Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 94(7): 3091-3102, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35144383

RESUMO

Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that is capable of simultaneous measurement of the size and number concentration of metal-containing nanoparticles (NPs) at environmentally relevant levels. Although spICP-MS is widely applied to different fields, challenges remain in obtaining accurate and consistent particle number concentration (PNC) measurements. This paper presents, for the first time, a rigorous assessment of spICP-MS capabilities for measuring the PNC of gold NP (AuNP) suspensions of different sizes and coatings. The calibration of spICP-MS was accomplished with the National Institute of Standards and Technology (NIST) AuNP reference material (RM) 8013. The comparability of both spICP-MS direct and derived determination of PNC and reference PNC derived based on the mean particle size or the particle size distribution obtained by different reference sizing techniques was first assessed for NIST AuNP RM 8012, nominal diameter 30 nm. To enable a proper assessment of the accuracy of the spICP-MS results, a comprehensive estimation of the expanded uncertainty for PNC determination was carried out. Regardless of NP size or coating, a good agreement (90-110%) between spICP-MS direct determination of PNC and reported PNCs was obtained for all of the suspensions studied only when reliable in-house Au mass fractions and thorough mean particle size determinations were included in the calculation of the derived PNCs. The use of the particle size distribution over the mean size to derive PNCs resulted in larger differences for materials with a low contribution (<2%) of smaller NPs (30 nm), materials with a higher polydispersity (100 nm), or materials with two distinct subpopulations of particles (60 nm), regardless of NP coating.


Assuntos
Ouro , Nanopartículas Metálicas , Ouro/química , Espectrometria de Massas/métodos , Nanopartículas Metálicas/química , Tamanho da Partícula , Análise Espectral
2.
Anal Chem ; 90(24): 14376-14386, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30472826

RESUMO

Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique capable of simultaneously measuring nanoparticle size and number concentration of metal-containing nanoparticles (NPs) at environmental levels. single particle ICP-MS will become an established measurement method once the metrological quality of the measurement results it produces have been proven incontrovertibly. This Article presents the first validation of spICP-MS capabilities for measuring mean NP size and number size distribution of gold nanoparticles (AuNPs). The validation is achieved by (i) calibration based on the consensus value for particle size derived from six different sizing techniques applied to National Institute of Standards and Technology (NIST) Reference Material (RM) 8013; (ii) comparison with high-resolution scanning electron microscopy (HR-SEM) used as a reference method, which is linked to the International System of Units (SI) through a calibration standard characterized by the NIST metrological atomic force microscope; and (iii) evaluation of the uncertainty associated with the measurement of the mean particle size to enable comparison of the spICP-MS and HR-SEM methods. After establishing HR-SEM and spICP-MS measurement protocols, both methods were used to characterize commercial AuNP suspensions of three different sizes (30, 60, and 100 nm) with four different coatings and surface charge at pH 7. Single particle ICP-MS measurements (corroborated by HR-SEM) revealed the existence of two distinct subpopulations of particles in the number size distributions for four of the 60 nm commercial suspensions, a fact that was not apparent in the measurement results supplied by the vendor using transmission electron microscopy. This finding illustrates the utility of spICP-MS for routine characterization of commercial AuNP suspensions regardless of size or coating.

3.
Environ Sci Technol ; 52(10): 5968-5978, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29672024

RESUMO

The increased use and incorporation of engineered nanoparticles (ENPs) in consumer products requires a robust assessment of their potential environmental implications. However, a lack of standardized methods for nanotoxicity testing has yielded results that are sometimes contradictory. Standard ecotoxicity assays may work appropriately for some ENPs with minimal modification but produce artifactual results for others. Therefore, understanding the robustness of assays for a range of ENPs is critical. In this study, we evaluated the performance of a standard Caenorhabditis elegans ( C. elegans) toxicity assay containing an Escherichia coli ( E. coli) food supply with silicon, polystyrene, and gold ENPs with different charged coatings and sizes. Of all the ENPs tested, only those with a positively charged coating caused growth inhibition. However, the positively charged ENPs were observed to heteroagglomerate with E. coli cells, suggesting that the ENPs impacted the ability of nematodes to feed, leading to a false positive toxic effect on C. elegans growth and reproduction. When the ENPs were tested in two alternate C. elegans assays that did not contain E. coli, we found greatly reduced toxicity of ENPs. This study illustrates a key unexpected artifact that may occur during nanotoxicity assays.


