Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37067822

RESUMO

AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Fontes de Energia Elétrica , Coração
2.
Heart Rhythm O2 ; 3(3): 288-294, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734291

RESUMO

Background: Catheter ablation for atrial fibrillation (AF) or left atrial tachycardia is well established. To avoid body movement and pain, sedative and analgesic agents are used. Objective: The aim was to investigate safety of sedation/anti-pain protocol administered by electrophysiology (EP) staff. Methods: A total of 3211 consecutive patients (61% male) undergoing left atrial ablation for paroxysmal AF (37.1%), persistent AF (35.3%) or left atrial tachycardia (27.6%) were included. Midazolam, fentanyl, and propofol were administered by EP staff. In case of respiratory depression, endotracheal intubation (eIT) or noninvasive ventilation (NIV) was implemented. Risk factors for eIT or NIV were analyzed. Results: Mean doses of propofol, midazolam, and fentanyl were 33.7 ± 16.7 mg, 3 ± 11.1 mg, and 0.16 ± 2.2 mg, respectively. Norepinephrine was administered in 396 of 3211 patients (12.3%) because of blood pressure drop (mean arterial pressure <60 mm Hg). NIV was necessary in 47 patients (1.5%) and eIT in 1 patient (0.03%). Procedure duration, high body mass index (BMI), high CHADS2-VASC2 score, high age, low glomerular filtration rate, diabetes mellitus, and low baseline oxygen saturation were associated with NIV or eIT. The only independent predictor for NIV/eIT was high BMI (>30.1 ± 9.0 kg/m2). Therefore, patients with a BMI of ≥30 had a 40% higher risk for the need of NIV/eIT during the procedure in our study. Conclusion: Sedation/anti-pain control including midazolam, propofol, and fentanyl administered by EP staff is safe, with only 1.53% requirement of NIV/eIT. High BMI (>30 kg/m2) emerged as an independent predictor for eIT/NIV.

3.
Clin Res Cardiol ; 111(1): 85-95, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34519875

RESUMO

BACKGROUND: Early recurrence of atrial tachyarrhythmia (ERAT) is common after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF), but its clinical significance in patients with persistent AF remains unclear. We sought to determine the predictive value of ERAT for rhythm outcome after RFCA for persistent AF. METHODS: The study included 207 consecutive patients (mean age 66.4 ± 10.7 years, male 66.2%) with persistent and long-standing persistent AF undergoing de novo pulmonary vein isolation (± atrial substrate ablation). All patients remained off antiarrhythmic drugs. ERAT was defined as any atrial arrhythmia ≥ 30 s occurring within the first 30 days. Late recurrence (LR) was determined during follow-up visits scheduled 1, 3, 6 and 12 months post-ablation using 7-day Holter ECGs. RESULTS: ERAT occurred in 143/207 (69.1%) patients as AF (60%) or atrial tachycardia (40%) and was persistent in 82% of cases. During a median follow-up of 22.2 months, LR occurred significantly more often in patients with ERAT than in patients without ERAT (92.3 vs. 43.8%, P < 0.001). The only independent predictors for LR were ERAT (OR 16.8, 95% CI 6.184-45.797, P < 0.001) and intraprocedural termination to sinus rhythm (OR 0.052, 95% CI 0.003-0.851, P = 0.038). Extending the blanking period from 30 to 90 days did not impact LR rates. CONCLUSION: ERAT following ablation of persistent AF is strongly associated with late arrhythmia recurrence, which challenges the assumption that ERAT represents merely a transient phenomenon. While limiting the blanking period to 30 days seems justified, the benefit of early re-ablations remains to be addressed in future studies.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...