by as much as 13° with respect to beam axis. In addition, we show that CBCT images reveal air gaps between bolus and skin that vary from day to day, and can potentially degrade surface dose coverage. Retrospective dose calculation on CBCT image sets shows that when daily shifts based on MV imaging are not corrected, geometrical miss of the planning target volume (PTV) can cause an underdosing as large as 14% based on DVH analysis of the dose to the 90% of the PTV volume.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Nasais/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Elétrons/uso terapêutico , Humanos , Dosagem Radioterapêutica
16.
Phys Med Biol ; 54(20): 6165-80, 2009 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-19794245

RESUMO

Lung tumors move during breathing depending on the patient's patho-physiological condition and orientation, thereby compromising the accurate deposition of the radiation dose during radiotherapy. In this paper, we present and validate a computer-based simulation framework to calculate the delivered dose to a 3D moving tumor and its surrounding normal tissues. The computer-based simulation framework models a 3D volumetric lung tumor and its surrounding tissues, simulates the tumor motion during a simulated dose delivery both as a self-reproducible motion and a random motion using the dose extracted from a treatment plan, and predicts the amount and location of radiation doses deposited. A radiation treatment plan of a small lung tumor (1-3 cm diameter) was developed in a commercial planning system (iPlan software, BrainLab, Munich, Germany) to simulate the radiation dose delivered. The dose for each radiation field was extracted from the software. The tumor motion was simulated for varying values of its rate, amplitude and direction within a single breath as well as from one breath to another. Such variations represent the variations in tumor motion induced by breathing variations. During the simulation of dose delivery, the dose on the target was summed to generate the real-time dose to the tumor for each beam independently. The simulation results show that the dose accumulated on the tumor varies significantly with both the tumor size and the tumor's motion rate, amplitude and direction. For a given tumor motion rate, amplitude and direction, the smaller the tumor size the smaller is the percentage of the radiation dose accumulated. The simulation results are validated by comparing the center plane of the 3D tumor with 2D film dosimetry measurements using a programmable 4D motion phantom moving in a self-reproducible pattern. The results also show the real-time capability of the framework at 40 discrete tumor motion steps per breath, which is higher than the number of four-dimensional computed tomography (CT) steps (approximately 20) during a single breath. The real-time capability enables the framework to be coupled with real-time tumor monitoring systems such as implanted fiducials for computing the dose delivered in real time during the treatment.


Assuntos
Neoplasias Pulmonares/radioterapia , Radiometria/métodos , Radioterapia Conformacional/métodos , Simulação por Computador , Desenho de Equipamento , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Modelos Teóricos , Radioterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Respiração , Software
17.
Med Phys ; 36(8): 3477-86, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19746781

RESUMO

The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.


Assuntos
Fenômenos Eletromagnéticos , Radioterapia/instrumentação , Radioterapia/normas , Segurança de Equipamentos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Movimento (Física) , Controle de Qualidade , Reprodutibilidade dos Testes
18.
Technol Cancer Res Treat ; 8(2): 123-30, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19334793

RESUMO

Initial results of megavoltage computed tomography (MVCT) brachytherapy treatment planning are presented, using a commercially available helical tomotherapy treatment unit and standard low dose rate (LDR) brachytherapy applicators used for treatment of cervical carcinoma. The accuracy of MVCT imaging techniques, and dosimetric accuracy of the CT based plans were tested with in-house and commercially-available phantoms. Three dimensional (3D) dose distributions were computed and compared to the two dimensional (2D) dosimetry results. Minimal doses received by the 2 cm3 of bladder and rectum receiving the highest doses (D(B2cc) and D(R2cc), respectively) were computed from dose-volume histograms and compared to the doses computed for the standard ICRU bladder and rectal reference dose points. Phantom test objects in MVCT image sets were localized with sub-millimetric accuracy, and the accuracy of the MVCT-based dose calculation was verified. Fifteen brachytherapy insertions were also analyzed. The ICRU rectal point dose did not differ significantly from D(R2cc) (p=0.749, mean difference was 24 cGy +/- 283 cGy). The ICRU bladder point dose was significantly lower than the D(B2cc) (p=0.024, mean difference was 291 cGy +/- 444 cGy). The median volumes of bladder and rectum receiving at least the corresponding ICRU reference point dose were 6.1 cm(3) and 2.0 cm(3), respectively. Our initial experience in using MVCT imaging for clinical LDR gynecological brachytherapy indicates that the MVCT images are of sufficient quality for use in 3D, MVCT-based dose planning.


Assuntos
Braquiterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reto/efeitos da radiação , Bexiga Urinária/efeitos da radiação
19.
Int J Radiat Oncol Biol Phys ; 74(4): 1134-42, 2009 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-19231105

RESUMO

PURPOSE: To assess the dosimetric consequence of intrafraction prostate motion on helical tomotherapy plans. METHODS AND MATERIALS: An electromagnetic tracking device was used to measure real-time prostate motion for 515 fractions (16 patients). Motion tracks were used to retrospectively recalculate dose distributions using a four-dimensional calculation engine. The minimum dose (D(min)), maximum dose (D(max)), and dose to 95% of the volume (D(95%)) were calculated for target volumes and compared with respective values from the treatment plan. The dosimetric effect was evaluated for each fraction. For each patient, the running cumulative effect was assessed throughout the course of treatment. Calculations were repeated assuming a time delay between initial patient setup and start of treatment. RESULTS: Averaged over all fractions, the mean change in target D(95%) was <1% (SD, 3-4%). Reductions in target D(95%) of up to 20% were seen in individual fractions. Changes in prostate D(95%) were similar in frequency and magnitude to D(95%) changes in the planning target volume. The cumulative effect on target D(95%) was approximately 1% (SD, 1%). The average cumulative effect after five fractions was 1% (SD, 1.5%). CONCLUSIONS: In general, the dosimetric effect of observed prostate motion on target D(95%)was small. Infrequently severe D(95%) degradations were observed for individual fractions, but their effect on the cumulative dose distribution was quickly reduced with minimal fractionation.


Assuntos
Movimento , Próstata , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional , Fracionamento da Dose de Radiação , Campos Eletromagnéticos , Humanos , Masculino , Modelos Estatísticos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Próteses e Implantes , Radiografia , Reto/diagnóstico por imagem , Glândulas Seminais , Bexiga Urinária/diagnóstico por imagem
20.
Phys Med Biol ; 53(24): 7073-86, 2008 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-19015580

RESUMO

The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D95% (minimum dose to 95% of the volume) changes in the prostate were well correlated with D95% changes in the PTV. This means that the dosimetric impact of intrafraction motion is not restricted to the periphery of the target. The amount of motion was not well correlated with the dosimetric impact (measured in target D95% changes) of motion. The relationship between motion and its dosimetric impact is complex and depends on the timing and direction of the movement. These findings have implications for motion management techniques. It appears that the use of target margins is not an effective strategy to protect the prostate from the effects of observed intrafraction motion. The complex relationship between motion and its dosimetric effect renders simple threshold-based intervention schemes inefficient. Monitoring of actual prostate motion would allow the documentation of the dosimetric impact and implementation of corrective action if needed. However, when motion management techniques are evaluated, it should be kept in mind that the dosimetric impact of observed prostate motion is small for the majority of fractions.


Assuntos
Neoplasias da Próstata/radioterapia , Radiometria/métodos , Radioterapia de Intensidade Modulada/instrumentação , Relação Dose-Resposta à Radiação , Humanos , Masculino , Modelos Teóricos , Movimento (Física) , Movimento , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Fatores de Tempo