Assuntos
Caenorhabditis elegans , Nanopartículas , Animais , Artefatos , Escherichia coli , Reprodução
4.
Anal Bioanal Chem ; 409(25): 6027-6039, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28815280

RESUMO

Single particle ICP-MS has evolved rapidly as a quantitative method for determining nanoparticle size and number concentration at environmentally relevant exposure levels. Central to the application of spICP-MS is a commonly used, but not rigorously validated, calibration approach based on the measured transport efficiency and the response of ionic standards. In this work, we present a comprehensive and systematic study of the accuracy, precision and robustness of spICP-MS using the rigorously characterized reference material (RM) 8017 (Polyvinylpyrrolidone Coated Nominal 75 nm Silver Nanoparticles), recently issued by the National Institute of Standards and Technology (NIST). We report for the first time, statistically significant differences in frequency-based and size-based measures of transport efficiency with NIST RM 8013 Gold Nanoparticles and demonstrate that the size-based measure of transport efficiency is more robust and yields accurate results for the silver nanoparticle RM relative to TEM-based reference values. This finding is significant, because the frequency-based method is more widely applied. Furthermore, we demonstrate that the use of acidified ionic standards improves measurement of ICP-MS Ag response, but does not degrade the accuracy of the results for AgNP suspensions in water or various other diluents. Approaches for controlling AgNP dissolution were investigated and are shown to effectively improve particle stability in dilute suspensions required for spICP-MS analysis, while minimally affecting the measured intensity and allowing for more robust analysis. This study is an important and necessary advancement toward full validation and adoption of spICP-MS by the broader research community. Graphical abstract Measurement challenges in spICP-MS analysis.

5.
J Chromatogr A ; 1511: 59-67, 2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28697934

RESUMO

The physicochemical characterization of nanoparticles (NPs) is of paramount importance for tailoring and optimizing the properties of these materials as well as for evaluating the environmental fate and impact of the NPs. Characterizing the size and chemical identity of disperse NP sample populations can be accomplished by coupling size-based separation methods to physical and chemical detection methods. Informed decisions regarding the NPs can only be made, however, if the separations themselves are quantitative, i.e., if all or most of the analyte elutes from the column within the course of the experiment. We undertake here the size-exclusion chromatographic characterization of Au NPs spanning a six-fold range in mean size. The main problem which has plagued the size-exclusion chromatography (SEC) analysis of Au NPs, namely lack of quantitation accountability due to generally poor NP recovery from the columns, is overcome by carefully matching eluent formulation with the appropriate stationary phase chemistry, and by the use of on-line inductively coupled plasma mass spectrometry (ICP-MS) detection. Here, for the first time, we demonstrate the quantitative analysis of Au NPs by SEC/ICP-MS, including the analysis of a ternary NP blend. The SEC separations are contrasted to HDC/ICP-MS (HDC: hydrodynamic chromatography) separations employing the same stationary phase chemistry. Additionally, analysis of Au NPs by HDC with on-line quasi-elastic light scattering (QELS) allowed for continuous determination of NP size across the chromatographic profiles, circumventing issues related to the shedding of fines from the SEC columns. The use of chemically homogeneous reference materials with well-defined size range allowed for better assessment of the accuracy and precision of the analyses, and for a more direct interpretation of results, than would be possible employing less rigorously characterized analytes.


Assuntos
Cromatografia em Gel , Ouro/química , Nanopartículas Metálicas/análise , Difusão Dinâmica da Luz , Hidrodinâmica , Espectrometria de Massas , Nanopartículas Metálicas/química , Tamanho da Partícula
6.
Front Chem ; 5: 6, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28271059

RESUMO

Silver nanoparticles (AgNPs) show different physical and chemical properties compared to their macroscale analogs. This is primarily due to their small size and, consequently, the exceptional surface area of these materials. Presently, advances in the synthesis, stabilization, and production of AgNPs have fostered a new generation of commercial products and intensified scientific investigation within the nanotechnology field. The use of AgNPs in commercial products is increasing and impacts on the environment and human health are largely unknown. This article discusses advances in AgNP production and presents an overview of the commercial, societal, and environmental impacts of this emerging nanoparticle (NP), and nanomaterials in general. Finally, we examine the challenges associated with AgNP characterization, discuss the importance of the development of NP reference materials (RMs) and explore their role as a metrological mechanism to improve the quality and comparability of NP measurements.

7.
Anal Bioanal Chem ; 408(27): 7629-7640, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27503544

RESUMO

Single particle inductively coupled plasma mass spectrometry (spICP-MS) is shown to be a practical technique to study the efficacy of rate-zonal sucrose density gradient centrifugation (SDGC) separations of mixtures of gold nanoparticles (AuNPs) in liquid suspension. spICP-MS enabled measurements of AuNP size distributions and particle number concentrations along the gradient, allowing unambiguous evaluations of the effectiveness of the separation. Importantly, these studies were conducted using AuNP concentrations that are directly relevant to environmental studies (sub ng mL-1). At such low concentrations, other techniques [e.g., dynamic light scattering (DLS), transmission and scanning electron microscopies (TEM and SEM), UV-vis spectroscopy, atomic force microscopy (AFM)] do not have adequate sensitivity, highlighting the inherent value of spICP-MS for this and similar applications. In terms of the SDGC separations, a mixture containing three populations of AuNPs, having mean diameters of 30, 80, and 150 nm, was fully separated, while separations of two other mixtures (30, 60, 100 nm; and 20, 50, 100 nm) were less successful. Finally, it is shown that the separation capacity of SDGC can be overwhelmed when particle number concentrations are excessive, an especially relevant finding in view of common methodologies taken in nanotechnology research. Graphical Abstract Characterization of the separation of a gold nanoparticle mixture by sucrose density gradient centrifugation by conventional and single particle ICP-MS analysis.

8.
Anal Bioanal Chem ; 408(19): 5051-2, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27209588
9.
Environ Sci Technol ; 50(9): 4587-605, 2016 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-27050152

RESUMO

Carbon nanotubes (CNTs) have numerous exciting potential applications and some that have reached commercialization. As such, quantitative measurements of CNTs in key environmental matrices (water, soil, sediment, and biological tissues) are needed to address concerns about their potential environmental and human health risks and to inform application development. However, standard methods for CNT quantification are not yet available. We systematically and critically review each component of the current methods for CNT quantification including CNT extraction approaches, potential biases, limits of detection, and potential for standardization. This review reveals that many of the techniques with the lowest detection limits require uncommon equipment or expertise, and thus, they are not frequently accessible. Additionally, changes to the CNTs (e.g., agglomeration) after environmental release and matrix effects can cause biases for many of the techniques, and biasing factors vary among the techniques. Five case studies are provided to illustrate how to use this information to inform responses to real-world scenarios such as monitoring potential CNT discharge into a river or ecotoxicity testing by a testing laboratory. Overall, substantial progress has been made in improving CNT quantification during the past ten years, but additional work is needed for standardization, development of extraction techniques from complex matrices, and multimethod comparisons of standard samples to reveal the comparability of techniques.


Assuntos
Meio Ambiente , Nanotubos de Carbono/toxicidade , Humanos , Limite de Detecção
10.
Anal Bioanal Chem ; 408(19): 5099-108, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26894759

RESUMO

The effect of ICP-MS instrument sensitivity drift on the accuracy of nanoparticle (NP) size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 and 60 nm gold nanoparticles. Graphical Abstract Correction of nanoparticle size measurement by spICP-MS using an internal standard.

11.
Anal Chem ; 87(17): 8809-17, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26265147

RESUMO

Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS can be considered a mature methodology, additional work is needed to standardize this technique including an assessment of the reliability and variability of size distribution measurements and the transferability of the technique among laboratories. This paper presents the first post hoc interlaboratory comparison study of the spICP-MS technique. Measurement results provided by six expert laboratories for two National Institute of Standards and Technology (NIST) gold nanoparticle reference materials (RM 8012 and RM 8013) were employed. The general agreement in particle size between spICP-MS measurements and measurements by six reference techniques demonstrates the reliability of spICP-MS and validates its sizing capability. However, the precision of the spICP-MS measurement was better for the larger 60 nm gold nanoparticles and evaluation of spICP-MS precision indicates substantial variability among laboratories, with lower variability between operators within laboratories. Global particle number concentration and Au mass concentration recovery were quantitative for RM 8013 but significantly lower and with a greater variability for RM 8012. Statistical analysis did not suggest an optimal dwell time, because this parameter did not significantly affect either the measured mean particle size or the ability to count nanoparticles. Finally, the spICP-MS data were often best fit with several single non-Gaussian distributions or mixtures of Gaussian distributions, rather than the more frequently used normal or log-normal distributions.

12.
Anal Chem ; 86(7): 3405-14, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24575780

RESUMO

The increasing application of engineered nanomaterials (ENMs) in consumer and medical products has motivated the development of single-particle inductively coupled plasma mass spectrometry (spICP-MS) for characterizing nanoparticles under realistic environmental exposure conditions. Recent studies have established a set of metrological criteria and evaluated the feasibility of spICP-MS for sizing or quantifying various highly commercialized ENMs. However, less is known about the performance of spICP-MS for detecting nanoparticles with sizes greater than 80 nm. This paper presents a systematic study on spICP-MS for accurate size measurement of gold nanoparticles from 10 to 200 nm. We show that dwell time contributes significantly to the quality of data, with the optimal dwell time that limits split particle events, particle coincidences and false positives being 10 ms. A simple approach to correct for split particle events is demonstrated. We show that transient features of single particle events can be temporally resolved on a conventional quadrupole ICP-MS system using a sufficiently short dwell time (0.1 ms). We propose an intensity-size diagram for estimating the linear dynamic size range and guiding the selection of ICP-MS operating conditions. The linear dynamic size range of the ICP-MS system under standard (highest) sensitivity conditions is 10 to 70 nm but can be further extended to 200 nm by operating in less sensitive modes. Finally, the ability of spICP-MS to characterize heterogeneous forms of metal containing nanoparticles is evaluated in mixtures containing both dissolved and poly disperse nanoparticulate Au.


Assuntos
Ouro/química , Nanopartículas Metálicas , Espectrometria de Massas , Tamanho da Partícula
13.
Anal Bioanal Chem ; 405(7): 2279-88, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23338753

RESUMO

We report the development of a hyphenated instrument with the capacity to quantitatively characterize aqueous suspended gold nanoparticles (AuNPs) based on a combination of gas-phase size separation, particle counting, and elemental analysis. A customized electrospray-differential mobility analyzer (ES-DMA) was used to achieve real-time upstream size discrimination. A condensation particle counter and inductively coupled plasma mass spectrometer (ICP-MS) were employed as downstream detectors, providing information on number density and elemental composition, respectively, of aerosolized AuNPs versus the upstream size selected by ES-DMA. A gas-exchange device was designed and optimized to improve the conversion of air flow (from the electrospray) to argon flow required to sustain the ICP-MS plasma, the key compatibility issue for instrumental hyphenation. Our work provides the proof of concept and a working prototype for utilizing this construct to successfully measure (1) number- and mass-based distributions; (2) elemental compositions of nanoparticles classified by size, where the size classification and elemental analysis are performed within a single experiment; (3) particle concentrations in both solution (before size discrimination) and aerosol (after size discrimination) phases; and (4) the number of atoms per nanoparticle or the nanoparticle density.

14.
Anal Bioanal Chem ; 403(1): 145-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22349346

RESUMO

In this study, a prototypical thiolated organic ligand, 3-mercaptopropionic acid (MPA), was conjugated on gold nanoparticles (AuNPs), and packing density was measured on an ensemble-averaged basis using inductively coupled plasma optical emission spectrometry. The effects of sample preparation, including centrifugation and digestion, as well as AuNP size and concentration, on recovery were investigated. For AuNPs with diameters of 5, 10, 30, 60, and 100 nm, calculated packing density is independent of size, averaging 7.8 nm(-2) and ranging from 6.7 to 9.0 nm(-2), and is comparable to reported values for MPA and similar short-chain ligands on AuNPs. These preliminary data provide fundamental information on the advantages and limitations of ICP-based analyses of conjugated AuNP systems. Moreover, they provide necessary information for the development of more broadly applicable methods for quantifying nanoparticle-ligand conjugates of critical importance to nanomedicine applications.


Assuntos
Ouro/química , Nanopartículas Metálicas , Ligantes
15.
Anal Chem ; 83(10): 3801-7, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21480672

RESUMO

A high-performance (HP) technique that was originally developed for inductively coupled plasma optical emission spectrometry (ICP-OES) has been successfully translated to ion chromatography (IC) to enable analyses with extremely low uncertainty. As an example application of the HP-IC methodology, analyses of several National Institute of Standards and Technology (NIST) Standard Reference Materials (SRMs) in the SRM 3180 series of anion standard solutions are reported. The relative expanded uncertainty values expressed at 95% confidence for these analyses range from 0.087% to 0.27% and average 0.18%. Strong correlation between analyte and internal standard anion peak heights or peak areas, as well as the use of a unique drift-correction approach, is shown to be important for attaining such low uncertainty.

16.
Anal Chem ; 82(18): 7675-83, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20795649

RESUMO

Exact matching is investigated as a means of improving high-performance inductively coupled plasma optical emission spectrometry (HP-ICP-OES), a technique developed at the National Institute of Standards and Technology (NIST) to enable elemental determinations with relative expanded uncertainty of approximately 0.2% expressed at 95% confidence. "Exact matching" refers to the very careful matching of analyte mass fractions, internal standard mass fractions, and matrix compositions among the calibration and unknown sample solutions prepared for an analysis. Computer spreadsheet modeling results and laboratory data involving 16 pairs of analyte and internal standard wavelengths show that exact matching of analyte and internal standard mass fractions mitigates imprecision and bias that can be caused by even subtle nonlinearity in the ICP-OES instrument response. Laboratory experiments also demonstrate matrix effects caused by small variations in acid composition and by mass fractions of Na less than 4 mg kg(-1), emphasizing the need for exact matching of matrix compositions. HP-ICP-OES analyses performed at NIST with and without exact matching illustrate that exact matching enables relative expanded uncertainties to be halved to approximately 0.1%.

18.
Microsc Microanal ; 16(1): 1-12, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20030913

RESUMO

Bulk silicon-germanium (SiGe) alloys and two SiGe thick films (4 and 5 microm) on Si wafers were tested with the electron probe microanalyzer (EPMA) using wavelength dispersive spectrometers (WDS) for heterogeneity and composition for use as reference materials needed by the microelectronics industry. One alloy with a nominal composition of Si0.86Ge0.14 and the two thick films with nominal compositions of Si0.90Ge0.10 and Si0.75Ge0.25 on Si, evaluated for micro- and macroheterogeneity, will make good microanalysis reference materials with an overall expanded heterogeneity uncertainty of 1.1% relative or less for Ge. The bulk Ge composition in the Si0.86Ge0.14 alloy was determined to be 30.228% mass fraction Ge with an expanded uncertainty of the mean of 0.195% mass fraction. The thick films were quantified with WDS-EPMA using both the Si0.86Ge0.14 alloy and element wafers as reference materials. The Ge concentration was determined to be 22.80% mass fraction with an expanded uncertainty of the mean of 0.12% mass fraction for the Si0.90Ge0.10 wafer and 43.66% mass fraction for the Si0.75Ge0.25 wafer with an expanded uncertainty of the mean of 0.25% mass fraction. The two thick SiGe films will be issued as National Institute of Standards and Technology Reference Materials (RM 8905).

19.
Anal Chem ; 81(9): 3414-20, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19344148

RESUMO

An automated sample introduction system, utilizing a demountable direct injection high-efficiency nebulizer (d-DIHEN), is successfully incorporated for the first time with an inductively coupled plasma optical emission spectrometer (ICP-OES) for the measurement of the phosphorus content in acid-digested nucleotides and deoxyribonucleic acid (DNA). With this experimental setup, the solution uptake rate and volume are reduced from 170 to 30 microL min(-1) and from 10 to 2.4 mL, respectively, thereby reducing the required DNA sample mass for solutions containing 3 microg g(-1) P from 300 to 72 microg of DNA, in comparison to previous analyses in our laboratory using a glass concentric nebulizer with cyclonic spray chamber arrangement. The use of direct injection also improves P (I) 213.617 nm sensitivity by a factor of 4 on average. A high-performance (HP) methodology in combination with the previous sample introduction system and ICP-OES provides simultaneous, time-correlated internal standardization and drift correction resulting in relative expanded uncertainties (% U) for the P mass fractions in the range of 0.1-0.4 (95% confidence level) for most of the thymidine 5'-monophosphate (TMP), calf thymus DNA (CTDNA), and plasmid DNA (PLDNA) analyses. The d-DIHEN with HP-ICP-OES methodology allows for the quantification of DNA mass at P mass fractions as low as 0.5 microg g(-1), further reducing the required DNA mass to 12 microg, with small uncertainty (< or = 0.4%). This successful approach will aid in the development and certification of nucleic acid certified reference materials (CRMs), particularly for these samples that are typically limited in volume.


Assuntos
DNA/análise , Métodos Analíticos de Preparação de Amostras , Animais , DNA/química , Vidro , Nebulizadores e Vaporizadores , Nucleotídeos/análise , Nucleotídeos/química , Fósforo/química , Análise Espectral
20.
Anal Chem ; 81(6): 2208-17, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19209906

RESUMO

High-performance inductively coupled plasma optical emission spectrometry (HP-ICP-OES) was used to certify the Be mass fraction in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1877 Beryllium Oxide Powder. The certified value and expanded uncertainty expressed at a 95% confidence level is (0.3576 +/- 0.0024) g/g. To obtain best results, the Be mass fractions, Mn (internal standard) mass fractions, and matrix compositions of the calibration solutions were carefully matched to those of the sample solutions for each individual HP-ICP-OES analysis. This "exact matching" approach was used because experience at NIST has shown that it often affords improved accuracy and precision in HP-ICP-OES analysis. NIST has never published these observations. Due to the toxicity of BeO and the difficulty of containing the very fine powder material, sets of solutions for HP-ICP-OES analysis were prepared by laboratories collaborating with NIST who have the experience and equipment needed to work with the material safely. Each laboratory utilized a unique digestion protocol(s). After preparing the sets of solutions, the collaborating laboratories shipped them to NIST for HP-ICP-OES analysis. NIST provided the collaborating laboratories with solution preparation kits and spreadsheets to help establish traceability of the HP-ICP-OES results to the International System of Units (SI) and to allow exact matching to be accomplished. The agreement observed among the four individual Be mass fraction values determined from the sets of solutions prepared by the collaborating laboratories was 0.074% relative (1s of mean). The excellent agreement provides a measure of confidence in the robustness of each of the digestion procedures, as well as in the certified Be mass fraction value. The analytical benefits of using exact matching for this particular certification were investigated. Results show that exactly matching the matrix compositions of the standards to the samples for each HP-ICP-OES analysis was critical to obtaining the excellent agreement observed among the individual Be mass fraction values and also helped to minimize bias and uncertainty in the certified value. Unlike previous NIST studies, exactly matching the Be and Mn mass fractions of the standards to the samples for this particular certification appears to have had little effect on the data.


Assuntos
Berílio/química , Certificação , Espectrofotometria Atômica/métodos , Berílio/normas , Peso Molecular , Padrões de Referência , Espectrofotometria Atômica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...